공장창호의 환기특성에 관한 연구 (A Study on Ventilation Characteristics of Industrial Windows)

  • 박승욱;김태형;하현철;허영빈
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.581-587
    • /
    • 2011
  • Industrial natural ventilation systems consist of gravity ventilator, the high/low windows and doors. Especially, the high windows play an important role in the industrial natural ventilation systems. Generally speaking, industrial high windows are divided into 3 types; louver type, $45^{\circ}$ open type and $90^{\circ}$ open type. This study was numerically and experimentally conducted. Three types of windows were tested to know the ventilation characteristics and estimate the ventilation efficiencies. Numerically, computational fluid dynamics software (AIR PAK Ver. 2.0) was used to observe the flow characteristics inside the industrial building and the concentration contours generated by the tracer gas method. Experimentally, the flow visualization technique and the tracer gas method were applied with the model building to characterize the flow pattern inside the model building and to estimate the ventilation efficiencies with the different windows. It was found that $90^{\circ}$ open type window was most effective for the discharge of pollutants from the industrial building. On the other hand, the louver type window was found to be less effective than any other windows.

자연환기용 공장창호의 빗물유입 저감대책에 관한 실험적 연구 (Experimental study on reduction in rain water penetration through industrial windows used for natural ventilation)

  • 박승욱;김태형;하현철;허영빈
    • 한국산업보건학회지
    • /
    • 제20권3호
    • /
    • pp.175-183
    • /
    • 2010
  • Windows are widely used for natural ventilation of the various buildings. Especially high level windows as a part of industrial ventilation systems, play a crucial role in natural ventilation. Compared to mechanical ventilation system, natural ventilation has the advantage of lower installation and operating costs. In general, high level windows for industrial buildings have three types; louver type, 45$^{\circ}$ open type and 90$^{\circ}$ open type. Based on previous studies, it was found that the louver type and 45$^{\circ}$ open type are very effective in reducing rainwater penetration, but they did not have enough ventilation efficiencies. Preliminary tests were performed with the various types of windows. It was found that a 90$^{\circ}$ open double layer type window was the best among those which tested in our preliminary tests. Simulated rain was used to estimate the amount of rain penetrated through windows and to observe the paths of rain penetration. Various 90$^{\circ}$ open windows were tested to find the windows with minimum rain penetration and maximum ventilation efficiency.

높은 집적도를 가지는 Windows XP PC 클러스터 구축 (Construction of Highly Integrated PC Cluster based on Windows XP)

  • 이성기;신재렬;최정열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 춘계 학술대회논문집
    • /
    • pp.41-46
    • /
    • 2005
  • A new PC cluster was designed and constructed based on Windows XP Operating system. Primary target of the present design was the high node density per rack by using the general PC parts those are cost-effective and readily available in the market. Other major design points were system cooling and the convenient maintenance using standard PC parts. Presently 24 nodes per rack seems to be optimum considering the specification of the network switching device, system cooling and power supply, but 40 nodes can be accommodated within a single rack at maximum. Windows XP was selected as a high-performance computing environment considering the cost and the convenience in acquisition, maintenance and education. Both fast-Ethernet and Gigabit Ethernet network connection were tested and compared with previous data, especially for Linux doter using Myrinet. The result shows that there is no significant difference between the operating systems and the Fast-Ethernet and/or Gigabit Ethernet are good solution for the high-performance PC cluster considering the cost and performance.

  • PDF

시뮬레이션과 실증실험을 통한 슈퍼윈도우의 성능분석 (Analysis Performance of Super Window through Simulation and Verification Experiment)

  • 백상훈;이진성;조수;장철용;성욱주;서승직
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1069-1074
    • /
    • 2006
  • Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.

  • PDF

난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가 (Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis)

  • 장철용;김정국;안병립;김준섭;한찬훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

Study on Property of Diamond Mobile Telephone Windows

  • Lin, Liu-Tie;Sheng, Yang-Guang;Wu, Zhou-Jian;Ning, Sun-Yi
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권2호
    • /
    • pp.105-107
    • /
    • 2002
  • a-C:H films were coated on windows of mobile telephone by RF plasma chemical vapor deposition equipment made in our company. Thickness of the coatings is about 0.7 micrometers and they have high hardness, low friction coefficient, good adhesion, high optical transparency and chemical inertness. Knoop hardness of the diamond-like carbon films on glass substrate is 2328 kg/mm$^2$. The adherence between films and substrate is good and shows to be 69 N by scratching test. The optical performance is improved obviously owing to coat the film on it. The index of the coated windows is 2.5, transmission of visible light is larger than 90%, and transmission of ultraviolet light decreases by 30% and the ultraviolet light can be obstructed obviously. The coated glass also has self-clean effect and decontamination ability. The films have hydrophobic character and the soakage angle of water drop is larger than 90 degrees. The windows have fog-proof ability owing to eliminate the capillary phenomena in the inner surface. The physics and chemical properties of the coated windows are steady. Study indicates that the performance of a-C:H coated mobile phone windows are improved notably on wear-resistance, corrosion-proof and optical properties and it is excellent mobile windows protective coatings.

