• 제목/요약/키워드: High-strength re-bar

검색결과 28건 처리시간 0.024초

초고강도 철근이음의 경제성 평가모델 개발에 관한 연구 (A Study on the Economic Evaluation Model of Splice of Reinforcement Bar(SD500))

  • 김재엽;김대원
    • 한국건축시공학회지
    • /
    • 제8권1호
    • /
    • pp.71-76
    • /
    • 2008
  • Recently, the high-rise apartment housings have become a prototype of the urban residential dwelling in Korea and the numbers of one have steadily been increasing. According to this trend, the strength of the construction materials is also fortified to assure the stability and durability of the buildings. Specially, Re-bar of SD500 type is largely used at the construction sites of high-rise building. This study analyzes the current usage of SD500 high-strength re-bar at domestic construction sites. Through the result of this analysis, we develop Economic Evaluation Model that measure economic efficiency of lap splice and coupler splice, which are most commonly used in connection SD500. The evaluation method was applied to construction sites in Seoul in December 2006, and the result revealed that coupler splice is relatively superior in terms of cost efficiency when the re-bar diameter is longer and the concrete strength is lower.

고강도콘크리트에서 폴리머 시멘트 슬러리 도장철근의 인발부착특성 (Pull-Out Bond Properties of Polymer Cement Coated Rebars in HSC)

  • 김민호;김완기;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.215-220
    • /
    • 2002
  • Epoxy-coated re-bar was partly used to the structures and put to practical use, but were not economical and appeared to have defects such as the diminishing of long term bond strength between concrete. The study of polymer cement slurry coated re-bar was started in order to complement the defect of epoxy coated re-bar, and ever since the basic properties appeared to be excellent. But, study of bond properties embedded in concrete specimens was insufficient until now. This study attempts to examine the possibility of improving the bond strength of polymer cement slurry coated re-bar between concrete specimens in accordance with ACI Code and KS Code through pull-out test of 150mm$\times$150mm$\times$150mm substrates with polymer cement slurry coated re-bar having polymer cement ratios of 50%, 75% and 100%, coating thickness 250${\mu}{\textrm}{m}$, 450 ${\mu}{\textrm}{m}$ and with curing ages of 3, 7 and 28 days. High strength concrete was designed having a compressive strength of 500kgf/cm2 as specified. Practical bond length ranges of 55 and 85mm were applied to each of specimen. The bond strength of polymer cement slurry coated re-bar using St/BA-1 and St/BA-2 was compared to that of plain re-bar. The results of this study showed that the bond strength of 55mm bond length was much higher than that of 85mm bond length.

  • PDF

SD500철근 커플러 이음의 편익/비용분석에 관한 연구 (A Study on Benefit/Cost Analysis of Re-Bar Connection Methods for Hyper Strength(SD500) Reinforcement)

  • 김재엽;권여울;김준영
    • 한국건축시공학회지
    • /
    • 제8권2호
    • /
    • pp.81-87
    • /
    • 2008
  • High-rise building is taking a place as one of building types from apartment housings to commercial buildings. With taking in account of stability and durability, strength of used materials is increasing gradually in these high-rise buildings. According to this, frequency in use of SD500 re-bar is increasing gradually in high-rise buildings. However the study of SD500 re-bar is insufficient because SD500 re-bar started to be used for domestic buildings lately. Specially because there is no guide or study to refer to, people get into difficulties when to decide the method of re-bar connection in construction using SD500 re-bar. Accordingly in this study, it suggests the method of estimating the economical efficiency on SD500 re-bar connection, and conducts benefit/ cost analysis on lapped splice and coupler splice by applying AHP theory, and then presents its result. After to analyze re-bar diameter of D25, 29, and 32, finally we attained the result that the coupler splice is advantageous in all parts of benefit/ cost more than the lapped splice.

고강도 철근용 충전형 기계적 이음장치 개발 연구 (Development of Filler Type Mechanical Splice for High Strength Re-bar)

  • 이성수;전호민
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.686-693
    • /
    • 2018
  • 철근 콘크리트 구조물에 다양한 종류의 철근 이음 방법이 개발되고 이를 현장에서 적용하여 왔다. 지난 여러 연구들에 따르면 철근의 직경이 굵어지고 철근의 강도가 커질 경우, 원가 효율 면에서 기계적 이음이 겹침이음보다 상대적으로 우수한 것으로 나타났다. 본 연구에서는 철근 콘크리트 구조물의 고강도 철근(SD600)에 대한 에폭시 충전형 기계적 이음장치를 제시하고 실험을 실시하였다. 이형 철근을 원형 튜브형 강재로 된 커플러에 삽입하고 고강도 에폭시 충전재를 커플러 안으로 주입하면 커플러 안에서 충전재가 경화되면서 이음 장치가 구성된다. 에폭시의 압축강도, 커플러의 길이, 철근의 지름 등에 따른 에폭시 충전형 기계적 이음장치에 대한 일방향 인장시험을 수행하였으며, 실험체의 파괴하중 및 파괴 양상을 관찰하였다. 실험 결과, 실험체의 실제 파괴하중은 에폭시 충전재의 예상 파단 내력의 약 2배 이상으로 나타나 강재 커플러의 구속으로 인하여 경화 에폭시 충전재의 파괴하중이 크게 증가했다는 것을 확인하였다.

