• 제목/요약/키워드: High intensity light source

검색결과 132건 처리시간 0.029초

Enhancing Astaxanthin Accumulation in Haematococcus pluvialis by Coupled Light Intensity and Nitrogen Starvation in Column Photobioreactors

  • Zhang, Wen-wen;Zhou, Xue-fei;Zhang, Ya-lei;Cheng, Peng-fei;Ma, Rui;Cheng, Wen-long;Chu, Hua-qiang
    • Journal of Microbiology and Biotechnology
    • /
    • 제28권12호
    • /
    • pp.2019-2028
    • /
    • 2018
  • Natural astaxanthin mainly derives from a microalgae producer, Haematococcus pluvialis. The induction of nitrogen starvation and high light intensity is particularly significant for boosting astaxanthin production. However, the different responses to light intensity and nitrogen starvation needed to be analyzed for biomass growth and astaxanthin accumulation. The results showed that the highest level of astaxanthin production was achieved in nitrogen starvation, and was 1.64 times higher than the control group at 11 days. With regard to the optimization of light intensity utilization, it was at $200{\mu}mo/m^2/s$ under nitrogen starvation that the highest astaxanthin productivity per light intensity was achieved. In addition, both high light intensity and a nitrogen source had significant effects on multiple indicators. For example, high light intensity had a greater significant effect than a nitrogen source on biomass dry weight, astaxanthin yield and astaxanthin productivity; in contrast, nitrogen starvation was more beneficial for enhancing astaxanthin content per dry weight biomass. The data indicate that high light intensity synergizes with nitrogen starvation to stimulate the biosynthesis of astaxanthin.

머신 비전 라인 스캔 카메라를 위한 라인 스캔 광원의 제어 특성에 관한 연구 (A Study on the Control Characteristics of Line Scan Light Source for Machine Vision Line Scan Camera)

  • 김태화;이천
    • 한국전기전자재료학회논문지
    • /
    • 제34권5호
    • /
    • pp.371-381
    • /
    • 2021
  • A machine vision inspection system consists of a camera, optics, illumination, and image acquisition system. Especially a scanning system has to be made to measure a large inspection area. Therefore, a machine vision line scan camera needs a line scan light source. A line scan light source should have a high light intensity and a uniform intensity distribution. In this paper, an offset calibration and slope calibration methods are introduced to obtain a uniform light intensity profile. Offset calibration method is to remove the deviation of light intensity among channels through adding intensity difference. Slope calibration is to remove variation of light intensity slope according to the control step among channels through multiplying slope difference. We can obtain an improved light intensity profile through applying offset and slope calibration simultaneously. The proposed method can help to obtain clearer image with a high precision in a machine vision inspection system.

형광등과 자연광의 광도에 따른 실내조경식물의 생육반응과 도입 방안 (Growth Responses and Introduction Plan of Interior Landscape Plants under Light Intensity of Fluorescent Light and Sunlight)

  • 최경옥;이상우
    • 한국조경학회지
    • /
    • 제33권4호
    • /
    • pp.119-128
    • /
    • 2005
  • This study was carried out to obtain fundamental information of growth response of interior landscape plants under a fluorescent lighting, a sunlight at indoor. Ficus elastica Roxb. vu. decora Hort, Spathiphyllum 'Clevelandii', Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' and Cordyline terminalis Kunth var. red edge Hort were examined under 100lux, 500lux, 1,000lux and 2,000lux light intensity consisted of fluorescent lighting and sunlight at indoor condition. Result of experiments are as follows; 1. A Ficus elastica Roxb. var. decora Hort plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting in cases of all conditions. 2. A Spathiphyllum 'Clevelandii' showed the best effective adaptations under law intensity among experimental plants. A Spathiphyllum 'Clevelandii', plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status showed the best result under 1,000lux light intensity of fluorescent lighting in cases of all conditions. 3. It need the best high establishment of fluorescent lighting among experimental plants for good plant growth. A Codiaeum variegatum Blume var. pictum Mvell. Arg. 'Exalant' plant growth status was better showed under fluorescent lighting than sunlight. A plant growth status was better showed under high light intensity in case of same light source. A plant growth status showed the best result under 2,000lux light intensity of fluorescent lighting. 4. A Cordyline terminalis Kunth var. red edge Hort plant growth status was better showed under fluorescent lighting than sunlight. but, A plant growth status was better showed under $500lux\sim1,000lux$ than 2,000lux in cases of all intensity of fluorescent lighting. while, A plant growth status was better showed under $1,000lux\sim2,000lux$ in cases of all intensity of sunlight.

