• 제목/요약/키워드: High-cost imaging test

검색결과 14건 처리시간 0.029초

민간의료보험 가입자와 미가입자 간 외래 고가영상검사 이용의 격차: 건강보험 보장성 강화 정책에 따른 변화 (Disparities in High-cost Outpatient Imaging Test Utilization between Private Health Insurance Subscribers and Non-subscribers: Changes Following the National Health Insurance Benefit Expansion Policy)

  • 신유경;도영경
    • 보건행정학회지
    • /
    • 제33권3호
    • /
    • pp.325-337
    • /
    • 2023
  • Background: While there are many studies estimating the effects of private health insurance on various types of health care utilization, few have examined how such effects change in conjunction with important policy reforms in national health insurance (NHI). This study examined how the effect of private health insurance (supplemental and fixed cash benefit) on high-cost outpatient imaging test utilization changed following the expansion of magnetic resonance imaging (MRI) coverage in 2018, which is a key example of the NHI benefit expansion policy in recent years. Methods: Data from the 2017 and 2019 Korea Health Panel Survey, which contained information about healthcare utilization before and after the expansion of MRI coverage in 2018, were used. The incremental effect of private health insurance on high-cost outpatient imaging test utilization for each period were quantified and compared, with special attention given to the type of private health insurance. Results: While people with supplemental private health insurance were more likely to use high-cost outpatient imaging tests than those without, both before and after the expansion of MRI coverage, the incremental effect increased from 1.6% points in 2017 to 2.5% points in 2019. Conclusion: Benefit expansion in NHI does not necessarily reduce disparities in the use of health care between private health insurance subscribers and non-subscribers. The results of our study also suggest that the path through which private health insurance affects healthcare utilization may not be limited to the price mechanism alone but can be more complex.

TEST MODEL OF MILLIMETER-WAVE IMAGING RADIOMETER EQUIPMENT (MIRAE)

  • Lee, Ho-Jin;Kim, Won-Gyum;Seong, Jin-Taek;Kim, Dae-Suk;Na, Kyoung-Tae;Jung, Min-Kyoo;Chang, Yu-Shin;Kim, Soon-Tae;Kim, Yong-Hoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.365-368
    • /
    • 2007
  • Millimeter-wave (MMW) imaging radiometer systems have an attractive advantage to obtain an image through low visibility weather conditions such as fog, clouds and light rain compared with visible and infrared imaging systems. Many countries have developed a various kinds of MMW imaging radiometers for the aim of low cost and high performance. In Korea, Millimeter-wave Imaging RAdiometer Equipment (MIRAE) has been developed since the end of 2006. Recently the development of some modules was finished for the test model. This paper describes the design and development of the MIRAE. In addition, the test results of its manufactured modules are presented.

  • PDF

활동기준 원가분석을 통한 건강보험수가의 적정성 분석 (An Analysis on Appropriateness of Health Insurance Fee Using the Activity Based Costing(ABC) Approach)

  • 김한성;신현웅;차재영
    • 한국병원경영학회지
    • /
    • 제20권3호
    • /
    • pp.36-44
    • /
    • 2015
  • The Activity Based Costing(ABC) means the process that makes clear how the actions and input resources have changed into service to calculate medical services costs. These days, the number of hospital which is using the ABC system is increasing to make their policy decision making efficient and run the hospitals more resonable. This study analyzes the unbalance in the level of health insurance service fee and the improvement plans based from 8 hospitals(ABC system) and 95 clinics(ABC survey). The cost recovery ratio has shown different levels according to each service type. A surgery service type recorded 76.8% and an evaluation & management service type is 84.6%, a treatment procedure type(85.8%), a function test type(91.6%) and health insurance fee even did not reach to the original cost. Meanwhile, a laboratory test type and imaging test type show high level of cost recovery ratio. they recorded 188.3% and 158.8%. Resultingly now of unbalance in the level of health insurance service fee accelerates supply of every test. so there is a need to make laboratory test type and imaging test type lower to keep balance with the surgery and medical service. These methods should be performed gradually with monitoring the unbalance fee ratio and for this, a panel medical institution have to be established for generalizations of studying result, fairness of selecting researching sample.

연부 조직 종양에서 PET의 유용성: 기존의 진단법과의 비교 연구 (Diagnostic Efficacy of PET in Soft Tissue Tumors: Comparative Study with Conventional Methods)

