• Title/Summary/Keyword: High-resolution camera

Search Result 540, Processing Time 0.023 seconds

Efficient Image Stitching Using Fast Feature Descriptor Extraction and Matching (빠른 특징점 기술자 추출 및 정합을 이용한 효율적인 이미지 스티칭 기법)

  • Rhee, Sang-Burm
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.1
    • /
    • pp.65-70
    • /
    • 2013
  • Recently, the field of computer vision has been actively researched through digital image which can be easily generated as the development and expansion of digital camera technology. Especially, research that extracts and utilizes the feature in image has been actively carried out. The image stitching is a method that creates the high resolution image using features extract and match. Image stitching can be widely used in military and medical purposes as well as in variety fields of real life. In this paper, we have proposed efficient image stitching method using fast feature descriptor extraction and matching based on SURF algorithm. It can be accurately, and quickly found matching point by reduction of dimension of feature descriptor. The feature descriptor is generated by classifying of unnecessary minutiae in extracted features. To reduce the computational time and efficient match feature, we have reduced dimension of the descriptor and expanded orientation window. In our results, the processing time of feature matching and image stitching are faster than previous algorithms, and also that method can make natural-looking stitched image.

Analysis and Experiment on the Tape Spring Hinges for CubeSat Missions (큐브위성 임무를 위한 테이프 스프링 힌지의 비선형 거동 분석 및 실험)

  • Yoo, JeongUk;Im, Byeong-Uk;Shin, SangJoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.10
    • /
    • pp.712-719
    • /
    • 2019
  • This paper explores an implementation of finite element analysis and experiment in the design process of a tape spring hinge used for various CubeSat missions. Tape spring hinges consist of short-length hardened-steel strips with one-sided curvature, and thus the behavior is subject to large deformation with unpredicted non-linearity. Precise dimensions of a commercial tape spring are traced by the use of high-resolution digital camera, and thin-shell FEM analysis is conducted using ABAQUS program. Based on the rotation-moment analysis suggested in previous studies, parametric analysis is conducted by adjusting the contributing factors such as strip thickness and the subtended angle of the cross section. Finally the behaviors are investigated by both analytical and non-linear finite element methods, and the results are compared with the simple measurements. Further studies suggest a possible application in dynamic characteristics of hinges during CubeSat operations.

WDENet: Wavelet-based Detail Enhanced Image Denoising Network (Wavelet 기반의 영상 디테일 향상 잡음 제거 네트워크)

  • Zheng, Jun;Wee, Seungwoo;Jeong, Jechang
    • Journal of Broadcast Engineering
    • /
    • v.26 no.6
    • /
    • pp.725-737
    • /
    • 2021
  • Although the performance of cameras is gradually improving now, there are noise in the acquired digital images from the camera, which acts as an obstacle to obtaining high-resolution images. Traditionally, a filtering method has been used for denoising, and a convolutional neural network (CNN), one of the deep learning techniques, has been showing better performance than traditional methods in the field of image denoising, but the details in images could be lost during the learning process. In this paper, we present a CNN for image denoising, which improves image details by learning the details of the image based on wavelet transform. The proposed network uses two subnetworks for detail enhancement and noise extraction. The experiment was conducted through Gaussian noise and real-world noise, we confirmed that our proposed method was able to solve the detail loss problem more effectively than conventional algorithms, and we verified that both objective quality evaluation and subjective quality comparison showed excellent results.

Mixed Reality Image Generation Method for HMD-based Flight Simulator (HMD기반 비행 시뮬레이터를 위한 혼합현실 영상 생성 기법)

  • Joo Ha Hyun;Mun Hye Kang;Yong Ho Moon
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.1
    • /
    • pp.59-67
    • /
    • 2023
  • Recently, interest in flight simulators based on HMD and mixed reality is increasing. However, they have limitations in providing various interactions and a sense of presence to pilot wearing HMD. To overcome these limitations, a mixed reality image corresponding to the interaction under the actual cockpit environment must be generated in real time and provided to the pilot. For this purpose, we proposed a mixed reality image generation method, in which the cockpit area including the pilot's body could be extracted from real image obtained from the camera attached to the HMD and then composed with virtual image to generate a high-resolution mixed reality image. Simulation results showed that the proposed method could provide mixed reality images to HMD at 30 Hz frame rate with 99% image composition accuracy.

Design for Position Protection Secure Keypads based on Double-Touch using Grouping in the Fintech (핀테크 환경에서 그룹핑을 이용한 이중 터치 기반의 위치 차단이 가능한 보안 키패드 설계)

  • Mun, Hyung-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.12 no.3
    • /
    • pp.38-45
    • /
    • 2022
  • Due to the development of fintech technology, financial transactions using smart phones are being activated. The password for user authentication during financial transactions is entered through the virtual keypad displayed on the screen of the smart phone. When the password is entered, the attacker can find out the password by capturing it with a high-resolution camera or spying over the shoulder. A virtual keypad with security applied to prevent such an attack is difficult to input on a small touch-screen, and there is still a vulnerability in peeping attacks. In this paper, the entire keypad is divided into several groups and displayed on a small screen, touching the group to which the character to be input belongs, and then touching the corresponding character within the group. The proposed method selects the group to which the character to be input belongs, and displays the keypad in the group on a small screen with no more than 10 keypads, so that the size of the keypad can be enlarged more than twice compared to the existing method, and the location is randomly placed, hence location of the touch attacks can be blocked.

