• 제목/요약/키워드: High frequency voltage injection

검색결과 58건 처리시간 0.031초

Variable-magnitude Voltage Signal Injection for Current Reconstruction in an IPMSM Sensorless Drive with a Single Sensor

  • Im, Jun-Hyuk;Kim, Sang-Il;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1558-1565
    • /
    • 2018
  • Three-phase current is reconstructed from the dc-link current in an AC machine drive with a single current sensor. Switching pattern modification methods, in which the magnitude of the effective voltage vector is secured over its minimum, are investigated to accurately reconstruct the three-phase current. However, the existing methods that modify the switching pattern cause voltage and current distortions that degrade sensorless performance. This paper proposes a variable-magnitude voltage signal injection method based on a high frequency voltage signal injection. The proposed method generates a voltage reference vector that ensures the minimum magnitude of the effective voltage vector by varying the magnitude of the injection signal. This method can realize high quality current reconstruction without switching pattern modification. The proposed method is verified by experiments in a 600W Interior permanent magnet synchronous machine (IPMSM) drive system.

유도전동기 자가 진단 및 상수 추정을 위한 고주파 전류 제어기 구현 (Implementation of High Frequency Current Controller for Self-Sensing Induction Motors)

  • 권영수;석줄기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.144-146
    • /
    • 2007
  • High frequency voltage signal injection have been widely used but they have some problems like over current protection. High frequency current signal injection and feedback control are more stable than voltage signal injection. In this paper, high frequency current controller for self-sensing and parameter estimation of induction motors is presented.

  • PDF

3레벨 인버터로 구동되는 IPMSM의 고주파 주입 센서리스 운전에서 중성점 전압 리플 저감 (Neutral-Point Voltage Ripple Reduction of High Frequency Injection Sensorless Control of IPMSM Fed by a Three-Level Inverter)

  • 조대현;김석민;이교범
    • 전기전자학회논문지
    • /
    • 제24권3호
    • /
    • pp.867-876
    • /
    • 2020
  • 본 논문에서는 3레벨 인버터로 구동되는 IPMSM의 고주파 주입 센서리스 운전에서 중성점 전압 리플 저감을 제안한다. 고주파 전압 주입 기반의 센서리스 제어는 IPMSM의 저속 영역에서 일반적으로 사용하는 센서리스 제어 기법이다. 고주파 전압 주입을 이용한 IPMSM의 센서리스 제어 과정에서 중성점에서의 전압 리플이 증가하는 문제가 발생한다. 중성점에서의 큰 전압 리플은 출력 전류를 왜곡시킬 뿐만 아니라 직류단 커패시터의 수명을 단축시키므로 저감되어야 한다. 본 논문에서 제안하는 기법은 지령 전압에 적절한 값을 보상하여 중성점 전압 리플을 저감하며, 보상값은 지령 전압과 전류를 이용하여 간단히 계산한다. 제안하는 중성점 전압 리플 저감 기법의 타당성은 시뮬레이션을 통해 검증한다.

Sensorless Control of a PMSM at Low Speeds using High Frequency Voltage Injection

  • Yoon Seok-Chae;Kim Jang-Mok
    • Journal of Power Electronics
    • /
    • 제5권1호
    • /
    • pp.11-19
    • /
    • 2005
  • This paper describes the two control techniques to perform the sensorless vector control of a PMSM by injecting the high frequency voltage to the stator terminal. The first technique is the estimation algorithm of the initial rotor position. A PMSM possesses the saliency which produces the ellipse of the stator current when the high frequency voltage is injected into the motor terminal. The major axis angle of the current ellipse gives the rotor position information at a standstill. The second control technique is a sensorless control algorithm that injects the high frequency voltage to the stator terminal in order to estimate the rotor position and speed. The rotor position and speed for sensorless vector control is calculated by appropriate signal processing to extract the position information from the stator current at low speeds or standstill. The proposed sensorless algorithm using the double-band hysteresis controller exhibits excellent reference tracking and increased robustness. Experimental results are presented to verify the feasibility of the proposed control schemes. Speed, position estimation and vector control were carried out on the floating point processor TMS320VC33.

