• Title/Summary/Keyword: High school building

Search Result 1,030, Processing Time 0.028 seconds

Particle Image Velocimetry Measurement of Unsteady Turbulent Flow around Regularly Arranged High-Rise Building Models

  • Sato, T.;Hagishima, A.;Ikegaya, N.;Tanimoto, J.
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.2
    • /
    • pp.105-113
    • /
    • 2013
  • Recent studies proved turbulent flow properties in high-rise building models differ from those in low-rise building models by comparing turbulent statistics. Although it is important to understand the flow characteristics within and above high-rise building models in the study of urban environment, it is still unknown and under investigation. For this reason, we performed wind tunnel experiment using Particle Image Velocimetry (PIV) to investigate and identify the turbulent flow properties and characteristic flow patterns in high-rise building models. In particular, we focus on instantaneous flow field near the canopy and extracted flow field when homogeneous flow field were observed. As a result, six characteristic flow patterns were identified and the relationship between these flow patterns and turbulent organized structure were shown.

Numerical study for downburst wind and its load on high-rise building

  • Huang, Guoqing;Liu, Weizhan;Zhou, Qiang;Yan, Zhitao;Zuo, Delong
    • Wind and Structures
    • /
    • v.27 no.2
    • /
    • pp.89-100
    • /
    • 2018
  • 3D simulations based on an impinging jet were carried out to investigate the flow field of a steady downburst and its effects on a high-rise building by applying the SST k-${\omega}$ turbulence model. The vertical profile of radial wind speed obtained from the simulation was compared with experimental data and empirical models in order to validate the accuracy of the present numerical method. Then wind profiles and the influence of jet velocity and jet height were investigated. Focusing on a high-rise building, the flow structures around the building, pressure distributions on the building surfaces and aerodynamic forces were analyzed in order to enhance the understanding of wind load characteristics on a high-rise building immersed in a downburst.

A Study on the Application of Small Wind Turbine System in Super High-rise Building (초고층 건물에서의 소형풍력발전시스템 적용에 관한 연구)

  • Park, Young Hyun;Park, Jung Ha;Park, Jin Chul;Rhee, Eon Ku
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.4
    • /
    • pp.187-193
    • /
    • 2013
  • Thanks to the characteristic of high-rise buildings, the increase of wind speed according to the height of a building makes it possible to use high wind power resources, many countries led by some advanced nations are recently making steady and persistent effort in introducing small wind turbine systems as a step to lower electric power load in high-rise buildings. The aim of this research is to propose an optimum application process of a small wind turbine system in high-rise buildings. To achieve this goal, the case studies on the applications of high-rise and tall buildings were conducted and the best application among them was selected. On the basis of the case studies, an application process was proposed.

Prediction of downburst-induced wind pressure coefficients on high-rise building surfaces using BP neural network

  • Fang, Zhiyuan;Wang, Zhisong;Li, Zhengliang
    • Wind and Structures
    • /
    • v.30 no.3
    • /
    • pp.289-298
    • /
    • 2020
  • Gusts generated by downburst have caused a great variety of structural damages in many regions around the world. It is of great significance to accurately evaluate the downburst-induced wind load on high-rise building for the wind resistance design. The main objective of this paper is to propose a computational modeling approach which can satisfactorily predict the mean and fluctuating wind pressure coefficients induced by downburst on high-rise building surfaces. In this study, using an impinging jet to simulate downburst-like wind, and simultaneous pressure measurements are obtained on a high-rise building model at different radial locations. The model test data are used as the database for developing back propagation neural network (BPNN) models. Comparisons between the BPNN prediction results and those from impinging jet test demonstrate that the BPNN-based method can satisfactorily and efficiently predict the downburst-induced wind pressure coefficients on single and overall surfaces of high-rise building at various radial locations.

A study on the Improvement Plans for Green Building Certification System -focused on the school use classification- (녹색건축물인증제도 개선방향에 관한 연구 -학교시설 용도구분 개선을 중심으로-)

  • Lee, Jae Ok;Meang, Joon Ho;Lee, Sang Min;Lee, Seung Min
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.11 no.2
    • /
    • pp.28-37
    • /
    • 2012
  • The purpose of this study is to suggest improvement plans of School Green Building Certification System by comparing items of domestic system with those of foreign system. Especially, we focused on school use classification. Use classification of Green Building Certification System must be based on Building Codes and reflect the nature of building use and size. Schools are divided into three groups ; preschool, school(elementary, junior high school, high school), university and ect. Also they must be set up assessment method reflecting the nature of school use and size.

Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building (노후 학교건물의 창호 교체에 따른 부하분석)

  • Lee, Ye Ji;Kim, Joo Wook;Song, Doo Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.9
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.

