• Title/Summary/Keyword: High-Speed Transmission Line

Search Result 167, Processing Time 0.023 seconds

Transmission Characteristics of Indoor Infrared Diffuse Links Employing Three-Beam Optical Transmitters and Non-Imaging Receivers

  • Wang, Zan;Pan, Jae-Kyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.12A
    • /
    • pp.1251-1260
    • /
    • 2008
  • Diffuse wireless optical communication offers more robust optical links in terms of coverage and shadowing than line-of-sight links. However, traditional diffuse wireless infrared (IR) transceiver systems are more susceptible to multi-path distortion and great power decrease, which results in limiting high-speed performance. Multi-beam is an effective technique to compensate for multi-path distortion in a wireless infrared environment. The goal of this paper is to analyze the transmission characteristics by replacing traditional diffuse system (TDS) which contains single wide angle transmitter and single element receiver by system consisting of three-beam transmitter and non-imaging receiver (TNS) attached with compound parabolic concentrator (CPC). In the simulation, we use the recursive model developed by Barry and Kahn and build the scenario based on 10 different cases which have been listed in Table 1. Moreover, we also check the reliability of the TNS diffuse link channel by BER test on the basis of different receiver positions and room sizes. The simulation results not only show the basic transmission characteristics of TNS diffuse link, but also are references to design more efficient and reliable indoor infrared transmission systems.

Algorithm for Fault Location Estimation on Transmission Lines using Second-order Difference of a Positive Sequence Current Phasor

  • Yeo, Sang-Min;Jang, Won-Hyeok;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.499-506
    • /
    • 2013
  • The accurate estimation of a fault location is desired in distance protection schemes for transmission lines in order to selectively deactivate a faulted line. However, a typical method to estimate a fault location by calculating impedances with voltages and currents at relaying points may have errors due to various factors such as the mutual impedances of lines, fault impedances, or effects of parallel circuits. The proposed algorithm in this paper begins by extracting the fundamental phasor of the positive sequence currents from the three phase currents. The second-order difference of the phasor is then calculated based on the fundamental phasor of positive sequence currents. The traveling times of the waves generated by a fault are derived from the second-order difference of the phasor. Finally, the distance from the relaying point to the fault is estimated using the traveling times. To analyze the performance of the algorithm, a power system with EHV(Extra High Voltage) untransposed double-circuit transmission lines is modeled and simulated under various fault conditions, such as several fault types, fault locations, and fault inception angles. The results of the simulations show that the proposed algorithm has the capability to estimate the fault locations with high speed and accuracy.

Study on the integrated information system of Sapporo subway (삿포로 지하철 종합정보시스템에 관한 고찰)

  • Cho, B.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.237-239
    • /
    • 2004
  • Sapporo subway sets up the integrated information system to be aim at the effective and automatic work from the first time. They are expanding integrated system by introducing IT into Serve system positively which developed for recent several years. To keep up with the big size and high speed of information according to integrated system,. the integrated transmission line system which is basic of the integrated system is changed into the system which apply the newest technology. Also, they are aimed at the next generation traffic system through the cooperation of the local administration, for example, test of the multipurpose card using non-contact IC card. This study reviewed the present state of Sapporo subway, the upgrade of information transmission system, and the function of each serve system those are the order of equipment, management of the running, management of the disaster presentation, signal protection, passenger management etc.

  • PDF

Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques

  • Hassan Hosseini, Seyed Mohammad;Rezaei Baravati, Peyman
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1093-1101
    • /
    • 2015
  • Partial Discharge (PD) is a physical phenomenon, which causes defects and damages to the insulation. This phenomenon is regarded as the most important source of fault and defect in power transformers. Therefore, methods of high speed and precision are considered of special importance for the maintenance of transformers in localization of the origin of partial discharge. In this paper, the transformer winding is first modeled in a transient state by using RLC ladder network and multiconductor transmission line (MTL) models. The parameters of the two models were calculated by Ansoft Maxwell software, and the simulations were performed by Matlab software. Then, the PD pulses were applied to the models with different widths of pulses. With regard to the fact that the signals received after the application of PD had a variable frequency nature over time, and based on the wavelet transform and signal energy, a new method was presented for the localization of PD. Ultimately; the mentioned method was implemented on a 20 kV winding distribution transformer. Then, the performances of the models used in this paper, including RLC and MTL models, were compared in different frequency bands for the correct distinction of partial discharge location.

Pressure Control of Lockup Solenoid Valve for Automatic Transmission (자동변속기 록업솔레노이드밸브의 압력제어)

  • Park, Kwan-su-;Chung, Soon-Bae;Lee, Kyo-Il-
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.472-477
    • /
    • 1994
  • The lockup clutch is embeded on torque converter of automatic transmission to prevent the efficiency deterioration of torque converter in high speed. For improving fuel consumption rate, it is desirable to engage the lockup clutch earlier. But, it results in degrading shift quality, due to the transient torque. The transient clutch pressure which affects the shifting quality, should be controlled properly. In this study, to solve the problem, it is analysed the hydraulic circuit of lockup system including line pressure regulating circuit, established the nonlinear model, and designed the PID controller. The line pressure is supplied to the lockup clutch through the lockup control valve by switching the lockup solenoid valve on. In order to control the transient pressure actively, it is needed to control the lockup solenoid valve by closed loop control. The lockup solenoid valve is 2-way on-off valve, and is adequate for PWM control. To reduce the pressure chattering, the carrier frequency is increased. Target pressure profile is computed from optimized velocity difference profile throuth dynamic equation of vehicle system.

