• Title/Summary/Keyword: High luminance

Search Result 550, Processing Time 0.027 seconds

Luminance Properties of Argon Gas Using Inductively Coupled Plasma (유도 결합형 플라즈마를 이용한 아르곤 가스의 휘도 특성)

  • Lee, Young-Hwan;Her, In-Sung;Hwang, Myung-Keun;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1915-1917
    • /
    • 2004
  • Inductively coupled plasma is commonly used for electrodeless lamp due to its ease of plasma generation. Optical characteristics significantly depend on the RF power and gas pressure of the plasma. This paper describes the measurement of luminance as a function of RF power and gas pressure with a goal of finding optimal operating conditions of the electrodeless lamp. The gas pressure was varied from 10 [mTorr] to 500 [mTorr] and the RF power was varied from 10 [W] to 200 [W]. It was found that the luminance tends to be decreased when argon pressure is increased, and the luminance is increased as RF power is increased. It was also found that the luminance per unit RF power is high when the argon pressure is low and when the RF power is in the range of 30 [W]${\sim}$40 [W].

  • PDF

Weighted error diffusion in PDP (PDP에서 가중치 오차확산 보정)

  • Jung, Han-Yung;Lee, Dong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.05a
    • /
    • pp.179-181
    • /
    • 2005
  • There is asymmetric in horizontal and vertical side of PDP cell. Every vertical line has BM(Black Mask) to improve luminance contrast. When error diffusion is processed in PDP system, these problems make an error bigger. In 4 inch PDP system, every red, green, blue color of test pattern is presented and each luminance is measured. That is called horizontal(H), diagonal right(R), diagonal left(L) and vertical(V). In red channel, high luminance descending order is V-H-R-L. In green channel, V-H-L-R. In blue channel, V-M-R=L. After average luminance of each direction is calculated. new weighted error diffusion(Weighted ED) is proposed. In digital image signal processing, the error in weighted ED is differ from ED's. The image of weighted ED is more less error compare to conventional ED and close to original image. As the gray level linearity and big size panel is adopted, weighted ED could produce good image.

  • PDF

An Evaluation of HDRI Builder for the Analysis of Indoor Lighting Environment (실내공간의 빛 환경 분석을 위한 HDRI Builder의 평가)

  • Shin, Eun-Ju;Hong, Sung-De
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.26-33
    • /
    • 2014
  • The purpose of this study is to evaluate the accuracy of luminance maps generated from five types of HDRI builder(High Dynamic Ranging Image builder) which include Photosphere, Bracket, Picturenaut, Luminance HDR and Photoshop. To accomplish this goal a set of experiments was conducted. In order to assess the luminance values of the HDR image from HDR image builder, the values had to be compared to the ones obtained from imaging photometer. After comparing measured luminance data using imaging photometer with those retrieved from the HDR images, Photosphere error rate estimated at 3% below.

Research and development on image luminance meter of road tunnel internal and external (도로터널 내/외부의 영상휘도 측정기 연구개발)

  • Jang, Soon-Chul;Park, Sung-Lim;Ko, Seok-Yong;Lee, Mi-Ae
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • This paper introduces the development of imaging luminance meter which measures the luminances of external/internal road tunnel. The developed imaging luminance meter complies with both L20 method and Veiling luminance method of the international standards, CIE88. In this paper the L20 method is mainly presented because most of tunnels currently adapt L20 method. The developed system has an embedded computer to operate at stand-alone. The system has a ethernet port, a heater, a fan, a defroster, a wiper and sun shielder. Compensation algorithm is applied for correcting non-linear responses to the luminance and integration time. The accuracy of measurement is less than 1% when it calibrated at the public certification institute. The developed system was also tested at the real field, road tunnel. The test results were very similar with the reference luminance meter and showed that the developed system operates well at the real field. Partial sensor saturations were happened to show the less luminance, because there were the high reflecting objects in the real field. Further study should be followed for high luminance measurement.

Ultra High Luminance and Luminous Efficacy MFFL (Mercury-free Flat Fluorescent Lamp) for Scanning Backlights of LCD TVs

  • Seo, In-Woo;Jung, Jae-Chul;Oh, Byung-Joo;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.231-234
    • /
    • 2009
  • In order to realize the high luminance and luminous efficacy MFFLs for LCD backlights, we optimized the phosphor profile to enlarge the surface area. The MFFL with the new phosphor profile shows a very wide luminance range from 2,600 to 17,000 nit with the corresponding luminous efficacy from 66 to 32.5 lm/W. The results were obtained with the color coordinate of the phosphor to be around (0.25, 0.23). And the single cell is expanded into a multi-structured configuration to realize a 32 inch-sized lamp by a simple repetition of the single cells, and a new driving scheme is proposed for an adaptive local dimming and scanning drive using dual auxiliary electrodes and bipolar drive scheme. Especially the ultra high luminance and luminous efficacy results suggest the duty time of illumination of the backlight unit can be significantly reduced.

  • PDF

An Adaptive Tone Reproduction for High Dynamic Range Image

  • Lee, Joo-Hyun;Jeon, Gwang-Gil;Jeon, Je-Chang
    • Journal of Broadcast Engineering
    • /
    • v.14 no.4
    • /
    • pp.428-437
    • /
    • 2009
  • A high dynamic range (HDR) image can represent real world scenes that have a wide range of luminance intensity. However, compared with the range of real world luminance, conventional display devices have a low dynamic range (LDR). To display HDR images onto conventional displayable devices such as monitors and printers, we propose the logarithmic based global reproduction algorithm that considers the features of the image using reproduction parameters. Based on the characteristics of the image, we first modify the input luminance values for reproducing perceptually tuned images and then obtain the displayable output values directly. The experimental results show that the proposed algorithm achieves good subjective results while preserving details of the image; furthermore, the proposed algorithm has a fast, simple and practical structure for implementation.

