• Title/Summary/Keyword: High school building

Search Result 1,037, Processing Time 0.022 seconds

3D BUILDING INFORMATION EXTRACTION FROM A SINGLE QUICKBIRD IMAGE

  • Kim, Hye-Jin;Han, Dong-Yeob;Kim, Yong-Il
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.409-412
    • /
    • 2006
  • Today's commercial high resolution satellite imagery such as IKONOS and QuickBird, offers the potential to extract useful spatial information for geographical database construction and GIS applications. Recognizing this potential use of high resolution satellite imagery, KARI is performing a project for developing Korea multipurpose satellite 3(KOMPSAT-3). Therefore, it is necessary to develop techniques for various GIS applications of KOMPSAT-3, using similar high resolution satellite imagery. As fundamental studies for this purpose, we focused on the extraction of 3D spatial information and the update of existing GIS data from QuickBird imagery. This paper examines the scheme for rectification of high resolution image, and suggests the convenient semi-automatic algorithm for extraction of 3D building information from a single image. The algorithm is based on triangular vector structure that consists of a building bottom point, its corresponding roof point and a shadow end point. The proposed method could increase the number of measurable building, and enhance the digitizing accuracy and the computation efficiency.

  • PDF

Characteristics of the aerodynamic interference between two high-rise buildings of different height and identical square cross-section

  • Dongmei, Huang;Xue, Zhu;Shiqing, He;Xuhui, He;Hua, He
    • Wind and Structures
    • /
    • v.24 no.5
    • /
    • pp.501-528
    • /
    • 2017
  • In this work, wind tunnel tests of pressure measurements are carried out to assess the global aerodynamic interference factors, the local wind pressure interference factors, and the local lift spectra of an square high-rise building interfered by an identical cross-sections but lower height building arranged in various relative positions. The results show that, when the interfering building is located in an area of oblique upstream, the RMS of the along-wind, across-wind, and torsional aerodynamic forces on the test building increase significantly, and when it is located to a side, the mean across-wind and torsional aerodynamic forces increase; In addition, when the interfering building is located upstream or staggered upstream, the mean wind pressures on the sheltered windward side turn form positive to negative and with a maximum absolute value of up to 1.75 times, and the fluctuating wind pressures on the sheltered windward side and leading edge of the side increase significantly with decreasing spacing ratio (up to a maximum of 3.5 times). When it is located to a side, the mean and fluctuating wind pressures on the leading edge of inner side are significantly increased. The three-dimensional flow around a slightly-shorter disturbing building has a great effect on the average and fluctuating wind pressures on the windward or cross-wind faces. When the disturbing building is near to the test building, the vortex shedding peak in the lift spectra decreases and there are no obvious signs of periodicity, however, the energies of the high frequency components undergo an obvious increase.

A Study on Layout Types of High Schools - Focused on High Schools Which Were Built from 2000 to 2004 in Gyeonggi Province - (고등학교 배치유형에 관한 연구 - 경기도내 2000년에서 2004년 건립될 고등학교를 중심으로 -)

  • Kim, Mi-Hyung;Lee, Eul-Kyu;Kim, Jun-Kyung
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.12 no.4
    • /
    • pp.5-16
    • /
    • 2005
  • The objective of this study is to analyze the layout types by the characteristics of 24 high school sites in Gyeonggi-do. These 24 high schools were built to establish the learner-oriented education in high schools to comply with the 7th Curriculum of the Ministry of Education. The 7th Curriculum has been altered from the supply-oriented to the demand-oriented and learner-oriented one since the year of 2000 to meet the demands of the fast moving society. For this study, the following researches have been conducted; 1) Literature were reviewed to examine the educational systems that supported architectural planning of existing high schools. 2) The environment and characteristics of the high school sites were investigated and current move in planning of high school site was examined. 3) Layout types were classified by the configurations of existing high school buildings. The output of this study was used to find the architectural data such as building site, building coverage, floor area ratio, the number of floors, site shape, direction and front of building.

Analysis Performance of Super Window through Simulation and Verification Experiment (시뮬레이션과 실증실험을 통한 슈퍼윈도우의 성능분석)

  • Peak, Sang-Hun;Lee, Jin-Sung;Cho, Soo;Jang, Cheol-Yong;Sung, Uk-Joo;Suh, Seung-Jik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1069-1074
    • /
    • 2006
  • Heat loss by window in building occupies about 1/4 of energy amount used building. Therefore, high thermal insulation of windows system can speak as very important part in save energy of building. in this research, After select most suitable frame design and Glazing system for high thermal insulation of windows, execute simulation of mixing frame and Glazing System. Also, manufacture windows with the result and execute verification experiment, with verified simulation, this research evaluated thermal insulation performance of window by Glazing System's change.

  • PDF

Performance Evaluation of BIPV Systems Applied in School Buildings (학교 건축에 대한 BIPV시스템의 성능 평가)

  • Park, Kyung-Eun;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.11 no.5
    • /
    • pp.14-23
    • /
    • 2004
  • Building-integrated photovoltaic(BIPV) systems can operate as a multi-functional building components, which generates electricity and serves as part of building envelope. It can be regarded as a new architectural elements, adding to the building's aesthetics. Besides of these benefits, the application of PV systems into school buildings tends to play an important role in energy education to students. In this context, this study aims to analyse the applicability of PV systems into school buildings. For an existing school building, four types of BIPV designs were developed; rooftops, wall-attached, wall-mounted with angle, and sunshading device. Based on energy modeling of those BIPV systems, the whole 60.1kWp rated PV installation is expected to yield about 65.6MWh of electricity, that is about 50% more than the annual electricity consumption of the school, 44MWh. It was also found that the applicability of the PV systems into the school building was very high, and the rooftop systems with the optimized angle was the most efficient in energy production, followed by sunshading, wall-mounted with angle and wall-attached. It concludes that school buildings have a reasonable potential to apply PV systems in the aspects of building elements and electricity production.

