• 제목/요약/키워드: High-temperature endurance

검색결과 78건 처리시간 0.067초

고성능 RC 기둥의 재하가열시험에 의한 내화 특성 (Properties of Fire Endurance of High Performance RC Column by Loaded Heating Test)

  • 김경민;김기훈;황인성;이재삼;이성연;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.57-60
    • /
    • 2005
  • This study discusses spalling and fire enduring performance of high performance concrete (HPC) RC column subjected to loading under heating for 3 hours. According to the test, both the plain concrete and the concrete attached with fire enduring PC panel exceed allowable temperature after 60 minutes due to the exposure of steel bar and falling off of concrete resulting from severe spalling failure. It leads to buckling of main bar and at the same time, occurrence of collapse of plain HPC column member is observed after 2 hours and 1 hour 40 minutes's exposure to fire, respectively. On the other hand, HPC applying both PP fiber of 0.1$\%$ by mass of concrete and PP fiber+lateral confinement by metal lath maintains their original cross section, which is satisfied with the 3 hours fire endurance criteria, by discharging internal vapour pressure and enhanced lateral confinement force.

  • PDF

Co3O4 첨가량 변화에 따른 ZnO Varistor의 전기적 특성 (Electrical Properties of ZnO Varistors with Variation of Co3O4)

  • 조현무;이성갑
    • 한국전기전자재료학회논문지
    • /
    • 제17권11호
    • /
    • pp.1186-1191
    • /
    • 2004
  • ZnO varistor ceramics which were fabricated with variation of added of 0.5~1.0 mol% Co$_3$O$_4$, were sintered at 1150 $^{\circ}C$. In the specimen added 0.7 mol% Co$_3$O$_4$, sintered density was 6.03 g/㎤ and electrical properties were superior to any other compositions. The nonlinear coefficient a and clamping voltage ratio were 83 and 1.35, respectively. But, endurance surge current in the specimen added 0.5 mol% Co$_3$O$_4$ was 7000 A/$\textrm{cm}^2$, and deviation of varistor voltage was Δ-3.23 %. As P.C.T and T.C.T environmental test were succeed in all specimens, and deviation of varistor voltage in the specimen added 0.6 mol% Co$_3$O$_4$ was Δ-0.81 %. All specimens showed good leakage current property on the High Temperature Continuous Load Test(HTCLT) for 1000 hr at 85 $^{\circ}C$ and variation rate of the varistor voltage below Δ-2.0 %.

촉매연소 시스템 안정화 : 고온용 열교환기를 이용한 능동제어 (Catalytic Combustion System Stability:Active Control with High Temperature Heat Exchanger)

  • 유상필;송광섭
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2002년도 제25회 KOSCI SYMPOSIUM 논문집
    • /
    • pp.65-69
    • /
    • 2002
  • Catalytic combustion known as one of the traditional oxidation methods of VOC gas is restricted to its applicable fields because of its reaction characteristics. But recently innovative improvement of catalytic endurance makes its applicable range broader from MEMs to industrial power generation. Therefore, control technologies based on the catalytic combustion characteristics are researched and developed dynamically. Especially, the stable control of catalytic combustion is an essential factor in a view of maximizing its efficiency. In this research, the fuel equivalence ratio and the preheating temperature of mixture gas is controlled by catalytic combustion system enhanced in heat transfer with high temperature heat exchanger. As a result, the combustion characteristics of system was investigated, and both passive and active control type were compared and analyzed.

  • PDF

섬유를 활용한 고강도 콘크리트기둥의 폭렬제어방안 (Spalling Reduction Method of High Strength Reinforced Concrete Columns Using Fibers)

