• Title/Summary/Keyword: High-rise building construction

Search Result 721, Processing Time 0.027 seconds

ITZ Analysis of Cement Matrix According to the Type of Lightweight Aggregate Using EIS (EIS를 활용한 경량골재 종류별 시멘트 경화체의 계면특성 분석)

  • Kim, Ho-Jin;Jung, Yoong-Hoon;Bae, Je-Hyun;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.498-505
    • /
    • 2020
  • Aggregate occupies about 70-85% of the concrete volume and is an important factor in reducing the drying shrinkage of concrete. However, when constructing high-rise buildings, it acts as a problem due to the high load of natural aggregates. If the load becomes large during the construction of a high-rise building, creep may occur and the ground may be eroded. Material costs increase and there are financial problems. In order to reduce the load on concrete, we are working to reduce the weight of aggregates. However, artificial lightweight aggregates affect the interface between the aggregate and the paste due to its higher absorption rate and lower adhesion strength than natural aggregates, affecting the overall strength of concrete. Therefore, in this study, in order to grasp the interface between natural aggregate and lightweight aggregate by type, we adopted a method of measuring electrical resistance using an EIS measuring device, which is a non-destructive test, and lightweight bone. The change in the state of the interface was tested on the outside of the material through a blast furnace slag coating. As a result of the experiment, it was confirmed that the electric resistance was about 90% lower than that in the air-dried state through the electrolyte immersion, and the electric resistance differs depending on the type of aggregate and the presence or absence of coating. As a result of the experiment, the difference in compressive strength depending on the type of aggregate and the presence or absence of coating was shown, and the difference in impedance value and phase angle for each type of lightweight aggregate was shown.

Experimental Study on the Cyclic Behavior of Modular Building with Strap Braced Load Bearing Steel Stud Walls (스트랩 브레이스를 갖는 내력벽식 모듈러건축 스틸스터드 벽체의 반복하중에 대한 거동 연구)

  • Lee, Doo Yong;Cho, Bong Ho;Kim, Tae Hyeong;Ha, Tae Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.415-425
    • /
    • 2016
  • Load-bearing steel stud wall system is widely used for the middle-to-high rise modular buildings worldwide. Seismic performance is a key issue to apply load-bearing steel stud wall system to modular buildings in Korea. This study proposes a new strap braced steel stud wall system with enhanced seismic performance and design equations considering the flexural behaviour of the vertical outer studs. For the verification, two specimens with different strap braces and vertical outer stud were designed and tested. The test results showed that the total strengths were evaluated to be 1.11 to 1.18 times higher than the predicted values. Usually strap braced walls are considered to have low energy dissipation capacities. The proposed system showed enhanced seismic performance with equivalent damping of 9.42% due to the reduced pinching effects.

Seismic response variation of multistory base-isolated buildings applying lead rubber bearings

  • Islam, A.B.M. Saiful;Al-Kutti, Walid A.
    • Computers and Concrete
    • /
    • v.21 no.5
    • /
    • pp.495-504
    • /
    • 2018
  • The possibility of earthquakes in vulnerable regions indicates that efficient technique is required for seismic protection of buildings. During the recent decades, the concept is moving towards the insertion of base isolation on seismic prone buildings. So, investigation of structural behavior is a burning topic for buildings to be isolated in base level by bearing device. This study deals with the incorporation of base isolation system and focuses the changes of structural responses for different types of Lead Rubber Bearing (LRB) isolators. A number of sixteen model buildings have been simulated selecting twelve types of bearing systems as well as conventional fixed-base (FB) scheme. The superstructures of the high-rise buildings are represented by finite element assemblage adopting multi-degree of freedoms. Static and dynamic analyses are carried out for FB and base isolated (BI) buildings. The dynamic analysis in finite element package has been performed by the nonlinear time history analysis (THA) based on the site-specific seismic excitation and compared employing eminent earthquakes. The influence of the model type and the alteration in superstructure behavior of the isolated buildings have been duly assessed. The results of the 3D multistory structures show that the lateral forces, displacement, inertia and story accelerations of the superstructure of the seismic prone buildings are significantly reduced due to bearing insertion. The nonlinear dynamic analysis shows 12 to 40% lessening in base shear when LRB is incorporated leading to substantial allowance of horizontal displacement. It is revealed that the LRB isolators might be potential options to diminish the respective floor accelerations, inertia, displacements and base shear whatever the condition coincides. The isolators with lower force intercept but higher isolation period is found to be better for decreasing base shear, floor acceleration and inertia force leading to reduction of structural and non-structural damage. However, LRB with lower isolator period seems to be more effective in dropping displacement at bearing interface aimed at reducing horizontal shift of building structure.

