• 제목/요약/키워드: High-rise building construction

검색결과 721건 처리시간 0.027초

천장 브래킷을 이용한 완전강접합 모듈러 시스템의 구조성능 (Structural Performance of the Modular System with Fully Restrained Moment Connections using Ceiling Bracket)

  • 이승재;곽의신;박재성;강창훈;손수덕
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.37-44
    • /
    • 2017
  • Due to structural characteristics, construction costs and duration of a modular system would be saved by minimizing the schedule on the job site. As such, it is crucial to develop a connection that can guarantee stiffness while allowing for simple assembling. Particularly, the mid- to high-rise construction of the modular system necessitates the securing of the structural stability and seismic performance of multi-unit frames and connections, and thus, the stiffness of unit-assembled structures needs to be re-evaluated and designed. However, evaluating a frame consisting of slender members and reinforcing materials is a complicated process. Therefore, the present study aims to examine the structural characteristics of a modular unit connection based a method for reinforcing connection brackets and hinges while minimizing the loss of the cross section. Toward this end, the study modeled the beam-to-column connection of a modular system with the proposed connection, and produced a specimen which was used to perform a cycling loading test. The study compared the initial stiffness, the attributes of the hysteretic behavior, and the maximum flexural moment, and observed whether the model acquired the seismic performance, compared to the flexural strength of the steel moment frame connection that is required by the Korean Building Code. The test results showed that the proposed connection produced a similar initial stiffness value to that of the theoretical equation, and its maximum strength exceeded the theoretical strength. Furthermore, the model with a larger ceiling bracket showed higher seismic performance, which was further increased by the reinforcement of the plate.

사례분석을 통한 효율적 상향수압(Up-Lift Pressure) 처리공법 적용방안에 관한연구 - ◯◯ 상업지역 현장사례 중심으로 - (A Case study and Analysis on the Up-Lift Pressure Treatment Evaluation of Underground Installations for their Efficient Adoption)

  • 고옥렬;권오철;심재광;박태은
    • 한국건축시공학회지
    • /
    • 제9권4호
    • /
    • pp.119-129
    • /
    • 2009
  • 최근의 건축활동은 초고층화 대형화 복잡화 되고 있으며 도심지내에 근접 시공되어 짐에 따라 건축물의 지상층 높이증가와 더불어 지가의 앙등, 토지이용의 극대화로 지하구조물의 중요성이 증가되고 있으며 지하층의 면적 및 층수가 증가되어 가는 추세이다. 이에 따라 지하굴착심도가 깊어지고 있으며 토지 이용의 효율극대화 측면에서 우리나라의 경우 해안매립지등 매립지반에서의 건축활동이 급증하는 추세로 연약지반에 대한 대책과 아울러 지하수위에 대한 영향을 신중하게 검토해야할 필요성이 증대되고 있는 실정이다. 일반적으로 지하굴착 후 시공되는 건축물은 지층의성상과 토질, 수압 등에 대한 고려로 건물의 최하층 바닥슬라브 하부에 위치하게 되는 지하수위와의 수두압차에 의한 정수학적 압력(Hydrostatic Pressure), 즉 부력(Uplift Water Pressure)이 건물저면에 작용하게 되므로, 이러한 부력(浮力)합리적으로 대처할 수 있는 설계 및 시공법의 개발과 이를 적용하기 위한 노력은 지하층공사에 있어서 안전, 공기, 비용, 건축의질 측면에서 필수적이라고 할 수 있다. 그러나 이제까지의 지하층 공사는 부력 처리방법 등에 대한 연구가 미흡하며 기존의 공법 중 대상 프로젝트의 합리적인 수행을 위한 설계초기단계에서의 지반에 대한 사전조사와 면밀한 분석이 이루어지지 않고, 경험에 의존하는 경향이 크다. 본 연구는 상기와 같은 문제점을 바탕으로 O O 건설현장 실 사례를 중심으로 현장은 한강에 인접한 지리적 요인에 의해 지하수위가 한강의 수위와 연계되어 있는바 최초 계획되었던 Rock anchor System 대신 Drain mat System을 적용하여 유입되는 지하수를 유도, 배수함으로써 지하수위에 따른 상향수압을 통제할 수 있는 최적공법 선정을 통해 직접공사비 406,702,000원 및 Life Cycle Cost 차원에서 검토한 결과 건물수명 50년 기준 절감액 운용수익률 년 4% 절감의 효과로 이는 건설초기단계에서의 과다설계에 따른 투입 공사비의 과다책정, 공기의 증가 등에 따른 채산성 문제를 합리적으로 제어하여 건설공사의 원가절감을 위한 성공사례로 평가되고 있다.

