• Title/Summary/Keyword: High-efficieny

Search Result 7, Processing Time 0.02 seconds

Study on the Desalinization in Tiolal Land (간석지 제람에 관한 연구)

  • 이중기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.20 no.2
    • /
    • pp.4695-4707
    • /
    • 1978
  • The objeative of this study is to study how to rapidly convert tidal land into cultivable land. The study of a rapid, reasonable desalinization method is conducted at Namyang tidal land which represents soil texture of tidal lands along the south west costa larea of Korea. Therefore, Researches were made at many Pilots in order to find a way of high efficiency of leaching with simpler facilities and cheaper costs. The results of study are briefly summarized as follaws: 1. Subdrainage efficieny is 35%. This is a Poorly drained area, and needs longer leaching desalinization period. 2. The efficieny of desalinization in P.V.C 16 meters plot is the same as that of mole drainage 2 meters plot. P.V.C 4 meters plot has desalinization effect as much as two times compared to P.V.C 16 meters plot. 3. Because the soil texture is silty-clay, desalinization in non-treated plot of sub-drainage and surface drainage desalinization take three times longer period in comparision with P.V.C 4 meters plot. 4. As to the desalinization rate of soluble salt in the soil, the efficieny of desalinization of the topsoil in P.V.C plots was 50% higher than that of mole drainage plot and about 170% higher than that of non-treated plot. In the deep soil salt accumulation at topsoil was observed in non-treated and mole drainage plots, but efficiency in P.V.C polt is about 40 times as high as that of mole drainage and non-treated plot. 5. As to the results of use gypsum and lime as sub-drainage soil improver, gypsum was 60% more efficieny than lime in the continuously inundated plot and 44% in the intermittently inundated plot. The efficieny of gypsum and lime in the intermittently flooded plot is 35% and 42% higher than that of continuously flooded plot reapeaticee1y.

  • PDF

Financial Structural and Operational Characteristics and Management Decision-making Behavior of the Red-figured Hospitals (적자병원의 재무구조 및 운영적 특성과 경영의사결정 행태)

  • Hwang, In-Kyoung
    • Korea Journal of Hospital Management
    • /
    • v.4 no.2
    • /
    • pp.305-329
    • /
    • 1999
  • Financial ratio indicators of the 46 sample hospitals provided by the Korea Health Industry Development Institute, together with the survey data responded by the 57 sample hospitals, were analysed to identify the characteristics of the red-figured hospitals' financial structure, financial operational efficiency and management decision-making behavior, The financial characteristics identified through the analysis include high dependency to liabilities, high salary expenses and overhead costs, low profitability of the unduly large amount of fixed assets, and low managerial efficieny of inventory. The hospitals, in face of the IMF economic impasse, took the necessary decision-making and counter measures to cut down salary expenses, to increase the number of patient and medical revenue, and to reduce investment to fixed assets. Based on these findings this study suggested that the hospitals should take more active cost containment measures, financial structural reorganization, and developoment of the strategies that can contribute to increase of the number of patient and medical revenue and that do not. require much capital funds.

  • PDF

Frequency Adaptive High Efficiency Class-E Amplifier in RFID System (RFID 시스템에 사용되는 주파수 적응형 고효율 Class-E 증폭기)

  • Kwan, Sang-Gun;Son, Gang-Ho;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.3
    • /
    • pp.351-357
    • /
    • 2010
  • This paper proposes the adaptive class-E power amplifier with maintaining high power added efficiency (PAE) to apply RFID and wireless communication system. This switch mode amplifier is used a microprocessor to control a resonator circuits and to maintain high efficiency in case of input frequency variation. To validate the adaptive amplifier operation, which is a 450MHz operating frequency and a 100MHz bandwidth, the class E amplifier is implemented. As a result, the adaptive amplifier is maintained above 60% efficiency in frequency range and has a 74.8% maximum efficiency.

A 3.3V, 68% power added efficieny, GaAs power MESFET for mobile digital hand-held phone (3.3V 동작 68% 효율, 디지털 휴대전화기용 고효율 GaAs MESFET 전력소자 특성)

  • 이종남;김해천;문재경;이재진;박형무
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.6
    • /
    • pp.41-50
    • /
    • 1995
  • A state-of-the-arts GaAs power metal semiconductor field effect transistor (MESFET) for 3.3V operation digital hand-held phone at 900 MHz has been developed for the first time, The FET was fabricated using a low-high doped structures grown by molecular beam epitaxy (MBE). The fabricated MESFETs with a gate width of 16 mm and a gate length of 0.8 .mu.m shows a saturated drain current (Idss) of 4.2A and a transconductance (Gm) of around 1700mS at a gate bias of -2.1V, corresponding to 10% Idss. The gate-to-drain breakdown voltage is measured to be 28 V. The rf characteristics of the MESFET tested at a drain bias of 3.3 V and a frequencyof 900 MHz are the output power of 32.3 dBm, the power added efficiency of 68%, and the third-ordr intercept point of 49.5 dBm. The power MESFET developed in this work is expected to be useful as a power amplifying device for digital hand-held phone because the high linear gain can deliver a high power added efficiency in the linear operation region of output power and the high third-order intercept point can reduce the third-order inter modulation.