  • 서성욱;박상민;조환성
    • 대한골관절종양학회지
    • /
    • 제11권1호
    • /
    • pp.32-39
    • /
    • 2005
  • 목적: 최근에는 연부 종양의 진단에 FDG-PET을 이용하기 위한 연구가 다양하게 이루어지고 있다. 그러나, 그 임상적 유용성에 대해서는 알려져 있지 않다. 이 연구의 목적은 기존의 진단법과 비교하여 FDG-PET의 유용성을 평가하는 데 있다. 대상 및 방법: 연구 대상은 2001년 3월에서 2002년 3월 사이에 연부 조직 종양으로 진단받은 29명의 환자(남자 16명, 여자 13명, 평균 47세)를 대상으로 하였다. 모든 환자군에서 기존의 검사법과 FDG-PET을 시행하였다. 타당성 검증에서 국소 병변은 모든 경우 조직검사로 판단하였고, 전이 병변은 조직 검사와 6개월 간의 추시 결과로 판단하였다. 각각의 진단은 독립적으로 시행되었으며, 진단의 정확도와 누적 비용-정확도율을 측정하였다. 결과: 국소 병변의 진단에서 MRI와 FDG-PET의 민감도, 특이도, 정확도는 각각 91%, 57%, 83% 와 95%, 43%, 83%이었다. 원격 전이의 진단에서 기존의 검사법과 FDG-PET의 민감도, 특이도, 정확도는 각각 77%, 89%, 87% 와 92%, 94%, 93%이었다. 누적 비용-정확도율은 145,000원/% 이었다. 종양의 등급별 민감도 분석에서 고등급의 종양이 가장 비용-효용성이 높았다. 결론: 국소부위의 재발과 잔존 종양의 진단에서 FDG-PET의 정확도는 MRI와 차이가 없었다. 반면, 원격 전이의 진단은 FDG-PET이 기존의 검사 보다 정확하였다. 고등급 종양의 경우 저등급 종양보다 FDG-PET의 유용성이 큰 것을 알 수 있었다.

  • PDF

Calculation of Tree Height and Canopy Crown from Drone Images Using Segmentation

  • Lim, Ye Seul;La, Phu Hien;Park, Jong Soo;Lee, Mi Hee;Pyeon, Mu Wook;Kim, Jee-In
    • 한국측량학회지
    • /
    • 제33권6호
    • /
    • pp.605-614
    • /
    • 2015
  • Drone imaging, which is more cost-effective and controllable compared to airborne LiDAR, requires a low-cost camera and is used for capturing color images. From the overlapped color images, we produced two high-resolution digital surface models over different test areas. After segmentation, we performed tree identification according to the method proposed by , and computed the tree height and the canopy crown size. Compared with the field measurements, the computed results for the tree height in test area 1 (coniferous trees) were found to be accurate, while the results in test area 2 (deciduous coniferous trees) were found to be underestimated. The RMSE of the tree height was 0.84 m, and the width of the canopy crown was 1.51 m in test area 1. Further, the RMSE of the tree height was 2.45 m, and the width of the canopy crown was 1.53 m in test area 2. The experiment results validated the use of drone images for the extraction of a tree structure.

A Coaxial and Off-axial Integrated Three-mirror Optical System with High Resolution and Large Field of View

  • Chen, Zhe;Zhu, Junqing;Peng, Jiantao;Zhang, Xingxiang;Ren, Jianyue
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.94-100
    • /
    • 2016
  • A novel optical design for high resolution, large field of view (FOV) and multispectral remote sensing is presented. An f/7.3 Korsch and two f/17.9 Cook three-mirror optical systems are integrated by sharing the primary and secondary mirrors, bias of the FOV, decentering of the apertures and reasonable structure arrangement. The aperture stop of the Korsch system is located on the primary mirror, while those of the Cook systems are on the exit pupils. High resolution image with spectral coverage from visible to near-infrared (NIR) can be acquired through the Korsch system with a focal length of 14 m, while wide-field imaging is accomplished by the two Cook systems whose focal lengths are both 13.24 m. The full FOV is 4°×0.13°, a coverage width of 34.9 km at the altitude of 500 km can then be acquired by push-broom imaging. To facilitate controlling the stray light, the intermediate images and the real exit pupils are spatially available. After optimization, a near diffraction-limited performance and a compact optical package are achieved. The sharing of the on-axis primary and secondary mirrors reduces the cost of fabrication, test, and manufacture effectively. Besides, the two tertiary mirrors of the Cook systems possess the same parameters, further cutting down the cost.

고속 디지털 MRI 모뎀 수신기 설계 (Design of Receiver in High-Speed digital Modem for High Resolution MRI)

  • 염승기;양문환;김대진;정관진;김용권;권영철;최윤기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(1)
    • /
    • pp.69-72
    • /
    • 2000
  • This paper shows the more improved design of MRI receiver compared to conventional one based on Elscint Spectrometer. At first, the low-cost ADC is 16 bits, 3MHz sampling A/D converter Comparing to conventional one with signal bits of 14 bits, this device with those of 16 bits helps getting Improved the image resolution improved. If frequency is designed centering around 7.6 MHz to be satisfied in 10 MHz of maximum input bandwidth of ADC. For 1st demodulation, fixed IF is used for the purpose of the implementing multi nuclei system. Control parts & partial digital parts are integrated on one chip(FPGA). In DDC(Digital Down Converter), we got required bandwidth of LPF by controlling its decimation rate. With above considerations, we designed optimal receiver for high resolution imaging to be implemented through PC interface & experimental test of receiver of MRI after receiver's fabrication.

