• 제목/요약/키워드: High-Tc

검색결과 1,526건 처리시간 0.036초

황색포도상구균의 테트라사이클린 내성 플라스미드 동정 (Characterization of Tetracycline Resistance Plasmids of Staphylococcus aureus)

  • 박정희;이재윤;문경호
    • 약학회지
    • /
    • 제52권4호
    • /
    • pp.279-282
    • /
    • 2008
  • Plasmids were isolated from 15 tetracycline (Tc) resistant S. aureus. Two small tetracycline resistance plasmids, pKH16 and pKH17, have been isolated from Staphylococcus aureus JY10 and Staphylococcus aureus JY22, respectively and the complete nucleotide sequences of those plasmids have been determined. pKH16 consisted of 4,442 bp and showed high identity to pKH6 (99% matching percentage) isolated in 1989 from S. aureus SA2. pKH17 consisted of 4,441 bp and showed less identity to pKH6 (95% matching percentage) than pKH16. PCR analysis showed that tetK and tetM did not exist in ten large plasmids isolated from ten Tc resistant S. aureus. Twelve Tc resistant S. aureus showed reistance both to Tc and Mn and we might analogize that twelve Tc resistant S. aureus had tetM in their chromosome.

GEANT4를 이용한 $^{99m}Tc$ Generator 안전성 시뮬레이션 ([ $^{99m}Tc$ ] Generator Safety Simulation Based on GEANT4)

  • 강상구;한동현;김종일
    • 한국의학물리학회지:의학물리
    • /
    • 제19권1호
    • /
    • pp.1-8
    • /
    • 2008
  • 테크니슘$(^{99m}Tc)$은 현재 핵의학 분야에서 진단용 방사선원으로 가장 널리 쓰이고 있는 방사성 동위원소 중 하나이다. 일반적으로 테크니슘은 $^{99m}Tc$ Generator라 불리는 장치 안에서 모핵종인 $^{99}Mo$의 붕괴를 통해 생산되는데, $^{99}Mo$$^{99m}Tc$에서 비교적 높은 방사선을 방출하기 때문에 이를 차폐하기 위하여 주로 납으로 제작되어 있다. 본 논문에서는 국내에서 비교적 사용 빈도가 높고 교정 방사능이 500 mCi인 일본 제품을 대상으로, 최대 방사능량 적제조건에서 차폐용기 표면으로부터 10 cm, 100 cm에서 각각 2.0 mSv/h, 0.02 mSv/h를 초과하지 않아야 한다는 국내 법적 제한치를 만족시키는지 여부를 GEANT4를 이용하여 시뮬레이션하였다. 계산 결과 용기 밖으로 방출되는 방사선량이 법적 기준치를 초과하지 않는 것으로 나타났다.

  • PDF

$^{201}Tl/^{99m}Tc$ 감영스캔으로 부갑상선종괴를 얼마나 찾을 수 있는가? (Is $^{201}Tl-^{99m}Tc$-Subtraction Scan an Accurate Diagnostic Method to Detect Parathyroid Mass?)

  • 양형인;김덕윤;김광원;최영길
    • 대한핵의학회지
    • /
    • 제28권1호
    • /
    • pp.31-36
    • /
    • 1994
  • $^{201}Tl-^{99m}Tc$ 감영스캔이 시행되었던 65명의 환자에서 $^{201}Tl-^{99m}Tc$ 감영스캔의 진단적 가치와 위 음성과 위 양성의 원인에 대해 조사하였다. 이들 중 21예가 부갑상선선종으로 확진되었고, 이들에서 $^{201}Tl-^{99m}Tc$ 감영스캔의 예민도는 90.5%, 특이도는 97.6%였다. 위 음성을 보인 예는 낭종성 괴사를 보인 부갑상선선종과 크기가 $1.5{\times}1{\times}0.8 cm$ 정도로 작은 종양이었다. 위 양성을 보인 1예는 무 기능성 갑상선종이었다. 결론적으로 $^{201}Tl-^{99m}Tc$ 감영스캔은 부갑상선 종괴를 찾아내는데 특이도와 예민도가 높은 검사로 생각된다.