Environmental Impact Assessment at a School Building using Input-output Table - Focused on Elementary School in Gyeonggi-do - (산업연관분석법을 이용한 학교 건물에서의 환경영향평가 - 경기지역의 초등학교를 대상으로 -)

  • Choi, Doo-Sung;Jeon, Hung-Chan;Cho, Kyun-Hyong
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.57-62
    • /
    • 2016
  • Purpose: A lot of active researches have addressed the impact of a building on global environment, but most of the researches focus on a residential building and a large office building. Hereupon, this study assessed the impact on environment quantitatively through the analysis of input materials targeting a school building. Method:This study calculated embodied energy of input materials suggested in a construction statement on a school building using the input-output analysis. This study finally carried out environmental impact assessment by applying LCIA DB shown in the preceding researches to the calculated embodied energy. Result: The analysis result revealed that the environmental impact per unit area(/$m^2$) at a school building was $4.11E-02PE{\cdot}yr$, among which Construction was found to be $3.59E-02PE{\cdot}yr$, being analyzed to account for about 87% of the total environmental impact. Also, as a result of detailed environmental impact, the impact on global warming among the total environmental impact was analyzed to be high, accounting for about 76%.

The Estimation of Construction Duration for High School Buildings Based on the Actual Data (실적자료에 의한 고등학교 시설 공기산정)

  • Kwon Dong-Chan;Lee Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.6 s.22
    • /
    • pp.138-145
    • /
    • 2004
  • The construction duration for any building or facilities such as high school building influence the quality of the building as well as the total cost for them. Since there are no guidelines to estimate construction duration correctly, an employer(or owner) estimate it by their own experience or intuition. Therefore some conflicts related to construction duration happen between contract parties during construction. The purpose of this study is to suggest a predictive model which helps decision makers calculate exact net working days for high school building construction at the early stage of the construction project. To measure net working days for high school construction, 15 data were collected from actual spot in Incheon region. Multiple linear regression analysis was conducted to obtain the model which calculate construction duration for the substructure, the superstructure and the finishing works. total construction duration could be obtained by adding net working days to non working days which would be based on the meteorological statistics for Incheon region since 1974 to 2003.

Effect of the a floor plan of lobby floor for the Stack Effect in a High-rise Building (고층건물에서 로비층의 평면형태가 연돌효과에 미치는 영향)

  • Lee, June-Ho;Lim, Hyun-Woo;Seo, Jung-Min;Lee, Joong-Hoon;Song, Doo-Sam
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.293-299
    • /
    • 2009
  • Many kinds of problems by stack effect occur in the high-rise buildings that have the simple plan on the first floor designed only by an external wall and an E/V shaft wall. Therefore, some buildings in the foreign countries has made the additional inside walls between lobby and E/V hall as a countermeasure on stack effect. An additional wall in the lobby is very useful countermeasure on stack problems because lobby is a main airflow path in the building. Decreasing effect on stack problems by an additional wall of lobby is reported in this study. An ordinary office building that has a simple lobby plan is simulated and measured in this study. The results show that characteristics on stack effect are changed by methods of applying additional walls and that alternations of countermeasures which building conditions like the kinds of problems and the problem's velocity etc. are considered are very important.

  • PDF

Consideration of Ozone Removal and Control in Built Environment by Building Materials (건축자재에 의한 실내 오존제거 및 제어에 대한 고찰)

  • Chung, Ok-Young;Jeong, Su-Gwang;Kim, Jun-Hyun;Kim, Su-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.467-475
    • /
    • 2012
  • Recently, residents have been spending almost 90% of their time indoors, which presents a higher risk from inhalation of pollutants than when spending time outdoors. Therefore, controlling indoor air quality became important. It is reported that the lung diseases and mortality for occupants are increased when there is high density of ozone which is one of the pollutants among the indoor air. In addition, the reactions between ozone and building materials produce VOCs and formaldehyde. The studies to eliminate the ozone by building materials have been actively investigated. However, ozone removal and secondary pollutants from ozone reactions with building materials have not been reported in Korea. For this reason, the aim of this study is to introduce ozone removal by HVAC filters, various building materials, and eco-friendly building materials including the quantity of secondary pollutant emissions.

Control Performance Evaluation of Outrigger Damper System of Eccentrically Loaded High-Rise Building (편심하중을 가한 고층건물의 아웃리거 댐퍼 시스템 제어성능평가)

  • Kim, Su-Jin;Kim, Su-Geun;Kang, Ho-Geun;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.43-51
    • /
    • 2017
  • The demand for skyscrapers is increasing worldwide. Until now, various lateral resistance structures have been used for lateral displacement control of high-rise buildings. An outrigger damper system has been introduced recently to improve lateral dynamic response control performance further. However, a study of outrigger damper system is yet to be sufficiently investigated. In this study, time history analysis was performed to investigate the control performance of an outrigger damper system of high-rise building under eccentric loading. To do this, an actual scale 3-dimensional tall building model with an outrigger damper system was prepared. The control performance of the outrigger damper system was evaluated by varying stiffness and damping values. On the top floor torsional angle response to the earthquake load, was greatly affected by damping value. And the displacement response was affected greatly by the stiffness value and damping value of damper system. In conclusion, it is necessary to select the proper damping and stiffness values of the outrigger damper system.