• Title/Summary/Keyword: High dose

Search Result 4,271, Processing Time 0.028 seconds

A study on the accuracy of source position in HDR brachytherapy according to the curvature of Universal applicator transfer tube and applicator type (원격 후 장전치료기를 사용한 고선량률 근접치료시 기구의 형태와 선원 전달 도관의 곡률 변화에 따른 선원위치 정확성에 관한 고찰)

  • Shin, Hyeon Kyung;Lee, Sang Kyoo;Kim, Joo Ho;Cho, Jeong Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • Purpose : The goal of this study was to verify and analyze the source position according to the curvature of the universal applicator and 4 different angle applicators when using RALS(Remote After Loading System). Materials and Methods : An interval of 1 cm and 15 second dwell times in each source position were applied for plan. To verify the accuracy of source position, we narrowed the distance between MultiSource container and GAFCHROMIC$^{(R)}$ EBT3 film by 5 cm, 10 cm, 20 cm so that the universal applicator transfer tube had some curvature. Also 4 applicators(Intrauterine tube: $0^{\circ}$, $15^{\circ}$, $30^{\circ}$, Ovoid tube: $65^{\circ}$) were used in the same condition. The differences between desired and actual source position were measured by using Image J. Results : In case of using 4 different angles of applicator with the straight universal applicator transfer tube, the average error was the lowest for $0^{\circ}$ applicator, greatest for $65^{\circ}$ applicator. However, All average errors were within ${\pm}2mm$ recommended in TG-56. When MultiSource container was moved 5 cm, 10 cm, 20 cm towards the EBT3 film, the average errors were beyond ${\pm}2mm$. The first dwell position was relatively located in accuracy, while the second and third dwells were displaced by an increasing magnitude with increasing curvature of the transfer tube. Furthermore, with increasing the angle of applicators, the error of all other dwell positioning was increased. Conclusion : The results of this study showed that both the curvature of universal applicator transfer tube and the angle of applicators affect the source dwell position. It is recommended that using straight universal applicator transfer tubes is followed in all cases, in order to avoid deviations in the delivered source dwell position. Also, It is advisable to verify the actual dwell position, using video camera quality control tool prior to all treatments.

  • PDF

A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources (고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰)

  • Baek, Tae-Seong;Lee, Seung-Wook;Na, Soo-Kyong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose: To compare of the accuracy among various measurement procedures of HDR Brachytherapy, and to evaluate the clinical suitability and usefulness of alternative PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom without any additional cost due to the purchase of measuring apparatus. Materials and Methods: We made a comparative study on three types of measuring systems: well type chamber, source calibration jig, and PMMA plate phantom. Farmer type chamber was used for source calibration jig method and PMMA plate phantom method. Measurement was done 5 times each in comparison with the measurement values from manufacturer. Measurement results from experiment were compared with that from the manufacturer which is offered with the source whenever a source is substituted by a new one and evaluate the accuracy of source activity. Results: As a consequence of Ir-192 source measurement using well type chamber, source calibration jig and PMMA plate phantom, RMS (Root Mean Square) values for the relative error are 0.6%, 1.57%, 2.1%, respectively, compared with the data from manufacturer. And the mean errors with standard deviation are given $-0.2{\pm}0.5%$, $0.97{\pm}1.23%$, $-0.89{\pm}1.87%$ respectively. Conclusion: From the results shown by the three types of measurement system (well type chamber, source calibration jig, and PMMA plate phantom), the measurement with well type chamber produced the best accuracy. It turns out that we can also use the alternative system of PMMA plate phantom clinically without purchasing any additional particular apparatus since the system does not exceed the recommendation of AAPM (American Association of Physicists in Medicine), which requires the error range of within ${\pm}5%$.

  • PDF

Dosimetric Comparison of Left-sided Whole Breast Irradiation using a Virtual Bolus with VMAT and static IMRT (좌측 유방의 세기변조 방사선치료 시 Virtual Bolus 적용에 따른 선량 변화 비교 평가)

