• 제목/요약/키워드: High current measuring

검색결과 478건 처리시간 0.026초

고압 대전류 아크의 복사강도 측정 (Measurement of Radiation Intensity of the High-Pressure and Large-Current Arc)

  • 송기동;오연호;정진교;조용성
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권11호
    • /
    • pp.555-563
    • /
    • 2006
  • This paper presents the measured radiation intensity of high-pressure and large-current arc with the current. In order to measure the radiation intensity of large-current arc, a model circuit breaker was specially designed and manufactured and the method using an astronomical telescope was utilized after various measuring methods were investigated. A trigger system was designed and fabricated to coincide the time of desired current with the exposure time of 1ms of the spectroscope. A high-speed camera was used to investigate the shape and behavior of the arc and the captured results have been used to calculate the radiation energy. The calculated arc temperature with Boltzmann plot method using the measured radiation intensity have $18,000{\sim}27,000K$ to the current $4kA{\sim}15kA$. And also, using the calculated arc temperature and the captured arc shape the radiation energy of the current $5kA{\sim}15kA$ were calculated with $8{\times}10^5{\sim}4.0{\times}10^6W/m$ respectively.

지하철 전력 시스템 대한 상태추정 (State Estimation in Subway Power Systems)

  • 류헌수;하운관;문영현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권1호
    • /
    • pp.29-36
    • /
    • 2002
  • It is required that the current state of system should be Precisely monitored for efficient and safe operation of the subway power system and it is an important Problem to secure the high quality data for state estimation. The current state of subway power system is estimated by using data transmitted to control center from every measuring instrument. The high accuracy and trust can be maintained if the measured data have a high quality. But it is difficult to estimate the accurate state of system because of the noises in transmitted data and the inaccuracy of measuring instruments. So the object is to reduce the difference between the real values and the measured values in order to improve considerably the inaccuracy due to Instrumental errors and transmission noises using the state estimation method. In this paper, we proposes a new state estimation to estimate the accurate state of the subway power system from the measured values of a Sang-In station in Daegu subway and consider the possibility of application to the real subway power system. on the basis of that. The simulation results show to make sure of the possibility to apply to the real system usefully.

교류 전동기의 고효율 운전을 위한 3상 인버터의 입력전력 추정 기법 (Input Power Estimation Method of a Three-phase Inverter for High Efficiency Operation of an AC Motor)

  • 김도현;김상훈
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.445-451
    • /
    • 2019
  • An input power estimation method of a three-phase inverter for the high-efficiency operation of AC motors is proposed. Measuring devices, such as DC link voltage and input current sensors, are required to obtain the input power of the inverter. In the proposed method, the input power of the inverter can be estimated without the input current sensor by using the phase current information of the AC motor and the switching pattern of the inverter. The proposed method is more robust to parameter error than conventional method. The validity of the input power estimation method is verified through experiments conducted on a 1 kW permanent-magnet synchronous motor drive system.

로드셀을 이용한 밀링 가공시의 절삭력 측정시스템 (Cutting Force Measuring System Using the Load Cell for a Milling Process)

  • 강은구;박성준;이상조;권혁동
    • 한국정밀공학회지
    • /
    • 제18권6호
    • /
    • pp.133-140
    • /
    • 2001
  • This paper suggests another system for a cutting force measuring tool in a milling process. Generally, tool dynamometer is taken into account for the most appropriate cutting force measuring tool in the analysis of cutting mechanism. However, high price and limited space make it difficult to be in-situ system for controllable milling process. Although an alternative method using AC current of servo-motor has been suggested, it is unsuitable for cutting force control because of small upper frequency limit and noise. The cutting force measuring system is composed of two load cells placed between the moving table bracket and the nut flange part of ballscrew. It has many advantages such as low cost and wide range measurement than tool dynamometer because of the built-in moving table and the low cost load cell. The static and dynamic model of the measuring system using imbeded load cell is introduced. Various Experiments are carried out to validate both models. By comparing the cutting forces from a series of end milling experiments on the tool dynamometer and the system developed in this paper, the accuracy of the cutting force measuring system is verified. Upper frequency limit is measured by the experiment of dynamic characteristics.

  • PDF

FPGA SoC를 이용한 네모파 전압전류법의 주파수 변화에 따른 계측 분석 (Determination of Frequency for decision of heavy metal ion concentration in Square Wave Voltammetry with FPGA SoC)

  • 이재춘
    • 디지털산업정보학회논문지
    • /
    • 제14권4호
    • /
    • pp.101-107
    • /
    • 2018
  • In the stripping scan square wave voltammetry (SV+SWV) polarography that is often used to analyze the concentration of heavy metals in water, we must measure the point where the faradic current that flows by the pure oxidation-reduction reaction at the electrode is greater than the capacitive current, the frequency cannot be too high. Therefore we wanted to find the frequency range that can be measured. In order to do this, we came up with a method to analyze the signal using FPGA Soc. With this method, the frequency of the square wave was increased from 10Hz to 400Hz by 10Hz, and the measuring time of the square wave was changed from 96.695% to 96.765% by 0.005% while 1600 experiments were conducted. As a result, the frequency of the square wave maintained a stable area of potential-current within 320Hz and it was possible to measure the potential-current signal when calculating the measuring time within the frequency range of 96.7155%.

