A new ultrasonic power generator using instantaneous current resultant control-based inverter and its control system

  • Kim, Dong-Hee;Kim, Young-Seok;Yoo, Dong-Wook;Kim, Yo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1987년도 한국자동제어학술회의논문집; 한국과학기술대학, 충남; 16-17 Oct. 1987
    • /
    • pp.631-636
    • /
    • 1987
  • The design of ultrasonic transducer energy processing systems requires highly reliable command featuring mechanical frequency tracking and constant velocity control of the ultrasonic transducer with an acoustic load. This paper presents a new conceptional instantaneous current resultant control base high-frequency inverter using self turn-off devices driving an electrostrictive ultrasonic transducer system and its optimum control technique, which is implemented by feed-back of the ultrasonic transducer applied voltage and instantaneous velocity of the transducer vibrating system through a Phase-Locked-Loop control scheme. The feedback voltage corresponding to instantaneous velocity is averaged over a half-period with respect to constant amplitude/constant velocity control strategy. Described are the theory of this signal detection technique and the experimental set-up.

  • PDF

주파수 출력 제어 최적화를 통한 고강도 집속 초음파 피부치료 시스템 개발 연구 (A Study on the Development of High-Intensity Focused Ultrasound Skin Treatment System Through Frequency Output Control Optimization)

  • 박종철;김민성
    • 한국멀티미디어학회논문지
    • /
    • 제25권8호
    • /
    • pp.1022-1037
    • /
    • 2022
  • It is important to develop a transducer that generates uniform output power through frequency control of the HIFU at 4 MHz frequency for the high intensity focused ultrasound (HIFU) skin diseases treatment. In this paper, a 4 MHz frequency band HIFU system for skin disease treatment was designed, manufactured and developed. In HIFU, even for the ultrasonic vibrator in the 4 MHz frequency band, the characteristics of the output power of the HIFU are different depending on the difference in the thickness of the PZT material. Through the development of a system amplifier, the sound output of the HIFU transducer was improved to more than 48 W and uniform output power control was possible. And, it is possible to control the output power even in a frequency band of 4.0 to 4.7 MHz, which is wider than 4.0 MHz, and shows the resonance frequency of the transducer. The maximum output power for each frequency was 49.969 W and the minimum value was 48.018 W. The maximum output power compared to the minimum output power is 49.969 W, which is uniform within 4.1%. It was confirmed that the output power of the HIFU through the amplifier can be uniformly controlled in the 4 MHz frequency band.

절연층을 고려한 수중음향 트랜스듀서의 특성변화 고찰 (Characteristic Variation of Underwater Acoustic Transducer with Electric Decoupler)

  • 서희선;김정석;이정민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.244-246
    • /
    • 2005
  • The Tonpiltz transducer is one of the essential elements in sonar application. The characteristics of transducer depend on the piezoelectric ceramics and mechanical elements such as head mass, tail mass, pre-stress rod and so on. One of the important characteristics is stable electric resistance for high power transmitting operation. This paper presents characteristics variation of the underwater acoustic transducer with material variation of electric decoupler.

  • PDF

Method for Adjusting Single Matching Network for High-Power Transfer Efficiency of Wireless Power Transfer System

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyungsoo
    • ETRI Journal
    • /
    • 제38권5호
    • /
    • pp.962-971
    • /
    • 2016
  • A wireless power transfer (WPT) system is generally designed with the optimum source and load impedance in order to achieve the maximum power transfer efficiency (PTE) at a specific coupling coefficient. Empirically or intuitively, however, it is well known that a high PTE can be attained by adjusting either the source or load impedance. In this paper, we estimate the maximum achievable PTE of WPT systems with the given load impedance, and propose the condition of source impedance for the maximum PTE. This condition can be reciprocally applied to the load impedance of a WPT system with the given source impedance. First, we review the transducer power gain of a two-port network as the PTE of the WPT system. Next, we derive two candidate conditions, the critical coupling and the optimum conditions, from the transducer power gain. Finally, we compare the two conditions carefully, and the results therefore indicate that the optimum condition is more suitable for a highly efficient WPT system with a given load impedance.

