• Title/Summary/Keyword: High school building

Search Result 1,037, Processing Time 0.028 seconds

Evaluating Performance of Energy Conservation Measures on Energy-Efficient Remodeling at Deteriorated High School Buildings (노후 고등학교 건물의 에너지효율화 리모델링을 위한 요소기술의 성능 평가)

  • Lhee, Sang Choon;Choi, Young Joon;Choi, Yool
    • KIEAE Journal
    • /
    • v.13 no.5
    • /
    • pp.97-102
    • /
    • 2013
  • Many countries over the world have acknowledged the global warming problem by greenhouse gas emission and tried to solve the problem. The Korean government has also taken many actions such as The Act on Low Carbon, Green Growth and on Promoting Green Building in that architectural building section takes 1/4 of national greenhouse gas emission. Under the situation that buildings constructed 15 years ago when insulation standards were reinforced take about 74%, The Plan on Vitalizing Green Remodeling, finally established on July 2013, will induce energy-efficient remodeling of deteriorated buildings. Using the energy simulation by the Visual DOE 4.0 program, this paper proposed the ways of energy-efficient remodeling of deteriorated high school buildings by measuring energy saving performance of factors that were drawn from the previous study. The factors considered are insulation, window's SHGC, south louver, system efficiency, and indoor setting temperature. Among them, all factors except SHGC proved contribution to reducing energy use at deteriorated high school buildings, compared with the baseline energy consumption.

A Study on the Window Planning of School Building Using ECOTECT Simulation -By Dynamic Daylight Simulation Using Weather Data- (ECOTECT 시뮬레이션을 활용한 학교건축의 창호계획에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로-)

  • Choi, Woo Ram;Han, Seok Jong;Yun, Young Il
    • KIEAE Journal
    • /
    • v.13 no.6
    • /
    • pp.77-82
    • /
    • 2013
  • Light environment in the school building is one of the most important elements of the plan in order to improve student's ability to learn and the healthy growth. Thus, the window plan of the school building is a great addition to improve environmental-friendly performance through the daylight control. Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the school building design process, because of lack of previous studies on the light environment of student and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. ECOTECT simulation were performed using weather data. As a result, ECOTECT simulation are performed for daylight autonomy and useful daylight illuminance. Using this data, Window planing is to propose and effective method in the early stages of design.

Aerodynamic measurements of across-wind loads and responses of tapered super high-rise buildings

  • Deng, Ting;Yu, Xianfeng;Xie, Zhuangning
    • Wind and Structures
    • /
    • v.21 no.3
    • /
    • pp.331-352
    • /
    • 2015
  • A series of wind tunnel tests were conducted on tapered super high-rise buildings with a square cross section by applying synchronous pressure measurement technology. The effects of global strategy of chamfered modification on aerodynamic loads and wind-induced responses were investigated. Moreover, local aerodynamic strategies of opening a ventilation slot in the corner of equipment and refuge floors were carried out. Results show that the global strategy of tapered elevation increased the vortex shedding frequency, but reduced vortex shedding energy, leading to reduction of across-wind aerodynamic loads and responses. Chamfered modification suppressed the across-wind vortex shedding effect on tapered buildings. Opening the ventilation slot further suppressed the strength of vortex shedding and reduced the residual energy related to vortex shedding in aerodynamic loads of chamfered buildings. Finally, the optimized locations of local aerodynamic strategies were suggested.

A Theoretical Study for Stack Effect driven Natural Ventilation System in High-rise Building (고층건물에서 연돌효과를 활용한 자연환기시스템 설계를 위한 이론적 고찰)

  • Yoon, Sung-Min;Seo, Jung-Min;Kim, Yang-Soo;Lee, Joong-Hoon;Song, Doo-Sam
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.123-129
    • /
    • 2009
  • In these days, the green building movement caused by the energy crisis is increasing, passive design is getting mere and more attention as it provides many possibilities for energy conservation. Moreover, with the increasing social intention for healthy life, the demand for indoor air Quality is increasing in Korea. As result, the ventilation system which can provide the sound outdoor air constantly has been obliged in Korea. So, the hybrid system which using natural power and mechanical power and makes up for the shortage of mechanical and natural ventilation attracts people's attention in Korea. As a hybrid ventilation system, in this study, the stack effect driven hybrid ventilation system in high-rise residential building will be suggested. And in this paper, the theoretical review for hybrid ventilation system suggested in this study will be addressed. Especially, the characteristics of pressure distribution and airflow caused by stack effect in high-rise residential building and the possibility of natural ventilation as results of stack effect will be described.

  • PDF

Workshop Method Adaptation of SI Theory for Applying Closed Schools (SI(Skeleton/Infill)이론을 적용한 폐교활용의 워크숍 방법론)

  • Yi, Yong Kyu
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 2011
  • Despite the high historical and topological values, closed schools are rarely reutilized. The reason can be likely explained by integrity of the building structure and unawareness of the operation and maintenance for closed schools. The purpose of this study is finding a possibility of reusing closed schools by deploying SI (Skeleton and Infill) theory. SI theory is separating the "skeleton" like structure from "infill" such as interior furnishings to extend building life without complete demolishing of the building. It will allow satisfying various local community demands by alternating infill without demolishing of historical and topological value of the building. The experimental test was undertaken with closed school for this study. The local community's demands or opinions were reflected to develop a strategy for deploying infill system especially movable storage furniture to closed school. The study finds possibilities that SI theory can assist local community to 1) construct potential demand for utilizing closed school and 2) suggest strategy for operating and maintaining closed school.