  • 유석형
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.7-12
    • /
    • 2009
  • 고강도 콘크리트(HSC)는 화재 시 $100^{\circ}C$ 이상에서 부재내부의 수분 증발로 인하여 발생한 수증기가 수밀한 콘크리트에 갇혀 피복이 탈락되는 폭렬현상이 발생한다. 콘크리트의 폭렬을 제어할 수 있는 방안으로는 폴리프로필렌 섬유(PP섬유)를 혼입하는 방법이 가장 효율적인 것으로 보고되었다. 그러나 일정량 이상 PP섬유의 사용은 폭렬저감에 효과가 없으며 특히, 초고강도 콘크리트의 시공성을 저하시킬 것으로 판단된다. 따라서 본 연구에서는 콘크리트 강도 60MPa에서 최적의 PP섬유량을 도출하고 120MPa 초고강도 콘크리트에서 시공성을 확보하기 위하여 PP섬유를 대신하여 PP분말 및 폴리비닐알콜(PVA)섬유를 사용한 기둥실험체의 내화실험 및 잔존강도 실험을 수행하였다. 실험결과 60MPa 실험체에서 PP섬유 함유량이 0%에서 0.2%까지 증가 할수록 잔존 축강도비는 68%에서 85%까지 증가하였으나, PP섬유 함유량이 0.2% 이상에서는 잔존강도의 증가가 거의 나타나지 않았다. 또한, 120Mpa 실험체에서 내화성능과 시공성을 함께 고려할 경우 PVA섬유가 가장 합리적인 것으로 나타났다.

Incidence of exercise-associated hyponatremia during a high-altitude 161-km ultramarathon

  • Khodaee, Morteza;Saeedi, Anahita;Harris-Spinks, Christine;Hew-Butler, Tamara
    • 운동영양학회지
    • /
    • 제25권3호
    • /
    • pp.16-22
    • /
    • 2021
  • [Purpose] Exercise-associated hyponatremia (EAH) is a well-known condition among endurance athletes at low altitudes. The incidence of EAH during ultramarathons at high altitudes warrants further investigation. This prospective observational study was conducted on the participants of the Leadville Trail 100 run, a 161-km race held at a high altitude (2,800 m-3,840 m). [Methods] Venous blood samples were collected before and immediately after the race. The participants completed an electronic survey after the race. Our main outcome measure was the post-race serum sodium ([Na+]) level. [Results] Of the 672 athletes who started the race, 351 (52%) successfully completed the event within the 30-hour cut-off. Post-race blood samples were collected from 84 runners (66 finishers). Both pre- and post-race blood samples were collected from 37 participants. Twenty percent of the post-race participants had EAH. Only one post-race participant had a [Na+] level of <130 mmol/L. All participants with EAH were asymptomatic. One participant had an abnormal pre-race [Na+] level (134 mmol/L). Female participants had a significantly higher rate of EAH than male participants (40% vs. 16%; p=0.039). Age, body mass index, weight changes, race completion status, nonsteroidal anti-inflammatory drug use, and urine specific gravity were not associated with the development of EAH. Lower postrace [Na+] levels were associated with higher serum creatine kinase values (R2=0.1, p<0.005). [Conclusion] High altitude (3,840 m peak) does not appear to enhance the incidence of EAH after an ultramarathon footrace. This suggests that ambient temperature (low temperatures reduce risk), sex (female predilection), endurance running, and overhydration are more prominent risk factors for EAH than high altitude.

MCPCB의 온도에 따른 고출력 LED의 광학적, 열적 영향력 분석 (Optical and Thermal Influence Analysis of High-power LED by MCPCB temperature)

  • 이승민;양종경;조주웅;이종찬;박대희
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2276-2280
    • /
    • 2008
  • In this paper, we present thermal dependancy of LED package element by changing temperature of MCPCB for design high efficiency LED lamp, and confirmed influence of LED chip against temperature with analysis of thermal resistance and thermal capacitance. As increasing temperature, WPOs were decreased from 25 to 22.5 [%] and optical power were also decreased. that is decreased reason of optical power that forward voltage was declined by decrease of energy bandgap. Therefore optical power by temperature of MCPCB should consider to design lamp for street light and security light. Moreover, compensation from declined optical efficiency is demanded when LED package is composed. Also, thermal resistances from chip to metal PCB were decreased from 12.18 to 10.8[$^{\circ}C/W$] by changing temperature. Among the thermal resistances, the thermal resistance form chip to die attachment was decreased from 2.87 to 2.5[$^{\circ}C/W$] and was decreased 0.72[$^{\circ}C/W$] in Heat Slug by chaning temperature. Therefore, because of thermal resistance gap in chip and heat slug, reliability and endurance of high power LED affect by increasing non-radiative recombination in chip from heat.