원전구조물의 확대머리 고강도철근 적용기술 개발 (The Technology Development for applying the High Strength Headed Deformed Bar to the Nuclear Power Plant Structures)

  • 이병수;방창준;이한우;임상준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.273-275
    • /
    • 2013
  • If the mechanical development is applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the yield strength and diameter of the re-bar. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF

원전구조물 고강도철근 모듈화를 위한 적용방법 연구 (Study of application method for the Rebar Modulation of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 임상준;이병수;방창준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.17-18
    • /
    • 2013
  • To minimize construction of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop appication design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are. This study is to introduce application method for the Rebar Modulation of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures.

  • PDF

원전구조물 고강도철근 모듈화를 위한 용접방법 성능평가 (Performance Evaluation of Welding Method for Modular of High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 임상준;이한우;김형섭;방창준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.278-280
    • /
    • 2013
  • To minimize construction quantity of nuclear facility, it is required to reduce reinforcing bar amount and solve reinforcing bar concentration and for this, it is necessary to develop application design technology and modular of high strength reinforcing bar. Hence, KHNP reduces excessive reinforcing bar amount which can cause possibility of poor construction of concrete through design standard development and modular of nuclear facility structure using high strength reinforcing bar to raise economics and has its purpose to maintain high-level safety and durability as they are.

  • PDF

SD500 고강도 철근용 커플러이음의 경제성 평가에 관한 연구 (A Study on Economic Evaluation Method of Coupler Splice for High Strength(SD500) Reinforcement)

  • 김재엽;김광희
    • 한국건설관리학회논문집
    • /
    • 제8권2호
    • /
    • pp.136-145
    • /
    • 2007
  • 우리나라의 초고층 건축물은 초고층아파트가 대도시 주거건축의 대표적인 유형으로 등장하면서 점차 증가하고 있다. 최근 건축되고 있는 이러한 초고층 건축물에서는 건물의 안정성과 내구성 등을 감안하여 사용재료의 강도도 점차 증가하고 있다. 이에 따라 철근의 경우 SD500철근을 사용하는 공사현장을 쉽게 볼 수 있게 되었다. 이에 본 연구에서는 국내의 건축공사에서 사용되는 SD500철근의 사용 실태를 분석하였다. 또한 SD500철근의 이음방법으로 많이 사용되고 있는 겹침이음과 커플러이음에 대한 경제성 평가방법을 제안하고, 이를 2006년 12월 서울을 기준으로 평가하였다. 경제성 평가 결과, 커플러 이음은 철근직경이 클수록 콘크리트의 강도가 낮을수록 겹침이음에 비해 공사비용 측면에서 상대적으로 유리한 것으로 분석되었다.

콘크리트 보강용 고연성 하이브리드 FRP 보강근의 인장 및 파괴 특성 (Tensile Behavior and Fracture Properties of Ductile Hybrid FRP Reinforcing Bar for Concrete Reinforcement)

  • 박찬기;원종필
    • 한국농공학회논문집
    • /
    • 제46권1호
    • /
    • pp.41-51
    • /
    • 2004
  • FRP re-bar in concrete structures could be used as a substitute of steel re-bars for that cases in which aggressive environment produce high steel corrosion, or lightweight is an important design factor, or transportation cost increase significantly with the weight of the materials. But FRP fibers have only linearly elastic stress-strain behavior; whereas, steel re-bar has linear elastic behavior up to the yield point followed by large plastic deformation and strain hardening. Thus, the current FRP re-bars are not suitable concrete reinforcement where a large amount of plastic deformation prior to collapse is required. The main objectives of this study in to evaluate the tensile behavior and the fracture mode of hybrid FRP re-bar. Fracture mode of hybrid FRP re-bar is unique. The only feature common to the failure of the hybrid FRP re-bars and the composite is the random fiber fracture and multilevel fracture of sleeve fibers, and the resin laceration behavior in both the sleeve and the core areas. Also, the result of the tensile and interlaminar shear stress test results of hybrid FRP re-bar can provide its excellent tensile strength-strain and interlaminar stress-strain behavior.

고강도철근 기계적정착의 원전구조물 적용을 위한 성능평가실험 (Performance Evaluation Test for Applying the Mechanical Development of the High-Strength Reinforcing Bars to the Nuclear Power Plant Structures)

  • 이병수;방창준;임상준;김석철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.197-198
    • /
    • 2012
  • If the mechanical development be applied to the Nuclear Power Plant Structures instead of the standard hook development, the problem of overcrowding re-bars in the anchorage zone can be solved and the construction quality of the concrete work will be improved. But there are some problems in applying it to the NPP structures because of the restriction on the re-bar yield strength and diameter. After the performance evaluation test for the mechanical development, we can develop the new design equation of the mechanical development length in order to solve the limitation and apply it to NPP structures.

  • PDF