• Title/Summary/Keyword: High-rise building fire

Search Result 266, Processing Time 0.027 seconds

Vertical Evacuation Speed in Stairwell of a High-rise Office Building (업무용 고층건물 계단실의 보행속도에 관한 연구)

  • Joung, Suck-Hwan;Yoon, Myong-Oh
    • Fire Science and Engineering
    • /
    • v.29 no.3
    • /
    • pp.13-20
    • /
    • 2015
  • As building height is increased, more careful decisions about the required safe egress time is needed for evacuation. This study analyzed the influence of three training sessions on the vertical speed of evacuation in the high rise building. Evacuation experiments were done in a high-rise office building in Seoul, and we analyzed the vertical evacuation speed as a function of density using a camera. Controlled and uncontrolled total evacuation were compared using the Pathfinder simulation. The process of repeated training, changed the specific stair utilization rate from 6.3% to 39.5%. The vertical evacuation speed as a function of density was analyzed using the equation s = 1.004 ? 0.288D, which is very similar to the equation used in a different study. The total evacuation time of the special controlled total evacuation was reduced by about 25% compared to the simultaneous evacuation.

A study on the simulator development for fire evacuation of the high-rise buildings (초고층 건물의 화재 대피 시뮬레이터 개발에 관한 연구)

  • 박양수;임동진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.308-308
    • /
    • 2000
  • In case of fire in the high-rise buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the floor plans of the buildings, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error In this study, the simulator model is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most safe evacuation plans for the residents in case of fire.

  • PDF

A Study on the planning improvement of sprinkler and other safety facility in high rise apartment building (고층 공동주택의 스프링클러 및 기타 안전설비 설계개선에 관한 연구)

  • 이영재;권오승;김굉일;윤명오
    • Fire Science and Engineering
    • /
    • v.5 no.3
    • /
    • pp.31-35
    • /
    • 1991
  • Under the present code, sprinkler heads operating simultaneously are fixed at 30 in number, irrelavant to building use. But, apartment buildings in korea have mostly wall-and-slab structure and every house hold is separated by fire-proof wall. Therefore, apropriate review about present system should be made for the safety assurance by reasonable effort.

  • PDF

Flammability and Multi-objective Performance of Building Façades: Towards Optimum Design

  • Bonner, Matthew;Rein, Guillermo
    • International Journal of High-Rise Buildings
    • /
    • v.7 no.4
    • /
    • pp.363-374
    • /
    • 2018
  • The façade is an important, complex, and costly part of a building, performing multiple objectives of value to the occupants, like protecting from wind, rain, sunlight, heat, cold, and sound. But the frequency of façade fires in large buildings is alarming, and has multiplied by seven times worldwide over the last three decades, to a current rate of 4.8 fires per year. High-performing polymer based materials allow for a significant improvement across several objectives of a facade (e.g., thermal insulation, weight, and construction time) thereby increasing the quality of a building. However, all polymers are flammable to some degree. If this safety problem is to be tackled effectively, then it is essential to understand how different materials, and the façade as a whole, perform in the event of a fire. This paper discusses the drivers for flammability in facades, the interaction of facade materials, and current gaps in knowledge. In doing so, it aims to provide an introduction to the field of façade fires, and to show that because of the drive for thermal efficiency and sustainability, façade systems have become more complex over time, and they have also become more flammable. We discuss the importance of quantifying the flammability of different façade systems, but highlight that it is currently impossible to do so, which hinders research progress. We finish by putting forward an integral framework of design that uses multi-objective optimization to ensure that flammability is minimized while considering other objectives, such as maximizing thermal performance or minimizing weight.

