• 제목/요약/키워드: High frequency transformer

검색결과 535건 처리시간 0.03초

무접점 풀브리지컨버터의 효율향상을 위한 연구 (A Study for improvement of Efficiency of Full-Bridge Converter using Non-Contact Method)

  • 임성훈;주연홍;이성룡;한병성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.90-93
    • /
    • 2001
  • This paper suggests the circuit topology to transfer AC power using a detachable transformer The circuit topology for AC output load through the magnetic coupling and its principle of operation are described. It can decrease the size of detachable transformer by employing the high-frequency magnetic coupling. It is shown in this paper that the efficiency of noncontact energy transfer system can be improved by applying both the full bridge converter with PFC function to the 1st side of its and the series resonance to the 2nd side to minimize the effect of the leakage inductance.

  • PDF

변압기내 부분방전의 종류에 따른 초음파 신호 특성 (Characteristics of Ultrasonic Signals by Partial Discharge Types)

  • 박현수;박재도;정용기;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1897-1899
    • /
    • 2000
  • This paper describes the frequency characteristics and the number of pulse of ultrasonic signals due to partial discharge occurred at each electrode. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC(b) electrode and void electrode. As a result, the dominant frequency of ultrasonic signals generated by corona in oil and partial discharge in void was hardly changed regardless with the applied voltage, but in case of surface discharge in oil, its dominant frequency moved to low frequency with the applied voltage. The increasing rate of pulse number per second was high in order of the surface discharge in oil, the partial discharge in void, the corona in oil.

  • PDF

전력선 통신 기술을 활용한 변압기 및 전력선로 추적 방법 개발에 관한 연구 (Study about Power Transformer and Lines Tracing Method based on Power Line Communication Technology)

  • 변희정;최상준;손수국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 춘계학술대회
    • /
    • pp.505-508
    • /
    • 2016
  • 도심에서 배전선로는 지중과 가공 선로의 구성, 연가, 건물과 나무로 인한 시야 방해로 추적하기가 어렵다. 이러한 3상 4선식 배전계통에서 특정 수용가가 어떤 변압기 또는 어떤 배전선로로부터 공급되는지를 결정하는 것이 현장의 전기 기술자에게 어려운 문제다. 배전선로의 부하 평형등을 위해 선로의 정확한 추적기술이 필요하다. 본 논문에서는 소전력 고주파 신호를 사용하는 전력선 통신을 활용한 식별 방법을 제안한다. 배전선로에 고주파 전력 신호를 주입하여 분석 한 결과 고주파 신호는 배전선 및 변압기에서 전달을 억제하게 된다. 이러한 제안된 전송제한 방법을 사용하여 변압기도 식별하고 배전선로도 식별하고자 한다. 배전계통에서 전력선 통신 신호의 전달 특성을 분석하기 위한 변압기, 3상 선로, 부하 등에 대한 시뮬레이션 해석 모델을 기술한다. 그리고 시스템은 전력선 통신 모듈을 바탕으로 송수신기로 구성된다. 이론적 개념을 검증하기 위해서 일반 상업용 건물에서 실험이 행하여진다. 또한 MATLAB 시뮬링크를 사용하여 개념에 대한 이해를 위한 시뮬레이션이 수행된다.

  • PDF

Design of a 2.4-GHz Fully Differential Zero-IF CMOS Receiver Employing a Novel Hybrid Balun for Wireless Sensor Network

  • Chang, Shin-Il;Park, Ju-Bong;Won, Kwang-Ho;Shin, Hyun-Chol
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권2호
    • /
    • pp.143-149
    • /
    • 2008
  • A novel compact model for a five-port transformer balun is proposed for the efficient circuit design of hybrid balun. Compared to the conventional model, the proposed model provides much faster computation time and more reasonable values for the extracted parameters. The hybrid balun, realized in $0.18\;{\mu}m$ CMOS, achieves 2.8 dB higher gain and 1.9 dB lower noise figure than its passive counterpart only at a current consumption of 0.67 mA from 1.2 V supply. By employing the hybrid balun, a differential zero-IF receiver is designed in $0.18\;{\mu}m$ CMOS for IEEE 802.15.4 ZigBee applications. It is composed of a differential cascode LNA, passive mixers, and active RC filters. Comparative investigations on the three receiver designs, each employing the hybrid balun, a simple transformer balun, and an ideal balun, clearly demonstrate the advantages of the hybrid balun in fully differential CMOS RF receivers. The simulated results of the receiver with the hybrid balun show 33 dB of conversion gain, 4.2 dB of noise figure with 20 kHz of 1/f noise corner frequency, and -17.5 dBm of IIP3 at a current consumption of 5 mA from 1.8 V supply.

IGBT 인버터제어 TIG용접기 성능개선에 관한 연구 (A Study on the Performance-Improvement of TIG Welder with IGBT Inverter System.)