  • PDF

드론 탐지 및 분류를 위한 레이다 영상 기계학습 활용 (Machine learning based radar imaging algorithm for drone detection and classification)

  • 문민정;이우경
    • 한국정보통신학회논문지
    • /
    • 제25권5호
    • /
    • pp.619-627
    • /
    • 2021
  • 최근 드론은 가격 하락, 소형화와 함께 높은 기술 발전에 힘입어 드론 보급이 민군에 걸쳐 증가하면서 보안안전사고, 치안·안보 위협 등의 문제를 유발할 가능성도 커지고 있다. 드론으로 인해 발생하는 사건 및 사고를 예방하기 위해서는 드론의 출현에 대응할 수 있는 탐지 기술이 우선적으로 선행되어야 한다. 드론은 크기가 작고 전파 반사도가 낮은 재질로 구성되어 있어 음향, 적외선, 레이다의 운용만으로는 탐지가 어렵다. 최근 영상 식별 성능을 강화하기 위해 레이다 신호에 인공지능을 접목한 연구사례가 증가하는 추세이다. 본 논문에서는 레이다 영상을 이용한 드론 탐지 기술을 소개하며, 드론의 모의실험 데이터와 실제 실험 데이터를 기반으로 인공지능 기술에 적용하여 드론의 분류 정확도를 효과적으로 입증하였다.

유도무기의 비행시험 결과 예측 및 분석을 위한 현장 영상 기반 시뮬레이션 기법 연구 (Study on On-Sight Image-Based Simulation Method for Predicting and Analyzing Flight Test Results of a Missile)

  • 정동길;박진서;이종희;손성한
    • 한국시뮬레이션학회논문지
    • /
    • 제28권3호
    • /
    • pp.41-48
    • /
    • 2019
  • 현대전에서 중시되는 부수피해 최소화를 위한 정밀타격 유도무기에는 적외선 영상탐색기가 주로 적용되는데, 고가의 적외선 센서를 탑재한 일회성 유도무기의 성능평가에는 많은 비용이 소모되게 된다. 이러한 비용 소모를 최소화하기 위해 시뮬레이션 기법을 통해 유도무기의 성능 예측을 수행하는데, 합성 적외선 영상을 적용한 시뮬레이션 기법이 대표적이다. 하지만 합성영상 적용 기법은 실제 영상과의 특성 차 및 다양한 환경 조건에 따라 변화하는 영상의 특성을 모두 고려하기 힘들다는 제한 사항을 가진다. 본 논문에서는 기존의 시뮬레이션 제한 사항을 보완하기 위한 계측 영상 기반 시뮬레이션 기법을 제안한다. 유도탄 발사 전에 획득되는 영상은 표적의 대조비 또는 온도차 등을 확인하여 영상 추적기의 성능발휘 조건 판단 목적으로만 적용되어 왔으나, 낮은 해상도 및 정보량 부족으로 통합 비행 시뮬레이션에 적용되는 시도조차 없었다. 하지만 본 논문에 기술한 연구를 통하여 현장 계측 영상을 적용한 통합 비행 시뮬레이션은 초기, 중기 비행 간의 유도탄 비행 성능을 상당히 유사하게 예측할 수 있으며 비행시험 결과 분석에 유용하게 활용할 수 있음을 확인하였다.

뇌졸중 고령자와 정상인의 보행 시 족압 변화 및 비교 분석 (Comparison Analysis of Foot Pressure Characteristics during Walking in Stroke and Normal Elderly)

  • 정남교;박세진;권순현;전종암;유재학
    • Journal of Platform Technology
    • /
    • 제9권3호
    • /
    • pp.36-43
    • /
    • 2021
  • 뇌졸중 질환은 전세계적으로 가장 중요한 사망원인 중 하나이며, 특히 고령자에게 장애의 원인이 되는 가장 중요한 질환이다. 뇌졸중 질환이 발생하면 사망 또는 심각한 장애를 유발하기 때문에, 적극적인 일차 예방과 전조증상의 빠른 발견이 매우 중요하다. 특히, 일상생활에서의 뇌졸중 전조증상 발병을 감지 및 정확히 예측하여 전문가의 신속한 진단을 유도할 수 있어야 한다. 최근까지의 연구에서는 뇌졸중 환자의 전조증상을 예측하는 방법론으로 CT(Computed Tomography)나 MRI(Magnetic Resonance Imaging)와 같은 영상 분석이 대부분이었으나, 이러한 접근에는 오랜 검사 시간과 높은 검사 비용 등에 대한 한계점을 가지고 있다. 본 논문에서는 고령자의 뇌졸중 질환 발병이 보행 시 족압(Foot Pressure)에 어떤 영향을 미치는지 임상 데이터를 이용해 실험하였다. 실험 결과, 보행 중에 뇌졸중 고령자와 일반 고령자 간에 12개의 셀에서 * p < .05 인 유의미한 차가 있음을 분석 및 검증하였다. 결과적으로 고령의 뇌졸중 환자와 일반 고령자의 일상생활의 보행 패턴에 유의미한 차이를 발견했다는 것에 그 의미가 크다고 할 수 있다.