• 제목/요약/키워드: High efficiency apparatus

검색결과 119건 처리시간 0.023초

슈퍼윈도우 열성능에 따른 지역별 건물에너지 효율등급에 관한 연구 (A Study of the evaluation of Building Energy Rating depending on region according to the Insulation Performance of the Super window)

  • 장철용;안병립;김치훈
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.211-215
    • /
    • 2009
  • As entering in the time of high oil price, seriousness of an energy is on the rise and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficiency rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

  • PDF

감 수확기구 개발(2) - 고지 전정기 개량 - (Development of persimmon harvest apparatus - Improvement of a high-ground trimmer -)

  • 우덕감;김태한
    • Current Research on Agriculture and Life Sciences
    • /
    • 제27권
    • /
    • pp.7-11
    • /
    • 2009
  • 우리나라에서 감은 재배면적으로 볼 때 사과 다음으로 넓은 면적을 차지하고 있다. 그러나 감 재배 포장의 70%가 경사지에 있어서 수확작업의 효율성이 떨어진다. 기존의 감 수확에 이용되는 고지전정기는 구조상의 문제로 인해 사용 시 많은 힘이 소요된다. 본 연구는 이와 같은 문제점의 해결을 위해 기존의 고지 전정기를 개량하여 감탈과시 소요되는 고지전정기의 레버 장력을 기존의 고지전정기와 비교하였다. 그 결과를 요약하면 다음과 같다. 1. 기존의 스프링레버식 고지전정기의 탈과 시 소요되는 레버 장력은 최대 34.4 N, 최소17.7 N, 평균 25.5 N으로 나타났다. 2. 개발한 유압레버식 고지전정기의 탈과 시 소요되는 레버장력은 최대 4.9 N, 최소0.2 N, 평균2.9 N으로 나타났다. 3. 개발한 유압레버식 고지전정기의 평균 장력은 유압레버식이 2.9 N이고 스프링레버식이 25.5 N으로서 스프링레버식이 유압레버식보다 8.7배 큰 것으로 나타났다. 4. 수합장치의 수합율은 개량한 장치가 기존의 것보다 7% 높게 나타났다.

  • PDF

지능형 조명 제어 시스템용 LED 단말기 개발 (A Study for Designing of Intelligent Lighting Control LED Apparatus)

  • 유수엽;이기헌
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2008
  • This paper is a report of designing for LED lights driver unit. The main purpose of driver designing is high electrical efficient performance and intelligent control LED driver. This LED driver can be used for intelligent light control. This product expects to improve the light control by dimming instead of interlace on/off light control that increases the social cost such as car accidents and etc.

  • PDF

연소장치를 이용한 소형 전기집진장치의 집진 효율에 관한 연구 (A Study on Collection Efficiency of Pilot Electrostatic Precipitator)

  • 한재균;최금찬
    • 한국대기환경학회지
    • /
    • 제9권2호
    • /
    • pp.125-131
    • /
    • 1993
  • Electrostatic Precipitator has been widely used to get high efficiency which is required for collection of fine particles. In order to provide collection efficiency and size distribution data for a pilot electrostatic precipitator, a pilot study has been conducted on fly ash from pulverized coal burning apparatus. The aims of this study are to investigate characteristics of electric charge, to measure collection efficiency varied with the applied voltage, to get an optimum current and current density. Optimum current density was obtained to 0.7mA/$cm^2$ at the average electric field strength 2.33kV/cm in this experiment. Maximum particle collection efficiency was indicated 99.21% at the applied voltage 7kV. Finally, particle size distribution is also compared with photographic results. Both coarse and fine particles at the range of 0.5$\sim$2$\mu$m and 3$\sim$10 SEM $\mu$m were clearly removed by increasing applied voltage.