  • PDF

감마선 순환 처리에 의한 Centipedegrass (Eremochloa ophiuroides)의 유전변이 유도 (Induction of Genetic Variation with Recurrent Gamma Radiation in Centipedegrass (Eremochloa ophiuroides))

  • 임근발;;임용우;김영진;한학석;성병렬;김준식
    • 한국초지조사료학회지
    • /
    • 제18권4호
    • /
    • pp.351-354
    • /
    • 1998
  • Centipedegrass는 미국 동남부지역에서 잔디용으로 많이 이용하고 있는데 토양을 가리지 않고 잘 자라며 잎이 연녹색이어서 잔디로서 선호도가 높다. 그러나 이 식물의 유전자원이 지니고 있는 유전변이 폭이 매우 한정되어 있어 활용 가능한 유전변이의 폭을 확대하기 위해 Centipedegrass의 종자에 감마선 10Kr을 조사한 뒤 계통을 조성하고 이를 다시 감마선 10Kr을 조사하여 계통을 조성하는형태로 순환 조사하여 순환 처리회수를 각각 0회, 4회, 5회, 6회, 8회 하여 얻은 계통집단 TC 201, TC 202, TC 241, TC 306, TC 318에 대하여 이들 계통집단이 지니고 있는 식물 형태적 특성의 평균과 변이의 범위 폭을 측정하여 비교한 결과 이미 품종으로 고정되어 있는 TC318을 제외하고 감마선을 종자에 순환처리한 계통집단에서 총지하경수, 총지하경길이, 최장지하경장, 엽장 및 엽폭의 변이폭이 감마선 조사로 확대되었음을 확인하였다. 이러한 변이의 범위 확대 정도는 지하경과 같은 생식기관에서 뚜렷하였는데 방사선 순환조사 정도와 관련하여 일정한 방향성은 인정되지 않았다.

  • PDF

항암치료 받는 악성 뇌종양 환자의 재발여부에 따른 지질프로필 비율의 비교 (Comparison of Lipid Profile Ratios in Patients with High-grade Brain Cancers according to the Presence of Recurrence during Cancer-related Therapy)

  • 김상희
    • Journal of Korean Biological Nursing Science
    • /
    • 제19권2호
    • /
    • pp.107-112
    • /
    • 2017
  • Purpose: The purpose of this study was to identify the lipid profile ratios as factors affecting disease progress in patients with high-grade primary brain cancers undergoing concurrent chemoradiotherapy (CCRT) and adjuvant chemotherapy. Methods: The levels of lipid profile ratios were evaluated by looking at the total cholesterol (TC) to high-density lipoprotein (HDL)-cholesterol (TC/HDL-c), low-density lipoprotein (LDL)-cholesterol to HDL-cholesterol (LDL-c/HDL-c), and triglycerides to HDL-cholesterol (TG/HDL-c). This descriptive research was conducted 7 months after the initiation of CCRT and adjuvant chemotherapy. Results: A total of 36 patients with newly diagnosed primary malignant brain cancer were included in the study. The levels of lipid profile ratios such as TC/HDL-c, LDL-c/HDL-c, TG/HDL-c were significantly different between the patients with and without disease progress at 7 months after initiation of CCRT and adjuvant chemotherapy. Conclusion: The lipid profile ratios were indicators affecting disease prognosis with tumor-related factors at 7 months after initiation of CCRT and adjuvant chemotherapy. Therefore, lipid profile ratios indicating hyperlipidemia in patients with high-grade brain cancers should be carefully monitored during and after cancer-related therapy.

$Site-Specific^{99m}$Tc-Labeling of Antibody Using Dihydrazinoph-thalazine (DHZ) Conjugation to Fc Region of Heavy Chain

