• 제목/요약/키워드: High-Voltage

검색결과 10,497건 처리시간 0.042초

Regulation of $Ba^{2+}$-Induced Contraction of Murine Ureteral Smooth Muscle

  • Kim, Young-Chul;Lee, Moo-Yeol;Kim, Wun-Jae;Myung, Soon-Chul;Choi, Woong;Kim, Chan-Hyung;Xu, Wen-Xie;Kim, Seung-Ryul;Lee, Sang-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제11권5호
    • /
    • pp.207-213
    • /
    • 2007
  • This study was designed to characterize ureteral smooth muscle motility and also to study the effect of forskolin(FSK) and isoproterenol(ISO) on smooth muscle contractility in murine ureter. High $K^+$(50 mM) produced tonic contraction by $0.17{\pm}0.06mN$(n=19). Neuropeptide and neurotransmitters such as serotonin($5{\mu}M$), histamine($20{\mu}M$), and carbarchol(CCh, $10{\sim}50{\mu}M$) did not produce significant contraction. However, CCh($50{\mu}M$) produced slow phasic contraction in the presence of 25 mM $K^+$. Cyclopiazonic acid(CPA, $10{\mu}M$), SR $Ca^{2+}$-ATPase blocker, produced tonic contraction(0.07 mN). Meanwhile, inhibition of mitochondria by protonophore carbnylcyanide m-chlorophenylhydrazone(CCCP) also produced weak tonic contraction(0.01 mN). The possible involvement of $K^+$ channels was also pursued. Tetraethyl ammonium chloride(TEA, 10 mM), glibenclamide($10{\mu}M$) and quinidine($20{\mu}M$) which are known to block $Ca^{2+}$-activated $K^+$ channels($K_{Ca}$ channel), ATP-sensitive $K^+$ channels($K_{ATP}$) and nonselective $K^+$ channel, respectively, did not elicit any significant effect. However, $Ba^{2+}$($1{\sim}2mM$), blocker of inward rectifier $K^+$ channels($K_{IR}$ channel), produced phasic contraction in a reversible manner, which was blocked by $1{\mu}M$ nicardipine, a blocker of dehydropyridine-sensitive voltage-dependent L-type $Ca^{2+}$ channels($VDCC_L$) in smooth muscle membrane. This $Ba^{2+}$-induced phasic contraction was significantly enhanced by $10{\mu}M$ cyclopiazonic acid(CPA) in the frequency and amplitude. Finally, regulation of $Ba^{2+}$-induced contraction was studied by FSK and ISO which are known as adenylyl cyclase activator and $\beta$-adrenergic receptor agonist, respectively. These drugs significantly suppressed the frequency and amplitude of $Ba^{2+}$-induced contraction(p<0.05). These results suggest that $Ba^{2+}$ produces phasic contraction in murine ureteral smooth muscle which can be regulated by FSK and $\beta$-adrenergic stimulation.

체질량지수에 따른 심장 CT검사의 수동노출조절 방법과 자동노출조절 방법의 방사선량 및 화질 평가 (Evaluation of Radiation Dose and Image Quality Between Manual and Automatic Exposure Control Mode According to Body Mass Index in Cardiac CT)

  • 김형진;문일봉;한재복;최남길;장성주
    • 한국콘텐츠학회논문지
    • /
    • 제13권4호
    • /
    • pp.290-299
    • /
    • 2013
  • 건강검진 목적으로 심장 CT검사를 시행한 198명의 대상자 중 수동노출조절 방법(n=123)의 대조군과 자동노출조절 방법(n=75)의 실험군으로 BMI에 따라 Grade 1(BMI < 23kg/$m^2$), Grade 2(23 $$\leq_-$$ BMI < 25kg/$m^2$), Grade 3(25 $$\leq_-$$ BMI < 30kg/$m^2$), Grade 4(30 $$\leq_-$$ BMI kg/$m^2$)로 분류하고 영상의 질을 객관적, 주관적 평가로 분석하였고 방사선량을 비교하였다. 자동노출조절 방법을 사용하였을 때 모든 Grade에서 관전압이 유의하게 감소하였고, $CTDI_{vol}$, effective dose 값은 Grade 2에서는 통계적으로 유의하지 않게 감소하였으나 Grade 1, 3, 4에서는 유의하게 감소하였다(p<0.05). SNR은 Grade 1에서 유의하게 감소하였고 Grade 3에서는 유의하게 증가하였지만(p<0.05) Grade 2와 4에서는 유의한 차이가 없었다(p>0.05). CNR은 Grade 1에서 유의하게 감소하였고(p<0.05), Grade 2, 3, 4에서는 유의한 차이는 없었다(p>0.05). 영상의 주관적인 평가에서도 두 그룹간의 모든 Grade에서 유의한 차이가 없었다(p>0.05). 결론적으로 자동노출조절 방법은 수동노출조절 방법에 비해 영상의 주관적 평가는 변하지 않으면서도 피폭선량을 줄일 수 있는 유용한 방법으로 나타났다.

