• 제목/요약/키워드: High-temperature test

검색결과 3,720건 처리시간 0.037초

최적화 설계를 통한 혼합가스 성능시험용 고온 고압 용기의 제작 (Manufacture of High-temperature High-pressure Vessel for Mixed Gas Performance Test via Optimized Design)

  • 구현곤;류형민;안재웅;배영관;김진희
    • 한국기계가공학회지
    • /
    • 제18권11호
    • /
    • pp.83-88
    • /
    • 2019
  • In this study, the high-temperature high-pressure vessel was successfully manufactured, which can be used to store pressurized air and to increase the temperature for the mix performance test of high-temperature high-pressure air with coolant (e.g., water). In this research, static structure analysis and transient thermal analysis were performed using the commercial software Midas NFX 2015 R1. Based on the results, the optimized pressure vessel design was carried out. As a result of the optimized design, the minimum stress and minimum weight were found at 120 mm of the vessel thickness, and the optimized pressure vessel was verified. Finally, through manufacture and performance test (e.g., the non-destructive inspection and hydraulic pressure test), the reliability and safety were validated for the designed pressure vessel.

고온 고압 공기가열기 성능시험 (Performance Test of Vitiated Air Heater with High Temperature and High Pressure)

  • 이정민;나재정;홍윤기;김정우
    • 한국추진공학회지
    • /
    • 제22권4호
    • /
    • pp.68-75
    • /
    • 2018
  • 본 연구는 설계된 고온 고압 연소식 공기가열기의 성능을 확인하기 위한 성능시험과 그 결과분석에 대한 것이다. 총 4가지의 시험조건에 대한 시험과 3가지 조건에 대한 레이크 측정 시험이 수행되었다. 성능시험결과 목표 온도와 공급 유량조건을 모두 만족하였으며, 최대 공급온도 2000 K, 최대 연소압력 40 bar의 조건을 만족하였다. 공급된 메탄의 유량은 이론값보다 최대 36% 증가하였으며, 측정된 온도는 이론적으로 계산된 온도보다 최대 19.6%의 차이를 보였다.

Corrosion Behavior of Nickel-Plated Alloy 600 in High Temperature Water

  • Kim, Ji Hyun;Hwang, Il Soon
    • Corrosion Science and Technology
    • /
    • 제7권1호
    • /
    • pp.61-67
    • /
    • 2008
  • In this paper, electrochemical and microstructural characteristics of nickel-plated Alloy 600 were investigated in order to identify the performance of electroless Ni-plating on Alloy 600 in high-temperature aqueous condition with the comparison of electrolytic nickel-plating. For high temperature corrosion test of nickel-plated Alloy 600, specimens were exposed for 770 hours to typical PWR primary water condition. During the test, open circuit potentials (OCP's) of all specimens were measured using a reference electrode. Also, resistance to flow accelerated corrosion (FAC) test was examined in order to check the durability of plated layers in high-velocity flow environment at high temperature. After exposures to high flow rate aqueous condition, the integrity of surfaces was confirmed by using both scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS). For the field application, a remote process for electroless nickel-plating was demonstrated using a plate specimen with narrow gap on a laboratory scale. Finally, a practical seal design was suggested for more convenient application.

Study on bond behavior of steel reinforced high strength concrete after high temperatures

  • Chen, Zongping;Zhou, Ji;Wang, Xinyue
    • Advances in concrete construction
    • /
    • 제10권2호
    • /
    • pp.113-125
    • /
    • 2020
  • This paper presents experimental results on bond-slip behavior of steel reinforced high-strength concrete (SRHC) after exposure to elevated temperatures. Three parameters were considered in this test: (a) high temperatures (i.e., 20℃, 200℃, 400℃, 600℃, 800℃); (b) concrete strength (i.e., C60, C70, C80); (c) anchorage length (i.e., 250 mm, 400 mm). A total of 17 SRHC specimens subjected to high temperatures were designed for push out test. The load-slip curves at the loading end and free end were obtained, the influence of various variation parameters on the ultimate bond strength and residual bond strength was analyzed, in addition, the influence of elevated temperatures on the invalidation mechanism was researched in details. Test results show that the shapes of load-slip curves at loading ends and free ends are similar. The ultimate bond strength and residual bond strength of SRHC decrease first and then recover partly with the temperature increasing. The bond strength is proportional to the concrete strength, and the bond strength is proportional to the anchoring length when the temperature is low, while the opposite situation occurs when the temperature is high. What's more, the bond damage of specimens with lower temperature develops earlier and faster than the specimens with higher temperature. From these experimental findings, the bond-slip constitutive formula of SRHC subjected to elevated temperatures is proposed, which fills well with test data.

인코벨 690 증기발생기 세관의 고온 마모 거동 (High Temperature Wear Behavior of Inconel 690 Steam Generator tube)

  • 홍진기;김인섭;김형남;장기상
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.59-62
    • /
    • 2001
  • Flow induced vibration in steam generators has caused dynamic interactions between tubes and contacting materials resulting in fretting wear . Series of experiments have been performed to examine the wear properties of Inconel 690 steam generator tubes in various environmental conditions. For the present study, the test rig was designed to examine the fretting wear and rolling wear properties in high temperature(room temperature - 290。C) water. The test was performed at constant applied load and sliding distance to investigate the effect of test temperature on wear properties of the steam generator tube materials. To investigate the wear mechanism of material, the worn was observed using scanning electron microscopy. The weight loss increase at higher test temperature was caused by the decrease of water viscosity and the mechanical property change of tube material. The mechanical property changes of steam generator tube material, such as decrease of hardness or yield stress in the high temperature tests. From the SEM observation of worn surfaces, the severe wear scars were observed in specimens tested at the higher temperature.

