High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge (도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성)

  • 문재덕;이근택
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.8
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

A High Efficiency Ozone Generation Using a Electrode-edge Discharge and a Dielectric-Barrier Discharge (전극연면방전(電極沿面放電)과 유전체장벽방전(誘電體障壁放電)을 공용(共用)한 고효율(高效率) 오존발생(發生))

  • Choi, Jae-Gu;Moon, Jae-Duk
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1410-1412
    • /
    • 1995
  • A high efficiency ozone generation using both of a electrode-edge discharge and a dielectric-harrier discharge from a modified silent type ozone generator has been proposed and studied for small scale applications. It is found that the output ozone concentration of the proposed generator depended greatly upon the air gap spacing and the applied power frequency and voltage on the ozone generation. The ozone generator showed higher ozone concentration than the same size of the ceramic type surface ozone generator(Masuda type one). And, it is found that the generator had a potential to be used as an ozone generator for small scale applications.

  • PDF

Characteristics Analysis of a Direct-Drive AFPM Generator (직접 구동 AFPM 풍력발전기의 특성해석)

  • Seo, Young-Taek;Kim, Hyoung-Gil;Kong, Jeong-Sik;Kim, Chul-Ho;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.687-689
    • /
    • 2003
  • Recently, issues regarding environment and the diversification of dependence in oil are watched with keen interest. Wind power attracts most interest because of its high-energy efficiency with environment friendly functions. The paper discusses the development of a coreless axial-flux permanent magnet (AFPM) generator for a wind power system. Analyzed the Coreless AFPM generator by electromagnetic, and designed wind power generator with this. The 3 phase output of stator is rectified and fed to a common do link. The overall machine structure has high compactness and lightness, because of the lack of the iron core. The test results with a resistive load confirm the satisfactory operation of generator. Compared with conventional generator, the design has lower weight, lower Power loss and improved efficiency.

  • PDF

Development of High Efficiency Cycle by Combining Double-Effect with Single-Effect Absorption Chiller Systems (이중 효용과 일중 효용을 복합한 다단 재생 고효율 흡수식 냉동 사이클 개발)

  • Yun, Sang Kook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.360-365
    • /
    • 2017
  • Recently, development efforts of triple-effect absorption chiller have been increased in order to improve the efficiency of double-effect absorption chiller. However, triple-effect absorption chiller has some disadvantages, including high corrosion characteristic of LiBr solution at high temperature of $200^{\circ}C$. Moreover, it is necessary to develop new components for operation under high pressure of 2 bars even though COP is increased to 1.6 or 1.7. The objective of this study was to introduce a new system by combining double effect absorption chiller with single effect absorption chiller with multi-generators using bypass flow of LiBr dilute solution to $3^{rd}$ generator to overcome the disadvantages of triple-effect chiller and improve energy efficiency. Results indicate that the new absorption cycle had a much higher efficiency than double-effect chiller system, showing significant improvement when bypass solution flow rate of 25% was applied to the $3^{rd}$ generator using the main dilute solution of the absorber. The COP of the new chiller system was found to be 1.438, which was 21.7% higher than that (1.18) of the present double-effect system. The COP was decreased when solution by-pass rate to the $3^{rd}$ generator was increased. In addition, lower cooling water temperature caused higher COP. Therefore, the multi-generator system with by-pass solution might be an excellent chiller alternative to triple-effect absorption chiller with higher efficiency.

Directional Orbital Angular Momentum Generator with Enhanced Vertical Emission Efficiency

  • Tran, Thang Q.;Kim, Sangin
    • Current Optics and Photonics
    • /
    • v.3 no.4
    • /
    • pp.292-297
    • /
    • 2019
  • We propose a ring resonator-based orbital angular momentum carrying vortex beam generator design with high vertical directional emission efficiency. By adopting a vertically asymmetric grating structure in the ring resonator, optimized for enhanced vertical emission, an emission efficiency in one direction reaches as high as 78%, exceeding the 50% theoretical limit of previously designed vertically symmetric grating-assisted ring resonator-based structures.