Analysis of three dimensional equivalent static wind loads of symmetric high-rise buildings based on wind tunnel tests

  • Liang, Shuguo;Zou, Lianghao;Wang, Dahai;Huang, Guoqing
    • Wind and Structures
    • /
    • v.19 no.5
    • /
    • pp.565-583
    • /
    • 2014
  • Using synchronous surface pressures from the wind tunnel test, the three dimensional wind load models of high-rise buildings are established. Furthermore, the internal force responses of symmetric high-rise buildings in along-wind, across-wind and torsional directions are evaluated based on mode acceleration method, which expresses the restoring force as the summation of quasi-static force and inertia force components. Accordingly the calculation methods of equivalent static wind loads, in which the contributions of the higher modes can be considered, of symmetric high-rise buildings in along-wind, across-wind and torsional directions are deduced based on internal forces equivalence. Finally the equivalent static wind loads of an actual symmetric high-rise building are obtained by this method, and compared with the along-wind equivalent static wind loads obtained by China National Standard.

A Study on Analysis of Air Flow for Wind Power System by Shape of Super High-rise building (초고층건물에서의 풍력발전 적용을 위한 건물형태별 기류분석)

  • Jang, Ho-Jin;Lee, Dong-Yun;Park, Jin-Chul;Rhee, Eon-Ku
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.42-47
    • /
    • 2011
  • This study aims to choose installation location of wind power system and analyze influence factors of wind power system by shape of super high-raise building by using CFD simulation. As a result of this study, wind power system is more applicable to streamlined building than normal building. Round openings are seemed to be the most efficient shape for building integrated wind power system in types applying venturi effect. Safety and vibration should be considered in the case of application of wind power system between the buildings.

  • PDF

Analysis of vortex induced vibration frequency of super tall building based on wind tunnel tests of MDOF aero-elastic model

  • Wang, Lei;Liang, Shuguo;Song, Jie;Wang, Shuliang
    • Wind and Structures
    • /
    • v.21 no.5
    • /
    • pp.523-536
    • /
    • 2015
  • To study the vibration frequency of super high-rise buildings in the process of vortex induced vibration (VIV), wind tunnel tests of multi-degree-of-freedom (MDOF) aero-elastic models were carried out to measure the vibration frequency of the system directly. The effects of structural damping, wind field category, mass density, reduced wind velocity ($V_r$), as well as VIV displacement on the VIV frequency were investigated systematically. It was found that the frequency drift phenomenon cannot be ignored when the building is very high and flexible. When $V_r$ is less than 8, the drift magnitude of the frequency is typically positive. When $V_r$ is close to the critical wind velocity of resonance, the frequency drift magnitude becomes negative and reaches a minimum at the critical wind velocity. When $V_r$ is larger than12, the frequency drift magnitude almost maintains a stable value that is slightly smaller than the fundamental frequency of the aero-elastic model. Furthermore, the vibration frequency does not lock in the vortex shedding frequency completely, and it can even be significantly modified by the vortex shedding frequency when the reduced wind velocity is close to 10.5.

A Study on the Application of Design Indicators of the High School Facilities - Focused on High School in Gyeonggi-do - (고교시설 디자인 지표의 적용 분석 연구 - 경기도 고등학교를 중심으로 -)

  • Cho, Kyung-Sik;Belyalova, Aigerim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.24 no.6
    • /
    • pp.45-53
    • /
    • 2017
  • The purpose of this study is to provide the fundamental data to improve a school building through comparing and analyzing facilities of high schools located in Gyeonggi - do Province on the basis of the Design Indicator for the Korean Educational Buildings. Two types of high schools were examined for this study. Some of them are high schools selected by Korean Ministry of Education as a school equipped with superior facilities and the others are high schools equipped with general facilities. 8 items such as safety, comfort, the function of education, utilization, the public, eco-friendliness, technology performance, economical efficiency were examined by 5 point Likert scale. Findings showed that all facilities of both types of high schools received high ratings in terms of safety, utilization, and technology performance. However, the evaluation index on 'various used outdoor space' and 'public buildings harmonized with surroundings' of the education function of both types of high schools was low, which implies that the facility related to the education function needs to be improved. It infers that facilities are simplified and harmony with surroundings disappears when altering the design of the school building due to the convenience of building and the problem of the budget. Therefore, these need to be primarily controlled. Additionally, in high schools with general facilities, the evaluation index on 'aesthetic interior and exterior design of comfort', 'the responsive space to the demand for teaching and learning of the function of education', and eco-friendless were so low that these factors need to be considered when designing the school building.