경계조건의 조절에 따른 합성 데크플레이트 슬래브의 거동특성에 관한 연구 (A Study on the Dynamic Characteristics of Composite Deck Plate According to the Modification of Boundary Conditions)

  • 김우영;정은호;엄철환;김희철
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.371-376
    • /
    • 1998
  • As the requirement of high-rise buildings in big cities increases, steel structural system becomes more popular in spite of the relatively higher material cost compared to that of the concrete structural system. Most of the steel structure adopts metal deck floor system because of the easiness in construction. However, the metal deck floor system has a weakness on vibration which became very important factor in office buildings, hotels and residential buildings as the more sensitive machines being used. Therefore, most, of the building codes in many countries restrict the natural frequency of the each floor should be higher than or equal to 15 Hz. Floor vibration of the KEM deck composite floor system which has been , developed recently from the engineers and scientists in Korea was measured. Also, the simplified analytical derivation of natural frequency for each floor was studied according to the measured natural frequency for each different boundary condition of the floor. As the length of the slab gets bigger, the natural frequency of the slab becomes lower even though the structural designer still considers it as a one-way slab.

  • PDF

Load Transferring Mechanism and Design Method of Effective Detailings for Steel Tube-Core Concrete Interaction in CFT Columns with Large-Section

  • Li, Yuanqi;Luo, Jinhui;Fu, Xueyi
    • 국제초고층학회논문집
    • /
    • 제7권3호
    • /
    • pp.223-232
    • /
    • 2018
  • Two novel types of construction detailings, including using the distributive beam and the inner ring diaphragm in the joint between large-section CFT columns and outrigger truss to enhance the transferring efficiency of huge vertical load, and using the T-shaped stiffeners in the steel tube of large-section CFT columns to promote the local buckling capacity of steel tubes, were tested to investigate their working mechanism and design methods. Experimental results show that the co-working performance between steel tube and inner concrete could be significantly improved by setting the distributive beam and the inner ring diaphragm which can transfer the vertical load directly in the large-section CFT columns. Meanwhile, the T-shaped stiffeners are very helpful to improve the local bulking performance of steel tubes in the column components by the composite action of T-shaped stiffeners together with the core concrete under the range of flange of T-shaped stiffeners. These two approaches can result in a lower steel cost in comparison to normal steel reinforced concrete columns. Finally, a practical engineering case was introduced to illustrate the economy benefits achieved by using the two typical detailings.

FDS를 이용한 외장재의 수직 확산 화재의 모델링에 관한 연구 (A Study on the Modeling of Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS))

  • 민세홍;윤정은
    • 대한안전경영과학회지
    • /
    • 제11권2호
    • /
    • pp.77-85
    • /
    • 2009
  • Considering heat insulation and beautiful sight of construction, making use of exterior panels is increasing. Recently the exterior panels now are weak very much, and so in consequence of the weakness fire spreads rapidly. Compared with internal fire, external vertical fire spread rate goes rapidly and it is extensive in spread range, therefore it is dangerous very much. Accordingly, under present condition of poor standard of exterior panels, it is required to take measure to meet the appropriate situation. In this study, by making use of FDS(Fire Dynamic Simulation) program about external vertical fire of high rise building, fire behavior is searched by computer. It is important that realizing by computer fire modeling about external vertical fire must be included certainly in procedure of fire performance design in the future. In modeling program, FDS version 5 is available, and aluminium composite panel is applied in external panels. In this study, for realizing of actual fire condition, FDS is applied by details of fire scenarios considering influence of wind.

고층 건물 유리 외벽 청소용 로봇의 성능에 관한 연구 (A Study on the Performance of Window Cleaning Robots in High-Rise Building)

  • 이진구;김대명;이동주
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.390-396
    • /
    • 2013
  • Due to the development of technology, there is a considerable increase in the number of skyscrapers in the world. Accordingly, there are rapid growing requests about maintenances such as cleaning, painting, and inspection. However, it is extremely dangerous working the walls of buildings, and crashes from buildings have accounted for large proportion of constructional accidents. Especially, as the number of buildings with irregular shapes increases, the accident rate during the maintenance work increases each year, and most of the accidents lead to death. An alternative solution must be developed with the commercialization of automatic systems. In this research, a fundamental research has been conducted for drafting and commercializing an automation tool that is carried in the built-in guide system, which can perform cleaning.

Sensor placement optimization in structural health monitoring using distributed monkey algorithm

  • Yi, Ting-Hua;Li, Hong-Nan;Zhang, Xu-Dong
    • Smart Structures and Systems
    • /
    • 제15권1호
    • /
    • pp.191-207
    • /
    • 2015
  • Proper placement of sensors plays a key role in construction and implementation of an effective structural health monitoring (SHM) system. This paper proposes a novel methodology called the distributed monkey algorithm (DMA) for the optimum design of SHM system sensor arrays. Different from the existing algorithms, the dual-structure coding method is adopted for the representation of design variables and the single large population is partitioned into subsets and each subpopulation searches the space in different directions separately, leading to quicker convergence and higher searching capability. After the personal areas of all subpopulations have been finished, the initial optimal solutions in every subpopulation are extracted and reordered into a new subpopulation, and the harmony search algorithm (HSA) is incorporated to find the final optimal solution. A computational case of a high-rise building has been implemented to demonstrate the effectiveness of the proposed method. Investigations have clearly suggested that the proposed DMA is simple in concept, few in parameters, easy in implementation, and could generate sensor configurations superior to other conventional algorithms both in terms of generating optimal solutions as well as faster convergence.

