• Title/Summary/Keyword: High efficiency operation

Search Result 1,911, Processing Time 0.026 seconds

Bi-directional information transmission in MAGLEV (자기부상열차에서의 양방향 정보전송)

  • Ahn, Sang-Kwon;Park, Jeong-Soo;Chang, Dae-Sik;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.434-436
    • /
    • 1996
  • This paper deals with the signal communication system for MAGLEV which is indispensible to train control with safety and high speed operation. Therefore it is necessary for signal system to ensure high speed transmission. massive transmission, low error rate, and reliability of information. And the ensured information should be transmitted between ground and on-board for safety and high speed operation. For these reasons, we have considered the guaranteed reliability by applying FSK method and HDLC protocol. Because HDLC has the advantages of high efficiency, high reliability, low bit rate, and bit transparency. HDLC is the appropriate method for data transmission in MAGLEV.

  • PDF

Frequency Adaptive High Efficiency Class-E Amplifier in 400 MHz Range (400MHz 대역의 주파수 적응형 고효율 Class-E 증폭기)

  • Ryu, Jae-Hyun;Son, Kang-Ho;Kim, Young;Yoon, Young-Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.673-675
    • /
    • 2010
  • This paper proposes the adaptive class-E power amplifier with maintaining high power added efficiency (PAE) in 400MHz range. This amplifier is used a microprocessor to adapt a resonator circuits and to maintain high efficiency in case of input frequency variation. To validate the adaptive amplifier operation, which is a 450MHz operating frequency and a 100MHz bandwidth, the class E amplifier is implemented. As a result, the adaptive amplifier is maintained above 60% efficiency and has a 74.8% maximum efficiency.

  • PDF

Stress Analysis of the Cylinder Block and the Valve Plate of the Swash Plate Type Oil Hydraulic Piston Pump (사판식 유압 픽스톤 펌프의 실린더블록과 밸브 플레이트의 응력해석)

  • Kim J. H.;Cho I. S.;Baek I. H.;Jung Jae-Youn;Oh Suk-Hyung
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.255-260
    • /
    • 2004
  • Recently, the technologies related to the swash plate type oil hydraulic piston pump are requiring extreme technologies to overcome the limit of high efficiency in cope with high speed and pressure, and are devoted to compact the unit, to gain low noise level, and to adopt electronic technologies, and the question regarding to maximize the mechanical efficiency, that is, to minimize the torque loss by minimizing the leakage loss in the relative sliding region but these are in trade-off relation that tribological responding is very difficult. Cylinder block-valve pate in high speed relative sliding motion has the characteristics that should be extremely controlled for the optimization of these leakage loss and mechanical efficiency, and pressure resistance designing of them is important for high pressure performance. But, studies on the stress analysis of these parts have not been performed briskly, so in this paper the stress distribution and the region where the highest displacement appears are described through the static stress analysis using CATIA V5. Through the future studies on these theme, it has the purpose of finding the suitable materials for the other parts as well as cylinder block and valve plate, in cope with high pressure operation through the stress analysis with the most similar conditions for the practical operation.

  • PDF

Operating Number Control of Compressors Based on Cooperative Logic for a High Efficiency Centrifugal Water Chiller (터보냉동기의 고효율 운전을 위한 협조 방식 기반의 압축기 대수제어)

  • Jeong, Seok-Kwon;Lim, Seung-Kwan;Ryu, Keon-Su
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.5
    • /
    • pp.233-240
    • /
    • 2015
  • This paper discusses compressors operating number control strategy using cooperative logic to cope with variable partial load for high efficiency of a centrifugal water chiller. The cooperative logic is composed of a speed-up and speed-down controller, enabling smooth operation of compressors and equivalent distribution of thermal load in each compressor. This centrifugal water chiller design can be operated with high efficiency without incurring excessive energy waste and large transient phenomena at partial load states. Simulations in MATLAB and experiments in a real chiller system were conducted and verified the high efficiency control of a centrifugal water chiller achieved by the suggested strategy.

Operating Characteristics Analysis Of Bi-Directional DC/DC Converter using PFM control with high efficiency at whole load range (전 부하 영역에서 고효율을 가지는 PFM 제어를 이용한 양방향 DC/DC 컨버터의 동작특성 분석)

  • Kim, Ji-Hwan;Hwang, Sun-Hee;Ryu, Dong-Gyun;Jung, Doo-Yong;Jung, Yong-Chae;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.29-30
    • /
    • 2012
  • In this paper, a performance of bi-directional DC/DC converter using PFM control at whole load range is analyzed. A bi-directional DC/DC converter using PFM control in this paper can be soft switching operation with LC series resonant circuit. It's difficult to expect a high efficiency at whole load range in general resonant converter because of limitation of soft switching area. Therefore converter used in this paper has a variable frequency PFM control to overcome a limitation of soft switching area and it makes a high efficiency at whole load range by implementing a soft switching at light load area of restricted soft switching. The high efficiency at whole load range is verified by simulation and experimental result.

  • PDF

Research on Variable Constant Current Efficiency Measuring Device for Solar Panel to Reuse (태양광 패널 재사용을 위한 가변 정전류 기반의 효율 측정장치에 관한 연구)

  • Sang-Jin Woo;Dae-Heon Kim;Jae-Jin Lee;Oh-Min Kwon
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.18 no.1
    • /
    • pp.9-17
    • /
    • 2023
  • This paper relates to the development of a device for measuring the efficiency of a solar panel based on a variable constant current, and proposed a standard for reuse of the solar panel. By applying a variable constant current circuit to a solar panel efficiency measuring device, it was easy to apply a maximum power point tracking (MPPT) algorithm. In addition, a load dispersion method was applied to measure the efficiency of a high-capacity solar panel. and it is possible to solve a problematic thermal runaway during a MOSFET parallel operation by applying the load dispersion method. As a result of the experiment, the solar panel efficiency measuring device was able to accommodate a large solar panel of 350W, which is the maximum measurement goal. In this paper, the validity was confirmed through the 310W solar panel efficiency measurement experiment collected after removal.

