• 제목/요약/키워드: High speed fan

검색결과 119건 처리시간 0.03초

다채널 액상 미세 추출 시스템 설계 및 제작 (Multichannel Liquid Phase Microextraction System)

  • 장신걸;정석;박상범
    • 한국기계가공학회지
    • /
    • 제19권10호
    • /
    • pp.1-7
    • /
    • 2020
  • In this study, a multichannel gas-liquid microextraction system is designed by integrating the automatic elution of extraction line and multichannel gas-purging liquid phase microextraction. The system uses an injection pump and inert gas to push the extraction solvent to a sample bottle of a gas-phase color autosampler and then implements multichannel gas-liquid microextraction and gas chromatography-mass spectrometry. The system also employs a three-way integrated micro-high-temperature heater, syringe pump, and microflow controller to realize the simultaneous processing of multiple groups of samples, thus improving the sample pretreatment speed and reproducibility and reducing human error. Autoinjection experiments were implemented with polycyclic aromatic hydrocarbon standard samples. The experiments show that the average recovery rate of the system exceeds 70%, and the relative standard among the channels is less than 15%.

Energy and Air Quality Benefits of DCV with Wireless Sensor Network in Underground Parking Lots

  • Cho, Hong-Jae;Jeong, Jae-Weon
    • 국제초고층학회논문집
    • /
    • 제3권2호
    • /
    • pp.155-165
    • /
    • 2014
  • This study measured and compared the variation of ventilation rate and fan energy consumption according to various control strategies after installing wireless sensor-based pilot ventilation system in order to verify the applicability of demand-controlled ventilation (DCV) strategy that was efficient ventilation control strategy for underground parking lot. The underground parking lot pilot ventilation system controlled the ventilation rate by directly or indirectly tracking the traffic load in real-time after sensing data, using vehicle detection sensors and carbon monoxide (CO) and carbon dioxide ($CO_2$) sensor. The ventilation system has operated for 9 hours per a day. It responded real-time data every 10 minutes, providing ventilation rate in conformance with the input traffic load or contaminant level at that time. A ventilation rate of pilot ventilation system can be controlled at 8 levels. The reason is that a ventilation unit consists of 8 high-speed nozzle jet fans. This study proposed vehicle detection sensor based demand-controlled ventilation (VDS-DCV) strategy that would accurately trace direct traffic load and CO sensor based demand-controlled ventilation (CO-DCV) strategy that would indirectly estimate traffic load through the concentration of contaminants. In order to apply DCV strategy based on real-time traffic load, the minimum required ventilation rate per a single vehicle was applied. It was derived through the design ventilation rate and total parking capacity in the underground parking lot. This is because current ventilation standard established per unit floor area or unit volume of the space made it difficult to apply DCV strategy according to the real-time variation of traffic load. According to the results in this study, two DCV strategies in the underground parking lot are considered to be a good alternative approach that satisfies both energy saving and healthy indoor environment in comparison with the conventional control strategies.

콤비스티머 오븐조리조건이 돈가스 품질 특성에 미치는 영향 (Effect of Combisteamer Oven Cooking Condition on Quality Characteristics of Pork Cutlets)

  • 김인철
    • 한국산학기술학회논문지
    • /
    • 제12권7호
    • /
    • pp.3123-3129
    • /
    • 2011
  • 돈가스는 청소년층이 선호하는 메뉴이지만 기름에 튀겨 조리하므로 지방함량과 칼로리가 높아 비만을 유발할 수 있는 메뉴이다. 본 연구에서는 이러한 점을 개선하여 국민건강에 기여하고자, 오븐을 이용한 돈가스의 조리 방법 개발 및 이에 따른 돈가스의 품질 특성을 연구하였다. 기름조리 방법을 대체하기 위하여, 갈색 생 빵가루에 카놀라 오일을 혼합하여 돈가스를 제조하였고, 오븐 조리시간, 온도, 습도, 팬 스피드를 최적화하였다. 기름조리 돈가스 대비 오븐조리 돈가스의 지방 함량과 칼로리는 55.4%, 28.6% 유의적으로 감소하였다(P<0.05). 색도와 조직감, 베터 분리율 분석에서 유의차가 없었으며(P>0.05), 관능평가 에서도 전체적인 맛 항목 등에서 유의차가 없었다(P>0.05). 따라서 돈가스를 최적화된 조건으로 오븐 조리한다면, 기름 조리 돈가스와 맛이 유사하여 고객의 선호도를 유지하고, 다이어트를 필요로 하는 사람들에게 유용할 것으로 기대된다.

