• Title/Summary/Keyword: High-rise Residential Buildings

Search Result 177, Processing Time 0.031 seconds

A Study on the Improvement and Environment-friendly Interior Space Planning of High-rise Residences in Korea - focuesd on the case analysis by environment-friendly architectural certification - (국내 초고층 주거의 친환경적 실내 공간 계획 및 개선방안 연구 - 친환경 건축 인증 제도에 의한 사례 분석을 중심으로 -)

  • Kim, Ja-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.17 no.3
    • /
    • pp.23-33
    • /
    • 2008
  • After the concept of apartments was introduced in 1960s in Korea, on account of the development of architectural technology and science, high-rise residences in Korea are getting higher, and these residences have been becoming high-rise commercial/residential buildings since 1990. Nowadays, as the construction of high-rise commercial residential building complex is booming, the difference between these complex and high-rise apartments is getting smaller, and these two kind of high-rise residences are becoming new residential style in Korea. And these high-rise residences are considered the symbol of wealth owing to the marketing strategy emphasizing high quality, refined interior, a fair view, and the protection of privacy. However, high-rise residences bring about many problems related to health and psychology caused by the consumption of a large amount of energy, pollutant emission, the deterioration of the quality of indoor air, and vibration. For this reason, in this study, we tried to emphasize the necessity of environment-friendly access to provide healthy living environment and to reduce the negative effect of housing life in high-rise residences, and find the method to improve environment-friendly quality and health of residents in interior space. Therefore, this study aims to detect the problems and the items to be improved of interior spaces of high-rise residences by quantitative, qualitative analysis of the evaluation elements and the floor planning elements deduced from environment-friendly architectural certification in Korea and the other countries, and suggest the guideline to improve the environment-friendly quality of these interior spaces.

A Study on the Application of Low-Rise and High-Density Multiple Dwelling Housing Model in Urban Individual Residential Area - Focused on Ui-dong Public Detached Housing Area - (도시단독주택지 저층고밀형 집합주택 모델의 적용에 관한 연구 - 우이동 국민주택단지를 대상으로 -)

  • Jun, Byung-Kweon
    • Journal of the Korean housing association
    • /
    • v.22 no.3
    • /
    • pp.101-111
    • /
    • 2011
  • This study was conducted to investigate the indiscriminate development occuring as a result of high-density land use per lot in residential areas of Seoul, which mainly consist of detached houses. The primary goals of this study were: (1) to suggest a block unit development method as an alternative architectural method of the current uniform development, in which high-rise and high-density apartments are usually built; and (2) to check the feasibility of the suggested method. Based on the analyses of the existing block composition types of residential areas, the prerequisite planning indices for applying a collective housing model were investigated. Subsequent to applying a collective housing type within each unit block, the collective housing model was analyzed. The results of the analyses showed that indiscriminate development was rampant in detached urban houses areas, and more than 70% of the buildings constructed before the 1980s needed re-development. The feasibility of the models was investigated depending on the models of low-rise and high-density collective housing, which utilize various block arrangements such as the court type, linear type, villa type, and composite type. The results of this study showed that the newly applied low-rise and highdensity multiple dwelling housing model in urban individual residential area significantly contributed to creating a good living environment in terms of both physical and psychological aspects.

Stack Effect in High-Rise Buildings: A Review

  • Mijorski, Sergey;Cammelli, Stefano
    • International Journal of High-Rise Buildings
    • /
    • v.5 no.4
    • /
    • pp.327-338
    • /
    • 2016
  • This technical paper presents a detailed review of the stack effect phenomenon and of the associated implications pertaining to the design and construction of high-rise buildings in regions of extreme climatic conditions. The present review is focused on both the classical 'chimney' effect as well as on the reverse stack effect, which are respectively related to cold and hot climates. For the purposed of the work here presented, the ASHRAE (2013) design conditions of Astana (Kazakhstan) and Riyadh (Kingdom of Saudi Arabia) were selected. A 230 m tall residential building of rectangular floor plan was numerically modelled in the context of the climatic conditions of the two abovementioned cities and a number of sensitivity analyses were performed, covering parametric changes of: temperature, façade air tightness, site wind speeds and wind directions.

