• 제목/요약/키워드: High delta fiber

검색결과 40건 처리시간 0.024초

표준 단일모드 광섬유와 하이델타 광섬유사이의 저 손실 접속 기법 (Low Splicing Loss Technique between Standard Single Mode Fiber and High Δ Fiber)

  • 김광택;양병철
    • 한국광학회지
    • /
    • 제19권3호
    • /
    • pp.169-174
    • /
    • 2008
  • 열처리에 의한 광섬유 코어의 모드 확산과 모드 진화 현상을 이용하여 일반 통신용 단일모드 광섬유와 하이텔타(high ${\Delta}$) 광섬유 사이의 접속 손실을 줄일 수 있는 기법들을 제시하였다. 실험결과는 하이텔타 광섬유의 적절한 열처리를 통해 기계적 접속 손실이 2.3 dB에서 0.1 dB까지 감소함을 나타내었다. 반면 융착접속 후 접속 부위에 전기 방전이나 산소 불꽃으로 열을 인가하는 방법으로 $0.2{\sim}0.4dB$ 정도의 접속 손실을 달성하였다.

CGRP, SP의 국소도포와 전기자국에 의한 고양이 치수신경활동의 변화 (CHANGES IN INTRADENTAL NERVE ACTIVITY FOLLOWING LOCAL APPLICATION OF CGRP, SP AND ELECTRICAL STIMULI IN CATS)

  • 김미자;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.527-537
    • /
    • 1995
  • The effect of calcitonin gene-related peptide (CGRP), substance P (SP) and electrical stimulation of the tooth on the intradental nerve activtiy (INA) was investigated in anesthetized cats. The INA was recorded from single pulp nerve units dissected from the inferior alveolar nerve under stereomicroscope. The INA elicited by 3 minute application of 4M NaCl in deep dentinal cavity was compared before and after stimulation at 10 minute intervals. The magnitude of INA was calculated as the total number of nerve impulses produced in given period, and the changes of INA are expressed as % of control INA. The results obtained were as follows. 1. 16 single pulp nerve units were classified as 14 $A{\delta}$-fibers (3.4~19.4m/sec) and 2-fibers (1.5~1.7m/sec) according to the conduction velocity. 2. 4M NaCl evoked an irregular bursts of spikes which continued until washing out. Isotonic saline did not affect INA to subsequent applications of the hypertonic NaCl solution (P>0.05). 3. Local application of CGRP ($200{\mu}g$/ml) in deep dentinal cavity reduced the INA induced by 4M NaCl in $A{\delta}$-fiber units (P<0.01) and some units of those responded to CGRP during application. 4. Local application of SP ($100{\mu}g$/ml) in deep dentinal cavity reduced the INA induced by 4M NaCl in AS-fiber units (p<0.05), but increased the INA in C-fiber unit coincided with large reduction of the INA of $A{\delta}$-fiber units. 5. Monopolar electrical stimulation applied to the crown at intensities high enough to excite C-fibers (12V, 5ms, 10Hz, 10~30min) decreased the INA in $A{\delta}$-fiber units (P<0.01) and systemic pretreatment with phenoxybenzamine (3mg/kg, i.v.) enhanced this inhibitory effect (P<0.01). On the contrary, electrical stimulation increased the INA in C-fiber unit.

  • PDF

반용융 가공법에 의한 $\delta$-Al$_2$O$_3$/Aluminum 복합재료의 강도 특성 (Characteristic Strength of $\delta$-Al$_2$O$_3$/Aluminum Composite by Rheo-compocasting)

  • 이상필;김만수;김석호;윤한기
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1995년도 특별강연 및 춘계학술발표 개요집
    • /
    • pp.155-159
    • /
    • 1995
  • A16061 alloy reinforced with 10 vol% $\delta$-A1$_2$O$_3$ short fiber have been fabricated by Rheo-compocasting and squeeze casting and extruded at high temperature using conical shape die and curved shape die with various extrusion ratios.. Tensile and hardness tests were carried out to examine mechanical properties of extruded materials and SEM observation of fractured surface was capable of accounting for fracture mechanism and bonding state of fiber and matrix.

