• 제목/요약/키워드: High-Order Power Analysis

검색결과 989건 처리시간 0.042초

Uncertainty Modeling and Robust Control for LCL Resonant Inductive Power Transfer System

  • Dai, Xin;Zou, Yang;Sun, Yue
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.814-828
    • /
    • 2013
  • The LCL resonant inductive power transfer (IPT) system is increasingly used because of its harmonic filtering capabilities, high efficiency at light load, and unity power factor feature. However, the modeling and controller design of this system become extremely difficult because of parameter uncertainty, high-order property, and switching nonlinear property. This paper proposes a frequency and load uncertainty modeling method for the LCL resonant IPT system. By using the linear fractional transformation method, we detach the uncertain part from the system model. A robust control structure with weighting functions is introduced, and a control method using structured singular values is used to enhance the system performance of perturbation rejection and reference tracking. Analysis of the controller performance is provided. The simulation and experimental results verify the robust control method and analysis results. The control method not only guarantees system stability but also improves performance under perturbation.

초고속 자기부상열차를 위한 하이브리드형 부상 추진 시스템의 설계 및 특성해석 (Design and Characteristic Analysis of Hybrid-Type Levitation and Propulsion Device for High-Speed Maglev Vehicle)

  • 조한욱;김창현;한형석;이종민;김봉섭;김동성;이영신
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.715-721
    • /
    • 2010
  • This paper deals with the design and characteristic analysis of electro-magnet/permanent-magnet (EM-PM) hybrid levitation and propulsion device for high-speed magnetically levitated (maglev) vehicle. The machine requires PMs with high coercive force in order to levitate the vehicle by only PMs, and propulsion force is supplied by long-stator linear synchronous motor (LSM). The advantages of this configuration are an increasing levitation airgap length and decreasing total weight of the vehicle, because of the zero-power levitation control. Several design considerations such as machine structure, manufacturing, and control strategy are described. Moreover, the levitation and propulsion device for high-speed maglev vehicle has been designed and analyzed usign the electromagnetic circuit and FE analysis. In order to verify the design scheme and feasibility of maglev application, 3-DOF static force test set is implemented and tested. The obtained experimental data using the static tester shows the validity of the design and analysis approaches.

농형 유도발전기의 계통 연계시 전압 변동 및 전력 흐름 분석 (Analysis for Voltage Fluctuation and Power Flow at the Grid-Connected Time of Squirrel-Cage Induction Generator)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.45-51
    • /
    • 2014
  • Synchronous generators and induction generators are mainly used in hydroelectric power generation. Synchronous generator is mainly applied to large hydroelectric plants but induction generator is applied to the small hydro power plants. Stability of induction generator is slightly less than the synchronous generator. However, induction generator has many advantages rather than a synchronous generator in terms of price and maintenance. So Induction generator is used primarily in small hydroelectric power station less than 1,000kW recently. Squirrel cage induction generator generates a high inrush current at the grid-connection. This high inrush current causes a voltage drop on the grid. In order to reduce the voltage drop and to analyze the power flow, the analysis for operating characteristics of the induction generator should be reviewed in advance. In this study, we analyzed the voltage drop and power flow analysis when a 1500kW induction generator is connected to the grid. The voltage drop is slightly higher than the acceptable range of distributed power supply voltage and the power flow of the generator is performed well.

원전구조물의 고강도철근 적용을 위한 구조적 목표성능분석 (Analysis of the Structural Target Performance in order to Apply High-Strength Reinforcing Bars for the Nuclear Power Plant Structures)

  • 이병수;방창준;이한우;임상준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.195-196
    • /
    • 2012
  • Because of the high level of the safety and durability, a lot of reinforcing bars is placed in the concrete structure of the Nuclear Power Plant. But the overcrowding re-bars cause some problems during the construction as the diseconomy, construction delay, quality deterioration, and so on. These problems can be solved by applying the high-strength reinforcing bars to NPP structure. To achieve this, after analysing the structural target performance like the control of cracks, adherence, shear, torsion, development of reinforcement and earthquake-resistance, the results of the analysis will be reflected in the structural performance evaluation test.

  • PDF

Lateral Far-field Characteristics of Narrow-width 850 nm High Power GaAs/AlGaAs Laser Diodes

  • Yang, Jung-Tack;Kwak, Jung-Geun;Choi, An-Sik;Kim, Tae-Kyung;Choi, Woo-Young
    • Current Optics and Photonics
    • /
    • 제6권2호
    • /
    • pp.191-195
    • /
    • 2022
  • We investigate the lateral far-field pattern characteristics, including divergence angle change and far-field pattern analysis as output power increases, of narrow-emitter-width 850 nm GaAs/AlGaAs laser diodes (LDs). Each LD has a cavity of 1200 and 1500 ㎛ and narrow emitter width of 2.4 ㎛ for the top and 4.6 ㎛ for the bottom. The threshold currents are 35 and 40 mA, and L-I kinks appear at power levels of 326 and 403 mW, respectively. The divergence angle tends to increase due to the occurrence of first-order lateral mode and the thermal lensing effect. But with the L-I kink, the divergence angle decreases and the far-field pattern becomes asymmetric. This is due to coherent superposition between the fundamental and the first-order lateral mode. We provide detailed explanations for these observations based on high-power laser diode simulation results.