내장형 레귤레이터 및 솔레노이드 개발 (Development of In-tank Pressure Regulator and Solenoid Valve)

  • 이준혁;임태호;김경남;심상학
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.188-191
    • /
    • 2007
  • This paper shows the Development of In-tank pressure regulator and Solenoid Valve used in FCV(Fuel Cell Vehicle). We have developed new type of Regulator and Solenoid through analysis of the structure and characteristics of component of FCS(Fuel Cell System) from the advanced technology. Now it is possible to localize the component by making use of the development of Regulator and Solenoid made by us. Regulator and Solenoid is a equipment to control hydrogen pressure supplied into a stack. Therefore, outlet pressure, a flow of fluid and temperature are important parameters according to a inlet pressure. And leak test, endurance test and burst test should be done to guarantee the performance and safety of Regulator and Solenoid used in the fuel of high pressure. Also, Hydrogen friendly materials are applied to inner parts of the Regulator, Solenoid and weight reduction is done to cost saving in part not related to performance. As a result, we have proven the good performance and reliability in endurance of Regulator, Solenoid and will make an development in performance as well as durability to ensure industrialization.

  • PDF

레이저 출력에 따른 레이저예열선삭된 질화규소의 기계적 특성 (Mechanical Properties of Silicon Nitride Laser-Assisted Machined by Laser Power)

  • 김종도;이수진;신동식;서정;이제훈
    • 한국레이저가공학회지
    • /
    • 제12권4호
    • /
    • pp.12-16
    • /
    • 2009
  • The engineering ceramic is one of the materials advantageous in various conditions with high strength, endurance at high temperature, abrasion resistance and corrosion resistance, etc. However, due to high strength and high brittleness, ceramic incurs high costs and long time on finishing process required after sintering. So a process for obtaining wanted measurements of them has been studied using the high temperature which makes ceramics softened and heat affected recently. This study makes an estimate of laser-assisted machining (LAM) if an economically practical process for manufacturing precision silicon nitride ceramic parts using laser beam. In this study, mechanical properties of silicon nitride at high temperature were observed. And during the LAM, it was observed that cutting force and tool wear were reduced and oxidation of machined surface was increased according to a increase of laser power.

  • PDF

7톤급 터보펌프 기계평면실의 성능 시험 연구 (Study on the Mechanical Face Seal Performance for a 7-ton-Class Turbopump)

  • 배준환;곽현덕;최창호
    • Tribology and Lubricants
    • /
    • 제32권5호
    • /
    • pp.154-159
    • /
    • 2016
  • This paper presents an experimental study of the leakage performance and endurance performance of a mechanical face seal in the 7-ton-class turbopump of the Korea Space Launch Vehicle 2 third-stage engine. We install a mechanical face seal between the fuel pump and turbine to prevent the mixing of the fuel and turbine gas. We design and manufacture a prototype mechanical face seal, which has two parts, namely, a bellows seal assembly and mating ring. We set up a test facility to measure the leakage and endurance of the mechanical face seal. For the similarity tests, we use water under real operating conditions such as high rotational speed, high temperature, and high pressure. Through investigation of the leakage and carbon wear rate, it is possible to evaluate the performance of the mechanical face seal. The results of the leakage and endurance performance test demonstrate the absence of any leakage from the prototype mechanical face seal after a trial run and clarify that the acceptable wear rate fully satisfies the turbopump requirements. Finally, we install a qualified mechanical face seal in a 7-ton-class turbopump and perform a validation test in the turbopump real-propellant test facility in the Korea Aerospace Research Institute. The test results confirm that the mechanical face seal works well under real operating conditions.

촉매연소 시스템 안정화 : 고온용 열교환기를 이용한 능동제어 (Catalytic Combustion System Stability : Active Centre with High Temperature Heat Exchanger)

  • 유상필;송광섭;류인수
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.133-140
    • /
    • 2002
  • Catalytic combustion known as one of the traditional oxidation methods of VOC gas is restricted to its applicable fields because of its reaction characteristics. But recently innovative improvement of catalytic endurance makes its applicable range broader from MEMs to industrial power generation. Therefore, control technologies based on the catalytic combustion characteristics are researched and developed dynamically. Especially, the stable control of catalytic combustion is an essential factor in a view of maximizing its efficiency. In this research, the fuel equivalence ratio and the preheating temperature of mixture gas is controlled by catalytic combustion system enhanced in heat transfer with high temperature heat exchanger. As a result the combustion characteristics of system was investigated, and both passive and active control type were compared and analyzed.

  • PDF