  • PDF

자동차 브레이크용 마찰재 내의 강철섬유, 지르콘, 캐슈가 크립 그론에 미치는 영향 (Effects of Steel Fiber, Zircon, and Cashew in the Brake Friction Materials on Creep Groan Phenomena)

  • 장호;이강선;이은주;정근중;송현우
    • Tribology and Lubricants
    • /
    • 제23권6호
    • /
    • pp.278-282
    • /
    • 2007
  • Friction characteristics of a low-steel friction material were examined to investigate creep groan phenomena. The amount of three ingredients (steel fiber, $ZrSiO_4$, cashew) were changed to produce test specimens using a constrained mixture design. Tribological properties of the friction material specimens were obtained by using a 1/5 scale dynamometer. Results showed that the amount of three different ingredients strongly affected the level of friction coefficient and the difference between the static friction coefficient and the kinetic friction coefficient $({\Delta}{\mu}).\;ZrSiO_4$ and steel fiber tended to increase the average friction coefficient and aggravated the stick-slip phenomena suggesting high creep groan propensity. On the other hand, cashew tended to decrease average friction coefficient and ${\Delta}{\mu}$.

복합소재 바닥판 '델타데크' 개발과 부상항 눌차교의 세계 최대규모 적용사례 연구 (Development of Composite Deck 'Delta Deck' and its World Largest Application for Noolcha Bridge, Busan Port)

  • 이성우;홍기증;김제인;조남훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.545-550
    • /
    • 2007
  • Due to many advantages such as lightweight, high durability and speedy construction, increasing number of bridges of various girder types are being built recently with glass-fiber reinforced composite deck. A profile of the composite deck, called 'Delta deck', is developed which has 3 trapezoidal cells of 200mm depth. This paper introduces how to develop 'Delta deck' and its application to the world largest composite-deck bridge, which is 300m long and 35m wide and is currently under construction.

  • PDF

Color stability of laboratory glass-fiber-reinforced plastics for esthetic orthodontic wires

  • Inami, Toshihiro;Tanimoto, Yasuhiro;Minami, Naomi;Yamaguchi, Masaru;Kasai, Kazutaka
    • 대한치과교정학회지
    • /
    • 제45권3호
    • /
    • pp.130-135
    • /
    • 2015
  • Objective: In our previous study, glass-fiber-reinforced plastics (GFRPs) made from polycarbonate and glass fibers were prepared for esthetic orthodontic wires using pultrusion. These laboratory GFRP wires are more transparent than the commercially available nickel-titanium wire; however, an investigation of the color stability of GFRP during orthodontic treatment is needed. Accordingly, in the present study, the color stability of GFRP was assessed using colorimetry. Methods: Preparation of GFRP esthetic round wires (diameter: 0.45 mm [0.018 inch]) using pultrusion was described previously. Here, to investigate how the diameter of fiber reinforcement affects color stability, GFRPs were prepared by incorporating either $13-{\mu}m$ (GFRP-13) or $7-{\mu}m$ glass (GFRP-7) fibers. The color changes of GFRPs after 24 h, and following 1, 2, and 4 weeks of coffee immersion at $37^{\circ}C$, were measured by colorimetry. We evaluated the color stability of GFRPs by two evaluating units: the color difference (${\Delta}E^*$) and National Bureau of Standards (NBS). Results: After immersion, both GFRPs showed almost no visible color change. According to the colorimetry measurements, the ${\Delta}E^*$ values of GFRP-13 and GFRP-7 were 0.73-1.16, and 0.62-1.10, respectively. In accordance with NBS units, both GFRPs showed "slight" color changes. As a result, there were no significant differences in the ${\Delta}E^*$ values or NBS units for GFRP-13 or GFRP-7. Moreover, for both GFRPs, no significant differences were observed in any of the immersion periods. Conclusions: Our findings suggest that the GFRPs will maintain high color stability during orthodontic treatment, and are an attractive prospect as esthetic orthodontic wires.

전침자극이 흰쥐척수후각세포의 유해자극반응에 미치는 효과의 특성 (Characterization of Electroacupuncture Effects on the Responses of Rat Dorsal Horn Neurons to Noxious Stimulation)

  • 신홍기;박동석;이서은;김진혁
    • Journal of Acupuncture Research
    • /
    • 제19권4호
    • /
    • pp.167-182
    • /
    • 2002
  • This experiment was designed to investigate the effects of electroacupuncture (EA) on chronic pains and factors that affected EA effects. The responses of wide dynamic range (WDR) cells to electrical stimulation of $A{\delta}$ & C afferent fibers were used as an index of pain in rats with chronic pains induced by intraplantar injection of complete Freund's adjuvant or peripheral nerve injury. In rats with chronic pains, low (2Hz) and high (100Hz) frequency EA stimulation applied to zusanli caused the inhibition of WDR cell responses in about 60% of rats and the inhibitory actions were dependent on the stimulus strength. EA stimulation also induced an excitation of WDR cell responses in 23.9% of rats and no effect in 15.8% of rats. However, it seemed that in normal rats compared to the rat with chronic pains, the incidence of which EA stimulation caused the excitation or no effect was high. Reversible spinalization almost completely blocked EA-induced inhibitory or excitatory effects. EA stimulation more frequently induced the excitation of WDR cell responses in lightly anesthetized (0.6%) rats and the enhanced responses of WDR cells were inhibited by EA stimulation in the rat anesthetized with 1.5% enflurane. These experimental findings suggest that in rats with chronic pain, EA stimulation inhibited WDR cell responses to slow $A{\delta}$ and C fiber stimulation and EA-induced inhibitory action was under the control of descending inhibitory system and degree of anesthesia.

