1 |
M. Domaneschi, L. Martinelli, F. Perotti, The Effect of Rocking Excitation on the Dynamic Behaviour of a Nuclear Power Plant Reactor Building with Base Isolation, in: Proceedings of 15th World Conference on Earthquake Engineering, Lisbon, Portugal, 2012.
|
2 |
F.F. Tajirian, J.M. Kelly, I.D. Aiken, Seismic isolation for advanced nuclear power stations, Earthq. Spectra 6 (1990) 371-401.
DOI
|
3 |
I.G. Buckle, New Zealand seismic base isolation concepts and their application to nuclear engineering, Nucl. Eng. Des. 84 (1985) 313-326.
DOI
|
4 |
N. Sato, M. Kuno, R. Shimanoto, Y. Takenaka, T. Nakayama, A. Kondo, S. Furukawa, Heat-mechanics interaction behavior of lead rubber bearings for seismic base isolation under large and cyclic lateral deformation. Part 2: seismic response analysis of base isolated reactor building subjected to horizontal bi-directional earthquake motions, in: Proceedings of 20th International Conference on Structural Mechanics in Reactor Technology, Espoo, Finland, 2009.
|
5 |
T. Fujita, Seismic isolation rubber bearings for nuclear facilities, Nucl. Eng. Des. 127 (1991) 379-391.
DOI
|
6 |
C. Zhao, J. Chen, Q. Xu, Dynamic analysis of AP1000 shield building for various elevations and shapes of air intakes considering FSI effects subjected to seismic loading, Prog. Nucl. Energy 74 (3) (2014) 44-52.
DOI
|
7 |
C. Zhao, J. Chen, Q. Xu, X. Yang, Sensitive analysis of water levels and air intakes on natural frequency of AP1000 nuclear island building considering FSI effects, Ann. Nucl. Energy 78 (2015) 1-9.
|
8 |
D. Lu, Y. Liu, X. Zeng, Experimental and numerical study of dynamic response of elevated water tank of ap1000 PCCWST considering FSI effect, Ann. Nucl. Energy 81 (2015) 73-83.
DOI
|
9 |
C. Zhao, J. Chen, J. Wang, N. Yu, Q. Xu, Seismic mitigation performance and optimization design of NPP water tank with internal ring baffles under earthquake loads, Nucl. Eng. Des. 318 (2017) 182-201.
DOI
|
10 |
D. Lu, Y. Liu, X. Zeng, AP1000 shield building dynamic response for different water levels of PCCWST subjected to seismic loading considering FSI, Sci. and Technol. of Nucl. Installations 2015 (2015) 1-8.
|
11 |
L.R. Frano, G. Forasassi, Conceptual evaluation of fluid-structure interaction effects coupled to a seismic event in an innovative liquid metal nuclear reactor, Nucl. Eng. Des. 239 (2009) 2333-2342.
DOI
|
12 |
R.L. Frano, Evaluation of the fluid-structure interaction effects in a lead-cooled fast reactor, Nucl. Technol. 33 (1) (2015) 491-499.
|
13 |
I. Micheli, S. Cardini, A. Colaiuda, P. Turroni, Investigation upon the dynamic structural response of a nuclear plant on aseismic isolating devices, Nucl. Eng. Des. 228 (2004) 319-343.
DOI
|
14 |
L.R. Frano, G. Forasassi, Preliminary evaluation of seismic isolation effects in a Generation IV reactor, Energy 36 (4) (2011) 2278-2284.