A Novel Non-Isolated DC-DC Converter with High Efficiency and High Step-Up Voltage Gain (고효율 및 고변압비를 가진 새로운 비절연형 컨버터)

  • Amin, Saghir;Tran, Manh Tuan;Choi, Woojin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.11-13
    • /
    • 2019
  • This paper proposes a novel high step-up non-isolated DC-DC converter, suitable for regulating dc bus in various inherent low voltage micro sources especially for photovoltaic (PV) and fuel cell sources. This novel high voltage Non-isolated Boost DC-DC converter topology is best replacement, where high voltage conversion ratio is required without the transformer and also need continuous input current. Since the proposed topology utilizes the stack-based structure, the voltage gain, and the efficiency are higher than other conventional non-isolated converters. Switches in this topology is easier to control since its control signal is grounding reference. Also, there is no need of extra gate driver and extra power supply for driver circuit, which reduces the cost and size of system. In order to show the feasibility and practicality of the proposed topology principle operation, steady state analysis and simulation result is presented and analyzed in detail. To verify the performance of proposed converter and theoretical analysis 360W laboratory prototype is implemented.

  • PDF

High-Efficiency Charge Pump for CMOS Image Sensor (CMOS 이미지 센서를 위한 고효율 Charge Pump)

  • Kim, Ju-Ha;Jun, Young-Hyun;Kong, Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.50-57
    • /
    • 2008
  • In this paper, a high-efficiency charge pump for use in CMOS image sensor(CIS) is proposed. The proposed charge pump pursues high pumping efficiency by minimizing the switching and reversion losses by taking advantage of operation characteristics of CIS. That is, the proposed charge pump minimizes the switching loss by dynamically controlling the size of clock driver, pumping capacitor, and charge transfer switch based on the operation phase of CIS pixel sensor. The charge pump also minimizes the reversion loss by guaranteeing a sufficient non-overlapping period of local clocks using a tri-state local clock driver adapting the schmitt trigger. Comparison results using a 0.13-um CMOS process technology indicate that the proposed charge pump achieves up to 49.1% reduction on power consumption under no loading current condition as compared to conventional charge pump. They also indicate that the charge pump provides 19.0% reduction on power consumption under the maximum loading current condition.

Two-Switch Auxiliary Resonant DC Link Snubber-Assisted Three-Phase Soft Switching PWM Sinewave Power Conversion System with Minimized Commutation Power Losses

  • Nagai, Shinichiro;Sato, Shinji;Ahmed, Tarek;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.249-258
    • /
    • 2003
  • This paper presents a high-efficient and cost effective three-phase AC/DC-DC/AC power conversion system with a single two-switch type active Auxiliary Resonant DC Link (ARDCL) snubber circuit, which can minimize the total power dissipation. The active ARDCL snubber circuit is proposed in this paper and its unique features are described. Its operation principle in steady-state is discussed for the three phase AC/DC-DC/AC converter, which is composed of PWM rectifier as power factor correction (PFC) converter, sinewave PWM inverter. In the presented power converter system not only three-phase AC/DC PWM rectifier but also three-phase DC/AC inverter can achieve the stable ZVS commutation for all the power semiconductor devices. It is proved that the proposed three-phase AC/DC-DC/AC converter system is more effective and acceptable than the previous from the cost viewpoint and high efficient consideration. In addition, the proposed two-switch type active auxiliary ARDCL snubber circuit can reduce the peak value of the resonant inductor injection current in order to maximize total system actual efficiency by using the improved DSP based control scheme. Moreover the proposed active auxiliary two-switch ARDCL snubber circuit has the merit so that there is no need to use any sensing devices to detect the voltage and current in the ARDCL sunbber circuit for realizing soft-switching operation. This three-phase AC/DC-DC/AC converter system developed for UPS can achieve the 1.8% higher efficiency and 20dB lower conduction noise than those of the conventional three-phase hard-switching PWM AC/DC-DC/AC converter system. It is proved that actual efficiency of the proposed three-phase AC/DC-DC/AC converter system operating under a condition of soft switching is 88.7% under 10kw output power.

A Study on Process Improvement for Reduction of Pollution Loading Rate in Small Individual Sewage Plant (소규모 개인하수처리시설의 MBR공정 적용에 관한 연구)

  • Eom, Han Ki;Choi, Yoo Hyun;Joo, Hyun Jong
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.323-329
    • /
    • 2016
  • In this study, the applicability of MBR process was evaluated to improve processing of personal sewage treatment facilities of $50m^3/day$ or less. As result of the research, stable discharge water quality could be secured as result of the MBR effector operation according to rate of inflow and inflow load and treatment efficiency of 98% or higher was shown by the membrane filtering method operation for SS, $BOD_5$. it was found that high treatment efficiency of 99% or higher. It is judged that detention time can be designed until 6.9 hr when applying MBR process on personal sewage treatment facilities with high pollution load and that cutback of pollution load can be possible through this study. It was shown that MBR process application reduces an annual cost of 4,829,600 won based on the basic unit calculation results and solves burden of amount of borne by causers according to excess of discharge water quality standards.