The Maintenance and Management Method of Deteriorated Facilities Using 4D map Based on UAV and 3D Point Cloud (3D Point Cloud 기반 4D map 생성을 통한 노후화 시설물 유지 관리 방안)

  • Kim, Yong-Gu;Kwon, Jong-Wook
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.3
    • /
    • pp.239-246
    • /
    • 2019
  • According to the survey on the status of aged buildings in Korea, A number of concrete buildings deterioration such as houses and apartment buildings has been increased rapidly. To solve this problem, the research related to the facility management, that is one of the importance factor, for monitoring buildings has been increased. The research is divided into Survey-based and Technique-based. However, the problem is that Survey-based research is required a lot of time, money and manpower for management. Also, safety cannot be guaranteed in the case of high-rise buildings. Technique-based research has limitations to applying to the current facility maintenance system, as detailed information of deteriorated facilities is difficult to grasp and errors in accuracy are feared. Therefore, this paper contribute to improve the environment of facility management by 4D maps using UAV, camera and Pix4D mapper program to make 3D model. In addition, it is expected to suggest that residents will be offered easy verification to their buildings deterioration.

A Review of the Physical Performance of Lightweight Aerated Concrete for Use as an Interior Core Material in Fire Doors (방화문 내부 심재로 적용하기 위한 경량기포콘크리트의 물리적 성능 검토)

  • Hong, Sang-Hun;Kim, Bong-Joo;Jung, Ui-In;Kim, Hae-Nah;Park, Jun-Seo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.111-112
    • /
    • 2023
  • With the development of cities, the density of the population is continuously increasing as buildings become larger and more high-rise, but since the Haeundae residential complex fire in Busan in 2010, there has been a growing need to meet the fire protection performance of buildings as large-scale fires continue to occur every year. On the other hand, fire doors, which are one of the fire protection performance of buildings, have been judged unqualified in 82% of cases when fire doors constructed on the actual site were inspected after completion. The reason for this is that paper honeycomb and glasswool, which are used as core materials for fire doors, absorb moisture, reducing thermal insulation performance, and sagging due to increased weight, leading to performance degradation due to warping in empty spaces. To overcome these problems, research is underway to apply lightweight aerated concrete, an inorganic material, as a core material. Therefore, in order to select a blowing agent that produces stable bubbles prior to the production of lightweight bubble concrete for application as a fire door inner core, this study examined the physical performance according to the type of blowing agent and dilution concentration, and the following conclusions were drawn. Compared to vegetable bubbles and independent bubbles, synthetic bubbles have 3~8% higher thermal conductivity than independent bubbles, but 3~6% lower slurry density than vegetable bubbles, and 2~13% higher compressive strength, which is thought to be an improvement of synthetic bubbles.

  • PDF

Research on non-welding door frame assembly method that allows on-site assembly (현장조립이 가능한 무용접 도어프레임 조립방식에 대한 연구)

  • Lee, Joo-Won;Lim, Bo-Hyeok;Lee, Gwang-Woo;Lee, Hae-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.155-156
    • /
    • 2023
  • In the case of steel door frames commonly found in general buildings, there are various assembly methods such as rivets, bolts, and welding, but the welding method is generally used. However, this welding joint method has many problems, such as distortion due to heat and damage due to external shock. In particular, when used as a fire door, problems may occur in the event of a fire due to distortion caused by heat from welding and the weak welded joint area. In the case of rivet or welded joints, when moved after assembly, joint loosening due to external shock may occur. Problems may arise where the bonding strength becomes weak. In addition, with the recent increase in high-rise buildings and larger buildings, when assembly is completed and brought to the site, a place is needed to store it, and in addition, there is a problem in that it has to be transported several times in small quantities to the installation site, which is another problem of time and cost loss. This is coming to the fore. In order to fundamentally solve this problem, we have researched and developed a non-welding door frame that can be assembled on site. We have researched and developed three assembly methods: screw-type, insert-type, and protrusion-type. Non-welded door frames are small in size and easy to package, making them advantageous for domestic and overseas exports.