배전계통 PQM 시스템 구축 및 고조파전압 분석사례 (A Case of the Distribution Power System PQMS Construction & Harmonic Voltage Analysis)

  • 박용업;이건행
    • 조명전기설비학회논문지
    • /
    • 제24권9호
    • /
    • pp.108-117
    • /
    • 2010
  • The main contents of this paper are the PQM system construction case and distribution system harmonic voltage analysis. The PQM system has constructed by KEPCO in order to investigate power quality of distribution power system for new power quality standard of KEPCO. In result, we have confirmed that voltage harmonic measurement value of the high voltage contract customer 8 households is suitable the KEPCO harmonic standard tentative plan. And the voltage harmonic value of distribution line end side is not always more high than source side by harmonic current offset effect. In the future, acquired data by season, region, load from the PQMS will be used on the resonable harmonic standard enactment in KEPCO.

동력분산형 고속전철의 추진시스템용 냉각장치의 설계 연구 (Study on Design of the Cooling System Used for the Propulsion System of the High-Speed EMU)

  • 유성열;김성대;기재형;임광빈;김철주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1221-1226
    • /
    • 2008
  • Present, the cooling method of using a phase-change heat transfer such as immersed type, heat pipe etc is applied in cooling of high-capacity power semiconductors of the main power system for the high speed train with the concentrated traction. In order to apply these phase-change cooling system to the high speed EMU to be developed, needed are technological researches of consideration of installing space, air passage, light weight material and miniaturization. Although this research establishes design specifications through theoretical analysis and computational analysis from the basic design process of the cooling system of the propulsion system for the high-speed EMU, when details design is completed, present improvement subject and optimum design before manufacturing the prototype of the cooling system on the basis of analysis results. And then, carried out will be the performance tests through prototype manufacture and reliability estimation by components of cooling system.

  • PDF

Two Phase Interleaved LLC 공진 컨버터 (Two Phase Interleaved LLC Resonant Converter)

  • 김주훈;이광호;김은수;이재삼;이현관;정용채
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.397-405
    • /
    • 2009
  • 최근 대화면 및 슬림화를 위한 LCD TV의 전원장치는 고집적화와 고효율에 대한 연구가 이슈가 되고 있고, 이를 위해 Multi-phase LLC 공진컨버터가 연구되고 있으며 본 논문에서는 제어회로를 간단화 하면서 300W Two Phase Interleaved LLC 공진컨버터를 제안 적용한 실험결과에 대하여 서술하였다.

발전플랜트의 전력변환기 고장사례 분석 (An analysis about failures of the power converter in power plant)

  • 한석우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.554-555
    • /
    • 2012
  • The failures in the power plant can lead to a dangerous situation according to the demand and supply of the electric power. The failure times of the domestic plant happens very often, and it has been reported as a significant loss by the power sales. Therefore, the power plant is demanded to maintain very well in order to produce a high quality of power. The rate of failures by the electricity facility is filled with 40[%] among the trouble in the failures of the power plant. The failures of power plant can cause serious accidents, magnificent losses, and chaos in our society. So, we require a significant plan to reduce such a serious problem. In this paper, I analysis the failure case of power converter in power plant, and I offer the better solution to be able to prevent the failures from power plant.

  • PDF

광대역 설비용 전원선 EMI 필터의 설계 (Design of Wideband Facility Power-line EMI filter)

  • 정세교;임정규;김무현;강병극
    • 전력전자학회논문지
    • /
    • 제14권6호
    • /
    • pp.440-448
    • /
    • 2009
  • 설비용 전원선 EMI 필터(Facility power-line EMI filter)는 컴퓨터 센터와 같이 전자기적인 노이즈에 민감한 장비를 가진 배전 설비로 유입되는 EMI를 차단하기 위해 사용된다. 따라서 전류용량이 크며 특정한 응용분야에서는 MIL-STD 220 기준으로 14kHz~10GHz의 광대역에서 최고 100dB 이상의 삽입 손실(Insertion loss)이 요구된다. 이러한 요구조건을 만족하기 위해서는 광대역의 주파수에서 커패시터, 인덕터 등의 특성 분석과 고차 LC 필터 (High order LC filter) 설계기술이 필요하다. 본 논문에서는 이러한 광대역 설비용 전원선 EMI 필터의 설계에 대하여 기술하였다. 먼저, EMI 필터 설계를 위한 필터의 특징과 구조, 필터의 설계 과정, 필터 설계 방법 등에 대한 연구를 수행하였다. 그리고 필터 구성의 기본 소자인 커패시터와 인덕터의 특성에 대해 분석하였다. 최종적으로 광대역 설비용 전원선 EMI 필터를 설계 및 제작하여 실험을 수행하였으며, 실험 결과의 비교 분석을 통해 연구 결과를 검증하였다.