  • PDF

Texturing Effects on High Efficiency Silicon Buried Contact Solar Cell (전극 함몰형 고효율 실리콘 태양전지에서의 texturing 효과)

  • 지일환;조영현;이수홍
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.172-176
    • /
    • 1995
  • Schemes to trap weakly absorbed light into the cell have played an important role in improving the efficiency of both amorphous and crystlline silicon solar cells. One class of scheme relies on randomizing the direction of light within the cell by use of Lambertian(diffuse)surfaces. A second class of scheme relies on the use fo well defined geometrical features to control the direction of light wihin the cell, Widly used geometrical features in crystalline silicon solar cells are the square based pyramids and V-shaped grooves formed in (100) orientated surfaces by intersecting(III) crystallographic planes exposed by anisotropic etching. 18.5% conversion efficiency of Buried Contact Solar Cell with pyramidally textured surface has been achieved. 18.5% efficiency of silicon solar cell is one the highest record in the world The efficieny of cell without textured surface was 16.6%, When adapting textured surface to the Cell, the efficiency has been improved over 12%.

  • PDF

A Study on the Development of High Efficieny $CO_2$ Laser : Output Characteristics of Pulsed $CO_2$ Laser Using SMPS Method (고효율 $CO_2$ Laser 개발 연구 : SMPS 방식 펄스형 $CO_2$ Laser의 출력특성)

  • Chung, Hyun-Ju;Lee, Dong-Hoon;Nam, Gyung-Hoon;Kim, Do-Wan;Chung, Young-Hwan;Lee, Yu-Soo;Kim, Hee-Je;Cho, Jung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.730-734
    • /
    • 1999
  • In this study, it is the purpose to develope a cheap and compact repetitively pulsed $CO_2$ laser with pulse repetition rate range of 180 Hz. We used a SCR switched power supply as a high voltage pulsed supply, which is cheap and simple comparing to others. PIC one-chip microprocessor was used for precise control of a laser power supply on the control part. And the laser cavity was fabricated as an axial and water cooled type. The laser performance characteristics as various parameters, such as pulse repetition rate and gas pressure have been investigated. The experiment was done under the condition of total pressure of $CO_2, N_2$ and He from 4 Torr to 16 Torr and pulse repetition rate from 4 Hz to 180 Hz. As a result, the maximum average output was about 19.6W at the total pressure of 12 Torr and the pulse repetition rate of 180Hz.

  • PDF

Effects of Exhaust Gas Recirculation on Power and Thermal Efficiency of Reactivity Controlled Compression Ignition in Different Load Conditions with a 6-L Engine (6 L급 압축착화 기관에서 천연가스-디젤 반응성 조정 연소 시 부하에 따른 배기 재순환율이 출력 및 열효율에 미치는 영향 분석)

  • Lee, Sunyoup;Lee, Seok-Hwan;Kim, Chang-Gi;Lee, Jeong-Woo
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.6
    • /
    • pp.1-10
    • /
    • 2020
  • Reactivity controlled compression ignition (RCCI) combustion is one of dual-fuel combustion systems which can be constructed by early diesel injection during the compression stroke to improve premixing between diesel and air. As a result, RCCI combustion promises low nitrogen oxides (NOx) and smoke emissions comparing to those of general dual-fuel combustion. For this combustion system, to meet the intensified emission regulations without emission after-treatment systems, exhaust gas recirculation (EGR) is necessary to reduce combustion temperature with lean premixed mixture condition. However, since EGR is supplied from the front of turbocharger system, intake pressure and the amount of fresh air supplementation are decreased as increasing EGR rate. For this reason, the effect of various EGR rates on the brake power and thermal efficiency of natural gas/diesel RCCI combustion under two different operating conditions in a 6 L compression ignition engine. Varying EGR rate would influence on the combustion characteristic and boosting condition simultaneously. For the 1,200/29 kW and 1,800 rpm/(lower than) 90 kW conditions, NOx and smoke emissions were controlled lower than the emission regulation of 'Tier-4 final' and the maximum in-cylinder pressure was 160 bar for the indurance of engine system. The results showed that under 1,200 rpm/29 kW condition, there were no changes in brake power and thermal efficiency. On the other hand, under 1,800 rpm condition, brake power and thermal efficieny were decreased from 90 to 65 kW and from 37 to 33 % respectively, because of deceasing intake pressure (from 2.3 to 1.8 bar). Therefore, it is better to supply EGR from the rear of compressor, i.e. low pressure EGR (LP-EGR) system, comparing to high pressure EGR (HP-EGR) for the improvement of RCCI power and thermal efficiency.