충전복극전해조에 의한 암모니아성 및 질산성 질소의 전해처리 (Electrolytic Treatment of Ammonium Nitrogen and Nitrate Nitrogen by Bipolar Packed Bed Electrolytic Cell)

  • 윤철종;유현철;김정섭;이봉섭;곽명화;박승조
    • 대한환경공학회지
    • /
    • 제27권7호
    • /
    • pp.686-689
    • /
    • 2005
  • 회분식 및 연속식 충전 복극전해조 사용시 인가전압, 전해시간 및 활성탄 충진고 등이 암모니아성 및 질산성 질소 제거에 미치는 영향을 검토할 목적으로 실험하였다. 회분식 충전복극 전해조에 $4{\times}8$ mesh GAC를 충전한 후 20 V의 전위에서 30분간 전해한 결과 활성탄 충진고가 80 mm인 경우 암모니아성 질소 제거효율은 전해시간 30분에서 99.9%, 질산성 질소 제거효율은 전해시간 60분에서는 97.6%이었다. 그리고 암모니아성 및 질산성 질소를 연속식으로 처리시 활성탄을 280 mm 충전한 충전복극전해조에 총 질소 농도가 30 mg/L가 되도록 조제한 질산암모늄 시료를 6.7 mL/min 속도로 주입하면서 72시간 연속전해 결과 총 질소 제거효율은 약 80% 이상이었다.

콘크리트내 염소이온량이 전기저항에 미치는 영향 (Influence of Chloride Content of on Electrical Resistivity in Concrete)

  • 윤인석;남진원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권6호
    • /
    • pp.90-96
    • /
    • 2014
  • 콘크리트의 전기저항은 철근부식 개시 이전인 잠복기와 철근부식되는 진전기 두과정과 유관된다. 염소이온에 노출된 콘크리트 구조물의 전기저항은 초기 부식율의 위험도를 표현할 수 있는데, 낮은 전기저항은 빠른 염소이온 침투와 높은 부식속도를 의미하기 때문이다. 콘크리트의 전기저항은 인가된 전압과 전류간의 비율인 전기저항으로 표현된다. 이전의 연구에 의하면 콘크리트의 전기저항은 콘크리트내 수분량, 미세구조 및 탄산화 등에 크게 의존하였다. 습윤량과 전기저항의 관계를 다룬 연구가 적지만 존재하는 반면, 염소이온이 전기저항에 미치는 연구를 행한 연구는 매우 드물다. 본 연구의 목적은 염소이온이 콘크리트의 전기저항에 미치는 영향을 고찰하는 것이다. 실험결과에 의하면 염소이온량은 전기저항을 떨어뜨리는 것으로 나타났으며 이는 선형의 관계가 성립되었다. 초기 양생 50일 이전까지 전기저항의 감소추세는 뚜렷하였으며, 이후로는 염소이온량과 상관없이 일정하였다. 결과적으로 본 연구는 염소이온량을 함유한 콘크리트의 전기저항을 표현하는데 결정적인 방법을 제안하였다.