적외선 신호저감 장치 모형시험을 위한 계측기의 성능평가 (Performance Evaluation of Measuring Instrument for Infra-Red Signature Suppression System Model Test)

  • 윤석태
    • 한국산업정보학회논문지
    • /
    • 제28권6호
    • /
    • pp.21-27
    • /
    • 2023
  • 현대 함정은 외부로 방사되는 적외선 신호를 낮추기 위해 폐기관에 적외선 신호저감 장치(Infra-Red Signature Suppression system, IRSS)를 설치한다. 그리고 함정은 생의 주기가 매우 긴 전략 자산으로 탑재 장비들의 성능에 대한 높은 신뢰성을 충분히 확보해야 한다. 따라서, IRSS와 같은 장비들은 설계 단계에서 모형시험을 통해 성능평가를 하고 있다. IRSS의 모형시험에서는 다양한 계측기기들이 사용된다. 그러므로, 모형시험 단계 이전에 계측기들의 신뢰성을 평가해야 한다. 본 연구에서는 IRSS 모형시험에 사용되는 계측 장비들의 신뢰성 평가에 관한 연구를 수행하였다. 시험 장비와 계측기는 열 풍동 시험기, 피토 튜브와 디지털 차압계, 열전대 센서 그리고 디지털 기록계가 사용되었다. 계측 결과 열 풍동 시험기의 풍속이 증가할수록 유동의 계측 편차가 감소하였으며, 열전대 센서의 온도는 사용 방법에 따라 반응 속도 및 민감도의 차이를 보였다.

Rapid assessment of suspension bridge deformation under concentrated live load considering main beam stiffness: An analytical method

  • Wen-ming Zhang;Jia-qi Chang;Xing-hang Shen;Xiao-fan Lu;Tian-cheng Liu
    • Structural Engineering and Mechanics
    • /
    • 제88권1호
    • /
    • pp.53-65
    • /
    • 2023
  • With the gradual implementation of long-span suspension bridges into high-speed railway operations, the main beam's bending stiffness contribution to the live load response permanently grows. Since another critical control parameter of railway suspension bridges is the beam-end rotation angle, it should not be ignored by treating the main beam deflection as the only deformation response. To this end, the current study refines the existing method of the main cable shape and simply supported beam bending moment analogy. The bending stiffness of the main beam is considered, and the main beam's analytical expressions of deflection and rotation angle in the whole span are obtained using the cable-beam deformation coordination relationship. Taking a railway suspension bridge as an example, the effectiveness and accuracy of the proposed analytical method are verified by the finite element method (FEM). Comparison of the results by FEM and the analytical method ignoring the main beam stiffness revealed that the bending stiffness of the main beam strongly contributed to the live load response. Under the same live load, as the main beam stiffness increases, the overall deformation of the structure decreases, and the reduction is particularly noticeable at locations with original larger deformations. When the main beam stiffness is increased to a certain extent, the stiffening effect is no longer pronounced.

FPGA를 이용한 유도 전동기의 디지털 전류 제어 시스템 구현 (Implementation of the Digital Current Control System for an Induction Motor Using FPGA)

  • 양오
    • 전자공학회논문지C
    • /
    • 제35C권11호
    • /
    • pp.21-30
    • /
    • 1998
  • 본 논문에서는 FPGA를 이용하여 산업용 구동장치로 널리 사용되고 있는 유도 전동기의 디지털 전류 제어시스템을 구현하였다. 이를 위해 VHDL을 이용하여 FPGA를 설계하였으며 이 FPGA는 PWM 발생부, PWM 보호부, 회전속도 검출부, 프로그램 폭주 방지부, 인터럽트 발생부, 디코더 로직부, 신호 지연 발생부 및 디지털 입·출력부로 각각 구성되어있다. 본 FPGA의 설계시 고속처리의 문제점을 해결하기 위해 클럭전용핀을 활용하였으며 또한 40 MHz에서도 동작할 수 있는 삼각파를 만들기 위해 업다운 카운터와 래치부를 병렬 처리함으로써 고속화하였다. 특히 삼각파와 각종 레지스터를 비교 연산할 때 많은 팬아웃 문제에 따른 게이트 지연(gate delay) 요소를 줄이기 위해 병렬 카운터를 두어 고속화를 실현하였다. 아울러 삼각파의 진폭과 주파수 및 PWM 파형의 데드 타임 등을 소프트웨어적으로 가변 하도록 하였다. 이와 같은 기능들을 FPGA로 구현하기 위하여 퀵로직(Quick Logic)사의 pASIC 2 SpDE와 Synplify-Lite 합성툴을 이용하여 로직을 합성하였다. 또한 Verilog HDL 환경에서 최악의 상황들(worst cases)에 대한 최종 시뮬레이션이 성공적으로 수행되었다. 아울러 구현된 FPGA를 84핀 PLCC 형태의 FPGA로 프로그래밍 한 후 3상 유도전동기의 디지털 전류 제어 시스템에 적용하였다. 이를 위해 DSP(TMS320C31-40 MHz)와 FPGA, A/D 변환기 및 전류 변환기(Hall CT) 등을 이용하여 3상 유도 전동기의 디지털 전류 제어 시스템을 구성하였으며, 디지털 전류 제어의 효용성을 실험을 통해 확인하였다.