  • PDF

The Simulation of Transmission Line Fault-Induced Noise Signals. (선로고장시 발생되는 잡음의 시뮬레이션)

  • Shin, Myung-Chul;Kim, Mu-Woong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.454-456
    • /
    • 1987
  • A more specialized area of transient evaluations is transmission line fault-detecting and protection system. During the first cycle or two following a power system fault, a high-speed protective relay is expected to make a decision as to the severity or location of the fault, usually based on 60 Hz information, i.e. the phase and magnitude of 60 Hz voltage or current signals. It is precisely at this time however that the signal is badly corrupted by noise, in the form of a de offset or frequencies above 50 Hz. One of several possible sources of transients in protection measuring signals is in the primary system for which protection is required in its response to the impact of short circuit fault on-set. Other sources are in the primary voltage and current transducers from which protection signals are derived, and, often of particular importance, in the interface circuits between the transducer secondaries and the comparator and measuring elements of the protection system. However, the noise signals that will be described in this paper are due to the main power system only and do not include errors due to current or voltage transducers.

  • PDF

Minimization of Crosstalk by Optimum Synthesis of Profiles of Multiple Coupled Data Transmission Lines on Microstrip (다중결합된 마이크로스트립 데이터 전송로 자태의 최적합성을 통한 누화 최소화)

  • 박의준
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.12
    • /
    • pp.1-11
    • /
    • 1998
  • A line profile synthesis method is presented that minimizes the nearest-neighbor crosstalk peak level for high-speed pulse transmission in multi-coupled microstrip signal buses. We adopted the optimization technique for the reflected wave control on bus lines resulting in increasing the average spacing between strip conductors, since in a parallel-conductor bus the crosstalk energy is concentrated at the nearest neighbors of the driven line. The generalized S-matrix technique is applied for the input and output waveform prediction, and crosstalk characteristics of various nonuniform lines synthesized for increasing the average spacing are analyzed by comparing each other. Simulation results demonstrate that the Chebyshev taper with dips is adequate to significantly minimize the crosstalk peak level under the satisfactory waveform integrity since the profile is oriented to evenly reflect significant pulse spectra within the frequency range of pulse.

  • PDF

A Study on a Reduced Crosstalk for the Design of 100 MHz High Speed Data Transmission Modular Jack (Crosstalk를 방지한 100 MHz 고속 데이터 전송 Modular Jack의 설계 및 제작에 관한 연구)

  • 이중근;안현수
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 1999
  • In this paper, a method of canceling and suppressing differential-mode crosstalk-noise signals caused by non-uniform coupling between two transmission lines in UTP(Unshielded Twisted Paris) modular jacks is discussed. Differential-mode crosstalk-noise signals in balanced transmission lines in UTP modular jacks were suppressed by inserting auxiliary capacitance between balanced transmission line pairs which are located closely enough to be effectively coupled each other. To verify the effectiveness of the inserted capacitances, precisely calculated auxiliary capacitances were applied to 10 pin modular jacks which are used in local area networks at 100 Mb/s with unshielded twisted pair-cables. The NEXT(Near-End Crosstalk) losses were measured to prove its applicability.

  • PDF

Data Transmission through Power Line of Smart Transmitter

  • Kim, Jong-Hyun;Kang, Hyun-Kook;Seong, Poong-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.471-476
    • /
    • 1996
  • In this study, the method to use the phase shift keying (PSK) communication technique in smart transmitter is presented. In nuclear applications. smart transmitters for various parameters are expected to improve the accuracy of measurement and to reduce the load of calibration work. The capability of communication in field level is the most important merit of the smart transmitter. The most popular method is using of digital and analog techniques simultaneously - transmitting measurements from the field at 4∼20mA while modulating the current to carry digital information in both directions over the same twisted pairs. Conventional smart transmitters use the frequency shift keying (FSK) method for digital communication. Generally, however, the FSK method has the speed limit at 1200 bps. Amount of information to transmit becomes increasing as the processing technique is improved. The PSK method is noticeable alternative for high speed digital communication, but it has non-zero DC component. In order to use the PSK method in the field transmission with smart transmitter, the method to remove the DC component is studied in this work.

  • PDF

Transmission Line Parameter Extraction and Signal Integrity Verification of VLSI Interconnects Under Silicon Substrate Effect (실리콘 기판 효과를 고려한 VLSI 인터컨넥트의 전송선 파라미터 추출 및 시그널 인테그러티 검증)

  • 유한종;어영선
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.36C no.3
    • /
    • pp.26-34
    • /
    • 1999
  • A new silicon-based IC interconnect transmission line parameter extraction methodology is presented and experimentally examined. Unlike the PCB or MCM interconnects, a dominant energy propagation mode in the silicon-based IC interconnects is not quasi-TEM but slow wave mode(SWM). The transmission line parameters are extracted taking the silicon substrate effect (i.e., slow wave mode) into account. The capacitances are calculated considering silicon substrate surface as a ground. Whereas the inductances are calculated by using an effective dielectric constant. In order to verify the proposed method, test patterns were designed. Experimental data have agreement within 10%. Further, crosstalk noise simulation shows excellent agreements with the measurements which are performed with high-speed time domain measurement ( i.e., TDR/TDT measurements) for test pattern, while RC model or RLC model without silicon substrate effect show about 20~25% underestimation error.

  • PDF