고지향 수중 통신을 위한 파라메트릭 어레이 트랜스듀서의 설계 및 개발 연구 (Design and Development Research of a Parametric Array Transducer for High Directional Underwater Communication)

  • 황용환;제엽;문원규
    • 한국음향학회지
    • /
    • 제34권2호
    • /
    • pp.117-129
    • /
    • 2015
  • 파라메트릭 어레이(parametric array)는 매질의 비선형성을 이용하여 고지향성 저주파를 발생시키는 현상이다. 발생된 저주파는 직접 발생된 1차 음파에 비해 음압이 상대적으로 매우 작다. 따라서 강력한 1차 음파를 지향성 있게 발생시킬 수 있는 트랜스듀서가 필수적으로 요구된다. 본 논문에서는 파라메트릭 어레이를 위한 음원으로써 다공진 트랜스듀서의 설계, 제작, 시험평가에 대해 연구하였다. 유닛 트랜스듀서 및 배열 트랜스듀서의 설계를 해석 모델에 근거하여 수행하였으며, 이 과정을 반복하여 최적의 트랜스듀서를 제작하였다. 제작된 배열 트랜스듀서는 6.3 m 거리에서 각각 189 dB, 190 dB의 1차 음파를 확인하였으며, 파라메트릭 어레이 현상을 이용하여 136 dB의 차주파수음 발생을 확인하였다. 차주파수음은 $12{\times}18{\times}10m$크기의 수조에서 15 kHz, $8^{\circ}$ half power beamwidth의 고지향성 저주파 특성을 가지고 있음을 확인하였다.

ABCD 전송 파라메터를 사용한 광대역 음향 발신기의 역률 개선 연구 (Power Factor Compensation for Wideband Acoustic Projector Using Measurement Data and ABCD matrix)

  • 임준석;편용국
    • 전자공학회논문지 IE
    • /
    • 제48권3호
    • /
    • pp.10-15
    • /
    • 2011
  • 파워를 이용하는 음향 변환자를 설계할 경우 전기적 신호의 에너지가 가급적 많이 음향 에너지로 바뀌어서 전달되도록 하여야 한다. 이를 위해서는 방사임피던스를 포함한 초음파 변환자의 임피던스와 파워 앰프의 출력 임피던스 간에 정합이 필요하다. 특히 구동부의 출력 임피던스 값이 매우 작은 경우 센서의 역률 개선이 꼭 필요하다. 본 논문에서는 광대역 수중 음향 발신기의 역률 개선을 위해서 ABCD 전송 행렬을 사용한 정합 기법을 제안한다.

치과 임플란트 수술용 고출력 초음파 수술기 설계 및 제작 (Design and Fabrication of a High Power Piezoelectric Ultrasonic Surgery Unit for Dental Implantation)

  • 김나리;전대우;김진호;김선욱;황종희;이정배;최성재;임대진;이영진
    • 한국전기전자재료학회논문지
    • /
    • 제30권10호
    • /
    • pp.656-664
    • /
    • 2017
  • This paper presents the design and fabrication of a high power piezoelectric ultrasonic surgery unit for multi-purpose dental implantation. A conventional piezoelectric ultrasonic surgery units consists of a transducer and a tip. However, the drawback of this simple structure is that the output performance of the transducer considerably changes with the change of the tips. An ultrasonic surgery unit that has an additional booster between the transducer and the tip can solve this problem to some extent; for this, an optimal structural design for the transducer is required. We used the Bolted Langevin Transducer (BLT) as the basic transducer; it consists of piezoelectric ceramics and a metal body. It's structure was optimized using mathematical methods to determine the length and radius of the tail and head masses. Additionally, the booster was also subjected to the same methods. Using these mathematical methods, optimal results in terms of the resonance frequency (24.96 kHz), displacement ($14.27{\mu}m$), and pressure (2.8 MPa), could be obtained. The validity of this proposed surgery unit was confirmed experimentally, exhibiting a cutting force of around 7% higher than that of a conventional surgery unit.