  • Jeong, Jae-Min;Lee, Jae-Tae;Paik, Chang-Hum;Kim, Dae-Kee;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • Archives of Pharmacal Research
    • /
    • 제27권9호
    • /
    • pp.961-967
    • /
    • 2004
  • The development of an antibody labeling method with $^{99m}$Tc is important for cancer imaging. Most bifunctional chelate methods for $^{99m}$Tc labeling of antibody incorporate a $^{99m}$Tc chelator through a linkage to lysine residue. In the present study, a novel site-specific $^{99m}$Tc labeling method at carbohydrate side chain in the Fc region of 2 antibodies (T101 and rabbit anti-human serum albumin antibody (RPAb)) using dihydrazinophthalazine (DHZ) which has 2 hydrazino groups was developed. The antibodies were oxidized with sodium periodate to pro-duce aldehyde on the Fc region. Then, one hydrazine group of DHZ was conjugated with an aldehyde group of antibody through the formation of a hydrazone. The other hydrazine group was used for labeling with $^{99m}$Tc. The number of conjugated DHZ was 1.7 per antibody. $^{99m}$Tc labeling efficiency was 46-85% for T101 and 67∼87% for RPAb. Indirect labeling with DHZ conjugated antibodies showed higher stability than direct labeling with reduced antibodies. High immunoreactivities were conserved for both indirectly and directly labeled antibodies. A biodistribution study found high blood activity related to directly labeled T1 01 at early time point as well as low liver activity due to indirectly labeled T101 at later time point. However, these findings do not affect practical use. No significantly different biodistribution was observed in the other organs. The research concluded that DHZ can be used as a site-specific bifunctional chelating agent for labeling antibody with $^{99m}$Tc. Moreover, $^{99m}$Tc labeled antibody via DHZ was found to have excellent chemical and biological properties for nuclear medicine imaging.edicine imaging.

고속 플래시 AD 변환기를 위한 Successive Selection Encoder의 Logical Effort에 의한 설계 (Design of the Successive Selection Encoder by the Logical Effort for High Flash Speed ADC's)

  • 이기준;;김병수
    • 대한전자공학회논문지SD
    • /
    • 제42권4호
    • /
    • pp.37-44
    • /
    • 2005
  • 고속 flash ADC를 위하여, Successive Selection Encoder (SSE)라고 명명된 새로운 형태의 TC-to-BC encoder를 제안한다. 기존의 fat tree encoder가 OR 논리에 의하여 동작되는데 반하여, 제안된 SSE는 MUX 논리에 의하여 입력 TC 신호 들 중에서 직접 출력 BC 신호를 선택한다. 제안한 SSE의 구현을 위하여, Logical Effort 방법과 Hynix 0.25um 제조 공정에 의한 실험을 바탕으로 효율적인 SSE의 구현 구조를 정하였다. 이론적 모델과 실험 결과를 보면, SSE가 fat tree encoder에 비하여 (1) one-out-of-n 신호를 발생할 필요가 없고, (2) 사용되는 게이트 수는 약 1/3로 감소하며, (3) 동작속도는 2배 이상 빨라진다. 제안된 SSE는 고속 ADC에 적합한 TC-to-BC encoder로 사용될 수 있다.

온도/습도 시험, 온도 싸이클링 시험 및 고온유지 시험에 따른 Package-on-Package의 신뢰성 (Reliability Characteristics of a Package-on-Package with Temperature/Humidity Test, Temperature Cycling Test, and High Temperature Storage Test)

  • 박동현;오태성
    • 마이크로전자및패키징학회지
    • /
    • 제23권3호
    • /
    • pp.43-49
    • /
    • 2016
  • 박형 package-on-package에 대해 T/H (temperature/humidity) 시험, TC (temperature cycling) 시험과 HTS(high temperature storage) 시험을 사용하여 신뢰성을 분석하였다. T/H 시험은 $85^{\circ}C/85%$의 조건으로 500시간, TC 시험은 $-40{\sim}100^{\circ}C$의 조건으로 1000회, HTS 시험은 $155^{\circ}C$의 조건으로 1,000시간 범위에서 평가하였다. 폴리이미드 써멀테이프를 사용하여 제작한 24개의 package-on-package (PoP) 시편에 대해 신뢰성 시험 전에 측정한 솔더접속 배선의 평균저항은 $0.56{\pm}0.05{\Omega}$이었으며, 24개 시편에서 모두 유사한 값이 측정되었다. 500시간까지의 T/H 시험, 1000회의 TC 시험 및 1,000시간까지의 HTS 시험후에도 솔더 접속부의 오픈 불량은 발생하지 않았다.