  • PDF

대면교행터널에서 배연시스템의 구축과 화재모형실험에 의한 적정성 평가 (Construction of the Smoke Exhaust System and Its Applicability by the Fire Model Test for a Bidirectional Tunnel)

  • 이상은;이창우
    • 터널과지하공간
    • /
    • 제15권6호
    • /
    • pp.452-461
    • /
    • 2005
  • 대면 교행 터널의 경우 차량의 교행으로 사고 위험성이 일방향 터널에 비해 1.5배 정도 높으므로 화재가 발생할 위험성도 커지게 되며, 터널내 화재시 입출구로 이용객이 대피하므로 인명 대피 완료전까지 제트팬을 가동하지 못하는 문제가 있다. 특히 장대터널의 경우 연기확산으로 인하여 대형 인명 피해가 발생하기 때문에 터널내에 별도의 인명 대피 통로와 배연 시스템을 구축하여 인명 피해를 최소화하는 것이 필요하다. 본 연구에서는 화재 시뮬레이션 및 축소모형실험을 수행하여 터널내에 구축된 배연시스템의 효과를 검증하였다. 실험결과 대피 통로만 설치시는 최종 인명 대피 시간이 335초가 소요되었으나, 배연 시스템을 구축할 때는 185초가 소요되었다. 또한 화재원 부근의 온도가 $60^{\circ}C$ 정도 감소되었으며, 연기 확산 속도는 배연 시스템 미가동시 $0.36\~0.82\;m/sec$이고, 가동시는 $0.27\~0.58\;m/sec$로 현격히 감소하였다. 위 결과로부터 대피자의 이동속도가 $0.7\~1.0\;m/sec$인 점을 고려할 때, 150 m 간격으로 설치된 피난문을 통해 안전한 대피가 가능하였다. 본 연구는 배연시스템에 대한 화재모형실험 분석을 통해 향후 대면 교행 터널의 방재에 대한 기초자료를 제공하는데 그 의미가 있다.

토마토 재배 온실의 환경조절에 따른 온습도 균일도 분석 (Analysis on the Uniformity of Temperature and Humidity According to Environment Control in Tomato Greenhouses)

  • 남상운;김영식
    • 생물환경조절학회지
    • /
    • 제18권3호
    • /
    • pp.215-224
    • /
    • 2009
  • 공기유동 제어기술의 개발을 위한 기초자료를 제공 할 목적으로 토마토 재배 온실의 냉난방과 환기 및 공기유동 관련 실태를 조사하고, 온실유형과 난방방식별 온습도 분포를 실측하여 균일도를 분석하였다. 충남 부여 세도지역의 토마토 재배 온실 136농가를 대상으로 조사한 결과 대부분을 차지하는 단동 플라스틱 온실의 천창 설치 비율이 낮고 환기팬과 유동팬 설치비율도 매우 낮을 뿐만 아니라 설치제원도 편차가 매우 큰 것으로 나타났다. 아치형 단동 플라스틱온실의 천창 환기 구조의 개발보급과 연동곡부의 천창도 지붕상부로 이동시킬 필요가 있으며, 개별 천창구조 및 환기팬과 유동팬에 대한 설치 가이드라인의 제정이 요구된다. 냉방설비를 설치한 농가는 하나도 없었으며 난방방식의 대부분을 차지하는 온풍난방에서 덕트의 설치제원 역시 편차가 큰 것으로 나타났고, 온풍덕트의 배기풍속 및 배기온도 또한 거리에 따른 편차가 매우 큰 것으로 관측되었다. 수출경쟁력 화보를 위한 고품질의 생산물을 연중 안정적으로 생산하기 위해서는 온실냉방기술의 보급이 절실하며 난방방식이나 덕트설치 방식의 개선이 필요한 것으로 판단된다. 온실내 온습도 분포가 균일한지 여부를 판단하는 지표로 사용되고 있는 최대 편차와 실제 균등한 정도를 나타낼 수 있는 균일도와의 관계를 분석해 본 결과 높은 상관관계를 보였으나 주간에는 직선식으로 야간에는 2차 곡선식으로 다르게 표현되었다. 온습도 분포의 균일한 정도를 판정할 수 있는 객관적인 기준이 마련된다면 최대편차 대신 균일도를 지표로 사용하는 것이 더 합리적일 것으로 판단된다. 온실유형과 난방방식에 따라 온 습도분포의 균일도가 상당히 다른 것을 확인할 수 있었으며 야간에는 온수난방의 경우 이랑배관으로, 온풍난방의 경우 온풍덕트의 적절한 배치를 통하여, 주간에는 환기와 공기유동을 통하여 균일도를 개선할 수 있을 것으로 판단되었다.