어군탐지기용 저주파.고출력 음향 변환기의 설계 (Design of a low frequency, high power acoustic transducer to use in the echo sounder)

  • 이대재
    • 수산해양기술연구
    • /
    • 제36권1호
    • /
    • pp.1-11
    • /
    • 2000
  • A low frequency, high power hydroacoustic transducer with 7 tonpilz piston elements assembled in a circular array suitable for marine application, such as the transmission of underwater information and the development of new fisheries resources in the deep sea zone was designed. A modified Mason's model was applied to monitor and to simulate the transducer behavior at each step during the fabrication. The in air, and in water constructed tonpilz transducer was tested experimentally and numerically by changing the size and the type of the material for head, tail and acoustic window. Also, the developed transducer was excited by pulse signals and the received waveform was analyzed. The resonance peaks in the transmitting voltage response(TVR) of a single tonpilz element without housing were observed at 11.33kHz in air and 10.93kHz in air and 10.93 kHz in water, respectively, with the overall electrical-acoustic efficiency of 43.7%. The value of TVR of single tonpilz element with aluminum housing in water was 129.87dB re 1 $\mu$Pa/V at 12.25 kHz with the frequency bandwith of 2.15 kHz and half beam angle of 30.2$^{\circ}$at -3dB.The resonance peaks in the transmitting voltage response of the 7 element circular transducer were observed at 11.50 kHz in air and 11.45 kHz in water, respectively. The value of TVR in water 144.84 dB re 1$\mu$Pa/V at 11.5kHz with the frequency bandwith of 4.25 kHz and the half beam angle of $22.3^{\circ} $ at -3dB.Reasonable agreement between the experimental measurements and the theoretical predictions for the directivity patterns, TVRs and the impedance characteristics of the designed transducer was achieved.

  • PDF

Intracavitary Ultrasound Hyperthermia Applicators for Gynecological Cancer

  • Lee, Rena J. .;Suh, Hyun-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.53-53
    • /
    • 2003
  • For evaluating the feasibility of treating recurrent lesions in the vaginal cuff and cervix by hyperthermia, ultrasound applicators were designed, constructed, and characterized. For the treatment A half-cylindrical transducer Cd=1cm, length=lcm) and cylindrical transducer (d=2.5cm, length= 1.5cm) were used to construct ovoid type and cylindrical applicators. For the ovoid type applicator, each element was operated at 1.5MHz and characterized by measuring transducer efficiency and acoustic power distribution. Thermocouple probes were used to measure the temperature rise in phantom. The element sizes used in this study were selected to be comparable for high dose rate brachytherapy colpostat applicator. Each element was powered separately to achieve a desired temperature pattern in a target. The acoustic output power as a function of applied electric power of the element 1 and 2 was linear over this 1 to 40 W range and efficiencies were 32.2${\pm}$3.4% and 46.2${\pm}$0.8%, respectively. The temperature measurements in phantom showed that 6$^{\circ}C$ temperature rise was achieved at 2 cm from the applicator surface. As a conclusion, the ability of the ultrasound colpostat applicator to be used for hyperthermia was demonstrated by measuring acoustic output power, ultrasound field distribution, and temperature rise in phantom. Based on the characteristics of this applicator, it has the potential to be useful for inducing hyperthermnia to the vaginal cuff in clinic.

  • PDF

릴럭턴스를 이용한 Reluctive Pressure Transducer의 설계 (The Design using the reluctance of Reluctive Pressure Transducer)

  • 조항신;박희성;주형준;성세진;이기홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.328-331
    • /
    • 1998
  • Because of the powerful tolerance of overload, dynamic response and anti-erosion, Reluctive Pressure Transducer(RPT), as a measuring element of oil pressure equipment is applied to the measuring system of vessels, air craft. The Electrical reluctance appeared in the pressed diaphragm. To process the reluctance as a electric signal, bridge circuit is used. The design using the reluctance of pressure sensor is described in this paper. For the high efficiency of the sensitive RPT, pressure sensor structure is presented and electrical signal processing is simulated.

  • PDF