• Title/Summary/Keyword: High efficient control

Search Result 1,309, Processing Time 0.032 seconds

Design of the power generator system for photovoltaic modules

  • Park, Sung-Joon
    • Journal of IKEEE
    • /
    • v.12 no.4
    • /
    • pp.239-245
    • /
    • 2008
  • In this paper, a dc-dc power converter scheme with the FPGA based technology is proposed to apply for solar power system which has many features such as the good waveform, high efficiency, low switching losses, and low acoustic noises. The circuit configuration is designed by the conventional control type converter circuit using the isolated dc power supply. This new scheme can be more widely used for industrial power conversion system and many other purposes. Also, I proposed an efficient photovoltaic power interface circuit incorporated with a FPGA based DC-DC converter and a sine-pwm control method full-bridge inverter. The FPGA based DC-DC converter operates at high switching frequency to make the output current a sine wave, whereas the full-bridge inverter operates at low switching frequency which is determined by the ac frequency. As a result, we can get a 1.72% low THD in present state using linear control method. Moreover, we can use stepping control method, we can obtain the switching losses by Sp measured as 0.53W. This paper presents the design of a single-phase photovoltaic inverter model and the simulation of its performance.

  • PDF

PV System using HIL System (Hardware-In-the-Loop 시스템을 이용한 태양광 시스템 연구)

  • Kim, Ju-Yeop;Choy, Ick;Kim, Byeong-Man
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.665-665
    • /
    • 2005
  • The existing DSP for utility interactive photovoltaic generation system control generally uses floating point process type. Because it is easy to use for number crunching, however, it is too late and too expensive. Fixed point process DSP TMS320F2812, has high control speed and is rather inexpensive. A very complicated real system can be simulated using hardware-in-the-loop (HIL) system in a virtual environment Therefore, HIL system can speed up research and development process with a little effort. Also current DSP for utility interactive photovoltaic generation system adopts floating point process type, which is easy to use for number crunching. However, fixed point process DSF, TMS320F2812, has high control speed and is rather inexpensive. This paper presents more efficient method for MPPT control using TMS320F2812 along with HIL System.

  • PDF

PWM Drive System Realization for Speed Control of TFM (횡축형 전동기의 속도제어를 위한 PWM 구동 드라이브 구현)

  • Lim, Tae-Yun;Kim, Dong-Hee;Kim, Jong-Moo;Jeong, Yeon-Ho;Kang, Do-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1221-1223
    • /
    • 2000
  • TFM(Transeverse Flux Motor) is a switched reluctance motor with a new structure of novel design concept based on the high efficiency and power density compare to induction motor used on wide industrial field. To apply TFM to various industrial field instead of induction motor, an efficient converter drive system for speed and current control in TFM is required. This paper realized PWM asymmetric converter drive control system for TFM using IGBT and DSP. To certificate the high power and efficiency drive characteristics of realized PWM converter drive control system. simulation was excecuted on speed command and load variation using Matlab/Simulink.

  • PDF

A Novel Pulse Density Modulated High Frequency Inverter for Streamer Reactor (스트리머 발생을 위한 새로운 PDM 고주파 인버터)

  • Kim, J.Y.;Mun, S.P.;Suh, K.Y.;Lee, H.W.;Jung, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.223-225
    • /
    • 2005
  • This paper presents a novel prototype of a current source resonant inverter using insulated gate bipolar transistors for driving a streamer reactor, streamer generation technology has been recognized as one of the best methods for water treatment, disinfection, industrial wastes utilization, and so on. However, some technological difficulties related to efficient streamer production have been significant problems restricting streamer usage in the industrial plants. Introduced in this paper is a pulse density modulated high frequency inverter for a plasma generate, which is developed with the aim to improve power conversion and control characteristics of the streamer reactor by using advances in power electronic technology. The developed system implements the feedforward control-based pulse density modulation control scheme with pulse width modulation feedback control strategy to compensate temperature and other environmental influences on streamer discharge.