Influencing Factors on Dynamic Characteristics of Pantograph of Korean High Speed Train

  • Eom, Beom-Gyu;Mok, Jin-Yong;Lee, Hi-Sung
    • International Journal of Railway
    • /
    • 제2권4호
    • /
    • pp.187-192
    • /
    • 2009
  • Running test of the Korean High-Speed Train using remote controlled measuring system have been executed on the high speed track in order to evaluate and verify the performance of the train. In this paper, influencing factors on the contact force which represents dynamic characteristics between the pantograph and contact wire are analyzed, according to the track condition, span type and running condition. By the analytical study on the test data, we figured out that contact force and dynamic characteristics of the pantograph are mainly affected by running behavior of the train and the span distance which the train passes.

  • PDF

피부전류량의 화상중첩에 의한 경혈의 시각화 (Visualization of Acupoint by Image Overlapping of Skin Current)

  • 이용흠;김용진;고수복;정동명
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.563-566
    • /
    • 1999
  • The functional diagnosis instrument should be preceded first to both the accurate selection of exact acupoint and discrimination. so the measuring and stimulating method are improved to SPAC pattern to evaluate impedance existed in the body. As a result, the resistance factor between skin and probe, the dipolization of cell was reduced so that the judgement of acupoint is advanced. After extraction of optimization parameter of SPAC pattern which the high discrimination efficiency and the lowest affection on the human body is controlled by using microprocessor to enhance conviction. The discrimination efficiency was confirmed by meridian visualization system. Also mechanism of probe was improved to increase efficiency of image recognition processing. The image of discriminated acupoint with probe is obtained by using a camera, the location on the tip of probe is recognized and processed. And then these are converted to virtual color by proportional to measuring current level of scan point on skin.

  • PDF

지중선로의 분포 온도 측정 시스템 개발 (Development of optical temperature distribution measurement system for Underground Power Transmission tunnel)

  • 이근양;송우성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.766-768
    • /
    • 1998
  • Optical Temperature Distribution measurement System (OTDS) is completely different from conventional electric point sensor in that it uses the optical fiber itself as the sensor. This new concept in temperature measuring system requires only one fiber to be laid. The use of optical fiber also gives the advantage of small diameter, light weight, explosion resistance, and electromagnetic noise resistance. The OTDS is a sensor which is capable of making a precise measurement over a wide range of areas using only a single optical fiber. Since current temperature sensors, such as the thermocouple, are only used to measure temperaturea of point, they are almost impractical for measuring a wider range because of the extremely high cost. In comparision with current sensors, the optical fiber distributed temperature sensor can make much quicker and more precise measurements at a comparatively low cost.

  • PDF

생체박막의 전기특성에 관한 연구 (A Study on the Electrical Properties of Biology Thin)

  • 오재한;김동관;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.243-246
    • /
    • 1999
  • The displacement current measuring system used for detecting the dynamic behavior of monolayers at the air-water interface is described. It basically consists of a film balance, a pair of electrodes connected to each other through a sensitive ammeter. Here, one electrode is suspended in air and the other electrode is the water, With Maxwll-displacement-current-measuring method, the phase transitions of Poly(λ-benzyl- L-glutamate)(PBLG) on a water surface were detected, Displacement currents generated during the compression of monolayers of PBLG on the surface of water were investigated. As results, the displacement pick was generated when the area per molecule was about 15 $\AA$$^{2}$ in low pressure, and tit was generarted when the area per molecule about 27$\AA$$^{2}$ in high pressure.

  • PDF

Electrical Parameter Tests of Synchronous Reluctance Motor

  • Khang, Huynh Van;Hwang, Seon-Hwan;Kim, Jang-Mok;Ahn, Jin-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.211-213
    • /
    • 2007
  • The electrical parameters are used to calculate gains in the current regulator as well as to determine the reference currents of speed controller in various control strategies of Synchronous Reluctance Motors (SynRMs). Many methods of measuring or estimating the electrical parameters of SynRM have been proposed by other authors. But almost papers only measure or estimate in the limited conditions without fully considering the effects of inverter, connecting wire and magnetic saturation. The parameter results are usually different from the real system parameters. The drive performance, therefore, can not be good if using inaccurate parameters. In this paper, several methods used to measure the electrical parameters are introduced. The first method is LCR meter. And then, a method determining inductances by measuring AC current and voltage from AC power supply is presented. A new method with high reliability is proposed to measure the electrical parameters of SynRM. The experiment results verify the effectiveness of the new proposed method.

  • PDF