Comparison of Egress Modeling and Experiments for Joint Flow Rate in the Staircase (피난계단 합류 시 유동률에 대한 피난실험 및 모델링 비교)

  • Hwang, Eun-Kyoung;Woo, Sujin;Kim, Jong-Hoon;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.28 no.6
    • /
    • pp.41-46
    • /
    • 2014
  • Junction at the staircase is one of key factors for building egress analysis. The most important factor is the congestion at the door or somewhere connecting from bigger area to smaller one. The other factor is the congestion in the staircase. It happens when people from upper floors meets people from the connecting floor. Especially egress situation at the high-rise building is worse. The simulation of the junction is only described by physical agent algorithms in egress model. For that reason, the description of phenomena will validate with the result of experiment and estimate the gap between modeling and experiment. In this research, the experiment of the junction and the simulation was conducted and validated. The gap between the experiment and the modeling was estimated. The flow rates of modeling were lower than the modeling.

A Occupant Load Density and Computer Modelling of Evacuation time in Office Buildings (사무소 건물의 거주밀도 분포와 피난시간 예측)

  • Kim, Un-Hyeong;Rui, Hu;Kim, Hong
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.35-42
    • /
    • 1999
  • A occupant load density of contemporary office buildings were surveyed by a building w walk through procedure in Korea. The survey results of ten office buildings are range from 1 2 2 2 213.14 m !person 041.4 ft !person) to 22.69 m /person (244.34 ft !person) with 95% confidence l level and the mean occupant load density is 17.92 m2/person 092.87 ft2/야rson). The impacts of occupant load on evacuation flow time was analyzed by applying time-based egress m model, SIMULEX with various occupant load densities from previous studies. I In order to demonstrate the validation of egress modeling method, fire evacuation exercise a and computer simulation were used to simulate the actual evacuation plan for a high-rise office building. An analysis and comparison of the results of these approaches was made to i illustrate the influence of model limitations on the result of prediction The result of the study shows that the introduction of occupant load concept in building c code of Korea is essential to achieving resonable building life safety design in future.

  • PDF

Method to Select Tower Cranes Using Augmented Reality in Smart Devices (스마트 기기의 증강현실을 이용한 타워크레인 선정방안)

  • Ryu, Han-Guk;Choi, Heebok;Jang, Myung-Houn
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.407-413
    • /
    • 2014
  • Appropriate selection of lifting equipments for a high-rise building construction project is one of the important factors to the project's success. Proper position of a tower crane on a construction site is so important to be determined by an expert or an experienced construction manager who draws working range of a tower crane and moves it over 2D(dimensional) site layout plan. 3D CAD, BIM, and virtual reality are is used for building design and construction, but it is not usual to use them for temporary facility planning or selection of a tower crane. This study proposes a suitable method to use augmented reality to select proper position of tower cranes. An augmented reality prototype is implemented by Vuforia and Unity 3D on a smart device to verify the practicability of the proposed method. The prototype application installed on a smart device shows several tower cranes on different markers in a real architectural drawing to locate the proper tower crane.

Estimation of the Potential Area for Roof Greening in Gyeonggi-do and Its Implications (경기도의 옥상녹화 가용면적 추정과 이의 정책적 함의)

  • Park, Eun-Jin;Nam, MiA;Kang, Gyui
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.1
    • /
    • pp.107-117
    • /
    • 2012
  • We estimated the potential area roof greening in Gyeonggi-do that will mitigate the heat island effect. The estimation was based on building age, roof shape, and building use which were recorded in the building register from "Sewoomteo, the Building Administration System in the Ministry of Land, Transport and Maritime Affairs. The estimated potential roof greening area in Gyeonggi-do was approximately $102.5km^2$ assuming that the buildings for residence, public, education(school), office, shopping mall are appropriate for roof greening. The area occupied by apartment buildings over six-story was 76.3% of the potential roof greening area 10.2% for individual houses, 5.9% for under five-story apartment buildings, and 3.7% for school buildings. The result indicated that it is residential buildings that we need to pay attention for roof greening, especially high-rise buildings over six-story. Greening of the whole estimated area, $102.5km^2$, in Gyeonggi-do will result in the increase of green space per capita by $8.74m^2$. This is 1.65 times greater than the area of current urban parks, and 1.97 times greater than the total area of neighborhood parks, children's parks, and pocket parks. Greening of the estimated roof area will increase green coverage of urban area by twice, adding to current green coverage of the urban areas, 11.3%, in 10 major cities. In particular, the effect of roof greening would be remarkable in inceasing the green space of Anyang City, Gwangmyeong City, and Guri City where neighborhood park area falls short.

