• Title/Summary/Keyword: High voltage electrical burn

Search Result 16, Processing Time 0.025 seconds

Peroneal Artery Perforator Free Flap on the Palm and Removal of Back Foreign Body in High Voltage Electrical Burn Patient: A Case Report (고압전기화상 환자에서 손바닥에 비골동맥천공지유리피판수술과 등의 이물질제거수술: 증례 보고)

  • Jung, Sung Won;Lee, Seung Je
    • Journal of the Korean Burn Society
    • /
    • v.22 no.2
    • /
    • pp.58-65
    • /
    • 2019
  • Wound caused by high-tension electrical burns is difficult to manage because the wound is deep and complex. The wound is progressively necrotic due to microvascular injury resulting in deep tissue exposure. So, coverage of the wound at the entry point and the exit point is cumbersome, often requiring flap coverage. We experienced a case of one patient for peroneal artery perforator free flap coverage on the palm of the right hand of the entry point of electrical burn. The left foot wound of electrical exit point was covered by full thickness skin graft. Also a small wound was on the left side of the lower back was the exit point of electrical burn. The lower back wound was healed and recurred repeatedly after burn. On postburn day 6 month, through the radiologic exam, metal shadow was identified in the left gluteus muscle forming chronic sinus. We explored the wound of sinus and a foreign body was identified in the sac as multi braid wires thin as hair. According to the patient's past history, we suspected that the back wound was caused by electrical burn injury through the wires.

Chronic Osteomyelitis of Cranial Bones in a Patient with High-Voltage Electrical Burn on the Scalp: A Case Report (두피의 고압전기화상 환자에서의 두개골 만성골수염: 증례보고)

  • Jung, Sung Won;Choi, Joo Heon;Yoo, Kyung-Tak;Lim, Changsoo
    • Journal of the Korean Burn Society
    • /
    • v.24 no.2
    • /
    • pp.53-59
    • /
    • 2021
  • High-voltage electrical burn injuries on the scalp often result in scalp and cranial bone necrosis. Repetitive debridements and rich-vascularized flap coverage of the cranium are required. However, despite successful flap coverage, chronic osteomyelitis of cranial bones may occur. Treatment of chronic osteomyelitis of cranial bones is surgical debridement of the necrotic bone with re-coverage by a well-vascularized flap. The latissimus dorsi musculocutaneous flap is suitable not only for coverage of the cranium after the burn injury, but also for treatment of chronic osteomyelitis of the skull.

Reconstruction of Hand Defects with Forearm Flaps in Electrical Burn Patients (전기화상 환자에서 전완부피판을 이용한 수부의 재건)

  • Kim, Ki-Seon;Song, Hong-Shick;Na, Min-Wha;Lee, Tae-Seop;Lee, Dong-Eun
    • Archives of Reconstructive Microsurgery
    • /
    • v.10 no.1
    • /
    • pp.55-59
    • /
    • 2001
  • The hand is a frequently affected area in high voltage electrical burn injury as an input or output sites. Therefore, early debridement and synchronous flap coverage are generally accepted as a primary treatment of several electrical burns complicated by exposure of tendons, neurovascular structures, and bones. So, in order to establish convenient, promising methods for the reconstruction of hand defects in electrical burn patients, we performed various reverse forearm flaps. From March 1997 to February 2000, we reconstructed 12 cases of hand defects in high voltage electrical burn wounds with reverse forearm flaps. Reverse radial fasciocutaneous flap were 3 cases, reverse ulnar fasciocutaneous flap were 3 cases, reverse ulnar fasciocutaneous flap and STSG were 4 cases, reverse ulnar fascial flap and STSG were 2 cases. We successfully reconstructed hand defects in all 12 cases, and obtained following conclusions. 1 Various reverse forearm flaps provide well vascularized, profitable tissues and they require short operative time with relatively easy procedures. 2. Reverse fascial flap and STSG, reverse fasciocutaneous flap and STSG provide thin flaps with good aesthetics and minor donor site morbidity.