High-efficiency Operation of Switched Reluctance Generator based on Current Waveform Control

  • Li, Zhenguo;Yu, Siyang;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.1
    • /
    • pp.120-126
    • /
    • 2013
  • The main aim of this paper is to expound high-efficiency operation of Switched Reluctance Generator (SRG) based on the current waveform. For this purpose, theoretical analysis of the copper loss and iron loss of the system is done first. Then, necessary simulation is done to find the variation trend of the copper loss and iron loss with the variation of the current waveform at the same output power. Finally, the best current waveform which can make the system operate with high efficiency is obtained by considering the influence of these two kinds of loss. In order to verity the simulation results, the experimental platform of DC motor-SRG is built and the modified angle position control (APC) method which can specify the current shape optionally is presented. By comparing the system efficiency at the three kinds of typical current waveform, the correctness and feasibility of the theory is verified. The proposed method is simple, reliable, and easy to achieve.

Reduction of series transformer voltage variation of voltage disturbance generator (전압변동 발생기의 직렬변압기에 의한 전압변동 개선)

  • Nho, E.C.;Lee, Y.H.;Min, B.H.;Kim, I.D.;Chun, T.W.;Kim, H.G.;Choi, N.S.
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.218-220
    • /
    • 2007
  • A new 3-phase voltage disturbance generator is proposed. The voltage drop of the conventional generator in normal mode can be reduced significantly. The output voltage of the proposed generator is constant in normal mode and the efficiency of the series transformer is improved. The proposed generator has good feature of simple structure, cost effective implementation, high reliability, high efficiency, and easy control. The usefulness of the scheme is verified through simulation and experiments.

  • PDF

High Performance MPPT Based on Variable Speed Generator Driven by Wind Power Generation in Battery Applications

  • Padmanabhan, Sutha;Kaliyappan, Kannan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.205-213
    • /
    • 2014
  • A wind generator (WG) maximum power point tracking (MPPT) system is presented here. It comprises of a variable-speed wind generator, a high-efficiency boost-type dc/dc converter and a control unit. The advantages of the aimed system are that it does not call for the knowledge of the wind speed or the optimal power characteristics and that it operates at a variable speed, thus providing high efficiency. The WG operates at variable speed and thus suffers lower stress on the shafts and gears compared to constant-speed systems. It results in a better exploitation of the available wind energy, especially in the low wind-speed range of 2.5-4.5 m/s. It does not depend on the WG wind and rotor-speed ratings or the dc/dc converter power rating. Higher reliability, lower complexity and cost, and less mechanical stress of the WG. It can be applied to battery-charging applications.

A Technical Trends of Direct-Driven Permanent Magnet Generator for Wind Turbine (직접구동 영구자석 풍력발전기 기술동향)

  • Lee, Jung-Il;Kwon, Jung-Lock;Kim, Ki-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.97-100
    • /
    • 2003
  • Recently, the generators for wind turbine have been manufactured with high output power such like MW class machine in order to reduce the generation cost and to increase the energy efficiency. At the same time, direct-driven generators for wind turbine have been developed and researched, which have easy maintenance and high efficiency by simplification the system through the removal of the gear box. In this paper, at first, the advantage and disadvantage between the direct-driven generator system and conventional indirect-driven system are compared. And secondly, the permanent magnet generator (PMG) for wind turbine has been rapidly improved to cope with the recent trend which requires the high power output Per one machine and the convenience for maintenance, and the PMG is adequate for direct driven system and suitable for high-efficiency and light weight. So, the characteristics and technical trend of the PMG for wind turbine is examined. At last, a suitable technical trend for development of the permanent magnet generator for wind turbine is proposed.

  • PDF

Water Absorption Sensor of Generator Stator Bar Insulation using Cross Capacitance (크로스 커패시턴스를 이용한 발전기 고정자 권선 절연물 흡습 측정 센서)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun;Lee, Rae-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1972-1977
    • /
    • 2011
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. To cool down the heat emitted from generator winding during its operation, a majority of generators use de-mineralized water characterized by high cooling efficiency. Contrary to such the excellent cooling efficiency, however, the damaged bar insulations attributed to the absorption of cooling water in the generator stator winding lead to highly time- and cost consuming efforts as well as to service deterioration due to unexpected forced outage of generator. It is described that the new design of water absorption sensor using cross capacitance for generator in power plant in order to increase the reliability of water absorption diagnostics for generator stator bar insulation.