  • PDF

TiC-Mo 공정복합재료의 고온 변형특성 (Deformation Properties of TiC-Mo Eutectic Composite at High Temperature)

  • 신순기
    • 한국재료학회지
    • /
    • 제23권10호
    • /
    • pp.568-573
    • /
    • 2013
  • The deformation properties of a TiC-Mo eutectic composite were investigated in a compression test at temperatures ranging from room temperature to 2053 K and at strain rates ranging from $3.9{\times}10^{-5}s^{-1}$ to $4.9{\times}10^{-3}s^{-1}$. It was found that this material shows excellent high-temperature strength as well as appreciable room-temperature toughness, suggesting that the material is a good candidate for high-temperature application as a structure material. At a low-temperature, high strength is observed. The deformation behavior is different among the three temperature ranges tested here, i.e., low, intermediate and high. At an intermediate temperature, no yield drop occurs, and from the beginning the work hardening level is high. At a high temperature, a yield drop occurs again, after which deformation proceeds with nearly constant stress. The temperature- and yield-stress-dependence of the strain is the strongest in this case among the three temperature ranges. The observed high-temperature deformation behavior suggests that the excellent high-temperature strength is due to the constraining of the deformation in the Mo phase by the thin TiC components, which is considerably stronger than bulk TiC. It is also concluded that the appreciable room-temperature toughness is ascribed to the frequent branching of crack paths as well as to the plastic deformation of the Mo phase.

XKT-1T 항공기 환경 요구사항 적합화 연구 (A study on the Tailoring of Environmental Requirements for XKT-1T Aircraft)

  • 김진석
    • 시스템엔지니어링학술지
    • /
    • 제17권1호
    • /
    • pp.97-106
    • /
    • 2021
  • The purpose of the study on the tailoring of environmental requirements for KT-1 Export Version(XKT-1T) aircraft is not only based on meeting the compliance of the environmental reliability, customer satisfaction, but also for the expansion of its export. This paper proposes the environmental requirements tailoring processes and High/Low temperature conditions, test procedures, and the results of test profiles for the aircraft. Amongst many existing environmental requirements, the temperature requirements are considered as the most basic and the most important environmental requirements. The High/Low temperature tests are considered and tailored to the high and low temperature methods of MIL-STD-810.

Effects of Test Temperature on the Reciprocating Wear of Steam Generator Tubes

  • Hong, J.K.;Kim, I.S.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.379-380
    • /
    • 2002
  • Steam generators (S/G) of pressurized water reactors are large heat exchangers that use the heat from the primary reactor coolant to make steam in the secondary side for driving turbine generators. Reciprocating sliding wear experiments have been performed to examine the wear properties of Incoloy 800 and Inconel 690 steam generator tubes in high temperature water. In present study, the test rig was designed to examine the reciprocating and rolling wear properties in high temperature (room temperature - $300^{\circ}C$) water. The test was performed at constant applied load and sliding distance to investigate the effect of test temperature on wear properties of steam generator tube materials. To investigate the wear mechanism of material, the worn surfaces were observed using scanning electron microscopy. At $290^{\circ}C$, wear rate of Inconel 690 was higher than that of Incoloy 800. It was assumed to be resulted from the oxide layer property difference due to the a\loy composition difference. Between 25 and $150^{\circ}C$ the wear loss increased with increasing temperature. Beyond $150^{\circ}C$, the wear loss decreased with increasing temperature. The wear loss change with temperature were due to the formation of wear protective oxide layer. From the worn surface observation, texture patterns and wear particle layers were found. As test temperature increased, the proportion of particle layer increased.

  • PDF

플라이 애쉬를 다량 치환한 콘크리트의 중성화 특성에 관한 실험적 연구 (The Experimental Study on Neutralization Properties of High Volume Fly-Ash Concrete)

  • 백민수;김우상;김종원;김제섭;김성식;정상진
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.69-74
    • /
    • 2003
  • This study evaluated durability through measurement of substituted test piece's pH degree and experiments of neutralization. Comparing and evaluating cared test piece's pH degrees which we got before the neutralization and after the neutralization. After evaluating neutralization depth through neutralization, evaluating neutralization properties by Fly Ash replacement ratio. pH degree was decreased by cement replacement ratio of Fly Ash. And in the case of substitution of the same amount of Fly Ash, fine aggregate replacement ratio was increased. When the test piece, which had been cared in high temperature, was promoted to neutralization, Among the test piece which was replaced with Fly Ash 40%, the test piece which has high rate of fine aggregate proved opposition of neutralization Through the test, Ⅰ summarized that the test piece cared in high temperature was mostly effected by compress strength, the test piece cared in low temperature was mostly effected by pH degree.

  • PDF

OLED TV Panel의 전류가속열화시험 설계 (Electric Current Accelerated Degradation Test Design for OLED TV)

  • 유지선;이득중;오창석;장중순
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권1호
    • /
    • pp.22-27
    • /
    • 2017
  • Purpose: The purpose of this study is to estimate the life time of OLED TV panel through electric current ADT(Accelerated Degradation Test). Methods: We performed accelerated degradation test for OLED TV Panel at the room temperature to avoid high temperature impact on the luminance. Results: we got more accurately the life time of the OLED TV when we applied ADT without temperature factor than including both current and temperature. Conclusion: Until now, the ADT of the OLED TV has been conducted with temperature and current at the same time for reducing test time and costs. We estimate incorrect life time when the temperature is adopted as an accelerated factor. Due to the high temperature impact on the luminance of the OLED TV panel. So as to solve this problem, we discard temperature and use electric current only.