  • PDF

세라믹스의 축열연소시스템 응용 (Ceramic Application for Regenerative Burner System)

  • 한동빈;박병학;김영우;배원수
    • 한국세라믹학회지
    • /
    • 제36권5호
    • /
    • pp.497-503
    • /
    • 1999
  • Recently regenerative burner system was developed and begins to be gradually used for better energy savings. Compared to conventional burner system the regenrative one has the several merits such as higher fuel efficiency light weigh of apparatus low harmful toxic gas and homogeneous heating zone etc. The regenerative material a very important component of the new regenerative burner system should possess the properties of low specific density higher surface area and high specific heat capacity. Ceramics is the best regenerative material because of stable mechanical properties even at high temperature and better thermal properties and excellent chemical stability. In this study alumina ball alumina tube 3-D ceramic foam and hoeycomb as regenerative materials were tested and evaluated. The computer silumation was conducted and compared to the result of field test. This paper is aimed to introduce a new application of ceramics at high temperature.

  • PDF

고속 3차원 형상 측정 장치의 효율성 향상에 관한 연구 (A Study on the Efficiency Improvement of a 3D Shape Measuring Apparatus With High Speed)

  • 박승규;이일근;이영훈
    • 한국컴퓨터정보학회논문지
    • /
    • 제6권4호
    • /
    • pp.104-109
    • /
    • 2001
  • 본 논문에서는 정현파 줄무의 패턴을 이용하여 고속이면서도 정밀하게 측정체 표면의 3차원 형상을 측정하는 시스템을 구성하였다. 또한 획득영상의 위상정보 부족 영역에대하여 효율적인 위상복원 방법을 사용하여 측정효율을 높이는 방법을 제안하였고 이를 실험적으로 확인하였다. 카메라의 측정각도와 측정체의 형상에 따라 카메라에 획득되는 영상에는 필연적으로 위상 정보가 부족한 영역이 존재하며 본 논문에서는 이 영역을 추출하고 가변 크기의 위상복원 창과 가변 비율을 갖는 정규화 방법을 사용하여 위상을 효과적으로 복원함으로써 시스템의 측정 효율을 높였다.

  • PDF

초음파 직물수세기의 구성 및 구동 특성 (Assemblage and Driving Characteristics of a Ultrasonic Fabric Washing Machine)

  • 이춘길;이광수
    • 한국염색가공학회지
    • /
    • 제12권3호
    • /
    • pp.207-217
    • /
    • 2000
  • A new, high-efficiency ultrasonic fabric washing machine was developed to be an energy-efficient washing machine and to enhance fabric washing quality in washing processes of the dyeing and finishing process in the textile industry. This system is composed of ultrasonic wave generator, air blowing nozzle, torque motor for fabric tension control, and enclosed washing bath, multi-tube type exchanger, noiseless heater, air cylinder, expander roller, mangle upper and lower rollers, bend bar, dancer, shower spray nozzle, and solenoid valve, and so on. These elements are synergised for fabric washing. One of the very important principles is the low tension fabric running system. For an efficient washing effect, a counter flow system is also adopted. The new system also adopts the dancer and torque motor to control fabric tension and prevent fabric creasing. Shower spray nozzle, counter flow and overflow apparatus, and air-blowing apparatus are adopted to enhance the fabric washing effect. In this study, peach yoryu, exter, and moss crepe fabrics were washed by the general and ultrasonic washing systems under different conditions respectively. The washing efficiency was affected by the fabric running speed and characteristics of fabrics. Size content after washing increased with increasing the fabric running speed. The values in the general washing system were higher than those of the ultrasonic washing system. The changes of conductivity in the ultrasonic and the cooling bath were affected by the running time under the ultrasonic generating. The values of conductivity decreased as the experimental time passed.