온실 ICT융복합 실태조사와 복숭아형 랙피니언천창 적용 단동온실 및 CFD 유동해석 (Survey of ICT Apply to Plastic Greenhouse, Rack·Pinion Adaption to Single Span and CFD Analysis)

  • 조규정;김기영;양원모
    • 생물환경조절학회지
    • /
    • 제24권4호
    • /
    • pp.308-316
    • /
    • 2015
  • 최근 관심이 집중되고 있는 스마트온실의 기술적용 실태와 문제점을 파악하고 이를 토대로 단동온실의 ICT 기술적용 장애요인 극복과 생산성을 제고하기 위하여 실험을 수행하였다. 자동화 시설의 도입 장애요인으로는 시설비 부담(24%)이 높았으며, 설치업체 사후관리 미흡(19%), 잦은 고장(16%), 관리기술 미흡(15%), 기능 미흡(13%), 소득향상기여 미흡(12%) 순이었다. ICT 도입필요성은 노동력절감(15%)이 가장 높았다. 자동화 온실에서 문제가 발생되는 부분은 온실구조, 구동기제어, 복합환경제어기, 센서기술이 각 14%로 비슷하였고, 원격제어기술 13%, 작물관리기술 12%, 에너지절감기술 10%, 소프트웨어활용 8%이었다. 온실구조 측면에서의 문제점은 천창개선이 18%로 가장 많았다. 효율적인 온도 및 환기 제어를 위해 농촌진흥청 고시 10-단동-7형 온실에 랙피니언 천창을 추가하였으며, 지붕형태를 복숭아형으로 변경하였다. 온실내 환경의 균일성을 위해 공기 유동팬은 6대를 설치하도록 하되 필요에 따라 증설 가능하도록 하였으며, 에너지 절약을 위해 1, 2중은 두께 0.1mm필름을 사용하고 3중은 5겹보온커튼을 설치하였다. CFD 유동해석 결과, 측창이 열린조건에서는 풍상 방향의 평균 유속이 빠르고 온도가 낮았으며, 풍하 방향으로 멀어 질수록 평균 유속이 점차 느려지고 온도는 높게 나타났다. 반면, 측창이 닫힌조건에서는 평균 유속이 낮으며, 구역별로 큰 편차는 없었다. 다만 풍상 풍하의 천창이 모두 열린 조건에 비하여 풍하 방향의 천창만 열린조건이 영역별 평균 유속에서 더 높은 값을 보였다. 측창을 닫은 조건에서는 외기의 유동이 아닌 온실 내 설치된 환기용 유동팬에 의해 유속이 발생하며 외부 환기가 없는 조건에서 유동팬에 의한 순환은 실내 전체 공간의 유동 편차를 줄여 줄 수는 있지만 전체적인 온도에는 영향을 미치지 못하였다. 저측고의 영역별 평균 온도는 고측고보다 균일하게 나타났다. 겨울철 3중 다겹보온커튼 여닫음에 관계없이 유동팬 근처에서 유속이 높고 유동팬에서 멀어지면 유속이 거의 없는 것으로 나타났다. 또한, 시간경과에 따른 평균 온도는 3중다겹보온커튼 열림상태에서 약 2시간 후에 외부온도와 같아졌으나 닫힘상태에서는 5시간 이후에 외부온도와 같아져, 3중 다겹보온커튼의 보온효과가 뚜렷하였다. 같은 조건에서 열용량의 차이로 인해 저측고 온실이 고측고 온실에 비하여 온도 하강 속도가 빨랐다.