섬광에 의하여 사람 눈에 입사되는 광 에너지 (Irradiant Energy into an Eye from a Flash Light)

  • 박승만;한승오
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1225-1230
    • /
    • 2016
  • Since a flash light produces enormous amount of photon energy in short time, not only electro-optic and infrared(EO/IR) systems utilized for Intelligence Surveillance Target Acquisition and reconnaissance(ISTAR) activities but also the people of a combat field can be severely influenced by a high flash light bursting in front of them. The people who bumped into a flash could not escape such enormous amount of photon energy, resulting in being blind temporarily or even permanently. In order to investigate the effect of a high flash source on a human eye, it is essential to know how much photon energy be incident into an eye from the flash source. In this paper, the model of irradiated photon energy to individuals from some flashes is proposed. The proposed irradiated photon energy per unit area of retina is based on taking the situation to be modeled as a simple EO system in front of a flash light. The validity of proposed model was proved by the application of the model to human on the surface of the earth with the well known light source, the Sun. The model of this study can be utilized to simulate the retinal intensity and energy of a flash for various conditions such as the illumination levels, the distance from a flash busting site, luminous intensity and time of a flash.

오차 최소화된 정밀 광삼각법 프로브의 해석 및 설계 (Design & Analysis of an Error-reduced Precision Optical Triangulation Probes)

  • 김경찬;오세백;김종안;김수현;곽윤근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.411-414
    • /
    • 2000
  • Optical Triangulation Probes (OTPs) are widely used for their simple structure. high resolution, and long operating range. However, errors originating from speckle, inclination of the object, source power fluctuation, ambient light, and noise of the detector limit their usability. In this paper, we propose new design criteria for an error-reduced OTP. The light source module for the system consists of an incoherent light source and a multimode optical fiber for eliminating speckle and shaping a Gaussian beam Intensity profile. A diffuse-reflective white copy paper, which is attached to the object, makes the light intensity distribution on the change-coupled device(CCD). Since the peak positions of the intensity distribution are not related to the various error sources, a sub-pixel resolution signal processing algorithm that can detect the peak position makes it possible to construct an error-reduced OTP system

  • PDF

Sirius: The KASI-SNU Optical Intensity Interferometer

  • Oh, Junghwan;Trippe, Sascha;Wagner, Jan;Byun, Do-young
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.58.3-58.3
    • /
    • 2019
  • Optical intensity interferometry, developed in the 1950s, is a simple and inexpensive method for achieving angular resolutions on microarcsecond scales. Its low sensitivity has limited intensity interferometric observations to bright stars so far. Substantial improvements are possible by using avalanche photodiodes (APDs) as light detectors. We present here the results of laboratory measurements with a prototype astronomical intensity interferometer using APDs in continuous ("linear") detection mode - arguably, the first of its kind. We used two interferometer configurations, one with zero baseline and one with variable baseline. Using a superluminous diode as light source, we unambiguously detected Hanbury Brown-Twiss photon-photon correlations at very high significance. From measuring the correlation as function of baseline, we measured the angular diameter of the light source, in analogy to the measurement of the angular diameter of a star. Our results demonstrate the possibility to construct large astronomical intensity interferometers that can address a multitude of astrophysical science cases.

  • PDF

조명용 백색 LED광원의 등기구 형태에 따른 광도 및 기구효율 분석 (The Luminous Intensity and Luminaire Efficiency Analysis of White LED as Luminaire types for General Lighting)