22 kV 케이블의 누설전류 및 절연저항의 선형적 변화 (A Linear Change of Leakage Current and Insulation Resistance of 22 kV Cables)

  • 엄기홍;이관우
    • 한국인터넷방송통신학회논문지
    • /
    • 제15권3호
    • /
    • pp.169-173
    • /
    • 2015
  • 이 논문은 사용한지 13년 지난 운전 중 22 kV 케이블시스템을, 7년 동안 절연저항을 측정하여 그 결과를 연구한 논문이다. 우리는 발전소에서 설치 운전 중인 고전압 케이블이 시간에 따라 성능이 악화되는 현상의 추세를 결정하는 수명지수를 파악하였다. 위한 논문이다. 케이블 시스템은 시간에 따라 절연 저항이 감소한다. 초기 케이블 시스템은 아레니우스 열화 곡선을 따른다. 초기에는 수명 지수 n값이 9로 설계하였고, 이후 n값을 상향하여 16으로 결정하였다. 이유는 고전압에서 케이블이 동작할 경우, n값이 클 때 파괴특성이 높지 않고, n값이 낮은 값에서 파괴특성이 높았기 때문이다. 그러나 전압열화에 의하여 와이블 프롯을 따른 v-t 특성에 의하여 n값은 10~11의 값을 갖는 것을 확인하였다. 과거 케이블 설계 시 정한 n=9의 이론적 근거와 n=16 으로 높아진 원인을 파악함으로써 누설 전류 및 절연 저항의 선형적인 변화를 확인하였다. 단기적으로는 운전 중 케이블 시스템의 진단 평가에 활용되며, 장기적으로는 발전소 부하에서 동작 중인케이블 시스템의 설치 및 운영에 있어서 원가를 절감하기 위한 노력에 기여하고자 한다.

Effects of Curing Temperature on the Optical and Charge Trap Properties of InP Quantum Dot Thin Films

  • Mohapatra, Priyaranjan;Dung, Mai Xuan;Choi, Jin-Kyu;Jeong, So-Hee;Jeong, Hyun-Dam
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.263-272
    • /
    • 2011
  • Highly luminescent and monodisperse InP quantum dots (QDs) were prepared by a non-organometallic approach in a non-coordinating solvent. Fatty acids with well-defined chain lengths as the ligand, a non coordinating solvent, and a thorough degassing process are all important factors for the formation of high quality InP QDs. By varying the molar concentration of indium to ligand, QDs of different size were prepared and their absorption and emission behaviors studied. By spin-coating a colloidal solution of InP QD onto a silicon wafer, InP QD thin films were obtained. The thickness of the thin films cured at 60 and $200^{\circ}C$ were nearly identical (approximately 860 nm), whereas at $300^{\circ}C$, the thickness of the thin film was found to be 760 nm. Different contrast regions (A, B, C) were observed in the TEM images, which were found to be unreacted precursors, InP QDs, and indium-rich phases, respectively, through EDX analysis. The optical properties of the thin films were measured at three different curing temperatures (60, 200, $300^{\circ}C$), which showed a blue shift with an increase in temperature. It was proposed that this blue shift may be due to a decrease in the core diameter of the InP QD by oxidation, as confirmed by the XPS studies. Oxidation also passivates the QD surface by reducing the amount of P dangling bonds, thereby increasing luminescence intensity. The dielectric properties of the thin films were also investigated by capacitance-voltage (C-V) measurements in a metal-insulator-semiconductor (MIS) device. At 60 and $300^{\circ}C$, negative flat band shifts (${\Delta}V_{fb}$) were observed, which were explained by the presence of P dangling bonds on the InP QD surface. At $300^{\circ}C$, clockwise hysteresis was observed due to trapping and detrapping of positive charges on the thin film, which was explained by proposing the existence of deep energy levels due to the indium-rich phases.

전동력설비의 운전에 의해 발생되는 자계의 측정과 해석 (Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations)

  • 이복희;길경석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권2호
    • /
    • pp.58-67
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]~0.234[mV/$\mu$T]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

  • PDF

7 dBi 이득을 가지는 이중 다이폴 준-야기 안테나 설계 (Design of Double-Dipole Quasi-Yagi Antenna with 7 dBi gain)