Post-fire Repair of Concrete Structural Members: A Review on Fire Conditions and Recovered Performance

  • Qiu, Jin;Jiang, Liming;Usmani, Asif
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.323-334
    • /
    • 2021
  • Concrete structures may rarely collapse in fire incidents but fire induced damage to structural members is inevitable as a result of material degradation and thermal expansion. This requires certain repairing measures to be applied to restore the performance of post-fire members. A brief review on investigation of post-fire damage of concrete material and concrete structural members is presented in this paper, followed by a review of post-fire repair research regarding various types of repairing techniques (FRP, steel plate, and concrete section enlargement) and different type of structural members including columns, beams, and slabs. Particularly, the fire scenarios adopted in these studies leading to damage are categorized as three levels according to the duration of gas-phase temperature above 600℃ (t600). The repair effectiveness in terms of recovered performance of concrete structural members compared to the initial undamaged performance has been summarized and compared regarding the repairing techniques and fire intensity levels. The complied results have shown that recovering the ultimate strength is achievable but the stiffness recovery is difficult. Moreover, the current fire loading scenarios adopted in the post-fire repair research are mostly idealized as constant heating rates or standard fire curves, which may have produced unrealistic fire damage patterns and the associated repairing techniques may be not practical. For future studies, the realistic fire impact and the system-level structural damage investigation are necessary.

A Study on Sustainable Greenspace based on Urban Remodeling Design of an Old Apartment Building

  • Myung Sik Lee;Seung Ryeol Min
    • International Journal of High-Rise Buildings
    • /
    • v.12 no.2
    • /
    • pp.179-193
    • /
    • 2023
  • It is undeniable that urban greenspace is the soul of a city. Conventional urban greenspace such as parks, community gardens, playgrounds etc. located within a city reduce the negative effects of pollution, play a major role in the survival of the urban ecosystem, and promote healthy lifestyles. Today, 55% of the world's population lives in urban areas, which is expected to increase to 68% by 2050. Projections show that urbanization and the gradual migration to urban areas combined with the fast growth of the world's population, could add another 2.5 billion people to urban areas by 2050 and almost 90% of this increase will take place in Asia(UN, 2018). As a result, many plots in the cities are and will continue to be occupied with buildings to provide residential support to the increased population. This will dangerously decrease urban greenspaces. Moreover, worldwide, food crisis, energy crisis, and social crisis is posing a great threat to the existence of mankind. Additionally, the COVID - 19 has introduced a new lifestyle where from work culture to community configuration has drastically transformed. In this scenario, residential buildings will have to serve more than just providing privacy and shelter. As urban greenspaces are being occupied by concrete residential buildings, these buildings will have to compensate for the percentage of urban green they are destroying and the issues they are imposing in the process. The goal of this thesis is to design, architecturally define and, categorize comprehensive 'sustainable Greenspace'(S.G.S) for the multi-family housing scenario. These will be different than the conventional green (veranda, rooftop green) we commonly see in residential buildings. An old, dilapidated apartment building will be the target of remodeling to fulfill the purpose of this thesis.

Quality Improvement Measures of Modular Public Rental Apartment Houses through Defects Analysis (모듈러 공공주택의 하자분석을 통한 품질 개선 방안)

  • Lee, Soon Guh;Kim, Gyu Yong;Nam, Jeongsoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.4
    • /
    • pp.425-436
    • /
    • 2024
  • Modular apartment houses are a relatively new approach to public housing in South Korea. While promising in terms of efficiency and potential cost benefits, initial occupancy and maintenance data highlight areas for improvement in quality control. Analysis of defects reported during occupancy and maintenance stages revealed a high prevalence of issues with wallpaper and flooring. This suggests a need for stricter quality control measures during the production and installation of these building components. Furthermore, maintenance data identified shortcomings in the waterproofing methods employed for roofs, as well as in the design and construction management of connections between the low-rise concrete frames and the modular units themselves, including balconies. These findings point towards the importance of meticulous design and rigorous construction management practices to ensure the long-term durability of these critical building elements. Finally, the research suggests that unifying responsibility for construction management by awarding contracts for both the frame and the modular units to a single company could improve overall quality control. This approach could potentially mitigate issues arising from divided responsibility and streamline communication channels. By addressing these quality control concerns, modular construction has the potential to become a more widely adopted and successful method for delivering public housing in South Korea.

