• 제목/요약/키워드: High and%2For Low Temperature Region

검색결과 278건 처리시간 0.035초

PNU CGCM과 WRF를 이용한 남한 지역 기온 예측성 검증 (Predictability of Temperature over South Korea in PNU CGCM and WRF Hindcast)

  • 안중배;심교문;정명표;정하규;김영현;김응섭
    • 대기
    • /
    • 제28권4호
    • /
    • pp.479-490
    • /
    • 2018
  • This study assesses the prediction skill of regional scale model for the mean temperature anomaly over South Korea produced by Pusan National University Coupled General Circulation Model (PNU CGCM)-Weather Research and Forecasting (WRF) chain. The initial and boundary conditions of WRF are derived from PNU CGCM. The hindcast period is 11 years from 2007 to 2017. The model's prediction skill of mean temperature anomaly is evaluated in terms of the temporal correlation coefficient (TCC), root mean square error (RMSE) and skill scores which are Heidke skill score (HSS), hit rate (HR), false alarm rate (FAR). The predictions of WRF and PNU CGCM are overall similar to observation (OBS). However, TCC of WRF with OBS is higher than that of PNU CGCM and the variation of mean temperature is more comparable to OBS than that of PNU CGCM. The prediction skill of WRF is higher in March and April but lower in October to December. HSS is as high as above 0.25 and HR (FAR) is as high (low) as above (below) 0.35 in 2-month lead time. According to the spatial distribution of HSS, predictability is not concentrated in a specific region but homogeneously spread throughout the whole region of South Korea.

2012년 겨울철 특별관측자료를 이용한 강수현상 시 대기 연직구조와 민감도 실험 (Vertical Atmospheric Structure and Sensitivity Experiments of Precipitation Events Using Winter Intensive Observation Data in 2012)

  • 이상민;심재관;황윤정;김연희;하종철;이용희;정관영
    • 대기
    • /
    • 제23권2호
    • /
    • pp.187-204
    • /
    • 2013
  • This study analyzed the synoptic distribution and vertical structure about four cases of precipitation occurrences using NCEP/NCAR reanalysis data and upper level data of winter intensive observation to be performed by National Institute of Meteorological Research at Bukgangneung, Incheon, Boseong during 63days from 4 JAN to 6 MAR in 2012, and Observing System Experiment (OSE) using 3DVAR-WRF system was conducted to examine the precipitation predictability of upper level data at western and southern coastal regions. The synoptic characteristics of selected precipitation occurrences were investigated as causes for 1) rainfall events with effect of moisture convergence owing to low pressure passing through south sea on 19 JAN, 2) snowfall events due to moisture inflowing from yellow sea with propagation of Siberian high pressure after low pressure passage over middle northern region on 31 JAN, 3) rainfall event with effect of weak pressure trough in west low and east high pressure system on 25 FEB, 4) rainfall event due to moisture inflow according to low pressures over Bohai bay and south eastern sea on 5 MAR. However, it is identified that vertical structure of atmosphere had different characteristics with heavy rainfall system in summer. Firstly, depth of convection was narrow due to absence of moisture convergence and strong ascending air current in middle layer. Secondly, warm air advection by veering wind with height only existed in low layer. Thirdly, unstable layer was limited in the narrow depth due to low surface temperature although it formed, and also values of instability indices were not high. Fourthly, total water vapor amounts containing into atmosphere was small due to low temperature distribution so that precipitable water vapor could be little amounts. As result of OSE conducting with upper level data of Incheon and Boseong station, 12 hours accumulated precipitation distributions of control experiment and experiments with additional upper level data were similar with ones of observation data at 610 stations. Although Equitable Threat Scores (ETS) were different according to cases and thresholds, it was verified positive influence of upper level data for precipitation predictability as resulting with high improvement rates of 33.3% in experiment with upper level data of Incheon (INC_EXP), 85.7% in experiment with upper level data of Boseong (BOS_EXP), and 142.9% in experiment with upper level data of both Incheon and Boseong (INC_BOS_EXP) about accumulated precipitation more than 5 mm / 12 hours on 31 January 2012.