The study on the height standard and the slenderness ratio according to location types of Mixed-use Residential Tall buildings (초고층 주상복합건축물 입지유형에 따른 높이기준 및 세장비 제안에 관한 연구)

  • Sung, Lee-Yong;Kim, Yun-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.6
    • /
    • pp.2779-2788
    • /
    • 2012
  • The housing market is now difficult because of excess of the increase rate of housing and long-term recession but high-rise mixed-use buildings can mix residential facilities with various demand facilities focusing and they have the advantages to secure open space and excellent view by high-rise apartment. But there are problems by hindrance of skyline formation and height of buildings. Therefore, the purpose of this study is to suggest the height standard and the slenderness ratio to location types of Mixed-use Residential Tall buildings. For the method of the study, term arrangement through literature search and the precedent research survey were first done, the level of urban design and the details related to the height of buildings were done as the case research focusing on the 16 cases in Seoul. The following results were drawn by suggesting the height standard and the slenderness ratio by location type based on them. First, the height of mixed-use building by location type in the level of urban design gets higher starting from the secondary center of the city and can be suggested as from less than 150m to more than 200m. Second, the slenderness ratio shall be planned as more than 1:3 because the area of the ground level of mixed-use building is large unlike Mixed-use Residential Tall buildings and visual passage shall be placed so that unity of openness and group formation will be planned. Third, for the height related to Mixed-use Residential Tall buildings, amendment of the special architectural district system and the special law related to super high-rise buildings shall be enacted.

Seismic performance of RC buildings subjected to past earthquakes in Turkey

  • Inel, Mehmet;Meral, Emrah
    • Earthquakes and Structures
    • /
    • v.11 no.3
    • /
    • pp.483-503
    • /
    • 2016
  • This study aims to evaluate seismic performance of existing low and mid-rise reinforced concrete buildings by comparing their displacement capacities and displacement demands under selected ground motions experienced in Turkey as well as demand spectrum provided in 2007 Turkish Earthquake Code for design earthquake with 10% probability of exceedance in 50 years for soil class Z3. It should be noted that typical residential buildings are designed according to demand spectrum of 10% probability of exceedance in 50 years. Three RC building sets as 2-, 4- and 7-story, are selected to represent reference low-and mid-rise buildings located in the high seismicity region of Turkey. The selected buildings are typical beam-column RC frame buildings with no shear walls. The outcomes of detailed field and archive investigation including approximately 500 real residential RC buildings established building models to reflect existing building stock. Total of 72 3-D building models are constructed from the reference buildings to include the effects of some properties such as structural irregularities, concrete strength, seismic codes, structural deficiencies, transverse reinforcement detailing, and number of story on seismic performance of low and mid-rise RC buildings. Capacity curves of building sets are obtained by nonlinear static analyses conducted in two principal directions, resulting in 144 models. The inelastic dynamic characteristics are represented by "equivalent" Single-Degree-of- Freedom (ESDOF) systems using obtained capacity curves of buildings. Nonlinear time history analysis is used to estimate displacement demands of representative building models idealized with (ESDOF) systems subjected to the selected ground motion records from past earthquakes in Turkey. The results show that the significant number of pre-modern code 4- and 7-story buildings exceeds LS performance level while the modern code 4- and 7-story buildings have better performances. The findings obviously indicate the existence of destructive earthquakes especially for 4- and 7-story buildings. Significant improvements in the performance of the buildings per modern code are also obvious in the study. Almost one third of pre-modern code buildings is exceeding LS level during records in the past earthquakes. This observation also supports the building damages experienced in the past earthquake events in Turkey.

A Study on the Right of Light Impact at Adjacent Residential Area by High-rise Residential Commercial Complex Building (상업지역내 고층건물의 인접주거 지역 일조권 영향에 관한 연구)

  • Lee, Sang-Hwa;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.2
    • /
    • pp.10-18
    • /
    • 2009
  • In order to determine the violation of right of light impact at adjacent residential area by high-rise building, analysis on the right of light for high-rise residential commercial complex building block at Gahngnam-ku, Seoul, Korea was carried out using Google Sketchup Pro. After the analysis th sunshine duration of B apartment decreased from 5 hours 16 minutes 3 hours 48 minutes by I hour 42 minutes after construction. It shows that the total sunshine duration is less than the Seoul City Government Standard which is more than 4 hours a day, or more than 2 consecutive hours. Lowering the heights of apartments by 54m would increase the total sunshine duration which would meet the Seoul City Government Standard by four hours seven minutes. Problems that rna lead to the violation on the right of light in the adjacent area should be discussed in advance and minimized by analyzing the right of light among buildings and structures which are scheduled to be constructed on the site during construction penni! process when high-rise building is proposed.

