• 제목/요약/키워드: High-voltage rectification

검색결과 48건 처리시간 0.03초

X선 고전압 장치의 정류형태에 따른 리플 비교 (Comparison of Ripple of High Voltage X-ray Generator by Rectification type)

  • 김영표;김태곤;천민우;이호식;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.128-128
    • /
    • 2010
  • The high-voltage X-ray generator recently used is very popular, because that can be miniaturized, increased in generating efficiency, elaborated in output control. All these features are available with high-frequency made by using an inverter, the fast switching semiconductor device. In this paper to identify the differences among types of rectification, we compared output ripple with full-wave rectification and dual-voltage rectification methods.

  • PDF

전파 정류 교류 구동 방식에 의한 OLED의 전계발광 특성 (Electroluminescence Characteristics of OLED by Full-Wave Rectification Alternating Current Driving Method)

  • 서정현;주성후
    • 한국재료학회지
    • /
    • 제32권7호
    • /
    • pp.320-325
    • /
    • 2022
  • Single OLED and tandem OLED was manufactured to analyze the electroluminescence characteristics of DC driving, AC driving, and full-wave rectification driving. The threshold voltage of OLED was the highest in DC driving, and the lowest in full-wave rectification driving due to an improvement of current injection characteristics. The luminance at a driving voltage lower than 10.5 V (8,534 cd/m2) of single OLED and 20 V (7,377 cd/m2) of a tandem OLED showed that the full-wave rectification drive is higher than that of DC drive. The luminous efficiency of OLED is higher in full-wave rectification driving than in DC driving at low voltage, but decrease at high voltage. The full-wave rectification power source may obtain higher current density, higher luminance, and higher current efficiency than the AC power source. In addition, it was confirmed that the characteristics of AC driving and full-wave rectification driving can be predicted from DC driving characteristics by comparing the measured values and calculated values of AC driving and full-wave rectification driving emission characteristics. From the above results, it can be seen that OLED lighting with improved electroluminescence characteristics compared to DC driving is possible using full-wave rectification driving and tandem OLED.

X선 고전압장치의 전파 및 배전압 정류방식에 따른 X선 출력 및 선질 비교 (Comparison of Output and Radiation Quality of X-rays according to the Full-Wave Rectification Method and Dual-Voltage Rectification Method of an X-ray Generator)

  • 김태곤;천민우;박용필
    • 한국전기전자재료학회논문지
    • /
    • 제23권7호
    • /
    • pp.534-538
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. Being capable of locally inspecting the inside of the body, X-ray systems are routinely used for basic diagnosis. X-ray systems to be used for medical purposes were originally made with a gas filled tube inside an induction coil in the initial stages of development but with this approach it becomes difficult to take a satisfactory picture through thick body sections, non invasively. However continued development made it possible to take non-invasive pictures of breasts, blood vessels and other body parts through thick body sections. Recently, high-voltage X-ray generators of more compact size, increased generation efficiency, and sophisticated output control have become possible. All of these features are made possible by the use of a high-frequency output from an inverter and a fast switching semiconductor device. In this paper, we describe a new X-ray generator operating with a resonant inverter in order to reduce switching loss and high frequency noise. In addition, in order to identify the differences amongst types of rectification, we have compared output and the quality of X-ray pictures obtained with full-wave rectification and dual-voltage rectification methods.

High Ratio Bidirectional DC-DC Converter with a Synchronous Rectification H-Bridge for Hybrid Energy Sources Electric Vehicles

  • Zhang, Yun;Gao, Yongping;Li, Jing;Sumner, Mark;Wang, Ping;Zhou, Lei
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2035-2044
    • /
    • 2016
  • In order to match the voltages between high voltage battery stacks and low voltage super-capacitors with a high conversion efficiency in hybrid energy sources electric vehicles (HESEVs), a high ratio bidirectional DC-DC converter with a synchronous rectification H-Bridge is proposed in this paper. The principles of high ratio step-down and step-up operations are analyzed. In terms of the bidirectional characteristic of the H-Bridge, the bidirectional synchronous rectification (SR) operation is presented without any extra hardware. Then the SR power switches can achieve zero voltage switching (ZVS) turn-on and turn-off during dead time, and the power conversion efficiency is improved compared to that of the diode rectification (DR) operation, as well as the utilization of power switches. Experimental results show that the proposed converter can operate bidirectionally in the wide ratio range of 3~10, when the low voltage continuously varies between 15V and 50V. The maximum efficiencies are 94.1% in the Buck mode, and 93.6% in the Boost mode. In addition, the corresponding largest efficiency variations between SR and DR operations are 4.8% and 3.4%. This converter is suitable for use as a power interface between the battery stacks and super-capacitors in HESEVs.