  • 이정호;김재문;김연충;원충연;김규식;김영렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2155-2158
    • /
    • 1997
  • This paper describes the performance improvement of dc TIG (Tungsten Inert Gas) welder. The TIG welder consists of single phase full bridge IGBT inverter which incorporates the high frequency transformer, the boost converter for improving the input power factor, and the arc start system. The arc will be generated without fail even when the extension cable between the torch and the power source is 100m long. In addition, the arc start system with a short dc output voltage will generate less EMI noise than the traditional arc start system with a high frequency output voltage. To demonstrate the practical significance of the proposed methods, some simulation studies are presented.

  • PDF

ZVS 기법을 사용한 위상제어 PWM FB DC/DC 컨버터 (Phase-shifted PWM FB DC/DC Converter with ZVS Method)

  • 김성철;권순걸;계문호;조기연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.392-394
    • /
    • 1996
  • This paper is to describe how to apply the Phase-shifted Full Bridge 100kHz high frequency soft-switching PWM method to 48[V], 200[A] DC/DC converter. The soft-switching is achieved from light load to full load by using phase-shifted zero voltage switching method with additional capacitors besides the MOSPET's of the right leg even though the leakage inductance of high frequency transformer is designed small. This method can reduce the switching tosses, EMI problems, and increase the effective duty. Also, this paper includes the simulation, analysis, and experiment results of the DC/DC converter unit.

  • PDF

High-Frequency Soft-Switching PWM DC-DC Power Converter for Low Voltage Large Current Applications

  • Muraoka Hidekazu;Sakamoto Kenya;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.198-202
    • /
    • 2001
  • This paper presents a novel prototype version of ZCS-PWM forward DC-DC power converter using power MOSFETs which is designed for application specific low voltage large current conversion operation. The soft-switching forward power converter with a high frequency isolated transformer link which can efficiency operate over wide load ranges under two conditions of ZCS as well as active voltage clamped switching is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

TDR을 이용한 극초단파 대역에서 사용 절연유의 유전율과 전파속도 측정 (Measurement on the permittivity and propagation velocity of used insulation oil at UHF Band using time domain reflectometry)

  • 구선근;주형준;박기준;한기선;윤진열
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2011-2014
    • /
    • 2008
  • We measured the permittivity and electromagnetic wave propagation velocity of used insulation oil with wide frequency range including ultra-high frequency by time domain reflectometry. The permittivity or propagation velocity is essential for locating discharge faults of oil filled power transformer. We derived 2.21 as a permittivity and $2.03{\times}10^8 m/s$ as a velocity from the measurement of pulse travelling time along a coaxial line filled with used insulation oil or air. The permittivity measurement system we designed shows high measurement accuracy and the convenience for field use.

원자력발전소 고압케이블 열화진단에 관한 연구 (Study on Diagnosis of High Voltage Cables for Nuclear Power Plant)

  • 하체웅;주광호;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2061-2062
    • /
    • 2011
  • 국내 원자력발전소에 설치되어 있는 고압케이블은 장기운전에 따라 열화진단 및 유지보수의 필요성이 증대되고 있다. 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에 설치되어 있는 13.8kV급 고압케이블의 건전성을 확인하기 위하여 원자력발전소 계획예방정비 중 열화진단을 수행한 결과를 소개하고 있다. 특히 미국 NRC(Nuclear Regulatory Commission)에서는 케이블 진단 기법 11가지를 권고하고 있는데 본 논문에서는 그 중 국내 원자력발전소에 적용이 가능한 최신 케이블 진단 기술인 HFCT(High Frequency Current Transformer)를 이용한 부분방전(Partial Discharge ; PD) 측정, VLF(Very Low Frequency) 장치를 이용한 $Tan{\delta}$ 측정 및 열화상카메라를 이용한 케이블 온도 측정을 사용하여 고압 케이블 진단을 실시하였고, 그 결과를 서술하였다.

  • PDF

VLF 및 HFCT-PD 장비를 이용한 원자력발전소 고압케이블 진단 방법 (Diagnostic Method of High Voltage Cable for Nuclear Power Plants using VLF and HFCT-PD Devices)

  • 하체웅;주광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2067-2068
    • /
    • 2011
  • 국내 원자력발전소에 설치되어 있는 고압케이블은 장기 운전에 따라 열화진단 및 유지보수의 필요성이 증대되고 있으며, 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에서 경년열화로 진단되어 철거된 케이블을 수거하여 VLF(Very Low Frequency) 장비를 사용하여 가압을 한 후 HFCT(High Frequency Current Transformer)를 이용한 부분방전(Partial Discharge ; PD) 측정을 수행하여 향후 원자력발전소 계획예방정비 시 케이블을 대상으로 Off-line 부분 방전 진단이 가능한지를 검토하였고, 그 결과를 기술하였다.

  • PDF