DOI
|
15 |
A. Martelli, P. Clemente, A. De Stefano, M. Forni, A. Salvatori, Recent development and application of seismic isolation and energy dissipation and conditions for their correct use, in: A. ANSAL (Ed.), Perspectives on European Earthquake Engineering and Seismology, vol. 1, Springer International Publishing, Cham, 2014.
|
16 |
F. Naeim, J.M. Kelly, Design of Seismic Isolated Structures: from Theory to Practice, John Wiley & Sons, New York, 1999.
|
17 |
U.S. Nuclear Regulatory Commission (USNRC), Regulatory Guide 1.60 Revision 2. Design Response Spectra for Seismic Design of Nuclear Power Plants, Washington, DC, 2014.
|
18 |
S.R. Malushte, A.S. Whittaker, Survey of past base isolation applications in nuclear power plants and challenges to industry/regulatory acceptance, in: Proceedings of the 18th International Conference on Structural Mechanics in Reactor Technology (SMiRT 18), Beijing, China, 2005.
|
19 |
M. Forni, A. Poggianti, F. Bianchi, G. Forasassi, R.L. Frano, G. Pugliese, F. Perotti, L.C. Dellacqua, M. Domaneschi, M.D. Carelli, Seismic isolation of the IRIS nuclear plant, Am. Soc. Mech. Eng. Pres. Ves. Pip. Div. 8 (2010) 289-296.
|
20 |
J. Chen, C. Zhao, Q. Xu, C. Yuan, Seismic analysis and evaluation of the base isolation system in AP1000 NI under SSE loading, Nucl. Eng. Des. 278 (2014) 117-133.
DOI
|
21 |
L.R. Frano, G. Forasassi, Preliminary evaluation of structural response of ELSY reactor in the after shutdown condition, Nucl. Eng. Des. 246 (4) (2012) 298-305.
DOI
|
22 |
I. Tamura, M. Kuramasu, F. Barutzki, D. Fischer, Victor Kostarev, A. Berkovskiy, P. Vasiliev, T. Inoue, S. Okita, Y. Namita, Dynamic Analysis of NPP Piping Systems and Components with Viscoelastic Dampers Subjected to Severe Earthquake Motions. American Society of Mechanical Engineers, Pressure Vessels and Piping Conference, vol. 8, Seismic Engineering, Vancouver, British Columbia, Canada, 2016.
|
23 |
F. Perotti, M. Domaneschi, S.D. Grandis, The numerical computation of seismic fragility of base-isolated nuclear power plants buildings, Nucl. Eng. Des. 262 (2013) 189-200.
DOI
|
24 |
C. Medel-Vera, T. Ji, Seismic protection technology for nuclear power plants: a systematic review, J. Nucl. Sci. Technol. 52 (2014) 607-632.
|
25 |
W.G. Liu, R.D. Wang, L. Hua, W.F. He, Seismic isolation response and parameter influence analysis of nuclear power plant during great earthquake, Appl. Mech. Mater. 166-169 (2012) 2275-2282.
DOI
|
26 |
Y.N. Huang, A.S. Whittaker, R.P. Kennedy, R.L. Mayes, Response of baseisolated nuclear structures for design and beyond-design basis earthquake shaking, Earthq. Eng. Struct. Dynam. 42 (2013) 339-356.
DOI
|
27 |
ASCE/SEI Standard 43-05, Seismic Design Criteria for Structures, Systems, and Components in Nuclear Facilities, American Society of Civil Engineers, Reston, VA, 2005.
|
28 |
ASCE/SEI Standard 4-16, Seismic Analysis of Safety-Related Nuclear Structures, American Society of Civil Engineers, Reston, VA, 2017.
|
29 |
R. Gueraud, J.P. No€el-Leroux, M. Livolant, A.P. Michalopoulos, Seismic isolation using sliding-elastomer bearing pads, Nucl. Eng. Des. 84 (1985) 363-377.
DOI
|
30 |
A. Martelli, P. Clemente, M. Forni, G. Panza, A. Salvatori, Seismic Isolation of Nuclear Power Plants, in: Proceedings of the 15th World Conference on Earthquake Engineering, Lisbon, Portugal, 2012.
|
31 |
H. Lee, M. Cho, J. Park, Developing Lead Rubber Bearings for Seismic Isolation of Nuclear Power Plants, in: Proceedings of 15th World Conference on Earthquake Engineering, Lisbon, Portugal, 2012.
|