  • Lim, Kyeong Jin;Kim, Tae Woan;Jang, Yo Jong;Yang, Jin Ho;Lee, Seong Hyeon;Yeom, Du Seok;Kim, Seon Yeong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.2
    • /
    • pp.51-63
    • /
    • 2019
  • Purpose: Radiation therapy for breast cancer should consider the change in breast shape due to breathing and swelling. In this study, we evaluate the benefit of using virtual bolus for IMRT of left breast cancer. Materials and methods: 10 patients with early breast cancer who received radiation therapy after breastconserving surgery compared the VMAT and IMRT plans using the virtual bolus method and without using it. The first analysis compared the V95%, HI, CI of treatment volume, Dmean, V5, V20, V30 of ipsilateral lung, and Dmean of heart in VMAT plan made using the virtual bolus method(VMAT_VB) to the plan without using it(VMAT_NoVB) in case there is no change in the breast. In IMRT, the same method was used. The second analysis compared TCP and NTCP based on each treatment plan in case there is 1cm expansion of treatment volume. Result: If there is no change in breast, V95% in VB Plan(VMAT_VB, IMRT_VB) and NoVB Plan(VMAT_NoVB, IMRT_NoVB) is all over 99% on each treatment plan. V95% in VMAT_NoVB and VMAT_VB is 99.80±0.17% and 99.75±0.12%, V95% in IMRT_NoVB and IMRT_VB is 99.67±0.26% and 99.51±0.15%. Difference of HI, CI is within 3%. OAR dose in VB plan is a little high than NoVB plan, and did not exceed guidelines. If there is 1cm change in breast, VMAT_NoVB and IMRT_NoVB are less effective for treatment. But VMAT_VB and IMRT_VB continue similar treatment effect compared in case no variation of breast. Conclusion: This study confirms the benefit of using a virtual bolus during VMAT and IMRT to compensate potential breast shape modification.

Postoperative Radiotherapy for Parotid Gland Malignancy (귀밑샘 악성 종양의 수술 후 방사선 치료)

  • Eom Keun-Yong;Wu Hong-Gyun;Kim Jae-Sung;Park Charn Il;Kim In-Ah;Kim Kwang Hyun;Lee Chae Seo
    • Radiation Oncology Journal
    • /
    • v.23 no.3
    • /
    • pp.131-136
    • /
    • 2005
  • Purpose: The aim of this study was to evaluate the clinical results of postoperative radiotherapy for parotid gland malignancy, and determine prognostic factors for locoregional control and survival. Materials and Methods: Between 1980 and 2002, 130 patients with parotid malignancy were registered In the database of the Department of Radiation Oncology, Seoul National University Hospital. The subjects of this analysis were the 72 of these 130 patients who underwent postoperative Irradiation, There were 42 males and 30 females, with a median age of 46.5 years. The most common histological type was a mucoepidermoid carcinoma. There were 6, 23, 23 and 20 patients in Stages I, II, III and IV, respectively. The median dose to the tumor bed was 60 Gy, with a median fraction size of 1.8 Gy. Results: The overall 5 and 10 year survival rates were 85 and $76\%$, respectively, The five-year locoregional control rate was $85\%$, which reached a plateau phase after 6 years. Sex and histological type were found to be statistically significant for overall survival from a multivariate analysis. No other factors, Including age, facial nerve palsy and stage, were related to overall survival. For locoregional control, nodal involvement and positive resection margin were associated with poor local control. Histological type, tumor size, perineural invasion and type of surgery were not significant for locoregional control. Conclusion: A high survival rate of parotid gland malignancies, with surgery and postoperative radiotherapy, was confirmed. Sex and histological type were significant prognostic factors for overall survival. Nodal Involvement and a positive resection margin were associated with poor locoregional control.

The Results of Radiation Therapv for Adenocarcinoma of the Uterine Cervix (자궁경부 선암 환자에 대한 생존율과 실패양상 분석)

  • Lee, Ho-Jun;Kim, Jin-Hee;Kim, Ok-Bae
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.16-22
    • /
    • 1999
  • Purpose : This study was done to analyze prognostic factors and patterns of failure of patients with histologically confirmed adenocarcinoma of the uterine cervix. Materials and Methods : From June 1988 to December 1990, a retrospective analysis was undertaken for 45 patients who were treated with curative radiation therapy for adenocarcinoma of the uterine cervix at the department of Therapeutic Radiology of Keimyung University Hospital. According to FIGO staging classification, f2 patients were stage Ib, 9 patients were lla, 19 patients were IIB, and 5 patients were lIIb. Median age of the patients was 54 years. The radiation therapy consisted of a combination of external and intracavitary irradiation. Only the pelvis was treated for external irradiation, but 6 patients were treated with extended field irradiation including paraaortic nodes. Intracavitary irradiation was performed with high dose rate sources (Co-60). Neoadiuvant chemotherapy was undertaken for 10 patients. Median and maximum follow-up duration was 64 and 116 months, respectively. Results : The overall 5-year survival rate was 55.2$\%$, and the 5-year survival rates for stage Ib, IIa, IIb, and IIIb were 100$\%$, 50.8$\%$, 46.8$\%$, and 40$\%$ (3-year survival rate), respectively. Of the many clinicopathologic variables evaluated for prognosis, only the stage and the tumor size were significant prognostic factors. Statistically, pelvic failure rates for stage Ib, IIa, IIb, and IIIb were 0$\%$, 33.3$\%$, 57.9$\%$, and 60$\%$, respectively. Distant metastasis rates were 0$\%$, 33.3$\%$, 21.1$\%$, and 40$\%$ for stage Ib, IIa, IIb, and IIIb, respectively. Especially the 6 patients who were irradiated with extended field to treat the paraaortic nodes were free of distant metastasis all. But, 9 patients (23.1$\%$) of the 39 patients who were not irradiated the paraaortic nodes were suffered and expired from uncontrolled distant metastasis. Conclusions : As compared with other studies, the survival rates were similar, but distant metastasis rates including paraaortic nodes metastasis were likely somewhat higher than expected, especially for patients with stage II. So, we think that the effect of prophylactic paraaortic nodes irradiation should be studied prospectively, especially for patients with pelvic nodes involvement or advanced stage of disease.

