• 제목/요약/키워드: High dose

검색결과 4,239건 처리시간 0.034초

PTU 투여 갑상선기능저하증 유발 랫드모델에서 고용량 MOK 약침의 효능 및 안전성 평가 연구 (Study on Efficacy and Safety of High Dose MOK Pharmacopuncture in Hypothyroidism-induced Rats with Propylthiouracil)

  • 황지혜;임우현;정철;정효원
    • 동의생리병리학회지
    • /
    • 제33권2호
    • /
    • pp.123-130
    • /
    • 2019
  • In this study, we investigated the effects of MOK pharmacopuncture at high-doses which are increased 10 to 100-fold in clinics, on propylthiouracil (PTU)-induced hypothyroidism in rats and the safety. We measured the changes of body weight, food and water intake, body temperature, the serum levels of thyroid hormones (TSH, T3, and T4), AST and ALT, glucose, lipid metabolites (total cholesterol, HDL-cholesterol, LDL-cholesterol, and triglyceride) and observed histopathological changes of thyroid tissues by H&E staining. We also analyzed the peaks of constituents of MOK using HPLC. In the results, the treatment of MOK pharmacopuncture at high-dose (30 mg/kg) in hypothyroidism-induced rats for 2 weeks was shown the improvement effects on the decrease of body weight, food intake, and body temperature, The MOK pharmacopunture at high dose regulated the imbalance of thyroid hormones, glucose, and lipid metabolites and also inhibited the structural damages of thyroid tissues. In liver damage, the MOK pharmacopuncture at high dose reduced the increase of AST and ALT levels in hypothyroid rats. We identified the MOK constituents in HPLC analysis. In conclusion, the treatment of MOK pharmacopuncture at high dose has a therapeutic effect on hypothyroidism without liver toxicity, suggesting that the MOK pharmacopuncture be usefully applicable to treat with hypothyroidism in clinics.

고선량율 근접치료기의 선원교정과 치료실주변 방사선량 측정 (Calibration and Radiation Survey of High Dose Rate Remote Afterloading System)

  • 이정옥;강정구;문성록
    • Radiation Oncology Journal
    • /
    • 제13권1호
    • /
    • pp.101-104
    • /
    • 1995
  • High Dose Rate Remote Afterloading system was installed at Wonkwang University Hospital in January 1994. In this report, the calibration of a Gammamed 12-i High Dose Rate Remote Afterloading system and the radiation survey around the facility after design and construct a shieding room are discussed. The radiation survey of the facility indicates that the use of ordinary concrete shielding of existing room will provide adequate shielding. Also, the methodologies for performing source calibration are presented.

  • PDF

Clinical management of suspected intracranial meningioma in three dogs with pulsed high-dose hydroxyurea

  • Cho, Jae-Geum;Song, Kun-Ho;Seo, Kyoung-Won
    • 대한수의학회지
    • /
    • 제58권2호
    • /
    • pp.103-106
    • /
    • 2018
  • Three aged dogs, all over 15 years old, with multiple seizure events and various neurologic signs such as head turn and ataxia were brought to the referring hospital. Two cases were tentatively diagnosed with intracranial meningioma based on magnetic resonance imaging, and one case was histopathologically confirmed as meningioma at necropsy. All dogs improved after initiation of pulsed high-dose hydroxyurea (HU) treatment. Clinical sign relapses were managed by repeating high-dose HU without obvious side effects. Pulsed high-dose HU can be applied when clinical signs are refractory to the traditionally recommended dosage for intracranial meningioma in dogs.

비골수제거성 조혈모세포이식 (Nonmyeloablative Stem Cell Transplantation)

  • 현명수
    • Journal of Yeungnam Medical Science
    • /
    • 제19권1호
    • /
    • pp.11-27
    • /
    • 2002
  • Allogenic hematopoietic stem cell transplantation is one of the effective therapy for several hematologic malignancies. Transplantation preparative regimen is designed to eradicate the patient's underlying disease and immunosuppress the patient adequately to prevent rejection of donor's hematopoietic stem cells. So, conventional myeloablative preparative regimens with high-dose chemotherapy or radiotherapy are related to high rate of morbidity and mortality. However, It has become clear that the high-dose therapy dose not eradicate the malignancy in some patients, and that the therapeutic benefit of allogenic transplantation is largely related to graft-versus-leukemia/graft-versus-tumor (GVL/GVT) effect. An new approach is to utilize less toxic, nonmyeloablative preparative regimens to achieve engraftment and allow GVL/GVT effects to develop. This strategy reduces the risk of treatment-related mortality and allows transplantation for elderly and those with comorbidities that preclude high-dose chemoradiotherapy.

