• Title/Summary/Keyword: High-Efficiency Appliances

Search Result 69, Processing Time 0.026 seconds

Characteristics Analysis of Single Phase Induction Motor via Equivalent Circuit Method and Considering Saturation Factor

  • Cho, Su-Yeon;Kim, Won-Ho;Jin, Chang-Sung;Kang, Dong-Woo;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.178-183
    • /
    • 2014
  • This paper presents a motor characteristics analysis method using an equivalent circuit. Motor characteristics analysis via equivalent circuit is very important for designing a high efficiency single phase induction motor. The accuracy of the motor characteristics depends on the accuracy of the parameters, especially saturation factor, which determines the cyclical relationship in the analysis process. Therefore, using the proposed method, the saturation factor was calculated using the iteration routine and numerical technique. The proposed method was verified by comparing the finite element method results and the dynamo test results of manufactured prototype model.

Self-Excited Buck-Boost DC-DC Converter (자려식 승강압형 DC-DC 컨버터)

  • Lee, Seong-Gil;An, Tae-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.11
    • /
    • pp.663-669
    • /
    • 1999
  • This paper presents new self excited DC-DC converters such as Buck-boost type, Buck type and also non-inverting Buck-boost type. The proposed converters has the following advantages: simple topology, small number of circuit components, easy control method. Therefore, these converters are suitable for the portable appliances with battery source. It is especially suited for low power DC-DC conversion applications where non isolation output power is usually required. The steady state characteristics of proposed self exciting Buck-boost DC-DC converter are analysis and the result shows good agreement with experimental value. Furthermore the experimental results for 50W class self oscillating Buck-boost DC-DC converter have been obtained, which demonstrate the high efficiency and good performance.

  • PDF

Comparative Luminance and Correlated Color Temperature of Work-place by a Fluorescent and LED Light Sources (LED광원과 형광광원에 의한 작업면의 휘도 및 색온도 비교)

  • Baik, Seung heon;Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.21-26
    • /
    • 2008
  • According to the tendency of energy efficiency and environment-friendly chracteristics, demend of High-efficiency lighting using LED(Light Emitting Diode)are being increased actively and applied in various fields. However, In order to adequate application of LED light sources, it is necessary to lighting environment and luminous characteristics of LED light sources. This Study aims to characterize the work-plane lighting environment by LED light sources comparing with fluorescent light sources which are widely used. For the sake of this study, a fluorescent light source and 5 LED light sources were introduced and luminance and correlated color temperature were measured to evaluate luminance contrast. The experimental model is Mock-up which is $4.9m{\times}7.2m$ with a height of 2.9m. The test room was set up partition and desks. Luminance and correlated color temperature were measured work-plane on the desk which was set up local lighting by the Radiant Imaging ProMetric 1400. The optical characteristics data of LED can give a lot of advantages to design LED lighting appliances. Hereafter, the object of research will be conducted to evaluate effects of LED light sources on working performance, survey of visual performance, preference and physiology of subjects.

A systematic review of the accuracy and efficiency of dental movements with Invisalign®

  • Galan-Lopez, Lidia;Barcia-Gonzalez, Jorge;Plasencia, Eliseo
    • The korean journal of orthodontics
    • /
    • v.49 no.3
    • /
    • pp.140-149
    • /
    • 2019
  • We are currently living in an era where the use of computer-aided design/computer-aided manufacturing has allowed individualized orthodontic treatments, but has also incorporated enhanced digitalized technology that does not permit improvisation. The purpose of this systematic review was to analyze publications that assessed the accuracy and efficiency of the $Invisalign^{(R)}$ system. A systematic review was performed using a search strategy to identify articles that referenced $Invisalign^{(R)}$, which were published between August 2007 and August 2017, and listed in the following databases: MEDLINE, Embase, Cochrane Library, Web of Knowledge, Google Scholar, and LILACS. Additionally, a manual search of clinical trials was performed in scientific journals and other databases. To rate the methodological quality of the articles, a grading system described by the Swedish Council on Technology Assessment in Health Care was used, in combination with the Cochrane tool for risk of bias assessment. We selected 20 articles that met the inclusion criteria and excluded 5 due to excess biases. The level of evidence was high. Although it is possible to treat malocclusions with plastic systems, the results are not as accurate as those achieved by treatment with fixed appliances.

Combined treatment with headgear and the Frog appliance for maxillary molar distalization: a randomized controlled trial

  • Burhan, Ahmad Sharafeddin
    • The korean journal of orthodontics
    • /
    • v.43 no.2
    • /
    • pp.101-109
    • /
    • 2013
  • Objective: To evaluate the efficiency of the Frog appliance (FA) alone or in combination with headgear for distalizing the maxillary molars. Methods: Fifty patients (25 males and 25 females) aged 12.6 - 16.7 years who received treatment for Class II malocclusion at the Orthodontic Clinic of Al-Baath University were selected for this study and randomly divided into 2 equal groups. Maxillary molar distalization was achieved using the FA alone (group 1) or a combination of the FA with high-pull headgear worn at night (group 2). Lateral cephalograms were obtained before and after treatment. Results: The maxillary molars moved distally by 5.51 and 5.93 mm in groups 1 and 2, respectively. Distal movements were associated with axial tipping by $4.96^{\circ}$ and $1.25^{\circ}$, and with loss of anchorage by mesial movement of the second maxillary premolars by 2.70 and 0.90 mm in groups 1 and 2, respectively. The combined use of the FA and nighttime high-pull headgear decreased the distalization time and improved the ratio of maxillary molar distalization movement relative to the overall opening space between the first maxillary molars and second premolars. Conclusions: The FA can effectively distalize the maxillary molars, this distalization associates with some unfavorable changes. Nighttime use of high-pull headgear combined with the FA can reduce these unfavorable changes and improve treatment outcomes.