PEDOT를 이용한 CRT용 반사방지 및 대전방지 코팅 (An Antireflection and Antistatic Coatings for CRTs using PEDOT)

  • 김태영;김종은;이보현;서광석;김진열
    • 한국전기전자재료학회논문지
    • /
    • 제15권1호
    • /
    • pp.61-66
    • /
    • 2002
  • A method for designing antireflection (AR) and antistatic (AS) coating layer by the use of conducting polymer as an electrically conductive transparent layer is proposed. The conducting AR coating is composed of four-layer with alternating high and low refractive index layer: silicon dioxide (n=1.44) and titanium dioxide (n=2.02) prepared at low temperature by sol-gel method are used as the low and high refractive index layer, respectively. The poly(3,4-ethylenedioxythiophene) which has the surface resistivity of 10$^4$Ω/$\square$ is used as a conductive layer. Optical constant of each ARAS coating layers such as refractive index and optical thickness were measured by 7he spectroscopic ellipsometer and from the measured optical constants the spectral properties such as reflectance and transmittance were simulated in the risible region. The reflectance of ARAS films on glass substrate was below 1 %R and the transmittance was higher than 95 % in the visible wavelength (400-700 nm). The measured AR spectral properties was very similar to its simulated results.

한반도 서해 연안 해역에서의 해양 부이 관측 수온과 위성 마이크로파 관측 해수면온도의 비교 (Comparison of Sea Surface Temperature from Oceanic Buoys and Satellite Microwave Measurements in the Western Coastal Region of Korean Peninsula)

  • 김희영;박경애
    • 한국지구과학회지
    • /
    • 제39권6호
    • /
    • pp.555-567
    • /
    • 2018
  • 본 연구에서는 서해 연안에서의 실측-위성 해수면온도 차이를 규명하고 그 특성을 분석하기 위해 GCOM-W1/AMSR2 마이크로파 해수면온도 자료와 서해 연안에 위치한 덕적도, 칠발도, 외연도 해양기상 부이의 실측 수온 자료를 활용하여 2012년 7월부터 2017년 12월까지 총 6,457개의 일치점 자료를 생산하였다. 5년 이상의 덕적도, 칠발도, 외연도 해양 부이 수온 자료와 AMSR2 해수면온도를 비교하여 정확도를 제시하였다. 마이크로파 위성 해수면온도와 현장 관측 부이 해수면온도 간의 차이는 풍속과 수온 등 환경 요인에 대한 의존성을 가지는 것으로 나타났다. 낮시간 풍속이 약할 때 ($<6ms^{-1}$) AMSR2 해수면온도는 실측 해수면온도보다 높게 산출되며, 밤시간에 대해서는 풍속이 커질수록 양의 편차가 증가함을 밝혔다. 또한 AMSR2 해수면온도와 실측 해양부이 수온 간의 차이가 증가하는 경향은 낮은 온도에서 마이크로파 센서의 민감도의 저하와 육지에 의한 자료오염과 관련이 있는 것으로 나타났다. 실측-위성 해수면온도 차이를 월별로 도시해본 결과, 마이크로파 위성 해수면온도의 편차는 강한 바람이 부는 겨울철에 가장 커진다고 알려져 있던 기존의 경향성과는 달리 덕적도, 칠발도 부이에서는 여름철 가장 큰 해수면온도 편차값이 나타났다. 이러한 차이는 부이의 위치에 따른 조석 혼합의 공간적 차등에 기인한 것으로 사료된다. 본 연구는 인공위성 합성장에 기여도가 높은 마이크로파 위성 해수면온도를 사용할 때 한반도 서해안에서 발생할 수 있는 문제점과 제한점을 제시하였다.