  • PDF

Analysis on Material Color and Use of Stone for the Lower-Parts of Apartment in Daegu (대구광역시 아파트 저층부 석재 사용 실태 분석)

  • Lee, Ye-ji;Kim, So-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.1
    • /
    • pp.132-139
    • /
    • 2018
  • The high-rise and high-density apartment complexes are built on a large scale and occupy a large portion of the city. The facade of the apartment has a great influence on the cityscape. In particular, the lower part of apartment design gives people to important impressions. For the harmonious landscape of the city, the color plan emphasizes its importance as an influential visual design element that forms the urban landscape. In specialized apartment design, especially finishing material on lower-parts of apartment which is recognized by pedestrian is more important planning factor. Also, finishing material which is one of the primary design elements is important for making the entire image about the building with color. Nowadays stone is mostly used for specialized design on lower-level in apartments. Stone makes luxurious image and harmonious landscape as a nature material. But when planning for design, only general stone graphic or pictures is used without specific plan, after construction, there is a big difference between a plan and the actual color and image. Thus based on exact understanding of stone, I analyzed current state of expression for stone which is used for lower-parts of apartments in Daegu. By this, the purpose of this study is to present detailed data to offer the basis for planning specialized design of lower-parts of apartment.

Assessment of the swelling potential of Baghmisheh marls in Tabriz, Iran

  • Asghari-Kaljahi, Ebrahim;Barzegari, Ghodrat;Jalali-Milani, Shahrokh
    • Geomechanics and Engineering
    • /
    • v.18 no.3
    • /
    • pp.267-275
    • /
    • 2019
  • Tabriz is a large Iranian city and the capital of the East Azerbaijan province. The bed rock of this city is mainly consisted of marl layers. Marl layers have some outcrops in the northern and eastern parts of city that mainly belong to the Baghmisheh formation. Based on their colors, these marls are classified into three types: yellow, green, and gray marls. The city is developing toward its eastern side wherein various civil projects are under construction including tunnels, underground excavation, and high-rise building. In this regard, the swelling behavior assessment of these marls is of critical importance. Also, in lightweight structures with foundation pressure less than swelling pressure, several problems such as walls cracking and jamming of door and windows may occur. In the present study, physical properties and swelling behavior of Baghmisheh marls are investigated. According to the X-ray diffractometer (XRD) results, the marls are mainly composed of Illite, Kaolinite, Montmorillonite, and Chloride minerals. Type and content of clay minerals and initial void ratio have a decisive role in swelling behavior of these marls. The swelling potential of these marls was investigated using one-dimensional odometer apparatus under stress level up to 10 kPa. The results showed that yellow marls have high swelling potential and expansibility compared to the other marls. In addition, green and gray marls showed intermediate and low swelling potential and swelling pressure, respectively.

Structural System Selection and Highlights of Changsha IFC T1 Tower

  • Jianlong, Zhou;Daoyuan, Lu;Liang, Huang;Jun, Ji;Jun, Zhu;Jingyu, Wang
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.2
    • /
    • pp.99-106
    • /
    • 2014
  • This paper presents the determination of the structural system of the Changsha IFC T1 tower with 452 m in architectural height and 440.45 m in structural height. Sensitivity analyses are carried out by varying the location of belt trusses and outriggers. The enhancement of seismic capacity of the outer frame by reasonably adjusting the column size is confirmed based on parametric studies. The results from construction simulation including the non-load effect of structures demonstrate that the deformation of vertical members has little effect on the load-bearing capacity of belt trusses and outriggers. The elastoplastic time-history analysis shows that the overall structure under rare earthquake load remains in an elastic state. The influence of the frame shear ratio and frame overturning moment ratio on the proposed model and equivalent mega column model is investigated. It is found that the frame overturning moment ratio is more applicable for judging the resistance of the outer frame against lateral loads. Comparison is made on the variation of these two effects between a classical frame-core tube-outrigger structure and a structure with diagonal braces between super columns under rare earthquakes. The results indicate that plasticity development of the top core cube of the braced structure may be significantly improved.

A Study on the Development of Force Limiting Devices(FLD) which Induce Yielding before Elastic Buckling (좌굴전 항복유도 장치(FLD) 개발에 관한 연구)

  • Kim, Cheol Hwan;Chae, Won Tak;Oh, Young Suk;Kim, Chae Yeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.3
    • /
    • pp.279-287
    • /
    • 2013
  • The steel members are applied to high rise building since they have high strength compare to the concrete member. On the other hand, the elastic buckling is likely to occur in steel member because of their small section. When the elastic buckling occur, the steel structure lose a load carrying capacity. The steel frame would be unstable due to a rapid decline in strength by buckling. The purpose of this study is the development of FLD(Force Limiting Device) to prevent a elastic buckling for a slender member. Further, the behavior of steel structures with FLD would be stable by high energy absorption capacity. The proposed type of FLD is the type of out-of-plane resistance. In this study, member test and FEM analysis for proposed type were performed. The test parameters are thickness and gradient angle of out-of-plane plate. The proposed type may be effective method for FLD.