• Title/Summary/Keyword: High efficiency operation

Search Result 1,907, Processing Time 0.035 seconds

Efficiency Analysis of Port Companies in China Using DEA and the Malmquist Method

  • He, Wenjun;Ma, Hye-Min;Yeo, Gi-Tae
    • Journal of Navigation and Port Research
    • /
    • v.41 no.5
    • /
    • pp.319-328
    • /
    • 2017
  • The efficiency of port operations is an important indicator of port development. Moreover, there is excess handling capacity in Chinese ports, which results in a slower speed of development. Under the detrimental environment of the international shipping market, it is necessary to improve the operation efficiency of ports for long-term development. This paper provides an assessment of the competitiveness of Chinese seaport companies using the Boston Consulting Group's matrix, and efficiency measurements using a data envelopment analysis and the Malmquist method. This analysis showed that highly efficient companies reformed their development strategies, which should be a solution considered by less efficient companies, such as Shenzhen Yan Tian Port Holdings Co., Ltd.. Although, having high throughput should be reformed in the investment structure. This research will assist port companies in gaining effective operating experience, and governments in establishing strategic planning to enhance the efficiency of port development.

Analysis of RCSTP Wastewater Characteristics and Installed Treatment Process in Bong-Hwa Gun (봉화군에 도입된 마을하수도 하수 특성 및 처리 공법 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.453-460
    • /
    • 2013
  • Rural area sewage distribution rate is 40 % less than urban area. Previous research results announced that one of the reason in water resource pollution was caused of low rural area sewage distribution rate. Analysis on operation result of 11 RCSTP in Bong-hwa area which is located at the upper region of An-dong Dam and Im-ha Dam. Based on operation result, an analysis on characteristics of wastewater in Bong-hwa and treatment efficiency of installed treatment process was conducted. The wastewater influent of Bong-hwa contained high organic matter and nutrient than those of urban area. Treatment process showed totally stable treatment efficiency. But, The treatment efficiency for nutrient showed high fluctuation. This result means which is need to operation condition control of nutrient treatment when operating RCSTP.

Optimal Microgrid Operation Considering Fuel Cell and Combined Heat and Power Generation (연료전지와 열병합 발전을 고려한 마이크로그리드의 최적 운용)

  • Lee, Ji-Hye;Lee, Byung Ha
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.596-603
    • /
    • 2013
  • The increase of distributed power generation is closely related to interest in microgird including renuable energy sources such as photovoltaic (PV) systems and fuel cell. By the growing interest of microgrid all over the world, many studies on microgrid operation are being carried out. Especially operation technique which is core technology of microgrid is to supply heat and electricity energy simultaneously. Optimal microgrid scheduling can be established by considering CHP (Combined Heat and Power) generation because it produce both heat and electricity energy and its total efficiency is high. For this reason, CHP generation in microgrid is being spotlighted. In the near future, wide application of microgrid is also anticipated. This paper proposes a mathematical model for optimal operation of microgrid considering both heat and power. To validate the proposed model, the case study is performed and its results are analyzed.

Constitution and Operation of the 25 kW Molten Carbonate Fuel Cell Power Generation System for Power Utility (25 kW급 전력사업용 MCFC 발전시스템 구성 및 운전평가)

  • Lim, Hee-Chun;Ahn, Kyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.687-689
    • /
    • 2000
  • Molten Carbonate Fuel Cell (MCFC) with high electrical efficiency and low environmental effect has been developed for the commercial application of power generation fields. Recently we have built a 25 kW molten carbonate fuel cell power generation system and tested it. The MCFC system is composed of diverse peripheral units such as reformer, pre-heater, water purifier. electrical loader, gas supplier, and recycling systems. The stack itself was made of 40 cells of $6.000 cm^2$ area each. The stack showed an output of 28.6 kW power and a reliable performance at atmospheric operation. while in pressurized operation the stack showed an output 25.6 kW lower than the atmospheric operation. The reason of lower performance of pressurized operation was caused from a gas cross over shown in few cells in the stack.

