• 제목/요약/키워드: High flux system

검색결과 748건 처리시간 0.026초

ABSORBED HEAT-FLUX METHOD FOR GROUND SIMULATION OF ON-ORBIT THERMAL ENVIRONMENT OF SATELLITE

  • Kim, Jeong-Soo;Chang, Young-Keun
    • Journal of Astronomy and Space Sciences
    • /
    • 제16권2호
    • /
    • pp.177-190
    • /
    • 1999
  • An absorbed heat-flux method for ground simulation of on-orbit thermal environment of satellite is addressed in this paper. For satellite ground test, high vacuum and extremely low temperature of deep space are achieved by space simulation chamber, while spatial environmental heating is simulated by employing the absorbed heat-flux method. The methodology is explained in detail with test requirement and setup implemented on a satellite. Developed heat-load control system is presented with an adjusted PID-control logic and the system schematic realized is shown. A practical and successful application of the heat simulation method to KOMPSAT(Korea Multi-purpose Satellite)thermal environmental test is demonstrated, finally.

  • PDF

釉上彩色料에 關한 硏究 (Studies on Overglaze Stain)

  • 이종근;박용완
    • 대한화학회지
    • /
    • 제4권1호
    • /
    • pp.27-37
    • /
    • 1957
  • High-fire stain is influenced by the conditions of glaze, firing atmosphere, etc. On the contrary, low fire stain is not influenced by those conditions but obtainable in arbitrary colors and it is indispensable for pottery decoration. It is difficult for us to study into the color in the sphere of result publication method and expression of color. Looking over the literature on this subject, I have been confronted with much difficulties, accordingly, I made a basic and systematic experiment as to six low-firing stains (blue, green, blue-green, brown black and yellow) and made it proper to be applied in these studies. On pigment, I confirmed the influence of the assistant coloring matter by mixing up the coloring matter and the assistant coloring matter in various proportions. On flux, I measured the melting point by making PbO-$SiO_2$ system and PbO-$B_2O_3-SiO_2$ system and decided the range of usage. Also I checked the coloring by making the pigment on laze with pigment and flux manufactured, and concluded the pigment and flux adaptation to it.

  • PDF

자연냉매 프로판을 이용한 수평세관 증발기의 열전달 특성에 관한 연구 (Study on Heat Transfer Characteristics of Evaporator with Horizontal Small Diameter Tubes using Natural Refrigerant Propane)

  • 구학근
    • 동력기계공학회지
    • /
    • 제14권4호
    • /
    • pp.11-16
    • /
    • 2010
  • The evaporation heat transfer characteristics of propane(R-290) in horizontal small diameter tubes were investigated experimentally. The test tubes have inner diameters of 1 mm and 4 mm. Local heat transfer coefficients were measured at heat fluxes of 12, $24\;kW/m^2$, mass fluxes of 150, $300\;kg/m^2s$, and evaporation temperature of $15^{\circ}C$. The experimental results showed that the evaporation heat transfer coefficient of R-290 has an effect on heat flux, mass flux, tube diameter, and vapor quality. The evaporation heat transfer of R-290 has an influenced on nucleate boiling at low quality and convective boiling at high quality. The evaporation heat transfer coefficient of R-290 increases with decreasing inner tube diameter. And the evaporation heat transfer coefficient of R-290 is about 1~3 times higher than that of R-134a.

The application of hydrated fine MgO particles for flux pinning center in the HTS-BSCCO system

  • 김성환;김철진;정준기;박성창;유재무
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.188-192
    • /
    • 2002
  • To introduce flux pinning center in HTS-BSCCO system, nano-size MgO particles were uniformly distributed within the Bi-2223 grain by partial hydration of MgO. The existing method MgO doped Bi-2223 used nato-size MgO powders, which resulted in agglomeration during mixing or grain growth during heat-treatment due to the high surface energy of the fine particles. By hydration of the MgO surface, the agglomeration of the MgO powders was avoided and the size of remaining MgO core was controlled by changing hydration medium and time. The thin film obtained by spin coating of (Bi_$1.8/Pb_{0.4}$)$Sr_2$$_{Ca}$$2.2/Cu_3$ $O_{y}$ nitrate solution mixed with hydrated MgO showed the even distribution of nano-size MgO particles in the Bi-2212 grains.s.s.

  • PDF

정적연소기에서 순간온도를 이용한 열유속에 관한 연구 (Study on the Heat Flux Using Instantaneous Temperature in the Constant Volume Combustion Chamber)

  • 이치우;김지훈;하종률;김시범
    • 한국자동차공학회논문집
    • /
    • 제9권4호
    • /
    • pp.103-111
    • /
    • 2001
  • In the present study, the internal combustion engine tends to high performance, fuel economy, small-sized. Therefore, it is necessary to solve the problems on thermal load, abnormal combustion, etc in the engine. Thin film instantaneous temperature probe was made, and the measuring system was established. The instantaneous surface temperatures in the constant volume combustion chamber were measured with this system and the heat flux was obtained by Fourier analysis. Maximum instantaneous temperatures were obtained after 55∼60ms from ignition and they increased as equivalence ratio and varied differently as the position of probe. Total heat loss during combustion time was affected by the equivalence ratio and differed widely as the position of probe.