  • PDF

저 에너지 이온 주입의 개선을 위한 변형된 감속모드 이온 주입의 안정화 특성 (Stabilization of Modified Deceleration Mode for Improvement of Low-energy Ion Implantation Process)

  • 서용진;박창준;김상용
    • 한국전기전자재료학회논문지
    • /
    • 제16권3호
    • /
    • pp.175-180
    • /
    • 2003
  • As the integrated circuit device shrinks to the deep submicron regime, the ion implantation process with high ion dose has been attracted beyond the conventional ion implantation technology. In particular, for the case of boron ion implantation with low energy and high dose, the stabilization and throughput of semiconductor chip manufacturing are decreasing because of trouble due to the machine conditions and beam turning of ion implanter system. In this paper, we focused to the improved characteristics of processing conditions of ion implantation equipment through the modified deceleration mode. Thus, our modified recipe with low energy and high ion dose can be directly apply in the semiconductor manufacturing process without any degradation of stability and throughput.

Intra-Articular Injection of High-Dose ELHLD Peptide for Managing Canine Stifle Osteoarthritis: Kinetic Gait Analysis

  • Jeong, Na-rae;Kang, Byung-Jae
    • 한국임상수의학회지
    • /
    • 제38권3호
    • /
    • pp.105-114
    • /
    • 2021
  • Intra-articular injection of ELHLD peptide is considered to have a therapeutic effect in osteoarthritis (OA) through the inhibition of transforming growth factor-β1. This study aimed to assess the efficacy of intra-articular injections of high-dose ELHLD peptide (100 ㎍/kg) in canine stifle OA. Six client-owned dogs diagnosed with stifle OA were included. Selected dogs were treated with an intra-articular injection of high-dose ELHLD peptide (100 ㎍/kg). Outcome measures, including orthopedic examination, gait analysis, and Canine Brief Pain Inventory (CBPI) score, were evaluated four times after injection. Orthopedic examination, gait analysis, and owner's assessment (CBPI) improved significantly from 4 weeks after injection. In conclusion, we obtained sufficient evidence from this small sample that high-dose ELHLD peptide improves clinical signs of canine OA not only through subjective assessment but also through objective evaluation.

인체등가형 흉부팬텀과 유리선량계를 이용한 고해상력 및 저선량 CT의 선량측정 (Measurement of Radiation Dose of HR CT and Low Dose CT by using Anthropomorphic Chest Phantom and Glass Dosimetry)

  • 권대철
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.933-939
    • /
    • 2019
  • MDCT에서 인체등가형 흉부팬텀과 유리선량계를 이용하여 고해상력 및 저선량 CT로 검사하여 영상의 평가 및 흡수선량 및 유효선량을 측정하여 임상 기초자료를 제공하는데 목표를 두고자한다. 인체등가형 흉부팬텀내부에 유리선량계를 삽입하여 조직선량을 측정하였다. 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany)과 CARE Dose 4D를 이용하였고, 고해상력 CT에서의 파라메터는 관전압 120 kVp, Eff. mAs 104, scan time 7.93 sec, slice 1.0 mm (Acq. 64×0.6 mm), convolution kernel (B60f sharp)의 스캔 파라메터가 사용되었고, 저선량 CT는 120 kVp, Eff. mAs 15, scan time 7.41 sec, slice 3.0 mm (Acq. 64×0.6 mm), convolution kernel B50f medium sharp의 스캔하였다. 인체등가형 흉부팬텀을 이용하여 스캔에 따른 CTDIvol은 고해상력 CT에서 8.01 mGy, 저선량 CT는 1.18 mGy로 측정되었다. 저선량 CT 검사는 고해상력 CT 검사에 비해 흡수선량이 85.49%가 감소하였고 영상의 차이는 없어 임상에서 유용하게 적용할 수 있다.

적외선 열영상을 이용한 가시광 통신모듈의 고선량 감마선조사에 따른 열화 분석 (Analysis of Visible Light Communication Module Degraded by High Dose-Rate Gamma Irradiation using Thermal Infrared Image)

  • 조재완;홍석붕;구인수
    • 제어로봇시스템학회논문지
    • /
    • 제17권12호
    • /
    • pp.1203-1209
    • /
    • 2011
  • In this paper, the degradation evaluation method of VLC (Visible Light Communication) wireless module after high dose rate gamma-ray irradiation using the thermal infrared camera is proposed. First, the heating characteristics of the active devices embedded in the VLC wireless module during the condition of normal operation is monitored by thermal infrared camera. By the image processing technique, the trends of the intensity of the heat emitted by the active devices are calculated and stored. The feature of the blob area including the area of the active devices in the thermal infrared image is extracted and stored. The feature used in this paper is the mean value of the gray levels in the blob area. The same VLC module has been gamma irradiated at the dose rate of about 4.0 kGy/h during 72 hours up to a total dose of 288 kGy. And then, the heating characteristics of the active devices embedded in the VLC wireless module after high dose gamma ray irradiation is observed by thermal infrared camera. The high dose gamma-ray induced degradation of the active devices embedded in the VLC module was evaluated by comparing the mean value of the blob area to the one of the same blob area of the VLC module before the gamma ray irradiation.