Boundary Conditions and Fire Behavior of Concrete Filled Tubular Composite Columns

  • Rodrigues, Joao Paulo C.;Correia, Antonio J.M.;Kodur, Venkatesh
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.313-325
    • /
    • 2018
  • Concrete-filled steel tubular (CFST) members are commonly used as composite columns in modern construction. However, the current guidelines for members' fire design (EN1994-1-2) have been proved to be unsafe in case the relative slenderness is higher than 0.5. In addition, the simplified design methods of Eurocode 4 are limited to circular and square CFST columns, while in practice columns with rectangular and elliptical hollow sections are being increasingly used because of their architectural aesthetics. In the last years a large experimental research has been carried out at Coimbra University on the topic. They have been tested concrete filled circular, square, rectangular and elliptical hollow columns with restrained thermal elongation. Some parameters such as the slenderness, the type of cross-section geometry as well as the axial and rotational restraint of the surrounding structure to the column have been tested in order to evaluate their influence on the fire resistance of such columns. In this paper it is evaluated the influence of the boundary conditions (pin-ended and semi-rigid end-support conditions) on the behavior of the columns in case of fire. In these tests it could not be seen a marked effect of the tested boundary conditions but it is believed that the increasing of rotational stiffness increases the fire resistance of the columns.

Online automatic structural health assessment of the Shanghai Tower

  • Zhang, Qilin;Tang, Xiaoxiang;Wu, Jie;Yang, Bin
    • Smart Structures and Systems
    • /
    • 제24권3호
    • /
    • pp.319-332
    • /
    • 2019
  • Structural health monitoring (SHM) is of great importance to super high-rise buildings. The Shanghai Tower is currently the tallest building in China, and a complete SHM system was simultaneously constructed at the beginning of the construction of the tower. Due to the variety of sensor types and the large number of measurement points in the SHM system, an online automatic structural health assessment method with few computations and no manual intervention is needed. This paper introduces a structural health assessment method for the Shanghai Tower that uses the coefficients of an autoregressive (AR) time series model as structural state indicators. An analysis of collected data indicates that the coefficients of the AR model are affected by environmental factors, and the principal component analysis method is used to remove the influence of environmental factors. Finally, the control chart method is used to track the changes in structural state indicators, and a plan for online automatic structure health state evaluation is proposed. This method is applied to long-term acceleration and inclination data from the Shanghai Tower and successfully identifies the changes in the structural state. Overall, the structural state indicators of the Shanghai Tower are stable, and the structure is in a healthy state.

고강도 철근 사용에 따른 순수 철근량에 대한 정착 및 이음 철근량 비교 (Comparison of Pure Reinforcement Quantity to Development & Splice Reinforcement Quantity using High-strength Reinforcing Bars)

  • 조승호;나승욱;노영숙
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.72-80
    • /
    • 2018
  • 초고층 및 장경간 등 대형 구조물에 대한 시공시 부재의 품질이 저하될 정도로 과다한 철근이 배근되고 있다는 문제점이 제기되고 있으며, 최근 건축되고 있는 초고층 건축물에서는 건물의 안정성과 내구성 등을 감안하여 사용 재료의 강도도 점차 증가하고 있다. 초고층 및 장경간 구조물의 시공에서 고강도 철근을 사용할 경우 기존의 일반 강도 철근에 비해 배근량 감소로 인하여 부재에서 배근 간격에도 여유를 줄 수 있어 시공성 향상, 공기단축, 접합부 상세가 간소화 되는 장점이 있다. 이 연구에서는 SD500, SD600 철근을 국내에서 설계되었거나 시공되어진 라멘 구조 형식의 지하주차장 건축물에 적용하여 각 부재별로 철근의 강도에 따른 순수 철근량에 대한 정착 및 이음 철근량 증감을 비교 분석한 결과 다음과 같은 결론을 얻었다. 계산된 철근의 정착 및 이음 물량은 사용철근의 강도가 증가함에 따른 정착 및 이음길이의 증가량과 순수 물량의 감소비율, 사용철근의 직경이 줄였을 때의 단면적 감소 등의 요인들에 의해 정착 및 이음 물량이 결정되었으며, 전체적으로 순수 물량에 대한 정착 및 이음 물량의 비율이 SD400대비 SD500의 경우는 증가하였지만 SD500대비 SD600의 경우는 감소하였다. 이는 보의 정착 및 이음 물량이 전체 정착 및 이음 물량에 미치는 영향이 크기 때문으로 판단된다. 한편 순수 물량에 대한 정착 및 이음 물량의 비율에서 SD400과 SD500의 차이와 SD400과 SD600의 차이가 미미하여 철근의 정착 및 이음 물량이 강도 증가에 따른 전체 철근 물량의 증감에는 큰 영향을 주지 않는 것으로 파악되었다.