Sensorless Control of IPMSM with a Simplified High-Frequency Square Wave Injection Method

  • Alaei, Ahmadreza;Lee, Dong-Hee;Ahn, Jin-Woo;Saghaeian Nejad, Sayed Morteza
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1515-1527
    • /
    • 2018
  • This paper presents a sensorless speed control of IPMSM (Interior Permanent Magnet Synchronous Motor) using the high-frequency (HF) square wave injection method. In the proposed HF pulsating square wave injection method, injection voltage is applied into the estimated d-axis of rotor and high-frequency induced q-axis current is considered to estimate the rotor position. Conventional square wave injection methods may need complex demodulation process to find rotor position, while in the proposed method, an easy demodulation process based on the rising-falling edge of the injected voltage and carrier induced q-axis current is implemented, which needs less processing time and improves control bandwidth. Unlike some saliency-based sensorless methods, the proposed method uses maximum torque per ampere (MTPA) strategy, instead of zero d-axis command current strategy, to improve control performance. Furthermore, this paper directly uses resultant d-axis current to detect the magnet polarity and eliminates the need to add an extra pulse injection for magnet polarity detection. As experimental results show, the proposed method can quickly find initial rotor position and MTPA strategy helps to improve the control performance. The effectiveness of the proposed method and all theoretical concepts are verified by mathematical equations, simulation, and experimental tests.

이온주입용 정밀고압 발생장치 연구 (A Study of Precision High Voltage Generator for Ion Injection)

  • 유동욱;정창용;백주원;조정구;조기연;김학성;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.158-161
    • /
    • 1998
  • A precision high voltage generator for ion injection is implemented on HFZVS-PSCI (High Frequency Zero-Voltage-Switching Phase-Shift-Controlled Inverter). Some practical aspects of implementing precision high voltage generator with HFZVS-PSCI, such as a HFHV transformer, multiflier, and precision CR divider are discussed. The results show that the generator under the Phase-Shift-Controller has a fast dynamic response, low ripple voltage, and high accuracy.

  • PDF

Electronic Ballast Using a Symmetrical Half-bridge Inverter Operating at Unity-Power-factor and High Efficiency

  • Suryawanshi Hiralal M.;Borghate Vijay B.;Ramteke Manojkumar R.;Thakre Krishna L.
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.330-339
    • /
    • 2006
  • This paper deals with novel electronic ballast based on single-stage power processing topology using a symmetrical half-bridge inverter and current injection circuit. The half-bridge inverter drives the output parallel resonant circuit and injects current through the power factor correction (PFC) circuit. Because of high frequency current injection and high frequency modulated voltage, the proposed circuit maintains the unity power factor (UPF) with low THD even under wide variation in ac input voltage. This circuit needs minimum and lower sized components to achieve the UPF and high efficiency. This leads to an increase in reliability of ballast at low cost. Furthermore, to reduce cost, the electronic ballast is designed for two series-connected fluorescent lamps (FL). The analysis and experimental results are presented for ($2{\times}36$ Watt) fluorescent lamps operating at 50 kHz switching frequency and input line voltage (230 V, 50 Hz).

Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

  • Chaudhari, Madhuri A.;Suryawanshi, Hiralal M.;Kulwal, Abhishek;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.60-73
    • /
    • 2008
  • In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.

구형파 신호 주입을 이용한 IPMSM 센서리스 제어에서 개선된 신호처리 기법 (IPMSM Sensorless Control Using Square-Wave-Type Voltage Injection Method with a Simplified Signal Processing)

  • 박내춘;김상훈
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.225-231
    • /
    • 2013
  • This paper presents an improved signal processing technique in the square-wave-type voltage injection method for IPMSM sensorless drives. Since the sensorless method based on the square-wave voltage injection does not use low-pass filters to get an error signal for estimating rotor position and allows the frequency of the injected voltage signal to be high, the sensorless drive system may achieve an enhanced control bandwidth and reduced acoustic noise. However, this sensorless method still requires low-pass and band-pass filters to extract the fundamental component current and the injected frequency component current from the motor current, respectively. In this paper, these filters are replaced by simple arithmetic operations so that the time delay for estimating the rotor position can be effectively reduced to only one current sampling. Hence, the proposed technique can simplify its whole signal process for the IPMSM sensorless control using the square-wave-type voltage injection. The proposed technique is verified by the experiment on the 800W IPMSM drive system.

Harmonic Analysis of the Effects of Inverter Nonlinearity on the Offline Inductance Identification of PMSMs Using High Frequency Signal Injection

  • Wang, Gaolin;Wang, Ying;Ding, Li;Yang, Lei;Ni, Ronggang;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1567-1576
    • /
    • 2015
  • Offline inductance identification of a permanent magnet synchronous motor (PMSM) is essential for the design of the closed-loop controller and position observer in sensorless vector controlled drives. On the base of the offline inductance identification method combining direct current (DC) offset and high frequency (HF) voltage injection which is fulfilled at standstill, this paper investigates the inverter nonlinearity effects on the inductance identification while considering harmonics in the induced HF current. The negative effects on d-q axis inductance identifications using HF signal injection are analyzed after self-learning of the inverter nonlinearity characteristics. Then, both the voltage error and the harmonic current can be described. In addition, different cases of voltage error distribution with different injection conditions are classified. The effects of inverter nonlinearities on the offline inductance identification using HF injection are validated on a 2.2 kW interior PMSM drive.