Comparative Luminance and Correlated Color Temperature of Work-place by a Fluorescent and LED Light Sources (LED광원과 형광광원에 의한 작업면의 휘도 및 색온도 비교)

  • Baik, Seung heon;Jeong, In Young;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.6
    • /
    • pp.21-26
    • /
    • 2008
  • According to the tendency of energy efficiency and environment-friendly chracteristics, demend of High-efficiency lighting using LED(Light Emitting Diode)are being increased actively and applied in various fields. However, In order to adequate application of LED light sources, it is necessary to lighting environment and luminous characteristics of LED light sources. This Study aims to characterize the work-plane lighting environment by LED light sources comparing with fluorescent light sources which are widely used. For the sake of this study, a fluorescent light source and 5 LED light sources were introduced and luminance and correlated color temperature were measured to evaluate luminance contrast. The experimental model is Mock-up which is $4.9m{\times}7.2m$ with a height of 2.9m. The test room was set up partition and desks. Luminance and correlated color temperature were measured work-plane on the desk which was set up local lighting by the Radiant Imaging ProMetric 1400. The optical characteristics data of LED can give a lot of advantages to design LED lighting appliances. Hereafter, the object of research will be conducted to evaluate effects of LED light sources on working performance, survey of visual performance, preference and physiology of subjects.

Hue Shift Model and Hue Correction in High Luminance Display (고휘도 디스플레이의 색상이동모델과 색 보정)

  • Lee, Tae-Hyoung;Kwon, Oh-Seol;Park, Tae-Yong;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.44 no.4 s.316
    • /
    • pp.60-69
    • /
    • 2007
  • The human eye usually experiences a loss of color sensitivity when it is subjected to high levels of luminance, and perceives a discrepancy in color between high and normal-luminance displays, generally known as a hue shift. Accordingly, this paper models the hue-shift phenomenon and proposes a hue-correction method to provide perceptual matching between high and normal-luminance displays. The value of hue-shift is determined by perceived hue matching experiments. At first the phenomenon is observed at three lightness levels, that is, the ratio of luminance is the same between high and normal-luminance display when the perceived hue matching experiments we performed. To quantify the hue-shift phenomenon for the whole hue angle, color patches with the same lightness are first created and equally spaced inside the hue angle. These patches are then displayed one-by-one on both displays with the ratio of luminance between two displays. Next, the hue value for each patch appearing on the high-luminance display is adjusted by observers until the perceived hue for the patches on both displays appears the same visually. After obtaining the hue-shift values, these values are fit piecewise to allow shifted-hue amounts to be approximately determined for arbitrary hue values of pixels in a high-luminance display and then used for correction. Essentially, input RGB values of an image is converted to CIELAB values, and then, LCh (lightness, chroma, and hue) values are calculated to obtain the hue values for all the pixels. These hue values are shifted according to the amount calculated by the functions of the hue-shift model. Finally, the corrected CIELAB values are calculated from corrected hue values, after that, output RGB values for all pixels are estimated. For evaluation, an observer's preference test was performed with hue-shift results and Almost observers conclude that the images from hue-shift model were visually matched with images on normal luminance display.

A New Driving Method for High Resolution AC PDP (고해상도 AC PDP를 위한 새로운 구동방식)

  • Cho, Young-Wan;Kwon, Oh-Kyong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.4
    • /
    • pp.45-53
    • /
    • 2001
  • We have proposed a new driving method of AC PDP for both high resolution over HDTV and high luminance. The new driving method can reduce data and scan pulse width to 0.85${\mu}s$ by utilizing both rising and falling edges of sustain pulse and can provide high resolution AC PDP with high luminance by increasing the number of addressing discharge using sustain pulses with phase shifts. As a result, the proposed driving scheme makes it possible to drive 2080 horizontal resolution panel with high luminance. The experimental results using 4-inch color AC PDP with $30{\times}58$ pixels indicate that the luminance can achieved up to 850 $cd/m^2$ without image noise when we employ the four phase shifted sustain pulses with the amplitude of 140V and the frequency of 125KHz.

  • PDF

The electro-magnetic properties of Xe type flat lamp by discharge electrode structure (Xe형 평면광원의 방전 전극 구조 변화에 따른 전자계 특성)

  • Yang, Jong-Kyung;Pack, Kwang-Hyun;Lee, Jong-Chan;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.15-18
    • /
    • 2005
  • As a display becomes large recently, Acquisition of high luminance and Luminance uniformity is becoming difficult in the existing CCFL or EEFL backlight system. So, study for a performance enhancement has enforced. but lamp development of flat type is asked for high luminance and a luminance uniformity security in of LCD and area anger trend ultimately. In this paper, we changed a tip shape of an electrode for production by the most suitable LCD backlight surface light source, and confirmed discharge characteristic along discharge gas pressure and voltage, and confirmed electric field distribution and discharge energy characteristic through a Maxwell 2D simulation. Therefore the discharge firing voltage characteristic showed a low characteristic than a rectangular type and round type in case of electrode which used tip of a triangle type, and displayed a discharge electric current as a same voltage was low.

  • PDF