  • PDF

Postoperative External Beam Radiotherapy for Retroperitoneal Soft Tissue Sarcoma (후복막 연조직 육종의 수술 후 외부 방사선 치료)

  • Jang, Na-Young;Kim, Il-Han;Choi, Jin-Hwa;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.26 no.3
    • /
    • pp.135-141
    • /
    • 2008
  • Purpose: To evaluate the clinical outcomes and prognostic factors in retroperitoneal soft tissue sarcomas treated by postoperative radiotherapy. Materials and Methods: The records of 23 patients with retroperitoneal soft tissue sarcomas, who underwent postoperative radiotherapy between 1985 and 2003, were analyzed. The median follow-up period was 77 months (range, $8{\sim}240$ months). A total of 21 patients presented with primary disease, and two patients presented with recurrent disease. Liposarcomas and leiomyosarcomas represented 78% of the diagnosed tumor cases. Moreover, 17 cases were of high grade (grade 2 or 3). The median tumor size was 13 cm (range, $3{\sim}50\;cm$). Complete excision was achieved in 65% of patients. The median radiation dose was 50.4 Gy (range, 45.0 to 59.4 Gy), with conventional fractionation. Results: The 5-year overall, local recurrence-free, and distant metastasis-free survival rates were 68%, 58%, and 71%, respectively. Eleven patients experienced local recurrence, while 9 patients experienced distant metastasis. The most common site for distant metastasis was the liver. A univariate analysis revealed that adjacent organ invasion and age (>60 years) as the significant risk factors contributing to the prediction of poor overall survival. Moreover, multivariate analyses indicated that adjacent organ invasion remained significantly associated with a higher risk of death. In addition, patient age (>60 years) was the other identified risk factor for local recurrence by univariate and multivariate analyses. Except for one case of grade 3 diarrhea, no patient suffered grade 3 or higher complications. Conclusion: Our results were comparable to previous reports in that adjacent organ invasion and patient age (>60 years) were significant predictors of poor survival and tumor recurrence, respectively.

Effect of Storage Temperature and Water Activity on Antioxidant Activities of Powdered Green Tea Extracts (분말녹차 추출물의 항산화 활성에 미치는 수분활성도 및 저장온도의 효과)

  • Choi, Gwi-Nam;Jeong, Chang-Ho;Kim, Ji-Hye;Kwak, Ji-Hyun;Shin, Young-Hee;Lee, Seung-Cheol;Cho, Sung-Hwan;Choi, Sung-Gil;Heo, Ho-Jin
    • Food Science and Preservation
    • /
    • v.16 no.3
    • /
    • pp.333-341
    • /
    • 2009
  • The antioxidant properties of green tea leaves and powder extracts were determined using several tests including estimation of reducing power, DPPH(1,1-diphenyl-2- picrylhydrazyl) radical-scavenging activity, and FRAP(Ferric reducing/antioxidant power) assay. All tests indicated that extracts of green tea powder had higher antioxidant activities than extracts of green tea leaves, and the activities were concentration-dependent. However, each test yielded somewhat different results with respect to storage conditions. The reducing power of green tea leaves was highest at $1,000{\mu}g/mL$, storage at $4^{\circ}C$, and an Aw(water activity) value of 0.23. However, the reducing power of green tea powder, assayed at $1,000{\mu}g/mL$, was high under all storage conditions(with variations in temperature and Aw), and was about 1.5.2-fold greater than that of green tea leaves. Radical-scavenging activity, as assessed by the DPPH assay, increased in a dose-dependent manner over the range $15{\sim}125{\mu}g/mL$. At higher concentrations, activities were $80{\sim}90%$ of maximal were attained. The FRAP activity of green tea extract also increased with rising concentration. Particularly in the case of green tea leaves, antioxidant activity was most greatest with storage at $-20^{\circ}C$ and Aw values of 0.69 and 0.23 when assayed at a concentration of $1,000{\mu}g/mL$. These results indicate that the most important factor during storage of green tea is not the Aw value but rather temperature, and that use of refrigeration($4^{\circ}C$) is preferable to increase or maintain the antioxidant activities of biological components in green tea.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