Linking Urban Development Density with Infrastructure Capacity (GIS를 활용한 도시개발과 기반시설의 합리적 연계)

  • Yeo, Chang-Hwan;Kim, Jae-Ik
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.4
    • /
    • pp.46-59
    • /
    • 2007
  • Urban infrastructure is a core of urban growth management which concerns with location, time and costs of development. Despite an inevitable link between development density and infrastructure capacity in urban areas, little study have been performed. For this reason, development activities are undergone without any clear evidence or analysis. The main purposes of this paper are to build subject maps of urban infrastructure capacity which illustrate the level of education service and road capacity, and to give reference standard for development decision at given location. For these purposes, the case study of the high-rise multi-purpose buildings in Daegu metropolitan city is performed. The main findings are follows. First, road ratio is high in the CBD and its surrounding areas as well as rural area, and low in areas of manufacturing, parks and military use. Second, educational facility, represented by the number of student per classroom of elementary school, is fairly abundant across the city, especially in the CBD and rural areas. Third, the high-rise multi-purpose buildings have been built in population-losing infrastructure-abundant areas, in general. Based on these results, this study concludes that the high-rise multi-purpose buildings may induce population-inflow and have low possibility to bring about overly dense developments.

  • PDF

Correlation of Experimental ana Analytical Inelastic Responses of 1:12 Scale Irregular High-Rise RC Buildings (1:12축소 비정형 고층 RC 건물의 비선형거동에 대한 실험과 해석의 상관성)

  • Ko, Dong-Woo;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.95-104
    • /
    • 2007
  • Three types of high-rise RC building structures having irregularity in the lower two stories were selected as prototypes and were performed nonlinear static analysis by using OpenSees to verify the analysis technique and to investigate the seismic capacity of those buildings. The first one has a symmetrical moment resisting frame (Model 1), the second has an infilled shear wall in the central frame (Model 2), and the third has an infilled shear wall only in one of exterior frames (Model 3). Fiber model, which consists of concrete and reinforcing bar represented from stress-strain relationship, is adapted used for simulate the nonlinearity of members, and MVLEM(Multi vertical linear element model) is used for simulate the behavior of wall. The analytical results are simulate the behavior of piloti stories well, for example, the stiffness and yield farce of piloti stories, the up-lift of wall and the variation of lateral stiffness of column due to the variation of axial forces. Overstrength of Model 2 and Model 3 are about 2 times larger than that of Model 1. The reason of the high oversttrength and ductility of Model 2 and Model 3 is that the conservative design of Model 2 and Model 3, whose beam and column sections are the same as those of Model 1. The ductilities of Model 1 and Model 3 are slightly larger than that of Model 1 and Model 3. Model 1 and Model 3 reached mechanism condition, whereas Model 2 failed to the shear failure of shear wall and the large axial forces in columns due to large overturning moment.

Study of Smoke Behavior and Differential Pressure in the Refuge Safety Area According to Damper Capacity of Smoke Control (제연댐퍼 송풍량에 따른 피난 안전 구역 차압 및 연기 거동 특성 연구)

  • Lee, Jae-Bin;Moon, Joo-Hyun;Lee, Seong-Hyuk;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.103-109
    • /
    • 2011
  • In this study, we calculated the smoke movement at the fire area of the refuge floor which has the refuge safety area in case of fire in the high rise building by using a computational fluid dynamics (CFD) code of FLUENT (ver. 13.0). The buoyancy plume was applied using the temperature and flow velocity which represent 10 MW heat release rate in order to describe the fire, and the smoke movement was predicted using a species conservation equation. The pressurization system of smoke control was adopted with smoke control damper in refuge safety area, at the result, it is confirmed that the damper capacity was enough to smoke control in which the flow rate of supply was applied 25 $m^3/s$ in the case of the door at fire area opened only, and 50 $m^3/s$ in the doors at the fire area and lobby both opened case. They were satisfied in NFSC 501-A. Even though the door of fire area closed, there were smoke leakages at the gap between the door and wall. In addition, the refugee could be isolated in the fire area when the door of fire area closed during smoke control in the case of using the high damper flow rate of supply, 50 $m^3/s$. Therefore the proper damper flow rate of supply are needed in order to prevent the damage of refugee and this study proposes the suitable condition of damper capacity according to refuge scenario.