Absolute Dimensions And Period Changes Of The Semi-Detached Algol Type Binary XZ Canis Minoris

  • Kim, Hye-Young;Kim, Chun-Hwey;Hong, Kyeongsoo;Jeong, Min-Ji;Park, Jang-Ho;Song, Mi-Hwa;Lee, Jae Woo;Lee, Chung-Uk
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.64.1-64.1
    • /
    • 2019
  • The first high-resolution spectroscopic and new multiband photometric observations of the semi-detached Algol type binary XZ CMi were performed at the Bohyunsan Optical Astronomy Observatory (BOAO) and the Sobaeksan Optical Astronomy Observatory (SOAO), respectively. A total of 34 spectra were obtained using the 1.8 m reflector of the BOAO equipped with the Bohyunsan Optical Echelle Spectrograph to construct the radial velocity (RV) curves of the eclipsing pair. New BVRI photometric light curves were also covered by using the SOAO 61cm reflector and a CCD camera. A detailed analysis of all eclipse timings shows that the orbital period of XZ CMi has varied in an upward parabolic variation superposed on a sinusoidal oscillation with a period of 38.0 yr and a semi-amplitude of 0.0071 days. From the spectral analysis, the effective temperature and the projected rotational velocity of the primary component were determined to be Teff,1 = 7387±161 K and v1sini = 122±6 km s-1, respectively. Our simultaneous synthesis of the double-lined RV and BVRI light curves gives the reliable system parameters of XZ CMi with a mass ratio (q) of 0.314, an orbital inclination (i) of 81.9 deg and a large temperature difference (∆T) of 2481 K. The individual masses and radii of both components are M1 = 1.91±0.08M, M2 = 0.60±0.02M, R1 = 1.60±0.02R, R2 = 1.13±0.02R, respectively. Although the primary component is located inside the δ Sct and γ Dor instability strips, no evidence of pulsation in the system was detected. The possible evolutionary status of XZ CMi is discussed.

  • PDF

THE INFRARED MEDIUM-DEEP SURVEY. V. A NEW SELECTION STRATEGY FOR QUASARS AT z > 5 BASED ON MEDIUM-BAND OBSERVATIONS WITH SQUEAN

  • JEON, YISEUL;IM, MYUNGSHIN;PAK, SOOJONG;HYUN, MINHEE;KIM, SANGHYUK;KIM, YONGJUNG;LEE, HYE-IN;PARK, WOOJIN
    • Journal of The Korean Astronomical Society
    • /
    • v.49 no.1
    • /
    • pp.25-35
    • /
    • 2016
  • Multiple color selection techniques are successful in identifying quasars from wide-field broadband imaging survey data. Among the quasars that have been discovered so far, however, there is a redshift gap at 5 ≲ z ≲ 5.7 due to the limitations of filter sets in previous studies. In this work, we present a new selection technique of high redshift quasars using a sequence of medium-band filters: nine filters with central wavelengths from 625 to 1025 nm and bandwidths of 50 nm. Photometry with these medium-bands traces the spectral energy distribution (SED) of a source, similar to spectroscopy with resolution R ~ 15. By conducting medium-band observations of high redshift quasars at 4.7 ≤ z ≤ 6.0 and brown dwarfs (the main contaminants in high redshift quasar selection) using the SED camera for QUasars in EArly uNiverse (SQUEAN) on the 2.1-m telescope at the McDonald Observatory, we show that these medium-band filters are superior to multi-color broad-band color section in separating high redshift quasars from brown dwarfs. In addition, we show that redshifts of high redshift quasars can be determined to an accuracy of Δz/(1 + z) = 0.002 - 0.026. The selection technique can be extended to z ~ 7, suggesting that the medium-band observation can be powerful in identifying quasars even at the re-ionization epoch.