  • PDF

Effects of High Concentrations of Naftopidil on Dorsal Root-Evoked Excitatory Synaptic Transmissions in Substantia Gelatinosa Neurons In Vitro

  • Uta, Daisuke;Hattori, Tsuyoshi;Yoshimura, Megumu
    • International Neurourology Journal
    • /
    • 제22권4호
    • /
    • pp.252-259
    • /
    • 2018
  • Purpose: Naftopidil ((${\pm}$)-1-[4-(2-methoxyphenyl) piperazinyl]-3-(1-naphthyloxy) propan-2-ol) is prescribed in several Asian countries for lower urinary tract symptoms suggestive of benign prostatic hyperplasia. Previous animal experiments showed that intrathecal injection of naftopidil abolished rhythmic bladder contraction in vivo. Naftopidil facilitated spontaneous inhibitory postsynaptic currents in substantia gelatinosa (SG) neurons in spinal cord slices. These results suggest that naftopidil may suppress the micturition reflex at the spinal cord level. However, the effect of naftopidil on evoked excitatory postsynaptic currents (EPSCs) in SG neurons remains to be elucidated. Methods: Male Sprague-Dawley rats at 6 to 8 weeks old were used. Whole-cell patch-clamp recordings were made using SG neurons in spinal cord slices isolated from adult rats. Evoked EPSCs were analyzed in $A{\delta}$ or C fibers. Naftopidil or prazosin, an ${\alpha}1$-adrenoceptor blocker, was perfused at $100{\mu}M$ or $10{\mu}M$, respectively. Results: Bath-applied $100{\mu}M$ naftopidil significantly decreased the peak amplitudes of $A{\delta}$ and C fiber-evoked EPSCs to $72.0%{\pm}7.1%$ (n=15) and $70.0%{\pm}5.5%$ (n=20), respectively, in a reversible and reproducible manner. Bath application of $100{\mu}M$ prazosin did not inhibit $A{\delta}$ or C fiber-evoked EPSCs. Conclusions: The present study suggests that a high concentration of naftopidil reduces the amplitude of evoked EPSCs via a mechanism that apparently does not involve ${\alpha}1$-adrenoceptors. Inhibition of evoked EPSCs may also contribute to suppression of the micturition reflex, together with nociceptive stimulation.

Broad and stage-based sensing function of HCFRP sensors

  • Wu, Z.S.;Yang, C.Q.
    • Smart Structures and Systems
    • /
    • 제3권2호
    • /
    • pp.133-146
    • /
    • 2007
  • This paper addresses a new type of broad and stage-based hybrid carbon fiber reinforced polymer (HCFRP) sensor that is suitable for the sensing of infrastructures. The HCFRP sensors, a type of composite sensor, are fabricated with three types of carbon tows of different strength and moduli. For all of the specimens, the active materials are carbon tows by virtue of their electrical conductivity and piezoresistivity. The measurement principles are based on the micro- and macro-fractures of different types of carbon tows. A series of experiments are carried out to investigate the sensing performances of the HCFRP sensors. The main variables include the stack order and volume fractions of different types of carbon tows. It is shown that the change in electrical resistance is in direct proportion to the strain/load in low strain ranges. However, the fractional change in electrical resistance (${\Delta}R/R_0$) is smaller than 2% prior to the macrofractures of carbon tows. In order to improve the resistance changes, measures are taken that can enhance the values of ${\Delta}R/R_0$ by more than 2 times during low strain ranges. In high strain ranges, the electrical resistance changes markedly with strain/load in a step-wise manner due to the gradual ruptures of different types of carbon tows at different strain amplitudes. The values of ${\Delta}R/R_0$ due to the fracture of high modulus carbon tows are larger than 36%. Thus, it is demonstrated that the HCFRP sensors have a broad and stage-based sensing capability.