내화피복 강재의 내화성능 평가 예측에 관한 연구

  • Seong, Si-Chang
    • Fire Protection Technology
    • /
    • s.17
    • /
    • pp.5-9
    • /
    • 1994
  • With a rapid development of economy, more high-rise buildings are being constructed in large cities than before. As a result steel members such as beams, columns make a great role of the building construction, and the need of them to be protected to have enough fire resistance is in-creasing . But conducting a real fire test to all the members is almost impossible. So prior to do conduct a real fire test of the protected steel members, evaluating the fire resistant rating of them by means of their specific properties might be economical things. This study is aimed to introduce the fire resistant rating of protected steel members without a real fire test through the related studies and data.

  • PDF

Fire & Life Safety Challenges in Sustainable Tall Building Design

  • Li, Fang;Reiss, Martin
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • The movement towards sustainable building design can result in unique fire protection challenges and concerns, especially with super tall buildings in relationship to traditional prescriptive code compliance. Different countries haves different code requirements as well as local best practices and may cause conflict with the design features when designing green buildings. These include, but not limited to green roofs, sprinkler water quality and testing, fire department access and areas of refuge with direct or indirect impact by the perspective code compliance. The solutions to these prescriptive code challenges and fire safety concerns can range from simple alternatives to more detailed engineering performance-based design analyses with good solid practice.

A study on the planning for fire evacuation of the high-rise buildings using the fire evacuation simulator (화재 대피 시뮬레이터를 이용한 초대형 고층 건물의 화재 대피 계획에 관한 연구)

  • Park, Yang-Soo;Lim, Dong-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2000.11d
    • /
    • pp.618-620
    • /
    • 2000
  • In case of fire in the high-rise buildings, the appropriate and safe evacuation plans for the building residents are very important to minimize the number of casualties. Since the evacuation time usually depends on the floor plans of the buildings, the evacuation plans should be considered while the architectural design is done. Conventionally, the calculation of the evacuation time in the case of fire breakout is based on the approximate mathematical equations which are prone to error. In this study, the simulator model is developed to help the architectural designers to access the more accurate evacuation time and find out the floor plans which offers the most safe evacuation plans for the residents in case of fire.

  • PDF

Bond Strength of Light-weight Inorganic Ceramic Board for Fire Resistant Curtain-wall System (커튼월 층간 화재확산방지구조 적용을 위한 경량무기발포 세라믹보드의 부착강도)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.214-215
    • /
    • 2014
  • Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. This study is explain fire resistance performance of the curtain walls. And focused on bond strength of light-weight inorganic ceramic board in high temperature for fire resistant curtain-wall system. From the result, curtain-wall system high fire resistant using the light-weight inorganic ceramic board.

  • PDF

A Study on the Fire Reconstruction of Exterior on High-rise Building (Focus on Fire Case Including the Woosin Golden Suite in Haeundae) (고층 건축물 외장재의 화재 재현에 관한 연구 (해운대 우신골든스위트의 화재사례를 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.25-30
    • /
    • 2013
  • 'Heaundae Woosin Building' fire was the case that a fire breaking out on the $4^{th}$ floor spread out the $38^{th}$ floor which is a top story and the penthouse was destroyed by fire. After this fire, the fire safety for high rise buildings has been on the rise and several new laws and regulations related in the buildings were created. The study is to analyze Heaundae officetel building case using FDS which is one of the CFD programs for fire. The methodology of this study is to analyze the case comparing with fire spread and route from a virtual fire simulation and related articles and a video clip of actual scene fire. This study shows that a fire spreading on top of levels spent approximately 30 minutes and, which is similar to the actual fire case. Also the pattern of spread has similarity with the case. However, even if the actual fire case shows the fire pattern was "V shape", the smoke-view presents the fire dose not spread horizontally as much as the real fire case. The result shows uncertainty of the modeling based on many grids and a limitation of putting interior finish input sources and the direction of the wind might cause the difference. Also, to analyze factors influencing on a vertical fire, another fire modeling is performed by in condition of modeling environment considering concrete interior finish between buildings and no wind. The result presents the fire spread in smoke-view does not spread vertically as much as the actual case.