초전도 $MgB_2$ 박막의 온도와 장기장의 변화에 따른 광학적 성질 (Temperature and magnetic field dependent optical properties of superconducting $MgB_2$ thin film)

  • 정종훈;이해자;김경완;김명훈;노태원;;강원남;정창욱;이성익
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.31-35
    • /
    • 2001
  • We investigated the temperature and magnetic field dependent optical properties of a$ MgB_2$ thin film in the far-infrared region. In the superconducting state, i.e. 5 K, we obtained the values of superconducting gap $2\Delta$ ~ 5.2 meV and $2\Delta$ $_{k}$ $B/T_{c}$ ~1.8. Although the value of$ 2\Delta$$B/T_{c}$ was nearly half of the BCS value, the $2\Delta$ seemed to follow the temperature dependence of the BCS formula. Under the magnetic field (H), the superconducting state became suppressed. Interestingly, we found that the normal state area fraction abruptly increased at low field but slowly increased at high field. It did not follow the H-dependences predicted for a s-wave superconductor (i.e. a linear dependence) nor for a s-wave one (i.e. $H^{1}$2/ dependence). We discussed the complex gap nature of $MgB_2$ in comparison with two gap and anisotropic s-wave scenarios.ios.

  • PDF

진공증착법을 이용하여 제조한 PVDF 유기 박막의 열적.전기적 안정 특성에 관한 연구 (A Study on the thermal and electrical stability of PVDF organic thin films fabricated by physical vapor deposition method.)

  • 박수홍;이덕출
    • 한국진공학회지
    • /
    • 제8권2호
    • /
    • pp.93-101
    • /
    • 1999
  • The purposed of this paper is to investigate the electrical and thermal stability of Polyvinylidene fluoride(PVDF) organic thin films prepared by the vapor deposition method. The differential scanning calorimetry curve of the PVDF organic thin films prepared by increasing substrate temperature showed that the melting curve increased from $128^{\circ}C$ to $142^{\circ}C$. This result implied that the PVDF organic thin film prepared by increasing substrate temperature increased intermolecular force in the crystalline region. The anomalous properties in dielectric constant and dielectric loss at low frequency and high temperature were described for PVDF organic thin film containing impurity carriers. It was confirmed that in view of electric conductive characteristics the ohm's law is satisfied in the range of lower electric field and ln J was proportional to the electric field ln E as like the conventional property of ionic conduction in the range of higher electric field. It was confirmed that major carrier of conductivity was ions. The electrical stability was improved according to an increase of the substrate temperature. On the basis of this experimental result, it could be observed that the optimum temperature of substrate for the electrical and thermal stability was at $105^{\circ}C$.

  • PDF

단층 초전도케이블 샘플에서 교류손실의 수치해석에 대한 연구 (A Study on Numerical Analysis of the AC Loss in a Single-layer Superconducting Cable Sample)

  • 이주영;마용호;류경우;황시돌
    • 한국전기전자재료학회논문지
    • /
    • 제22권7호
    • /
    • pp.606-611
    • /
    • 2009
  • AC loss is one of the important factors for commercialization of a high temperature superconducting (HTS) cable from an economic point of view. But AC loss characteristics of the HTS-cable are not elucidated completely because of its complex structure. As an earlier stage of analyzing the AC loss in the 22.9 kV/50 MVA, 100m HTS-cable system of Korea Electric Power Corporation (KEPCO) which is now in collaboration with us, a two-dimensional (2D) numerical model, which takes into account the nonlinear conductivity properties of a high temperature superconductor, has been developed. In order to examine our 2D model, we have prepared several single-layer cable samples whose AC losses are sufficiently reliable due to their simple structure. The AC losses of the samples were experimentally investigated and then compared with our 2D model. The results show that the numerically calculated AC losses are not in good agreement with the measured ones for the cylindrical cable and deca-cable samples with low critical current density. However, the numerically calculated and measured AC losses are relatively in good agreement for the deca-cable and hex-cable samples with high critical current density, although the difference between these two loss data in the deca-cable sample tends to increase in the low current region.