  • PDF

생물활성탄을 이용한 절삭유로 오염된 지하수의 처리특성과 미생물군집구조 해석 (Treatment Performance and Microbial Community Structure in BAC-process Treating Contaminated Groundwater by Water-soluble Cutting Oil)

  • 임병란;배시애;임호주;조창호
    • 한국환경보건학회지
    • /
    • 제32권1호
    • /
    • pp.71-76
    • /
    • 2006
  • Treatment performance and microbial community structure were investigated in water-soluble cutting oil treatment process using biological activated carbon. DOC removal in BACI column at $15^{\circ}C$ was higher than at $25^{\circ}C$, but those of BAC3 column after 60days was high at$25^{\circ}C$. Also, quinone content of first-step reactors at $25^{\circ}C$ and $15^{\circ}C$ was much the same, but those of the third-step reactor at $25^{\circ}C$ was higher than at $15^{\circ}C$. The dominant type of two apparatus was ubquinone (UQ)-l 0 followed by UQ-8. Menaquinones were detected from $25^{\circ}C$ apparatus and effluent. This suggested that DOC removal at $25^{\circ}C$ was advanced degradation by attached microorganisms on the activated carbon surface. The DOC removal in long-term activated carbon apparatus increased with going in BAC3 column. This indicated the influent of POC was a result of DOC removal efficiency decrease. Integrated DOC removal from start point in experiment to break point and quinone content were showed a tendency of increasing with going last-step activated carbon apparatus. Therefore, the biological activated carbon apparatus used by this study was effective treatment process in contaminated groundwater by water-soluble cutting oil.

세라믹 섬유필터를 이용한 디젤 입자상물질 배출저감에 관한 기초연구 (A Study on the Exhaust Reduction of Diesel Particulates Using Ceramic Fiber Filters)

  • 주용남;홍민선;문수호;이동섭;임우택
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.297-306
    • /
    • 2003
  • Works were focused on back pressure characteristics of ceramic fiber filter on DPF (Diesel Particulate Filter) system and experiments were performed to select appropriate filter which can filter particulates. Filters were installed on metal -support tube which has openings for exhaust gas flow. Ceramic fiber filters with high specific surface area and adequate high temperature strength are commercially available for filtration of diesel particulates and in -situ hot regeneration. Thus, ceramic blanket and ceramic board which are used as insulating media were applied to filter and filtration apparatus was installed on exhaust gas line connected to 2.0 L diesel engine. Alternating filter structure to adapt DPF system, collection efficiency test of diesel particulates was measured. In case of ceramic blanket, pressure drop was low, caused by the destruction of soft structures. Also, particulate collection efficiency was decreased depending on loading time. In case of ceramic board, structure design was altered to reduce back pressure on DPF system. Structure design was altered to induce Z-flow by making 10 mm and 5 mm holes on the surface of media. Alteration of 5 mm hole showed that media have low back pressure but particulate collection efficiency was 77%, while 10 mm hole showed that of 90%.

PC 펠렛의 마이크로웨이브 건조를 위한 에너지 효율 분석 (Analysis of Energy Consumption for Microwave Drying in PC Pellet)

  • 이현민;김재경;전의식
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.44-48
    • /
    • 2021
  • Semiconductor inspection equipment makes components using materials with insulating properties for functional inspection including current and voltage of semiconductor parts. A representative insulating material is plastic, and plastic is made of a component through an injection process using plastic pellet. When plastic pellets contain excessive moisture, problems such as performance degradation and product surface defects occur. To prevent this, pre-drying is essential, and the heat convective type is the most applied. However, the heat convective type has a problem of low consumption efficiency and a long drying time. Recently, many studies have been conducted on a drying method using microwaves due to high energy efficiency. In this paper, drying was performed using a microwave for drying PC pellets. Energy consumption and drying efficiency analyzed by set up an experimental apparatus of heat convective, microwave, and hybrid(heat convective + microwave) types. It was confirmed that energy consumption and drying efficiency were high when drying using microwaves, and it was confirmed that the hybrid method improved drying performance compared to the heat convective method. It is expected that the research results of this paper can be used as basic data for drying plastic pellets using microwave.