  • PDF

추력밀도 향상을 위한 Double type 횡자속 전동기에 대한 연구 (A Study of Double type Transverse Flux Linear Motor for Improvement of Power Density)

  • 이지영;홍정표;장정환;강도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1052-1054
    • /
    • 2004
  • This paper deals with a Double type Transverse Flux Linear Motor(TFLM) which can be applied to high power system. This type can reduce overall system volume because of the configuration which has double flux path of prototype per phase, and less number of phase and turns. This TFLM is based on permanent magnet excitation, and the pole shape is designed to reduce attraction force between stator and mover poles. In the paper, the basic configuration of double type and the principle of movement are introduced. After performing the characteristic analysis by 3-dimensional equivalent magnetic circuit network, the results are discussed.

  • PDF

Water Treatment of High Turbid Source by Tubular Ceramic Microfiltration with Periodic Water-back-flushing System

  • Lee, Hyuk-Chan;Park, Jin-Yong
    • Korean Membrane Journal
    • /
    • 제9권1호
    • /
    • pp.12-17
    • /
    • 2007
  • We performed periodic water-back-flushing using permeate water to minimize membrane fouling to enhance permeate flux in tubular ceramic microfiltration system for water treatment of high turbid source. The filtration time (FT) = 2 min with periodic 6 sec water-back-flushing showed the highest value of dimensionless permeate flux ($J/J_o$), and the lowest value of resistance of membrane fouling ($R_f$), and we acquired the highest total permeate volume $(V_T)\;=\;6.805L$. Also in the result of BT effect at fixed FT = 10 min and BT (back-flushing time) = 20 sec showed the lowest value of $R_f$ and the highest value of $J/J_o$, and we could obtain the highest $V_T\;=\;6.660\;L$. Consequently, FT = 2 min and BT = 6 sec could be the optimal condition in water treatment of high turbid source above 10 NTU. However, FT = 10 min and BT = 20 sec was superior to reduce operating costs because of lower back-flushing frequency. Then the average quality of water treated by our tubular ceramic MF system was turbidity of 0.07 NTU, $COD_{Mn}$ of 1.86 mg/L and $NH_3-N$ of 0.007 mg/L.

습식비중분리시스템에서 생산된 고품질 순환모래를 사용한 모르타르의 품질평가에 관한 실험적 연구 (An Experimental Study on the Quality Estimation of the Mortar using High-Quality Recycled Sand Producted from the Manufacturing System by Wet Gravity Separation)

  • 이지환;노형남;이종석;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2008년도 춘계 학술논문 발표대회
    • /
    • pp.103-107
    • /
    • 2008
  • This study was to execute the experiment for analyzing the quality characteristics of mortar by type of recycled sand by using the recycled sand produced by the manufacturing system by wet gravity separation in order to develop the removal device of impurities for the production of high-quality recycled sand. As a result, this study has sown that the mortar using the high-quality recycled sand through the manufacturing system by wet gravity separation in the fluidity property, strength property, and shrinkage property largely, compared with the mortar using low-quality recycled sand that not passed the device of sand flux. There was a tendency similar to the plane mortar. In conclusion, it was considered as various quality performances of the recycled sand were improved through the production stage of prototype.

  • PDF

히터트리거를 이용한 고온초전도전원장치의 제작 및 특성 실험에 관한 연구 (The Fabrication and Characteristic Experiment of a Heater-Trigger type High-Tc Superconducting Power Supply)

  • 윤용수;김호민;추용;이창열;고태국;한태수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권9호
    • /
    • pp.484-489
    • /
    • 1999
  • This paper deals with the design and fabrication of a heater-trigger type high-Tc superconducting power supply system, and characteristics have been analyzed through experiments. The high-Tc superconducting power supply consists of two heater trigger and electric magnet, and YBCO superconducting bulk. In this experiment, 0.6T class magnet and dc 2.3A heater current are used, and the current-pumping characteristics have been analyzed with computer aided sequence control system. Hall sensors are installed on the YBCO bulk and in the center of iron core in order to analyze the effect of the flux-pumping on the system with when magnet flux changes its value. In this experiment, maximum pumping-current has been achieved to about 6.6 amps.

  • PDF

두 트리거 전류를 갖는 자속구속형 초전도한류기의 고장전류 크기에 따른 초전도 모듈의 전력부담 분석 (Analysis on Power Burden of HTSC Module due to Fault Current's Amplitude of a Flux-Lock Type SFCL with Two Triggering Currents)

  • 한태희;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제29권7호
    • /
    • pp.424-428
    • /
    • 2016
  • In this paper, the power burden of High-TC superconducting (HTSC) module comprising the flux-lock type superconducting fault current limiter (SFCL) with two triggering currents during the fault period was analyzed. The short-circuit tests for the simulated power system with the SFCL in the different fault positions, which were expected to affect the amplitude of the fault current, were carried out. Through the comparative analysis on the power burden of the HTSC modules, the proposed flux-lock type SFCL was confirmed to be effective to divide into two power burdens according to the amplitude of the fault currents.