  • 여준호;이종익;백운석
    • 한국정보통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.245-252
    • /
    • 2016
  • 본 논문에서는 1.70-2.70 GHz 대역에서 7 dBi 이상의 이득을 가지는 이중 다이폴 준-야기 안테나(double-dipole quasi-Yagi antenna; DDQYA)의 설계에 관하여 연구하였다. 제안된 DDQYA 안테나는 두 개의 서로 다른 길이의 스트립 다이폴 안테나와 접지 반사기가 코플래너 스트립 선로로 연결되어 있다. 저주파수 대역에서 이득을 높이기 위해 두 번째 다이폴의 길이를 조절하였고, 중간 및 고주파수 대역에서 이득을 높이기 위해 직사각형 패치 도파기를 추가하였다. 두 번째 다이폴의 길이와 직사각형 패치 도파기의 길이와 폭에 따른 안테나의 특성 변화를 분석하여 7 dBi 이상의 이득을 얻기 위한 최종 설계 변수를 얻었다. 최종 설계된 DDQYA 안테나를 FR4 기판 상에 제작하고 특성을 실험한 결과 전압 정재파비(voltage standing wave ratio; VSWR)가 2 이하인 대역은 1.60-2.86 GHz이고, 1.70-2.70 GHz 대역에서 이득이 7.2-7.6 dBi로 7 dBi 이상을 유지하는 것을 확인하였다.

High resolution flexible e-paper driven by printed OTFT

  • Hu, Tarng-Shiang;Wang, Yi-Kai;Peng, Yu-Rung;Yang, Tsung-Hua;Chiang, Ko-Yu;Lo, Po-Yuan;Chang, Chih-Hao;Hsu, Hsin-Yun;Chou, Chun-Cheng;Hsieh, Yen-Min;Liu, Chueh-Wen;Hu, Jupiter
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.421-427
    • /
    • 2009
  • We successfully fabricated 4.7-inch organic thin film transistors array with $640{\times}480$ pixels on flexible substrate. All the processes were done by photolithography, spin coating and ink-jet printing. The OTFT-Electrophoretic (EP) pixel structure, based on a top gate OTFT, was fabricated. The mobility, ON/OFF ratio, subthreshold swing and threshold voltage of OTFT on flexible substrate are: 0.01 ^2/V-s, 1.3 V/dec, 10E5 and -3.5 V. After laminated the EP media on OTFT array, a panel of 4.7-inch $640{\times}480$ OTFT-EPD was fabricated. All of process temperature in OTFT-EPD is lower than $150^{\circ}C$. The pixel size in our panel is $150{\mu}m{\times}150{\mu}m$, and the aperture ratio is 50 %. The OTFT channel length and width is 20 um and 200um, respectively. We also used OTFT to drive EP media successfully. The operation voltages that are used on the gate bias are -30 V during the row data selection and the gate bias are 0 V during the row data hold time. The data voltages that are used on the source bias are -20 V, 0 V, and 20 V during display media operation.

  • PDF

Ru를 첨가한 음극활물질 Li4Ti5O12의 전기화학적 특성 (Electrochemical Characteristics of Ru Added Li4Ti5O12 as an Anode Material)

  • 조우람;나병기
    • 청정기술
    • /
    • 제20권4호
    • /
    • pp.433-438
    • /
    • 2014
  • 전기자동차와 하이브리드 전기자동차에 요구되는 높은 충 방전 속도, 안전성, 대형화에 적합한 충 방전 전지의 개발은 많은 관심을 받고 있다. 스피넬 구조의 $Li_4Ti_5O_{12}$는 리튬이온이차전지의 음극활물질로 충 방전 시 부피변화가 거의 없기 때문에 수명특성이 뛰어나고, 전해액이 분해되는 전위보다 높은 작동 전압을 갖기 때문에 안정한 장점이 있다. 본 실험에서는 $Li_4Ti_5O_{12}$의 단점인 전기전도성을 향상시키고자 소량의 Ru를 첨가하여 $Li_4Ti_5O_{12}$를 고상법으로 제조하여 테스트하였다. TGA-DTA, XRD, SEM, 충 방전 테스트를 통해 분석을 실시하였다. Ru를 첨가하였을 때 용량은 약간 감소하였지만, 분극현상이 감소하는 것을 확인하였다. 그리고 Ru를 3%와 4% 첨가하였을 때 높은 전류밀도인 10 C-rate 충 방전에서 용량감소율이 줄었다.