악성 골 및 연부조직 종양에서 Tl-201 SCAN의 진단적 효능 - Tc-99m-MIBI 및 Tc-99m-MDP scan과의 비교 - (Thallium-201 Scan in Bone and Softtissue Sarcoma - Comparison with Tc-99m-MIBI and Tc-99m-MDP Scan -)

  • 신덕섭;조인호;안종철;안면환;이상호
    • 대한골관절종양학회지
    • /
    • 제2권1호
    • /
    • pp.1-7
    • /
    • 1996
  • PURPOSE : The purpose of this study is to know the ability of detecting malignant tumor tissue by Tl-201 scan, and to compare with that of Tc-99m-MIBI and Tc-99m-MDP scan. MATERIAL AND METHODS : Between February 1994 and December 1995,38 unselected patients with various bone pathologies were studied prospectively. Eighteen had malignant bone and soft tissue pathologies, while twenty had benign. All patients were studied with Tl-201, Tc-99mMIBI and Tc-99m-MDP scan prior to surgical biopsy. PICKER Prism 2000 gamma camera with high resolution parallel hole collimator was used for scanning. To avoid the interaction of isotope, the early(30min.) and delayed phase(3hrs.) of Tl-20l scan was performed first and Tc-99m-MIBI scan was performed after 30 minutes, and then Tc-99m-MDP scan 48 hours later. The scan images were visually evaluated by a blinded nuclear medicine physician. We could find true positive, true negative, false positive and false negative by the comparison of results with those of biopsy. We calculated positive and negative predictive value(%), sensitivity(%), specificity(%) and diagnostic accuracy(%) of each scan. RESULT : The results of each scan were 85.7, 100, 100, 85, 92.1% in Tl-201, 81, 94.1, 94.4, 80, 86.8% in Tc-99m-MIBI and 50, 66.7, 88.9, 20, 52.6% in Tc-99m-MDP scan. As a conclusion, Tl-201 scan was the most specific and accurate method for detecting malignant tumor tissue. Tc-99m-MIBI scan was also good for malignant tumor searching. CONCLUSION : With our results, we can use Tl-201 scan to differentiate benign from malignant tumor, and to evaluate the response of preoperative chemotherapy or radiotherapy, and to determine the residual tumor or local recurrence. For the better result, we need to have a more detail information about false positive cases and a more objective and quantitative reading technique.

  • PDF

$^{99m}Tc-DISIDA$를 이용한 간 혈류 중 동맥 분획의 측정 (Estimation of the Arterial Fraction of Total Hepatic Flow from Radionuclide Angiogram Using $^{99m}Tc-DISIDA$)

  • 이해규;임계연;양일권;김학희;임정익;박용휘;한석원;한남익;이영석
    • 대한핵의학회지
    • /
    • 제25권2호
    • /
    • pp.200-206
    • /
    • 1991
  • Arterial fraction of total hepatic blood flow was estimated by a new method, slope method, on radionuclid angiogram using $^{99m}Tc-DISIDA$ and was compared with that from $^{99m}Tc-Phytate$ radionuclide angiogram. This study included 11 of normal subjects, 37 of intermediate group with various liver diseases, and 25 patients with liver cirrhosis. We analyzed the datas with slope method from radionuclide angiograms and the results were compared with hepatic arterial fractions from uptake method, introduced by Lee et al. at 1986. The hepatic arterial fractions from radionuclide angiograms using $^{99m}Tc-DISIDA$ and $^{99m}Tc-Phytate$ were $0.32{\pm}0.09\;and\;0.31{\pm}0.11$ respectively in normal subjects, and $0.75{\pm}0.18\;and\;0.77{\pm}0.21$ respectively in patients with liver cirrhosis. The hepatic arterial fractions by the slope method was well correlated with those of the uptake method on $^{99m}Tc-DISIDA$ scan. There was high correlation between the hepatic arterial fractions from $^{99m}Tc-DISIDA$ and $^{99m}Tc-Phytate$ scans. Hepatic arterial fraction estimated by the slope method is a useful index for the diagnosis of liver cirrhosis and the evaluation of status of portal hypertension.

  • PDF