Bi-2223 고온초전도 전류리드의 제조 (Fabrication of Bi-2223 high-Tc superconducting current lead)

  • 하동우;오상수;류강식;장현만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1660-1662
    • /
    • 1996
  • Superconducting current lead is one of the promising applications of the oxide high-Tc superconductors, because they have the advantage of decreasing heat conduction to low temperature region, comparing with a conventional cooper alloy lead. High critical current density is a key factor for the applications such as current lead. $(Bi,Pb)_{2}Sr_{2}Ca_{2}Cu_{3}O_{x}$ high Tc superconductor hase been investigated in terms of critical current density. Bi-2223 superconducting current lead made by CIP and solid state sintering process. Bi-2223 current lead that heat treated at $836\;^{\circ}C$ for 240 h in 1/13 $PO_2$ had over $500\;A/cm^2$ of critical current density at 77K. We knew that the superconducting properties of tube type current leads were better than rods type of them. And we investigated the relation of Bi-2223 formation and heat treatment condition by XRD and SEM analysis.

  • PDF

부분 가열을 이용한 저온 Hermetic 패키징 (Low Temperature Hermetic Packaging using Localized Beating)

  • 심영대;김영일;신규호;좌성훈;문창렬;김용준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.1033-1036
    • /
    • 2002
  • Wafer bonding methods such as fusion and anodic bonding suffer from high temperature treatment, long processing time, and possible damage to the micro-scale sensor or actuators. In the localized bonding process, beating was conducted locally while the whole wafer is maintained at a relatively low temperature. But previous research of localized heating has some problems, such as non-uniform soldering due to non-uniform heating and micro crack formation on the glass capsule by thermal stress effect. To address this non-uniformity problem, a new heater configuration is being proposed. By keeping several points on the heater strip at calculated and constant potential, more uniform heating, hence more reliable wafer bonding could be achieved. The proposed scheme has been successfully demonstrated, and the result shows that it will be very useful in hermetic packaging. Less than 0.2 ㎫ contact Pressure were used for bonding with 150 ㎃ current input for 50${\mu}{\textrm}{m}$ width, 2${\mu}{\textrm}{m}$ height and 8mm $\times$ 8mm, 5mm$\times$5mm, 3mm $\times$ 3mm sized phosphorus-doped poly-silicon micro heater. The temperature can be raised at the bonding region to 80$0^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional micro heaters. For gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for gross leak check. The pass ratio of bonded dies was 70%, for conventional localized heating, and 85% for newly developed FP scheme. The bonding strength was more than 30㎫ for FP scheme packaging, which shows that FP scheme can be a good candidate for micro scale hermetic packaging.

  • PDF

수평미세관내 NH3 비등열전달 특성 (Boiling Heat Transfer of Ammonia inside Horizontal Smooth Small Tube)

  • 최광일;오종택
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.101-108
    • /
    • 2013
  • This paper is presented an experimental study of flow boiling heat transfer characteristics of ammonia, and is focused on pressure gradient and heat transfer coefficient of the refrigerant flow inside horizontal small tube with inner diameter of 3.0 mm and length of 2000 mm. The direct heating method is applied for supplying heat to the refrigerant, where the test tube is uniformly heated by electric current. The local heat transfer coefficients were obtained over a heat flux range of 20 to $80kW/m^2$, a mass flux range of 50 to $500kg/m^2s$, a saturation temperature range of 0 to $10^{\circ}C$, and quality up to 1.0. The pressure drops increase with increasing mass flux and heat flux, and with decreasing saturation temperature. The heat transfer coefficients increase with increasing mass flux and saturation temperature in middle and high quality region. And the local heat transfer coefficient increase with increasing heat flux in low quality region. The heat transfer coefficient of the experimental result was compared with six existing heat transfer coefficient correlation. A new boiling heat transfer coefficient correlation based on the superposition model for ammonia in small tubes is developed average deviation of -0.17% and mean deviation of 10.85%.