  • PDF

Reconstruction of Hand Using Peroneal Perforator Free Flap in High-Voltage Electrical Burn Patients (고압 전기화상에 의한 수부 손상 시 비골동맥 천공지 유리피판술을 이용한 재건)

  • Kim, Dong Hoon;Yoo, Jung Seok;Lim, Jun Kyu;Lee, Dong Lark
    • Archives of Plastic Surgery
    • /
    • v.35 no.1
    • /
    • pp.67-72
    • /
    • 2008
  • Purpose: The hand is frequently affected area in high voltage electrical burn injury as an input or output sites. Electrical burn affecting the hand may produce full thickness necrosis of the skin and damage deep structures beneath the eschar, affecting the tendon, nerve, vessel, even bone which result in serious dysfunction of the hand. As promising methods for the reconstruction of the hand defects in electrical burn patients, we have used the peroneal perforator free flaps. Methods: From March 2005 to June 2006, we applied peroneal perforator free flap to five patients with high tension electrical burn in the hand. Vascular pedicle ranged from 4cm to 5cm and flap size was from $4{\times}2.5cm$ to $7{\times}4cm$. Donor site was closed primarily.Results: All flaps survived completely. There was no need to sacrifice any main artery in the lower leg, and there was minimal morbidity at donor site. During the follow-ups, we got satisfactory results both in hand function and in aesthetic aspects.Conclusion: The peroneal perforator flap is a very thin, pliable flap with minimal donor site morbidity and is suitable for the reconstruction of small and medium sized wound defect, especially hand with electrical burn injury.

Free Vascularized Scapular and Parascapular Combined Flap Coverage for Extensive Soft Tissue Injury of the Extremity (견갑 및 부견갑 병합 유리피판에 의한 광범위한 사지 연부 조직 결손의 수복)

  • Choi, Soo-Joong;Chang, Kee-Young;Lee, Chang-Ju
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.2
    • /
    • pp.144-151
    • /
    • 2005
  • Purpose: Disaster as traffic accident, industrial disaster, high voltage electrical bum and flame burn of extremity have a destructive effect because of the involvement of deep structure. Generally, such injury may result in decreased function or loss of limb. In this study the successful use of the combined scapular/parascapular flap as microsurgical transfer to cover extensive defect of electrical and flame bum is reported. Material and Method: Between January 2000 and June 2001, the combined scapular and parascapular flap was used for the coverage of soft tissue defect for 7 patients were admitted to our department with high voltage electrical bum and flame burn. The recipient site were the wrist joint in 2 cases, the forearm in 1 case, the ankle joint in 1 case, the foot dorsum in 1 case, the heel in 1 case. Result: Flap survival was complete in all patients. The result of flap coverage for these deep wound was successful. Conclusion: The advantages of scapular/parascapular combined flap were coverage of the large defect, easy shaping of the flap to fit the required three dimensional configuration around the joint, non hair bearing skin of uniform thickness, minimal donor site morbidity.

  • PDF

Driving Method of Ultraviolet Sensor for Fire alarms using Pulse Width Modulation (PWM을 이용한 화재 감지를 위한 자외선 센서의 구동 방법)

  • Lim, Byung-Hyun;Ko, Nak-Yong;Hwang, Jong-Sun;Kim, Yeong-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05c
    • /
    • pp.31-35
    • /
    • 2004
  • We propose driving method of Ultraviolet sensor for fire alarms using pulse width modulation that used to fire detector with sensor of private-use detectable light energy as ultraviolet in energy of electromagnetic-wave type radiate from flame, when combustible burn with contain carbon,. Ultraviolet sensor is UV Tron using gas multiplication effect to current discharge and photoelectric effect of metal. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research designed driving circuit with UV sensors and proposed method of false alarm reduced to resemble fire. the result propers the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

Circuit Design of Ultraviolet Flame-Sensor for Fire-Fighting Appliances (자외선 센서를 이용한 화재감지기 응용 회로 설계)