자기구동 동기정류를 위한 고효율 DC/DC컨버터의 특성비교 (Characteristics of High Efficiency DC/DC Converter for Self-Dr Synchronous Retifier)

  • 윤석호;문건우;윤종수;김용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.1973-1976
    • /
    • 1998
  • Recently, new trend in telecommunication device is to apply low voltage, about 3.3V-1.5V. However, it is undesirable in view of high efficiency and power desity which is the most important requirement in the distributed power system. Rectification loss in the output stage, in on-board converter for distributed power system are constrained to obtain high efficience at low output voltage power suppies. This paper explains the basic operational principles of three kinds of ZVS DC/DC converters with self-driven synchronous rectifier. The three topologies are analyzed by simulation and exprimentation, and the characteristics comparisons of high efficience converter are carried out in view of the minimized rectification losses in the out stage.

  • PDF

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • 나길주;백수웅;양현훈;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

전파정류방식의 고전압발생장치를 이용한 X선 기기의 특성 평가 (Characteristic Analysis of X-ray Device using the High Voltage Generator on Full-wave Rectification Method)

  • 김영표;김태곤;이호식;박용필;천민우
    • 한국전기전자재료학회논문지
    • /
    • 제22권6호
    • /
    • pp.516-521
    • /
    • 2009
  • X-ray system which is usefully used in diagnosis of the patient, being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This research has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

A High Frequency-Link Bidirectional DC-DC Converter for Super Capacitor-Based Automotive Auxiliary Electric Power Systems

  • Mishima, Tomokazu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.27-33
    • /
    • 2010
  • This paper presents a bidirectional DC-DC converter suitable for low-voltage super capacitor-based electric energy storage systems. The DC-DC converter presented here consists of a full-bridge circuit and a current-fed push-pull circuit with a high frequency (HF) transformer-link. In order to reduce the device-conduction losses due to the large current of the super capacitor as well as unnecessary ringing, synchronous rectification is employed in the super capacitor-charging mode. A wide range of voltage regulation between the battery and the super capacitor can be realized by employing a Phase-Shifting (PS) Pulse Width Modulation (PWM) scheme in the full-bridge circuit for the super capacitor charging mode as well as the overlapping PWM scheme of the gate signals to the active power devices in the push-pull circuit for the super capacitor discharging mode. Essential performance of the bidirectional DC-DC converter is demonstrated with simulation and experiment results, and the practical effectiveness of the DC-DC converter is discussed.

X선 진단장치의 고압정류방식이 대조도 향상에 미치는 영향 (Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus)

  • 이후민;윤준;김현주
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.187-193
    • /
    • 2014
  • 본 연구는 X선 진단장치의 고압정류방식이 그리드 성능을 측정하는 선택도(selectivity)와 대조도 향상능력(contrast improvement ability : K factor)에 미치는 영향을 분석하고자 산란선 함유율을 측정하였다. 정류방식이 서로 다른 X선발생장치를 대상으로 각 장치의 관전압과, 관전류량을 측정하여 출력선량의 정확도를 측정 및 교정한 후 각 장치별 노출조건을 동일하게 설정하고 형광량계를 이용하여 아크릴을 투과한 X선의 산란선 함유율을 측정하였다. Grid 미사용 시 피사체를 투과한 X선의 산란선 함유율 측정 결과는 단상정류방식장치에서 가장 낮은 함유율(34.158%)이 측정되었고, 인버터 정류방식(37.043%)과 삼상24피크 정류방식(37.447%)은 산란선 함유율이 증가하였다. 각 장치들의 산란선 함유율 차이는 최저 0.404%에서 최고 3.289%의 차이를 보였다. 8:1 Gird 사용 시 피사체를 투과한 X선의 산란선 함유율을 측정한 결과는 단상정류방식장치에서 가장 낮은 함유율(18.258%)로 측정되었고, 인버터정류방식(25.502%)과 삼상24피크정류방식에서 산란선 함유율(24.217%)이 증가하였다. 그리드 선택도에 따라 단상정류방식과 정전압(인버터와 삼상24피크)정류방식에서 산란선함유율의 차이는 최저 1.285%에서 최고 7.244%의 차이를 보였다. 통계분석 결과 단상정류방식 및 정전압정류방식에서 대조도 향상계수(K factor)에서도 유의한 차이를 보였다. 결론적으로 그리드 선택도와 대조도 향상계수는 정전압정류방식보다는 단상전파방식에서 모두 증가하여 그리드의 사용으로 선택도 향상과 대조도의 개선효과가 증가함을 알 수 있었다.

An Improved Zero Voltage Switching Forward DC/DC Converter For Reducing Switching Losses

  • Kim, Eun-Soo;Joe, Kee-Yeon;Park, Hae-Young;Kim, Yoon-Ho;Kim, Choon-Same
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.1051-1055
    • /
    • 1998
  • To achieve high efficiency in high power and high frequency applications, reduction of switching losses and noise is very important. In this paper, an improved zero voltage switching forward dc/dc converter is proposed. The proposed converter is constructed by using energy recovery snubbers in parallel with the main switches and output diodes of the conventional forward dc/dc converter. Due to the use of the energy recovery snubbers in the primary and secondary side, the proposed converter achieves zero-voltage-switching turn-off without switching losses for switching devices and output rectification diodes. The complete operating principles and experimental results will be presented.