Utility of Wide Beam Reconstruction in Whole Body Bone Scan (전신 뼈 검사에서 Wide Beam Reconstruction 기법의 유용성)

  • Kim, Jung-Yul;Kang, Chung-Koo;Park, Min-Soo;Park, Hoon-Hee;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.83-89
    • /
    • 2010
  • Purpose: The Wide Beam Reconstruction (WBR) algorithms that UltraSPECT, Ltd. (U.S) has provides solutions which improved image resolution by eliminating the effect of the line spread function by collimator and suppression of the noise. It controls the resolution and noise level automatically and yields unsurpassed image quality. The aim of this study is WBR of whole body bone scan in usefulness of clinical application. Materials and Methods: The standard line source and single photon emission computed tomography (SPECT) reconstructed spatial resolution measurements were performed on an INFINA (GE, Milwaukee, WI) gamma camera, equipped with low energy high resolution (LEHR) collimators. The total counts of line source measurements with 200 kcps and 300 kcps. The SPECT phantoms analyzed spatial resolution by the changing matrix size. Also a clinical evaluation study was performed with forty three patients, referred for bone scans. First group altered scan speed with 20 and 30 cm/min and dosage of 740 MBq (20 mCi) of $^{99m}Tc$-HDP administered but second group altered dosage of $^{99m}Tc$-HDP with 740 and 1,110 MBq (20 mCi and 30 mCi) in same scan speed. The acquired data was reconstructed using the typical clinical protocol in use and the WBR protocol. The patient's information was removed and a blind reading was done on each reconstruction method. For each reading, a questionnaire was completed in which the reader was asked to evaluate, on a scale of 1-5 point. Results: The result of planar WBR data improved resolution more than 10%. The Full-Width at Half-Maximum (FWHM) of WBR data improved about 16% (Standard: 8.45, WBR: 7.09). SPECT WBR data improved resolution more than about 50% and evaluate FWHM of WBR data (Standard: 3.52, WBR: 1.65). A clinical evaluation study, there was no statistically significant difference between the two method, which includes improvement of the bone to soft tissue ratio and the image resolution (first group p=0.07, second group p=0.458). Conclusion: The WBR method allows to shorten the acquisition time of bone scans while simultaneously providing improved image quality and to reduce the dosage of radiopharmaceuticals reducing radiation dose. Therefore, the WBR method can be applied to a wide range of clinical applications to provide clinical values as well as image quality.

  • PDF

Location Accuracy of Unmanned Aerial Photogrammetry Results According to Change of Number of Ground Control Points (지상기준점 개수 변화에 따른 무인항공 사진측량 성과물의 위치 정확도 분석)

  • YUN, Bu-Yeol;SUNG, Sang-Min
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.21 no.2
    • /
    • pp.24-33
    • /
    • 2018
  • DSM and orthoimage, which are representative results of UAV photogrammetry, are high-quality spatial information data and are widely used in various fields of spatial information industry in recent years. However, the UAV photogrammetry has a problem that the quality of the output of the UAV deteriorates due to the altitude of the UAV, the camera calibration, the weather conditions at the time of shooting, the performance of the GPS / IMU and the number of the ground reference points. The purpose of this study is to analyze the location accuracy of unmanned aerial photogrammetry according to the change of the number if ground control points. Experiments were made with fixed wing, and the shooting altitude was set at 130m and 260m. The number of ground reference points used was 9, 8, 5, and 4, respectively. Ten checkpoints were used. XY RMSE for orthoimage and Z RMSE for DSM were compared and analyzed. In addition, the resolution of the orthoimage was determined to affect the judgment of the operator in the verification of the planimetric position accuracy, and the visual resolution was analyzed using the Siemens star target. As a result of the analysis, the variation of the vertical position accuracy is larger than the variation of the planimetric position accuracy when the number of the ground reference points are different. Also The higher the flying height, the greater the effect of change of ground control points on position accuracy.

Extraction of Sea Surface Temperature in Coastal Area Using Ground-Based Thermal Infrared Sensor On-Boarded to Aircraft (지상용 열적외선 센서의 항공기 탑재를 통한 연안 해수표층온도 추출)

  • Kang, Ki-Mook;Kim, Duk-Jin;Kim, Seung Hee;Cho, Yang-Ki;Lee, Sang-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.6
    • /
    • pp.797-807
    • /
    • 2014
  • The Sea Surface Temperature (SST) is one of the most important oceanic environmental factors in determining the change of marine environments and ecological activities. Satellite thermal infrared images can be effective for understanding the global trend of sea surface temperature due to large scale. However, their low spatial resolution caused some limitations in some areas where complicated and refined coastal shapes due to many islands are present as in the Korean Peninsula. The coastal ocean is also very important because human activities interact with the environmental change of coastal area and most aqua farming is distributed in the coastal ocean. Thus, low-cost airborne thermal infrared remote sensing with high resolution capability is considered for verifying its possibility to extract SST and to monitor the changes of coastal environment. In this study, an airborne thermal infrared system was implemented using a low-cost and ground-based thermal infrared camera (FLIR), and more than 8 airborne acquisitions were carried out in the western coast of the Korean Peninsula during the periods between May 23, 2012 and December 7, 2013. The acquired thermal infrared images were radiometrically calibrated using an atmospheric radiative transfer model with a support from a temperature-humidity sensor, and geometrically calibrated using GPS and IMU sensors. In particular, the airborne sea surface temperature acquired in June 25, 2013 was compared and verified with satellite SST as well as ship-borne thermal infrared and in-situ SST data. As a result, the airborne thermal infrared sensor extracted SST with an accuracy of $1^{\circ}C$.