치아임플란트 시술 후 삼차신경에서의 전류인지역치에 대한 연구 (A Study of Current Perception Threshold of Trigeminal Nerve after Tooth Implantation)

  • 임현대;이정현;이유미
    • Journal of Oral Medicine and Pain
    • /
    • 제32권2호
    • /
    • pp.187-200
    • /
    • 2007
  • 이 연구는 치과임플란트 시술후에 발생할수 있는 감각이상의 평가를 위하여 뉴로미터를 사용하여 정량적으로 측정하여, 임플란트 시술후의 감각신경 평가에 개관적 지침을 마련하고자 하는데 목적이 있다. 2006년 대전 썬 병원 구강내과에 내원한 환자중에 임플란트 술식을 시행한 환자 44명과 대조군 30명을 대상으로 $Neurometer^{(R)}$ CPT/C (Neurotron, Inc., Baltimore, Maryland, U.S.A.)를 이용하여 임플란트 시술전과 시술후 발사시에 2000 Hz, 250 Hz, 5 Hz,주파수로 검사를 시행하였다. 측정 부위는 임플란트 시술부위에 따라 삼차신경의 상악신경 분지와 하악신경 분지에 적용하였다. Neurometer는 세가지의 주파수 (2000 Hz, 250 Hz, 5 Hz)를 적용할 수 있는데, 각 주파수별로 대상자가 감각을 느낄 수 있는 가장 낮은 전류의 세기를 전류인지역치로 기록하였다. 각 신경섬유별 전류인지역치는 $A{\beta}$섬유의 경우 2000 Hz, $A{\delta}$섬유의 경우 250 Hz의 전류자극 하에서 특징적으로 반응하며, C섬유의 경우 5 Hz의 전류자극 하에서 반응한다. 전류인지역치 검사는 삼차신경 영역에 있어서도 말초신경 손상을 평가하기 위하여 검사를 시행할 수 있으며, 말초신경부위에 특징적인 주파수의 전류를 발생시켜 선택적인 신경 섬유를 자극한다. 서로 다른 굵기의 신경 섬유들은 각기 다른 빈도의 전류자극에 선택적으로 반응하는데, 각기 다른 주파수의 전류자극을 적용하며, 각 전류에 선택적으로 반응하는 $A{\beta},\;A{\delta}$, C신경 섬유의 반응 역치를 개별적으로 평가할 수 있다. 전류인지역치를 통한 평가에서는 전류인지 역치의 증감을 측정하여 감각과민이나 감각감퇴등의 감각이상을 진단할 수 있다. 임플란트 시술전후의 전류인지역치를 평가한 본 연구에서는 다음과 같은 결과를 얻었다. 1. 임플란트 시술 전후의 평가에서는 좌우 상하악 각각의 2000 Hz, 250 Hz, 5 Hz에서의 전류인지역치는 전반적으로 수술 후가 증가되었으며, 하악에서는 2000 Hz와 5 Hz에서 수술후에의 전류인지역치가 통계학적으로 유의하게 증가하였다. 2. 전신질환을 가지고있거나 그로 인하여 투약중인 군에서는 임플란트 수술 전후에 유의한 차이가 없었으며, 대조군에 비해서는 좌측 2000 Hz와 5 Hz에서 임플란트 시술군이 전류인지역치가 유의하게 높았다. 3. 대조군과 임플란트 수술군의 수술전의 전류인지역치 측정치의 비교에서는 우측 2000 Hz, 5 Hz에서 임플란트 시술군이 유의하게 높았으며, 대조군과 임플란트 수술후의 전류 인지 역치 평가에서는 2000 Hz에서 유의한 차이를 보였다. 4. 남자가 여자보다는 전류인지역치가 높았으나, 통계학적인 유의성을 보이지는 않았으며, 임플란트 시술군내에서도 남녀차이는 보이지 않았으며, 대조군에서 좌측 2000 Hz에서 유의하게 낮았다. 임플란트 시술 전후의 전류인지 평가에서 남녀성별에 따른 차이는 남자군에서는 통계학적 차이가 없었고, 여자군에서 우측 5 Hz, 좌측 2000 Hz에서 유의하게 높았다. 5. 감각신경이 있다고 호소하는 군과 아닌 군과의 비교에서는 감각이상을 호소하는 군이 전체적으로 전류인지역치가 증가했으나 통계학적인 유의성은 없었다. VAS상에 증가를 보이는 군의 수술전후의 전류인지측정 평가에서는 우측 5 Hz에서 임플란트 시술후 전류인지역치가 유의하게 증가하였으며, VAS 표시가 수술전후에 모두 0 인 경우에 좌측 2000 Hz에서 수술후의 전류인지역치가 유의하게 증가하였다. 이 연구는 뉴로미터를 이용하여 치아 임플란트 시술후에 발생할 수 있는 감각이상을 평가 할수 있는 객관적이고 정량적인 전류인지역치를 제시하고자 하였다.