• Title/Summary/Keyword: High-temperature design

Search Result 2,757, Processing Time 0.031 seconds

A Study on the Effect of Experimental Factors for the Durability Inspection of High Strength Concrete (고강도콘크리트의 내구성진단을 위한 영향인자 파악을 위한 연구)

  • Kwon, Young-Jin;Kim, Moo-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.2
    • /
    • pp.123-130
    • /
    • 1997
  • The effect of experimental factors on the Freeze-Thaw durability in the High Strength Concrete has been analyzed and investigated with [DESIGN of EXPERIMENT: L16). The Experimental parameters included the type of aggregate and mixer, the conditions of aggregates, and the difference of mixing temperature, procedure and placing, etc. It is aim of this study to provide the fundamental data on the effect of various factors on the frost resistance of high strength concrete for the practical use and research data accumulation of durability inspection. The results of this experiment indicate that the freeze-thaw durability of high strength concrete is markedly affected by the coarse aggregate source, mixing temperature and curing conditions.

  • PDF

Research on Insulation Design of the Bushing for a 154kV Class HTS Transformer (154kV급 고온초전도 변압기용 부싱의 절연설계에 관한 연구)

  • Kwag, D.S.;Cheon, H.G.;Choi, J.H.;Kim, H.J.;Yun, M.S.;Kim, Y.S.;Kim, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.216-217
    • /
    • 2006
  • A common problem in many fields of cryogenic power engineering is to apply high voltage to cold parts of superconducting equipment. In many of these cases a bushing provides electrical insulation for the conductor which makes the transition from ambient temperature to the cold environment. The cryogenic high voltage bushing for the 154kV, 100MVA high temperature superconducting(HTS) transformer is described. The bushing is energized with the line-to-ground voltage between the coaxial center and outer surrounding conductors, in the axial direction there is a temperature difference from ambient to about 77 K. For the insulation design of cryogenic bushing, the arrangement of condenser cone and electrical insulation characteristics of GFRP, Air, $LN_2$ and $GN_2$ were discussed in this paper.

  • PDF

Life Expectation of Salt Attack for Fire Damaged RC Structure (화재피해를 입은 콘크리트 건축물의 염해 내구수명 산정)

  • Park, Dong-Cheon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.15-16
    • /
    • 2017
  • The properties of concrete damaged by fire change according to the temperature. Diffusion coefficient of chloride ion also can change which affect the life expectation under salt circumstance. Diffusion coefficient was measured by NT BUILD 492 using the concrete specimen damaged by high temperature. FEM analysis was performed to predict the life expectancy which can help to diagnose the concrete diagnose and to design maintenance strategy.

  • PDF

NUMERICAL ANALYSIS TO DESIGN HIGH TEMPERATURE HEAT EXCHANGER OF BETA TYPE STIRLING ENGINE IN 3-D COMBUSTION FIELD (3차원 연소장에서의 베타 형태의 스털링엔진 고온 열교환기 설계를 위한 수치해석 연구)

  • Kang, S.H.;Kim, H.J.;Chung, D.H.
    • Journal of computational fluids engineering
    • /
    • v.16 no.2
    • /
    • pp.56-61
    • /
    • 2011
  • Numerical study is conducted to design the high temperature heat exchanger of Stirling engine by using the commercial CFD solver, FLUENT. The Fin-tube type of heat exchanger is designed as a reference model by considering the type of engine which is ${\beta}$-configuration. To find the optimal design of heat exchanger in heat transfer capacity numerical calculation is conducted by changing the shape, the number, and material of reference model in three-dimensional combustion field. Adjusted one-way constant velocity of working fluid that is helium is considered as the representative velocity of oscillating flow. The optimal design of heat exchanger considering the heat transfer capability is suggested by using the calculation results.

Implementing Database for Designing Super High Temperature Vacuum Furnace (초고온 진공로 설계를 위한 데이터베이스 구축)

  • Kim, Jong-Hwa;Do, Sang-Yun;Lee, Jae-U;Jeong, Gap-Ju
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.05a
    • /
    • pp.273-276
    • /
    • 2004
  • Multidisciplinary Design Optimization (MDO) is an individual and parallel design framework applied in designing large and complex systems. for successful implementation of MDO framework it is essential to manage data in efficient and integrated manner. In this study, we present a case study to implement database to support designing super high temperature vacuum furnace with MDO technology. For that purpose we first extract required data based on the analysis of design process and then data flows between different programs are analyzed. Finally an E-R diagram is presented to design database schema.

  • PDF

Integrated Expansion Analysis of Pipe-In-Pipe Systems

  • Choi, Han-Suk;Do Chang-Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.5 s.72
    • /
    • pp.9-14
    • /
    • 2006
  • This paper presents an analytical method, application of expansion, mechanical design, and integrated expansion design of subsea insulated pipe-in-pipe (PIP) systems. PIP system consists of a flowline and a casing pipe for the transport of high temperature and high pressure product from the subsea wells. To prevent heat lass from the fiowline, insulation material is applied between the pipes. The fiawline pipe and the casing pipe have mechanical connections through steel ring plate (water stops) and bulkheads. Pipeline expansion is defined by temperature, internal pressure, soil resistance, and interaction force between the flowline and the casing pipe. The results of the expansion analysis, the mechanical design of connection system of the two pipes and tie-in spool design are integrated for the whole PIP system.

Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling (HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구)

  • 박재홍;권용하;김영수;박성출
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.2
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

Insulation Design and Testing of HTS coil for 6.6 kV Class HTSFCL (6.6kV급 고온초전도 한류기용 HTS 코일의 절연 설계 및 시험)

  • 백승명;정종만;곽동순;류엔반둥;김상현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.263-268
    • /
    • 2003
  • The Electrical insulation design and testing of high temperature superconducting (HTS) coil for high temperature superconducting fault current limiter (HTSFCL) has been performed. Electrical insulating factors of HTS coil for HTSFCL are turn-to-turn, layer-to-layer. The electrical insulation of turn-to-turn depends on surface length, and the electrical insulation of layer-to-layer depends on surface length and breakdown strength of L$N_2$. Therefore, two basic characteristics of breakdown and flashover voltage were experimentally investigated to design electrical insulation for 6.6㎸ Class HTSFCL. We used Weibull distribution to set electric field strength for insulation design. And mini-model HTS coil for HTSFCL was designed by using Weibull distribution and was manufactured to investigate breakdown characteristics. The mini-model HTS coil had passed in AC and Impulse withstand test.

  • PDF

Design Evaluation of Heavy Duty Heat Exchangers for Compact Steam Boilers (밀집형 증기보일러의 고부하 열교환기 설계평가)

  • Kim, Sungil;Yang, Jongin;Choi, Sangmin
    • Journal of the Korean Society of Combustion
    • /
    • v.18 no.2
    • /
    • pp.23-31
    • /
    • 2013
  • Compact steam boiler is a useful heat exchanger in a space-intensive system. There are some constraints in terms of sizing and designing the space confined in the system which is usually used in vessels. In this study, design considerations for heavy duty heat exchangers of compact steam boilers are presented and evaluated. Especially, evaporator tubes of marine boiler which are exposed to a high temperature environment are considered. Also, extended surface designs with a high temperature are examined. In order to determine the criteria with considerations of both heat transfer rate and pressure drop in the heat exchanger, they are evaluated with major variables, such as the tube diameter, the number of tubes, and the tube length. Finally, the design parameters are estimated as the bare tubes are installed instead of the finned tubes.