STIMULATION OF OSTEOBLASTIC PHENOTYPES BY STRONTIUM IN PERIOSTEAL-DERIVED CELLS (골막기원세포에서 strontium에 의한 조골세포 표현형의 활성)

  • Kim, Shin-Won;Kim, Uk-Kyu;Park, Bong-Wook;Hah, Young-Sool;Cho, Hee-Young;Kim, Jung-Hwan;Kim, Deok-Ryong;Kim, Jong-Ryoul;Joo, Hyun-Ho;Byun, June-Ho
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.199-206
    • /
    • 2010
  • This study investigated the effects of strontium on osteoblastic phenotypes of cultured human periostealderived cells. Periosteal tissues were harvested from mandible during surgical extraction of lower impacted third molar. Periosteal-derived cells were introduced into cell culture. After passage 3, the periostealderived cells were further cultured for 28 days in an osteogenic induction DMEM medium supplemented with fetal bovine serum, ascorbic acid 2-phosphate, dexamethasone and at a density of $3{\times}10^4$ cells/well in a 6-well plate. In this culture medium, strontium at different concentrations (1, 5, 10, and 100 ${\mu}g$/mL) was added. The medium was changed every 3 days during the incubation period. We examined the cellular proliferation, histochemical detection and biochemical measurements of alkaline phosphatase (ALP), the RT-PCR analysis for ALP and osteocalcin, and von Kossa staining and calcium contents in the periostealderived cells. Cell proliferation was not associated with the addition of strontium in periosteal-derived cells. The ALP activity in the periosteal-derived cells was higher in 5, 10, and 100 ${\mu}g$/ml strontium-treated cells than in untreated cells at day 14 of culture. Among the strontium-treated cells, the ALP activity was appreciably higher in 100 ${\mu}g$/ml strontium-treated cells than in 5 and 10 ${\mu}g$/ml strontium-treated cells. The levels of ALP and osteocalcin mRNA in the periosteal-derived cells was also higher in strontium-treated cells than in untreated cells at day 14 of culture. Their levels were increased in a dose-dependent manner. Von Kossa-positive mineralization nodules were strongly observed in the 1 ${\mu}g$/ml strontium-treated cells at day 21 and 28 of culture. The calcium content in the periosteal-derived cells was also higher in 1 ${\mu}g$/ml strontium-treated cells at day 28 of culture. These results suggest that low concentration of strontium stimulates the osteoblastic phenotypes of more differentiated periosteal-derived cells, whereas high concentration of strontium stimulates the osteoblastic phenotypes of less differentiated periosteal-derived cells. The effects of strontium on osteoblastic phenotypes of periosteal-derived cells appear to be associated with differentiation-extent.

Accuracy of Spirometry at Predicting Restrictive Pulmonary Impairment (제한성 환기장애의 진단에서 폐활량검사의 정확성)

  • Ahn, Young Mee;Koh, Won-Jung;Kim, Cheol Hong;Lim, Seong Yong;An, Chang Hyeok;Suh, Gee Young;Chung, Man Pyo;Kim, Hojoong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.3
    • /
    • pp.330-337
    • /
    • 2003
  • Background : Low spirometric forced vital capacity(FVC) in conjunction with a normal or high ratio of the forced expiratory volume at 1 second to the forced vital capacity($FEV_1$/FVC%) has traditionally been classified as a restrictive abnormality. However, the gold-standard diagnosis of a restrictive pulmonary impairment requires a measurement of the total lung capacity (TLC). This study was performed to determine the predictive value of spirometric measurements of the FVC for diagnosing a restrictive pulmonary abnormality. Methods : Test results from 1,371 adult patients who undertook both spirometry and lung volume measurements on the same visit from January 1999 to December 2000 were enrolled in this study. The test values for the FVC, the TLC that was below 80% of predicted value, and a $FEV_1$/FVC% that was below 70%, were classified as being abnormal. Results : Of the 1,371 patients, 353 patients had a reduced a FVC. Of these patients, 186 patients had a reduced TLC. Therefore, the positive predictive value was 52.7%. Of the 196 patients with a normal $FEV_1$/FVC% and a reduced FVC, 148(75.5%) patients had a lower TLC. Thirty eight (24.2%) patients out of 157 patients with a low $FEV_1$/FVC% and a low FVC showed a restrictive defect. Conclusion : Spirometry is useful to rule out a restrictive pulmonary abnormality, but a restrictive pattern on the spirometry dose not mean there is a true restrictive disease. For the patients with a low FVC, TLC measurements are essential for diagnosing a restrictive pulmonary impairment.