• Title/Summary/Keyword: High-isolation

Search Result 1,952, Processing Time 0.03 seconds

Development of Active Vibration Isolation Equipments Using Fuzzy Method

  • Rim, Kyung-Hwa;Yang, Xun;An, Chae-Hun;Jin, Kyoung-Bog
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.4
    • /
    • pp.17-22
    • /
    • 2007
  • Vibration isolation equipments are mostly required in precise measurement and manufacturing system. Among all the vibration isolation equipments, air-spring is the most widely used equipment because of low resonant frequency and high damping ratio. In this study, we used Takagi-Sugeno fuzzy method to design an active vibration isolation system using air-spring, and compared the fuzzy method with passive control method and PID control method. Due to the non-linearity characteristics of air-spring, fuzzy controller was verified to be the most effective both in simulation and experiment.

  • PDF

Dual-Polarized Small Base Station Antenna Integrated RF Module Applicable to Various Cell Environments for Next-Generation Mobile Communication Service

  • Lee, Jung-Nam;Lee, Yuro;Park, Bong-Hyuk;Kim, Tae-Joong
    • ETRI Journal
    • /
    • v.39 no.3
    • /
    • pp.383-389
    • /
    • 2017
  • A small dual-polarized base station antenna with a simple isolation patch is presented. A high isolation is achieved when using a shorted metallic isolation patch. The experimental results indicate that the measured impedance bandwidth of the proposed antenna is 1.72 GHz to 1.89 GHz for small cell systems and that the isolation is more than 30 dB. The proposed antenna exhibits good radiation patterns with a peak gain of 8 dBi.

Experimental Evaluation of the Performance of the HSLDS Magnetic Vibration Isolator with Consideration of the Design Parameter (설계 파라미터를 고려한 HSLDS 마그네틱 진동절연체의 실험적 성능평가)

  • Shin, Ki-Hong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.352-356
    • /
    • 2011
  • The isolation performance of a linear vibration isolator is limited to the ratio of stiffness to mass it supports. The stiffness of the isolator must be large enough to hold the weight. This results in the deterioration of the isolation performance. Recently, to overcome this fundamental limitation, the HSLDS(high-static-low-dynamic-stiffness) magnetic vibration isolator was introduced and its isolation characteristic was investigated theoretically. In this paper, the isolation performance of the HSLDS magnetic isolator is examined experimentally. Considerable amount of experiments are performed by carefully considering nonlinear characteristics. The experimental results verify the practical usability promisingly and agree with the theoretical studies, i.e. its performance is largely dependent on the key design parameter.

Polarization Diversity Antenna for Receiving Traffic Information Contents in WiBro System (교통정보 컨텐츠 수신을 위한 WiBro용 편파 다이버시티 안테나)

  • Jung, Byung-Woon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.2
    • /
    • pp.56-61
    • /
    • 2008
  • Diversity antenna system against multi-fading environment is strongly required for WiBro service of vehicle. In general, high isolation performance between antennas leads to good diversity gain. In this paper, a polarization diversity antenna is presented, which has orthogonal polarizations and good isolation characteristic. In addition, by simulation and measurement, it is certified that HWLLA (Half Wave Length Loaded Antenna) improves polarization purity on common ground. In isolation between two antennas, HWLLA can provide better isolation over 12dB than conventional PIFA (Planar Inverted F Antenna).

  • PDF

Vibration Isolation System of a Large Reverberation Chamber (대형 잔향실의 방진 설계 및 검증)

  • 김영기;김홍배;이동우;우성현;문상무
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.1026-1031
    • /
    • 2003
  • A vibration isolation system fur a large reverberation chamber (1,228㎥, 1,000ton) has been installed. The reverberation chamber generates loud noise and induces high level of vibration to perform spacecraft acoustic environmental tests. The isolation system prevents vibration transfer from the chamber to enclosure buildings. This paper describes logical design process and commissioning experiments of the system. Design criteria have been induced from rigid body model of the chamber. Finite element model has been employed to select the characteristics of rubber pads. A total of 21 rubber pads have been installed between the chamber and supporting pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. Absolute transmissibility has been measured while generating 145㏈ in the chamber. The natural frequency of the chamber is 10.5㎐, which is 80% of estimated value. Overall transmissibility at working frequency range (25㎐-10,000㎐) is less than -6㏈.

  • PDF

Studies on Protoplast Isolation and Regeneration of Lyophyllum ulmarium (느티만가닥 버섯의 원형질체 분리와 재생에 관한 연구)

  • 최혜진;김병각;현진원
    • Journal of Life Science
    • /
    • v.13 no.2
    • /
    • pp.143-149
    • /
    • 2003
  • This experiment was undertaken to investigate proper conditions for protoplast isolation and regeneration from the mycelia of Lyophyllum ulmnrium. Protoplast isolation and regeneration are influenced by a variety of factors such as enzyme, osmotic stabilizer, reaction time and age of mycelia. A combination of Novozyme 234 (10mg/ml) and cellulase Onozuka R-10 (10 mg/ml) with 0.6 M $MgSO_4$ was most effective for isolation of the protoplasts. The optimum reaction time of the mycelia with the lytic enzymes was 3.5~4 hours at $28^{\circ}C$ in shaking condition at 120 strokes per min. High yield of the protoplasts were obtained from its 4~5 days old mycelia on complete agar media. Its protoplasts were regenerated to normal hyphae. Regeneration media with 0.6 M sucrose were proper for regeneration of the protoplasts. Their regeneration frequency on complete agar media was 2.3~2.7%.