  • Kim, Yeong-Min;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we proposed that when combustible burn with ultraviolet radiation, introduce fire detector with sensor of private-use detectable light energy as ultraviolet in energy of electromagnetic-wave type radiate from flame. This research using ultraviolet flame sensor is pyro-electric ultraviolet sensor based black body radiation theory. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV flame detector and proposed method of false alarm reduced to resemble fire. the result proposed the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

Expediting venous drainage in large anterolateral thigh flaps for scalp electrical burns in India: two case reports on the use of primary vein grafts for second vein anastomosis

  • Jyotica Jagadish Chawaria;Parvati Ravula;Nazia Tabassum;Srikanth Rangachari
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.404-410
    • /
    • 2023
  • Large scalp defects resulting from high-voltage electrical burns require free flaps, preferably skin, to permit optimal coverage and enable future or simultaneous cranial vault reconstruction. The anterolateral thigh permits the harvest of a large area of skin supplied by a reliable perforator. The superficial temporal vessels offer the proximate choice of recipient vessels to enable adequate reach and coverage. The lack of a second vein at this site implies the inability to perform a second venous anastomosis; however, this obstacle can be overcome by using an interposition vein graft, to the neck veins primarily. This assures adequate venous drainage and complete flap survival.

A Study on the Fundamental Characteristics of Self-healing Metalized Polypropylene Films (금속증착 Polypropylene Film의 Self-healing 기초특성 연구)

  • Choi, Ki-Suck;Ryu, Sung-Sic;Jung, Jong-Wook;Park, Ha-Yong;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2389-2391
    • /
    • 1999
  • This paper describes the self-healing characteristics which plays an important role in high voltage capacitors. In this experiment, artificial voids were simulated in MPPFs, and the self-healing voltages were measured by varying the diameter of the voids and the thickness of the MPPFs. As a result, the self-healing voltage and the burn-out area were increased with the increment in the void diameter and the thickness of MPPF.

  • PDF

Reconstruction of Electrical Burned Hand by Posterior Tibial Arterial Free Flap (후경골 동맥 유리 피판에 의한 수부 전기 화상의 재건)

  • Choi, Soo-Joong;Seo, Eun Min;Lee, Chang Ju;Chang, Jun Dong;Kim, Suk Wu;Lee, Sang Hun;Lee, Dong Hun;Seo, Young jin
    • Archives of Reconstructive Microsurgery
    • /
    • v.13 no.1
    • /
    • pp.14-23
    • /
    • 2004
  • Introduction: The hand and wrist are particularly susceptible to electrical burn. Skin defect with damage or exposure of underlying vital structure requires coverage by skin flap especially in case of the need for late reconstruction. We are reporting 4 cases of electrical burned hand treated by posterior tibial arterial free flap. The commonly used skin flaps such as scapular flap or groin flap are too bulky so that they are not satisfactory in function and cosmetic appearance. So we tried to cover them with a more thin skin flap. Materials and Method: From January 2002 to June 2003, four cases of hand and wrist electrical burn were covered using posterior tibial arterial free flap. All the cases were due to high voltage electrical burn. Age ranged from 31 years to 38 years old and all the cases were male patients. Recipient sites were 2 wrist, one thenar area and one knuckle of 2.3rd MP joint. Additional procedures were flexor tenolysis (simultaneous), FPL tenolysis and digital nerve graft (later) and extensor tendon reconstruction (later). Result: All the flap have survived totally without any complication including circulatory concern about the donar foot. Posterior tibail arterial free flap was so thin that debulking procedure was not required. Conclusion: For skin coverage of the hand & wrist region, posterior tibial arterial free flap have many advantages such as reliable anatomy, easy dissection and easy anastmosis with radial or ulnar artery and possibility of sensory flap. The most helpful advantage for hand coverage is its thinness. So we think this flap is one of the very useful armamentarium for reconstructive hand surgery.

  • PDF