Dense Downtown vs. Suburban Dispersed: A Pilot Study on Urban Sustainability

  • Wood, Antony;Du, Peng
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.2
    • /
    • pp.113-129
    • /
    • 2017
  • This paper presents the initial findings of a ground-breaking two-year CTBUH-funded research project investigating the real environmental and social sustainability of people's lifestyles in a number of high-rise residential towers in downtown Chicago, and a comparable number of low rise homes in suburban Oak Park, Chicago - based on actual energy bills and other real data. The study is ground-breaking because, to date, similar studies have been mostly based on very large data sets of generalized data regarding whole-city energy consumption, or large-scale transport patterns, which often misses important nuances. This study has thus prioritized quality of real data (based on around 250 households in both high rise and low rise case studies), over quantity. In both urban and suburban cases, the following factors have been assessed: (i) home operational energy use, (ii) embodied energy of the dwelling, (iii) home water consumption, (iv) mobility and transport movements, (v) urban/suburban Infrastructure, and (vi) quality of life. The full results of this seminal study will be published in the form of a CTBUH Research Report publication in 2017. Presented below is an overview of the initial (and, currently, unverified) findings of the research, together with the limitations of the study that should be taken into account, as well as future plans for developing this important pilot study.

The Post-Occupancy Evaluation of Outdoor Environments in Bundang Model Complex: With Super High-rise.High-rise.Low-rise Apartments in Hyundai Apartment Complex (분당시범단지 초고층.고층.저층단지의 옥외환경평가 : 현대아파트 단지를 중심으로)

  • 김유일;함지현;강석희
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.27 no.2
    • /
    • pp.130-139
    • /
    • 1999
  • The survey site, the Hyundai Apartment Complex in the Bundang Model Complex, includes three housing layout types; super high-rise, high-rise and low-rise apartment buildings. The site includes artificial ground over underground parking lots. The overall objective of this study is to evaluate social and physical factors of housing environments in each types of layout. The data has been complied from residents of apartment through questionnaire. The questionnaire include elements of neighborhood, outdoor space, parking zones, and the overall complex design in each layout types. The predictors of outdoor space satisfaction in apartment housing complex are found as follows: "abundance of trees in quantity", "the role as front yards", "harmony of buildings with landscape", "the more distance between buildings" and "maintenance quality of site". Layout of super high-rise apartment site is most satisfied. Introduction of car-free deck space is favored by resident because of safty and quiet resting area. However the low quality of green and lack of shades on the artificial land are identified as problems.on the artificial land are identified as problems.

  • PDF

A Numerical Analysis on the Outside Pressure Distribution by Outdoor Wind Effect in a High-rise Residential Building (수치해석을 이용한 초고층 주거건물에서 외풍영향에 의한 외벽 압력 분포 분석)

  • Kim, Chi-Wan;Yang, Soon-Chang;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.10
    • /
    • pp.639-645
    • /
    • 2011
  • The object of this study is to analyze and evaluate outdoor wind pressure effect in a high-rise residential building when seasonal wind blow on coast area. The target building consists of 3 tower buildings over 250m in height. For the evaluation of the outdoor wind effect, CFD simulation was performed. The results of the simulations are as follows : 1) In that case of high-rise building, horizontal stream is more affected than vertical stream. 2) In case of summer season northeasterly wind, building pressure distributions are unstable and surface pressures of outside are effected respectively. 3) In case of winter season westerly wind, building preassure differentiations are not so much because of screening effects of the B, and the C buildings. 4) In case of winter season northwesterly wind, front wind affects on the A building directly because of no obstacles.

A Study on the semantic network system of the line of flow appearing on the residential space of super high-rise apartments (초고층아파트 주거공간에 나타난 동선의 의미적 네트워크 체계에 관한 연구)

  • Yoon, Jae-Eun;Kim, Joo-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.3 s.62
    • /
    • pp.58-65
    • /
    • 2007
  • The residential space of super high-rise buildings, having a form of a huge three-dimensional vertical city, affect the residents psychologically and qualitatively according to the line of flow. Because of these affects, the system of the line of flows is a very important factor. In this study, we recognize the super high-rise apartment's line of flow as a semantic network system based on case studies. And we also understand the mutual relationship by analyzing each space to recognize what effect it does on the residential environment. Furthermore, to bring up a better semantic network system for super high-rise apartment's line of flows is our goal. According to the case studies, the semantic network of the line of flow consists of 3 parts: the functional network, economical network and unit network. The functional network is composed of the 'need' and 'has', while the economical network includes variable walls that can be changed following the user's taste and eccentric positioned living rooms that protect personal privacy. Therefore the economical network started to appear while the personal value changed according to the improvement of the social condition. Finally, the unit network is a network that effects each unit that has ambiguous boundaries due to the appropriate arrangement between transitional spaces. And the unit network is based on the functional network.