  • PDF

The New Active Voltage Clamp ZVS-PWM Resonant High-frequency Inverter (새로운 액티브 전압 클램프 ZVS-PWM 공진 고주파 인버터)

  • Ahn, Yong-Wie;Kim, Hong-Shin;Mun, Sang-Pil;Woo, Kyung-Il;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.188-193
    • /
    • 2017
  • In this paper, a ZVS-PWM high-frequency inverter with a PWM control function is applied to commercial system 220[Vrms], and a resonator type ZVS-PWM high-frequency inverter circuit with a fixed-two methods were proposed. The parameters of the transformer model equivalent circuit of a copier fixing device, which is an essential element in the parameter optimization of the proposed circuit, are obtained by using a high-frequency amplifier and its frequency characteristics are described. The proposed method compared to the existing single-ended ZVS-PFM high frequency inverter can suppress the voltage and current peak value of the power semiconductor switching device and reduce the switching loss. The efficiency of the proposed method itself is 98[%] at rated power output. Also, the efficiency of 96[%] can be obtained even at low output, so that the proposed high frequency inverter is very efficient inverter. The total efficiency from the commercial AC input to the inverter output is 93[%] at rated, which is considered efficient for use in copying machines. In addition, the diode bridge loss accounts for the largest portion of the overall system efficiency distribution. On the other hand, the nonparallel filter has a very low loss.

High Performance Control of Switched Reluctance Motor Drive System for Automobiles by C-dump Converter (C-dump Converter에 의한 차량용 스위치드 릴럭턴스 전동기 구동 시스템의 고성능제어)

  • Kim D.K.;Yoon Y.H.;Lee T.W.;Won C.Y.;Kim Y.R.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.860-865
    • /
    • 2003
  • Recently, SRMs are used in automobiles for power assistant steering, accessory motion control and traction drives. Especially in the motion control and traction drives, safety and efficiency are of paramount important. The paper describes the essential elements, faced in designing and constructing drive circuits for a switched reluctance motor for automobiles. These converters will be referred to as energy efficient C-dump converter and modified C-dump converter Energy efficient C-dump converter topology eliminate all the disadvantages of the C-dump converter without sacrificing its attractive features, and also provide some additional advantages that have lower number of power devices, full regenerative capability, free-wheeling in chopping or PWM mode, simple control strategy, and faster demagnetization during commutation. The experiments are peformed to verify the capability of proposed control method on 6/4 salient type SRM.

  • PDF

New Control System Aspects for Supporting Complex Data and High Performance System

  • Yoo, Dae-Seung;Tan, Vu Van;Yi, Myeong-Jae
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.4
    • /
    • pp.394-411
    • /
    • 2008
  • The data in automation and control systems can be achieved not only from different field devices but also from different OPC (OLE for Process Control) servers. However, current OPC clients can only read and decode the simple data from OPC servers. They will have some problems to acquire structured data and exchange the structured data. In addition to the large network control systems, the OPC clients can read, write, and subscribe to thousands of data points from/to OPC servers. Due to that, the most important factor for building a high performance and scalable industrial control system is the ability to transfer the process data between server and client in the most efficient and fastest way. In order to solve these problems, we propose a means to implement the OPC DA (Data Access) server supporting the OPC complex data, so that the OPC DA clients are able to read and decode any type of data from OPC servers. We also propose a method for caching the process data in large industrial control systems to overcome the limitation of performance of the pure OPC DA system. The performance analysis and discussion indicate that the proposed system has an acceptable performance and is feasible in order for applying to real-time industrial systems today.