국내 가와사키병 환아의 약물사용 (Drug Utilization in Korean Children with Kawasaki Disease)

  • 차승희;제남경
    • 한국임상약학회지
    • /
    • 제27권3호
    • /
    • pp.127-135
    • /
    • 2017
  • Background: Kawasaki disease (KD) is an acute febrile, systemic vasculitis as a leading cause of acquired heart disease in children. Intravenous immunoglobulin G (IVIG) and aspirin are the standard initial therapy in the treatment of acute KD. The purpose of this study was to investigate drug utilization in children with KD, and to compare "IVIG + high-dose aspirin" and "IVIG + moderate-dose aspirin" in preventing cardiac complications. Methods: We analyzed pediatric patient sample data compiled by the Health Insurance Review & Assessment Service from 2010 to 2015. We identified patients with KD using the KCD-6 code of M30.3. We excluded patients in chronic phase or ${\geq}1$0 years. We also excluded patients who were diagnosed KD in November or December. Drug utilization pattern were assessed in acute KD patients and 30-day and 60-day cardiac complications were investigated between "IVIG + high-dose aspirin" group and "IVIG + moderate-dose aspirin" group. Results: In acute phase, IVIG was administered to 95.8% patients, and 57.1% patients were prescribed moderate-dose aspirin and 25% patients were with high-dose aspirin. Steroid use was rapidly increased from 4.0% in 2010 to 11.3% in 2015. Both 30-day and 60-day cardiac complications occurred less in "IVIG + high-dose aspirin" group compared to "IVIG + moderate-dose aspirin" group, but not statistically significant (0.9% vs 1.8%, p=0.252 for 30-day complication rate; 1.5% vs 2.7%. p=0.073 for 60-day complication rate). Conclusion: We were not able to demonstrate which aspirin therapy is superior for preventing cardiac complications in acute KD patients and further research is warranted.

방사선 치료용 고에너지 전자선의 조직 내 선량분포 특성에 관한 연구 (Study on Characteristics of Dose Distribution in Tissue of High Energy Electron Beam for Radiation Therapy)

  • 나수경
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.175-186
    • /
    • 2002
  • The purpose of this study is directly measure and evaluate about absorbed dose change according to nominal energy and electron cone or medical accelerator on isodose curve, percentage depth dose, contaminated X-ray, inhomogeneous tissue, oblique surface and irradiation on intracavitary that electron beam with high energy distributed in tissue, and it settled standard data of hish energy electron beam treatment, and offer to exactly data for new dote distribution modeling study based on experimental resuls and theory. Electron beam with hish energy of $6{\sim}20$ MeV is used that generated from medical linear accelerator (Clinac 2100C/D, Varian) for the experiment, andwater phantom and Farmer chamber md Markus chamber und for absorbe d dose measurement of electron beam, and standard absorbed dose is calculated by standard measurements of International Atomic Energy Agency(IAEA) TRS 277. Dose analyzer (700i dose distribution analyzer, Wellhofer), film (X-OmatV, Kodak), external cone, intracavitary cone, cork, animal compact bone and air were used for don distribution measurement. As the results of absorbed dose ratio increased while irradiation field was increased, it appeared maximum at some irradiation field size and decreased though irradiation field size was more increased, and it decreased greatly while energy of electron beam was increased, and scattered dose on wall of electron cone was the cause. In percentage depth dose curve of electron beam, Effective depth dose(R80) for nominal energy of 6, 9, 12, 16 and 20 MeV are 1.85, 2.93, 4.07, 5.37 and 6.53 cm respectively, which seems to be one third of electron beam energy (MeV). Contaminated X-ray was generated from interaction between electron beam with high energy and material, and it was about $0.3{\sim}2.3\%$ of maximum dose and increased with increasing energy. Change of depth dose ratio of electron beam was compared with theory by Monte Carlo simulation, and calculation and measured value by Pencil beam model reciprocally, and percentage depth dose and measured value by Pencil beam were agreed almost, however, there were a little lack on build up area and error increased in pendulum and multi treatment since there was no contaminated X-ray part. Percentage depth dose calculated by Monte Carlo simulation appeared to be less from all part except maximum dose area from the curve. The change of percentage depth dose by inhomogeneous tissue, maximum range after penetration the 1 cm bone was moved 1 cm toward to surface then polystyrene phantom. In case of 1 cm and 2 cm cork, it was moved 0.5 cm and 1 cm toward to depth, respectively. In case of air, practical range was extended toward depth without energy loss. Irradiation on intracavitary is using straight and beveled type cones of 2.5, 3.0, 3.5 $cm{\phi}$, and maximum and effective $80\%$ dose depth increases while electron beam energy and size of electron cone increase. In case of contaminated X-ray, as the energy increase, straight type cones were more highly appeared then beveled type. The output factor of intracavitary small field electron cone was $15{\sim}86\%$ of standard external electron cone($15{\times}15cm^2$) and straight type was slightly higher then beveled type.

  • PDF