Dynamic field monitoring data analysis of an ancient wooden building in seismic and operational environments

  • Lyu, Mengning;Zhu, Xinqun;Yang, Qingshan
    • Earthquakes and Structures
    • /
    • v.11 no.6
    • /
    • pp.1043-1060
    • /
    • 2016
  • The engineering background of this article is an ancient wooden building with extremely high historic and cultural values in Tibet. A full understanding of the dynamic behaviour of this historic building under in-service environments is the basis to assess the condition of the structure, especially its responses to earthquake, environmental and operational loading. A dynamic monitoring system has been installed in the building for over one year and the large amounts of high quality data have been obtained. The paper aims at studying the dynamic behaviour of the wooden building in seismic and operational conditions using the field monitoring data. Specifically the effects of earthquake and crowd loading on the structure's dynamic response are investigated. The monitoring data are decomposed into principal components using the Singular Spectrum Analysis (SSA) technique. The relationship between the average acceleration amplitude and frequencies of the principle components and operational conditions has been discussed. One main contribution is to understand the health condition of complex ancient building based on large databases collected on the field.

Comparison of various k-ε models and DSM applied to flow around a high-rise building - report on AIJ cooperative project for CFD prediction of wind environment -

  • Mochida, A.;Tominaga, Y.;Murakami, S.;Yoshie, R.;Ishihara, T.;Ooka, R.
    • Wind and Structures
    • /
    • v.5 no.2_3_4
    • /
    • pp.227-244
    • /
    • 2002
  • Recently, the prediction of wind environment around a building using Computational Fluid Dynamics (CFD) technique comes to be carried out at the practical design stage. However, there have been very few studies which examined the accuracy of CFD prediction of flow around a high-rise building including the velocity distribution at pedestrian level. The working group for CFD prediction of wind environment around building, which consists of researchers from several universities and private companies, was organized in the Architectural Institute of Japan (AIJ) considering such a background. At the first stage of the project, the working group planned to carry out the cross comparison of CFD results of flow around a high rise building by various numerical methods, in order to clarify the major factors which affect prediction accuracy. This paper presents the results of this comparison.

Analyzing for the Circumstancial Influence Factor in Building Maintenance Expenses (건축물 유지관리비의 환경적 영향 요인 분석)

  • Yang, Hoe-Ryeong;Shin, Han-Woo;Kim, Tae-Hui
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.120-121
    • /
    • 2013
  • Apartment houses maintenance like remodeling in at issue and the importance is getting higher. On this study, we analyzed a variety of the influence factor affected building's maintenance expenses. circumstance influence factor about maintenance expenses is classified into region(big city, small and medium city), (area of high snowfall), (downpour region), (earthquake region), location(waterfront, inland province), using condition(mixed use, single use), frequency of use(kindergarten, middle school, high school), architecture method(reconstruction, construction).

  • PDF

A Study on the Open Space in the Elementary School from the Standpoint of Architectural Planning - An Analysis of the Situations of Establishment and Using Method of the Open Space in Japan - (국민학교(國民學校)의 다목적(多目的) 스페이스에 대한 건축계획적(建築計劃的) 연구(硏究) - 일본(日本)의 다목적(多目的) 스페이스 설치(設置).이용(利用)의 현황(現況) 분석(分析) -)

  • Rieu, Ho-Seoup
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.2 no.2
    • /
    • pp.27-39
    • /
    • 1995
  • It is a well-known fact that most of the Korean school buildings has been adjusted by the standard plan according to the united and unified teaching method ever since the modern education started. However, seeing the recent growth of care for the open education, the effort to improve the teaching method in school fileds, the practice of the 6th education plan and the education reformation, it can be said that it is high time to change. As the number of schools which practice the open education has been increasing since in 1985 in this atmosphere, there have also appeared elementary schools with the open school building. But the general understanding of the school building and the open space is not enough. Therefore, this study aims to analyze the general spacial conditions, such as the fresh and diverse types of learning method and their development and the concept of the open space along with its types, application, size, and constition by studying, from the standpoint of the building plan, the elimentary schools of a new type in Japan which adopted the open space 20years earlier than in Korean. This study can offer helpful suggestions as to the Korean school building because our situation is very similar to the early stage where the open space is adopted to the school building.

  • PDF

Correlation Analysis Between Fenestration Energy Consumption Efficiency Rating System and Building Energy Consumption (창호 에너지 소비 효율 등급제와 건물 에너지 소비의 상관관계 분석)

  • Kwak, Hee-Jeong;Jang, Hyang-In;Lee, Hyun-Soo;Eom, Jae-Yong;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.338-345
    • /
    • 2013
  • The purpose of this study is to analyze the correlation between the 'Fenestration Energy Consumption Efficiency Rating System' (hereafter referred to as FECERS) and building energy consumption. 'EnergyPlus' was used for the calculation of energy consumption in apartments and office buildings, according to FECERS's rating and SHGC. The result indicates that the FECERS has high correlation with apartments, but has low correlation with office buildings. Also, it indicates that office buildings have a large impact from SHGC, which is not reflected in the FECERS. Consequently, the FECERS needs to be improved, by adding optical properties to assessment items. Additional study is required to establish the fenestration rating system, which, on the basis of this work, has high relevance to building energy consumption.