Application of MR damper for Vibration Control of Adjacent Buildings (인접건축물의 진동제어를 위한 MR감쇠기의 적용)

  • Kim, Gee-Cheol;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.12 no.4
    • /
    • pp.99-108
    • /
    • 2012
  • In recently, sky-bridge are often applied to high-rised adjacent buildings for pedestrian bridge. the seisnic response control of adjacent buildings have been studied and magneto-rheological(MR) fluid dampers have been applied to seismic response control. In this study, vibration control effect of the MR damper connected adjacent buildings has been investigated. Adjacent building structures with different natural frequencies were used as example structures. Two typed of control methods, displacement based or velocity based, are applied to determinate control force of MR damper. In this numerical analysis, it has been shown that displacement-based control algorithm is more effective than velocity-based control algorithm for seismic response control of adjacent buildings. And, when displacement-based control method is applied to control of adjacent buildings, the control of building occurred large displacement is more efficient in reducing the seismic response.

Present Status and Prospect of Weed Control in Korea (우리나라의 잡초방제(雜草防除) 현황(現況)과 전망(展望))

  • Ahn, Soo-Bong
    • Korean Journal of Weed Science
    • /
    • v.1 no.1
    • /
    • pp.5-14
    • /
    • 1981
  • Weed is one of the problems in the crop land as well as in uncultivated land, raising the farm management costs. Therefore, the weed control is essential for effective agricultural management. The cost for weed control in Korea occupies on the average 27.6% of the total labor cost required. Agricultural policies since 1960 were transferring from yield increase due to land productivities to increase of income due to labor productivities. Therefore, the weed control by hand is also changed to weed control by chemicals. The weed control by chemicals has also brought about some side-effects and needs better, improved weed control methods. The present weed control situation and related problems were studied to present new approaches for agricultural development in the future. There were 458 species of weeds in 82 families which were growing in the crop land. The weeds to control, however, are 12 in paddy field and 9 in upland. So far weeds in paddy field are well under control, while weeds in upland are poorly controlled due to change in chemical efficiency and chemical damage in the upland. The administration, research and extension work for the efficient use of agricultural chemicals have been done by various institutions, such as Office of Rural Development, Office of Forestry, and chemical companies. The courses for agricultural chemicals were offered in the agricultural colleges. However, the efficiency of chemicals could not be maximized due to the poor relationships among related institutes. The newly established Agricultural Chemical Research Center at the Office of Rural Development and the Korean Weed Science Association are expected to contribute toward improving weed control in Korea. The Korean agriculture in the future will eventually be mechanized and the varieties resistant to high nitrogen application and to high plant density will be required for high yields. The rice will be transplanted earlier and the whole growing period will be extended. The application of organic matter will be increased for increasing soil fertility, and the use of agricultural chemicals will be continued. Under such a condition, the studies on the weed occurrence and its integrated control measures will be needed. Also weed controls in the newly exclaimed land, crop varieties, horticultural varieties, forage crops, and forests are also needed to study. Basic and practical researches for the weed control to improve the labor productivity will be also needed. In order to meet the all requirements for efficient weed control, weed control systems including all the academics, research and extension workers, administratives, farmers and companies should be established. Also securing researchers and education of personnels are pre-required and research funds for the chemical studies should be provided efficiently and timely.

  • PDF

A Study of Transparent Liquid Crystal Gel with High Oil Content from Fatty Acid Soap (지방산 솝을 이용한 고오일 함유 투명젤 생성에 관한 연구)

  • Lee, Jung-No;Kim, Hyuk-Hwa;Yu, Kang-Yeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.431-437
    • /
    • 2011
  • Transparent liquid crystal gels with high oil content by fatty acid soap were investigated. The solubilization efficiency of the mineral oil was dependent on the process. The process of dropping water part into the solution of oil and surfactant was more efficient than the process of dropping water part into the surfactant solution and after that dropping oil. The fatty acid soap could not solubilize the high oil content, but under the certain range, addition of CDE (Coconut Diethanolamide), Arlacel 165 (Glyceryl Stearate/PEG-100 Stearate) and cetostearyl alcohol helped solubilize the high content oil. Also, the glycerin and water content had influence on the solubilization. Especially, higher oil content gel showed elastic feature.