  • PDF

확장형 발코니 공동주택의 창호종류에 따른 결로 및 온열환경에 관한 연구 (A Study on the Condensation and Thermal Environment according to Window Systems Types Installed for a Extended-Balcony Apartment)

  • 윤종호;안영섭;김병수
    • KIEAE Journal
    • /
    • 제7권5호
    • /
    • pp.87-92
    • /
    • 2007
  • As expansion of balconies at apartments has been legalized, the major function of the balconies as a thermal buffer zone is disappearing. This weakens the ability of window to insulate heat and multiplies surface condensation. Thus more and more residents require solutions to increasing surface condensation and aggravation in thermal comfort. This study intends to provide basic data by evaluating performance of triple layered Low-E windows, triple layered clear windows, double layered Low-E windows and double layered clear window used for expanded balconies and marketed within the country in terms of surface condensation and thermal environment through simulation. Results revealed that no surface condensation occurred at double layered Low-E windows and triple layered Low-E windows. Surface condensation took place at double layered clear windows and triple layered clear windows at a relative humidity of 60%. Thermal environment analysis suggested that double layered clear windows showed the most time falling into the range of comfort at $23^{\circ}C$. The figure were $22^{\circ}C$ for triple layered clear windows, $22^{\circ}C$ for double layered Low-E windows and $21^{\circ}C$ for triple layered Low-E windows.

고효율 로이유리 창호의 정량적 단열성능 평가 (An Evaluation for the Quantitative Thermal Performance of High Energy Efficiency Low-e Window)

  • 최경석;최현중;강재식;양관섭;이숭언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.970-975
    • /
    • 2006
  • In the high oil prices age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating large percentage whole building loads, and are regarding as the primary target of energy efficiency. The purpose of this study is to draw up a technical counterplan for the intensification of windows energy efficiency and spread promotion by quantitative thermal performance with KS test method for a comparison between the general Pair glass windows and the Low-e pair glass windows.

  • PDF

컴퓨터 그래픽스 기법을 이용한 초고층 강제어초에 관한 연구(I) - 설계지원 프로그램 개발 (A Study on Very High-rise Steel Artificial Reefs Based on Computer Graphics - part I (Design Aided Program Development))

  • 신현경;박호균
    • 대한조선학회논문집
    • /
    • 제36권1호
    • /
    • pp.99-108
    • /
    • 1999
  • 초고층강제어초(VEry High-rise Steel Artificial Reef, VEHSAR)의 형상 표현과 해석을 위해서 3차원 모델링 프로그램을 Windows 95(또는 Windows NT) 환경하에서 MFC(Microsoft Foundation Class)를 기반으로 한 Visual C++로 개발하였다. 컴퓨터를 통해 미리 초고층 강제어초 건조를 실제와 같이 구현해 봄으로써 문제점의 사전 예측 및 대책 수립 등을 가능케 하는 저비용 고효율의 일관설계시스템을 구축하는 것을 목표로 하는 이 프로그램은 객체지향프로그램 기법과 CAD/CAM기술의 도입으로 생산성 향상이 기대되며, OpenGL이라는 그래픽 라이브러리를 도입하여 좀더 빠른 고화질의 3차원 그래픽을 화면상에 나타나게 할 수 있다.

  • PDF

초고층 공동주택의 이중외피 창호 유형별 실내기류 특성 비교 (Indoor Airflow of High-Rise Apartment with Different Types of Box-Windows)

  • 최태환;전미숙;이정현;김태연;이승복
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.993-998
    • /
    • 2006
  • High-rise apartments have a problem using natural ventilation because of the strong outdoor wind velocity. Conventional high-rise apartments have adopted mechanical ventilation systems to maintain the indoor air quality. However, it leads to the overuse of electricity and the sick house syndrome. Double-skin facade is the alternative for the high-rise building to use natural ventilation and this study is focused on the performance of the box-window, which is a kind of double-skin facades. Indoor wind velocity and HCHO concentrations are analyzed with three types of box-windows: the diagonal type, parallel type and perpendicular type. The airflow is simulated by computational fluid dynamics program. Box-windows reduce the maximum value of indoor wind velocity about 50% compared with the single window and the HCHO concentrations do not have the big difference. Box-windows could be the alternative to enhance the use of the natural ventilation and indoor air quality of the high-rise apartment.

  • PDF