  • PDF

The Optimal Scheduling and Operational characteristics on Battery Energy Storage System (전지전력저장설비의 최적운용 및 운전특성에 관한 연구)

  • Song, Kil-Yeong;Oh, Kwang-Hae;Kim, Yong-Ha;Rho, Dae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.102-105
    • /
    • 1993
  • The objective of this study is to solve the operation scheduling problem of plural battery energy storage systems (BESS), and to find useful intonation from its result. Unlike conventional energy storage system, BESS has on hardware characteristics such as high efficiency, fast-acting response and operational loss. Considering rate constraints of thermal unit power as well as hardware characteristics of BESS, the operation scheduling has an intricated problem. In order to solve this optimization problem, we use successive approximations dynamic programming. In two types of operation, the proposed algorithm is applied to test system. one is daily optimal operation, the other weekly optimal operation.

  • PDF

Design of a Dual Band High PAE Power Amplifier using Single FET and CRLH-TL (Single FET와 CRLH 전송선을 이용한 이중대역 고효율 전력증폭기 설계)

  • Kim, Seon-Sook;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.2
    • /
    • pp.56-61
    • /
    • 2010
  • In this paper, high efficient power amplifier with dual band has been realized. Dual band power amplifier have used modify stub matching for single FET, center frequency 2.14GHz and 5.2GHz respectively. The dual-band operation of the CRLH TL is achieved by the frequency offset and the nonlinear phase slope of the CRLH TL for the matching network of the power amplifier. Because the control of the all harmonic components is very difficult m dual-band, we have managed only the second- and third-harmonics to obtain the high efficiency with the CRLH TL in dual-band. Dual-band characteristics in the output has to balance. Two operating frequencies are chosen at 2.14 GHz and 5.2 GHz in this work. The measured results show that the output power of 28.56 dBm and 29 dBm was obtained at 2.14 GHz and 5.2 GHz, respectively. At this point, we have obtained the power-added efficiency (PAE) of 65.824 % and 69.86 % at two operation frequencies, respectively.

A Study on the Power Amplifier with High Efficiency for IMT-2000 (고효율 특성을 갖는 IMT-2000용 전력 증폭기 설계에 관한 연구)

  • 조병근;이상원;홍신남
    • Proceedings of the IEEK Conference
    • /
    • 2000.11a
    • /
    • pp.325-328
    • /
    • 2000
  • This paper has been studied a rower amplifier for IMT-2000 handset. Circuit design is performed and optimized by using HP ADS RF software. Designed amplifier consist of 2 stage, has 25㏈ gain, over 27㏈m output power and about 40% power efficiency. Power amplifier operation frequency range is 1955${\pm}$70MHz. Mask layout of the designed Amplifier consisting of 4 mask. The measured results of these values are satisfying the specification of IMT-2000 handset.

  • PDF

Evaluation of Pre-estimation Model to the Inprocess Surface Roughness for Grinding Operations

  • Kim, Gun-Hoi
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.3 no.4
    • /
    • pp.24-30
    • /
    • 2002
  • In grinding operations, one of the most important problems is to increase efficiency of process. In order to achieve this purpose, it is necessary to administer the tool lift of grinding wheel and to optimize grinding conditions. Frequently dressing result in lowering the process efficiency remarkably and makes production cost high. On the other hand, grinding with a worn wheel causes the workpiece surface roughness to increase and often results in the occurrence of such troubles as chatter vibration and homing.

Wide Input Range Active Clamp Forward Converter Design (넓은 입력전압 능동 클램프 포워드 컨버터 설계)

  • Chun, Moon-Il;Kim, Chang-Sun;Ma, Byung-In
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.64-65
    • /
    • 2008
  • The topology of active clamp forward converter provides ZVS characteristic and also the stress of voltage and current is smaller than that of the conventional forward converters. The benefits of this technique include a higher efficiency at a high switching frequency, lower EMI/RFI. In this paper, the active clamp forward converter is designed for operation in wide range voltage and has 19.5V/120W ratings with efficiency more than 90%.

  • PDF

Professional Engineer Yard: Understanding of Engine Variable Valve Train Technology and Trend (기술사마당: 엔진 가변 밸브 기구 이해 및 개발동향)

  • Kim, Do-Wan
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.4
    • /
    • pp.39-43
    • /
    • 2011
  • To cope with recent high gas prices and global warming phenomenon, the latest gasoline engine technologies are focusing on direction injection, downsizing by turbo charging, variable compression ratio, controlled auto Ignition to enhance fuel efficiency and satisfy emission regulations. The variable valve train technology will be a basement for these innovative technologies in internal combustion engines and is supposed to play a key role to improve low thermal efficiency and pumping loss in gasoline engine caused by low compression ratio and throttled operation respectively.

  • PDF