  • 황명근;허창수;서유진
    • 조명전기설비학회논문지
    • /
    • 제18권3호
    • /
    • pp.20-26
    • /
    • 2004
  • 본 논문에서는 조명용 고휘도(HB, high brightness) 백색 LED(light emitting diode)램프의 배열 및 여러 가지 등기구 글로브(globe)의 형태에 따른 광도(luminous intensity)값과 기구효율(luminaire efficiency)을 컴퓨터 시뮬레이션으로 수행하여 비교분석 하였다. 즉, LED의 배열은 가로${\times}$세로(7개${\times}$7개)가 정사각형 형태로 49개를 배열하고, LED 간격은 LED의 발광면 중심부로부터 8.2[mm], 10.0[mm], 15.0[mm]로 각각 3가지로 하였으며, 등기구의 글로브는 LED발광면 중심부에서 30[mm], 50[mm] 떨어진 거리로 구분하였다. 또한 등기구 글로브가 없을 때와 있을때로 구분하여 있을 때에는 글로브 형태를 볼록 원형과 엠보(embossing)형태로 구분하고 엠보는 8.2[mm], 5.0[mm]의 크기에 따른 선택으로 시뮬레이션 27가지로 수행하여 등기구의 글로브 형태에 따른 광도 및 기구효율을 고찰해 봄으로써 앞으로 21세기 디지털조명이라고 일컫는 LED를 사용한 LED 광원(light source) 및 등기구 개발에 많은 도움이 되고자 하였다.

난반사형 광삼각법 변위 센서의 모델링 및 거동 해석 (Modeling and Analysis of Diffuse-type Optical Triangulation Displacement Sensor)

  • 오세백;김경찬;김수현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.43-46
    • /
    • 2000
  • Optical triangulation displacement sensors(0TDSs) are widely used for their simple struchlre, high resolution, and long operating range. However, there are several factors that must be taken into account in order to obtain high accuracy and reliability Measurement errors from inclinations a? an object surface, prohe signal fluctuations generated by speckle effects. power vanation of a light source, electronic noises, and so on. Previous models of OTDSs can not show reasonable behavior as change of surface inclination and shape of light intensity distribution on the detector. In this paper, we propose a new and reasonable modeling for diffise-type OTDSs based on a geometrical optics. To verify propriety of new modeling, we take basic experiments. Shape of light intensity distribution is asymmetric in both simulation result and experimental result. Both simulation result and experimental result show same tendency of light intensity distribution movement as changing surface inclination

  • PDF

A Study on the Optimized Test Condition of Lock-in IR Thermography by Image Processing

  • Cho, Yong-Jin
    • 비파괴검사학회지
    • /
    • 제32권3호
    • /
    • pp.276-283
    • /
    • 2012
  • In this study, it was studies the utilization of LIT(lock-in infrared thermography) which can detect defects in welded parts of ship and offshore structures. Quantitative analysis was used through methods of filtering and texture measurement of image processing techniques to find the optimized experimental condition. We verified reliability in our methods by applying image processing techniques in order to normalize evaluations of comparative images that show phase difference. In addition, low to mid exposure showed good results whereas high exposure did not provide significant results in regards to intensity of light exposure on surface. Lock-in frequency was satisfactory around 0.1 Hz regardless of intensity of light source we had. In addition, having the integration time of thermography camera inversely proportional to intensity of exposed light source during the experiment allowed good outcome of results.

Dynamics of RNA Bacteriophage MS2 Observed with a Long-Lifetime Metal-Ligand Complex

  • Kang, Jung Sook;Yoon, Ji Hye
    • Journal of Photoscience
    • /
    • 제11권1호
    • /
    • pp.35-40
    • /
    • 2004
  • [Ru(2,2'-bipyridine)$_2$(4,4'-dicarboxy-2,2'-bipyridine)]$^{2+}$(RuBDc) is a very photostable probe that possesses favorable photophysical properties including long lifetime, high quantum yield, large Stokes' shift, and highly polarized emission. To evaluate the usefulness of this luminophore (RuBDc) for studying macromolecular dynamics, its intensity and anisotropy decays when conjugated to RNA bacteriophage MS2 were examined using frequency-domain fluorometry with a high-intensity, blue light-emitting diode (LED) as the modulated light source. The intensity decays were best fit by a sum of two exponentials, and the mean intensity decay time was 442.2 ns. The anisotropy decay data showed a single rotational correlation time (2334.9 ns), which is typical for a spherical molecule. The use of RuBDc enabled us to measure the rotational correlation time up to several microseconds. These results indicate that RuBDc can be useful for studying rotational diffusion of biological macromolecules.s.

  • PDF