Performance Estimation of Cross-Flow Fan by Numerical Method (수치해석적 기법을 이용한 횡류홴 성능 평가)

  • Kim, D.-W.;Lee, J.-H.;Park, S.-K.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.152-157
    • /
    • 2002
  • A cross-flow fan is widely used on many industrial fields: a blower for the general industry, mining industry, automobile and home appliances. The design point of the cross-flow fan is generally chosen by based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the low flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for cross-flow fan including the impeller, the rearguider and the stabilizer. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, SIMPLE algorithm, sliding grid system and standard k-$\epsilon$ turbulence model.

  • PDF

Analysis of Performance of Cross-Flow Fan with Various Rear Guiders (리어가이더 형상변화에 따른 횡류홴 성능해석)

  • Kim, Dong-Won;Lee, Jun-Hwan;Park, Seong-Gwan;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

A Preference and Satisfaction Survey on the Wound Management System (창상 치료 시스템에 대한 선호도 및 만족도 조사)

  • Kang, Yoon Kyeong;Hong, Aram;Lee, Boung Chul;Kim, Dohern;Seo, Cheong Hoon
    • Journal of the Korean Burn Society
    • /
    • v.16 no.2
    • /
    • pp.99-103
    • /
    • 2013
  • Purpose: The biggest problem of wound healing is a possible occurrence of lesion. Especially, in the case of patients who have a skin injury around exposed body parts, if their treatment period drag on for long time, they can suffer from aftereffects and the costs can be passed on to a society. Therefore, in this research, we investigated the need to develop the effective medicine and appliances for the patients by examining which therapy methods are being applying to the skin damage and what is the advantage and limit by evaluating the patient's satisfaction level. Methods: We carried out an online and offline survey targeting medical teams in order to analyze device for wound care. A total of 125 medical teams applied to the research, and investigate the level of customer satisfaction. Results: The moist dressings are the most used method for wound healing. When it comes to the level of customer satisfaction, biological dressing product also has a high satisfaction level. However its high cost tends to limit the use. Conclusion: This research reached a conclusion that it is need to develop a low cost and high efficiency wound care product considering the fact that its high cost and low efficiency induced economic problems. Generally, it is needed to develop a product for skin regeneration based on biological technologies, not a product just for damage cure.

A SRM driving with voltage and switching angle for maximum torque/efficiency and minimum torque ripple (최대 토크/효율 및 최소 토크맥동을 위한 스위칭각/전압에 의한 SRM 운전)

  • 차현록;김현덕;김광현;임영철;장도현
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.309-317
    • /
    • 2000
  • This paper presents the switching angle and voltage to maximize torque/efficiency and minimize torque ripple in the 4-phase 6-poles Switched Reluctance Motor(SRM). SRM drive has high saturation and nonlinear characteristics of inductance. So we cannot hard to find optimal condition by using analytic method. Therefore it is hard to find the operating the switching angle and voltage through the approximated analysis and computer simulation by using SIMULINK according to the speed and torque required by load. From the results, we can say that the optimum average voltage is determined by the load only and the speed is determined by the optimum turn-on/off angle only. And the maximum efficiency and minimum torque ripple depend on switching angle, not on voltage. And then one-chip microcontroller controls the switching angle and voltage of an asymmetrical inverter in the SRM driver. This drive method, which is expect that the driving methods, which are maximizing torque/efficiency and minimizing torque ripple, will be suitable for the electric vehicle, the industrial application and household appliances.

  • PDF

Scientists preference on spectrophotometer control display design (과학자들이 선호하는 분광광도계 컨트롤 디스플레이 디자인 연구)

  • Jeong, Sang-Hoon;Jeong, Seong-Won
    • Science of Emotion and Sensibility
    • /
    • v.12 no.4
    • /
    • pp.511-518
    • /
    • 2009
  • With the help of the advancements in information and communication, information appliances are changing. Flat panels made it possible for information appliances to become smaller in size and lighter in weight, and high end graphics provide increase in realistic and immersive use. Even with these advancements interest in design for laboratory equipment tend to only stay on a level of the exterior of the equipment, not to the point of designing the interface of display GUI. Inspired with the problem above this research would contain the preference analysis ondisplay GUI design considering the characteristics of the main users and the laboratory equipment itself. The test would be held through comparison of graphic-based display GUI and text-based display GUI and analyzing the task time and number of errors made, looking for which display GUI scientist prefer. The test results show that text-based GUI has a higher efficiency but the actual users preferred the graphic-based display GUI.

  • PDF