Design and Verification of a Large Reverberation Chamber's Isolation System (대형 잔향실의 방진 구조 설계 및 검증시험)

  • 김홍배;이득웅
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.11
    • /
    • pp.1066-1074
    • /
    • 2004
  • A vibration isolation system for a large reverberation chamber (1,228 $m^3$ and 1,000 ton) has been installed and verified. The reverberation chamber generates loud noise and induces high level of vibration while performing spacecraft acoustic reliability tests. The isolation system prevents vibration transfer from the chamber to the enclosure buildings. This paper describes design process and commissioning experiments of the system. Design criteria have been derived from rigid body model of the chamber. The stiffness of neoprene pads has been selected by employing finite element analysis of the reverberant chamber and isolation system. A total of 21 neoprene pads have been installed between the chamber and supporting Pedestals. A sand bag of 800kg was dropped on the chamber floor to measure the natural frequency of the isolation system. While 136.9 dB noise is generated in the chamber, absolute transmissibility of the isolation system has been measured. The measured natural frequency of the chamber is 10.2Hz, which is 80% of the predicted value. Overall transmissibility at working frequency range (25∼10.000 Hz) is less than -12.4 dB.

Verification of Launch Vibration and Shock Isolation Performance for Spaceborne Compressor Vibration Isolator with SMA Mesh Washer (형상기억합금 메쉬 와셔를 이용한 우주용 냉각기 진동절연기의 발사 진동 및 충격 저감 성능검증)

  • Lee, Myeong-Jae;Han, Je-Heon;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.7
    • /
    • pp.517-524
    • /
    • 2014
  • Micro-vibration induced by on-board equipments such as fly-wheel and cryogenic cooler with mechanical moving parts affects the image quality of high-resolution observation satellite. Micro-vibration isolation system has been widely used for enhancing the pointing performance of observation satellites. In general, the micro-vibration isolation system requires a launch locking mechanism additionally to guarantee the structural safety of mission payloads supported by the isolation system with low stiffness under launch environment. In this study, we propose a passive launch and on-orbit vibration isolation system using shape memory alloy mesh washers for the micro-vibration isolation of spaceborne compressor, which does not require the additional launch locking mechanism. The basic characteristics of the isolator were measured in static and free vibration tests of the isolator, and a simple equivalent model of the isolator was proposed. The effectiveness of the isolator design in a launch environment was demonstrated through sine vibration, random vibration and shock tests.

Seismic response characteristics of base-isolated AP1000 nuclear shield building subjected to beyond-design basis earthquake shaking

  • Wang, Dayang;Zhuang, Chuli;Zhang, Yongshan
    • Nuclear Engineering and Technology
    • /
    • v.50 no.1
    • /
    • pp.170-181
    • /
    • 2018
  • Because of the design and construction requirements, the nuclear structures need to maintain the structural integrity under both design state and extreme earthquake shaking. The base-isolation technology can significantly reduce the damages of structures under extreme earthquake events, and effectively protect the safeties of structures and internal equipment. This study proposes a base-isolation design for the AP1000 nuclear shield building on considering the performance requirements of the seismic isolation systems and devices of shield building. The seismic responses of isolated and nonisolated shield buildings subjected to design basis earthquake (DBE) shaking and beyond-design basis earthquake (BDBE) shaking are analyzed, and three different strategies for controlling the displacements subjected to BDBE shaking are performed. By comparing with nonisolated shield buildings, the floor acceleration spectra of isolated shield buildings, relative displacement, and base shear force are significantly reduced in high-frequency region. The results demonstrate that the base-isolation technology is an effective approach to maintain the structural integrity which subjected to both DBE and BDBE shaking. A displacement control design for isolation layers subjected to BDBE shaking, which adopts fluid dampers for controlling the horizontal displacement of isolation layer is developed. The effectiveness of this simple method is verified through numerical analysis.

Image Reversal Photoresist for the Single Isolation Structure of OLEDs (오엘이디의 단열 소자분리 구조를 위한 이미지 라버셜 감광제)

  • Lee, Seung-Jun;Sin, Yun-Su;Chae, Gyeol-Yeo;Im, Dae-U;Choe, Gyeong-Hui
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.541-542
    • /
    • 2009
  • We have developed an image reversal photoresist with high thermal stability and electric insulating properties for the single isolation structure of OLEDs. The thermal stability and electric insulating properties are investigated and compared with those of conventional insulator and cathode separator materials. The single isolation structure using the image reversal photoresist reduces the fabrication process steps and cuts down the manufacturing cost.

  • PDF