• Title/Summary/Keyword: High Volume

Search Result 6,439, Processing Time 0.029 seconds

Drying Shrinkage of High-Volume Fly Ash Concrete (High-Volume 플라이애쉬 콘크리트의 건조수축특성)

  • 최석균;이광명;이진용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.195-198
    • /
    • 1999
  • Fly ash is the most common artificial pozzolan, which is a material precipitated electrostatically from the exhaust gases of coal-fired power stations. Fly ash can be used as the supplementary material as well as the material for high performance concrete and hence, the development of high-volume fly ash concrete is imperative. In this study, the characteristics of drying shrinkage of high volume fly ash concrete is investigated. It is found from test results that as the replaced amount of fly ash in concrete is increased, drying shrinkage of concrete is reduced.

  • PDF

Evaluation of the Availability of the Wide Coverage Volume Axial Mode in Pediatric Cardiac CT (소아 심장 CT검사 시 Wide Coverage Volume Axial Mode의 유용성 평가)

  • Park, Ki Seok;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.683-689
    • /
    • 2019
  • We are trying to evaluate usefulness of Wide Coverage Volume Axial Mode by comparing and analyzing for exposure doses to patients and video quality extracted from two materials. First material is a computer tomography scanning of paediatric cardiac made by using High Pitch Mode, which is designed for diagnosing Congenital cardiac diseases. Second material is computer tomography scanning of paediatric cardiac made by using Wide Coverage Volume Axial Mode. When we did computer tomography scanning of paediatric cardiac, we used High Pitch Mode and Wide Coverage Volume Axial Mode to 50 patients of each, overall 100 patients. Also, we compared exposure doses to patients using videos got from each protocol. Then we compared video quality by calculating SNR and CNR by setting ROI of each. Not only exposure doses to patients were reduced by 13.07 %, but also SNR and CNR were improved when testing used Wide Coverage Volume Axial Mode rather than using High Pitch Mode. Wide Coverage Volume Axial Mode reduced testing time by using high-speed scanner. Furthermore, we can find out that Wide Coverage Volume Axial Mode is an useful method through improving video quality and reducing exposure doses to patients than using High Pitch Mode from ASiR-V, which is low-dose technology.

Rotator cuff retear after repair surgery: comparison between experienced and inexperienced surgeons

  • Park, Jin-Young;Lee, Jae-Hyung;Oh, Kyung-Soo;Chung, Seok Won;Choi, Yunseong;Yoon, Won-Yong;Kim, Dong-Wook
    • Clinics in Shoulder and Elbow
    • /
    • v.24 no.3
    • /
    • pp.135-140
    • /
    • 2021
  • Background: We hypothesized in this study that the characteristics of retear cases vary according to surgeon volume and that surgical outcomes differ between primary and revision arthroscopic rotator cuff repair (revisional ARCR). Methods: Surgeons performing more than 12 rotator cuff repairs (RCRs) per year were defined as high-volume surgeons, and those performing fewer than 12 RCRs were considered low-volume surgeons. Of the 47 patients who underwent revisional ARCR at our clinic enrolled in this study, 21 cases were treated by high-volume surgeons and 26 cases by low-volume surgeons. In all cases, the interval between primary surgery and revisional ARCR, degree of "acromial scuffing," number of anchors, RCR technique, retear pattern, fatty infiltration, retear size, operating time, and clinical outcome were recorded. Results: During primary surgery, significantly more lateral anchors (p=0.004) were used, and the rate of use of the double-row repair technique was significantly higher (p<0.001) in the high- versus low-volume surgeon group. Moreover, the "cut-through pattern" was observed significantly more frequently among the cases treated by high- versus low-volume surgeons (p=0.008). The clinical outcomes after revisional ARCR were not different between the two groups. Conclusions: Double-row repair during primary surgery and the cut-through pattern during revisional ARCR were more frequent in the high- versus low-volume surgeon groups. However, no differences in retear site or size, fatty infiltration grade, or outcomes were observed between the groups.

Developing a Method for Detecting the Asian dust event Among High $PM_{10}$ events Using Aerodynamic Particle Sizer (APS) (Aerodynamic Particle Sizer (APS)를 이용한 고농도 $PM_{10}$ 사례 중 황사 판별기법 개발)

  • Lee, Young-Gon;Cho, Chun-Ho;Kim, Myoung-Soo
    • Atmosphere
    • /
    • v.18 no.1
    • /
    • pp.25-32
    • /
    • 2008
  • Log normalized volume size distribution (dV/dlog$D_p$) with 52 size ranges from 0.5 to $20.0{\mu}m$ was measured for the cases of high $PM_{10}$ mass concentration (> $200{\mu}gm^{-3}$) using the Aerodynamic Particle Sizer (APS) at the Korea Global Atmosphere Watch Center (KGAWC) from 6 April, 2006 to 5 April, 2007. Black Carbon (BC), gaseous pollutants of $NO_X$ and $SO_2$ and ${\AA}ngstr\ddot{o}m$ exponent were also measured to examine the properties of the volume size distribution. From distinct difference of the high volume concentration (> $100{\mu}m^3cm^{-3}$), the volume size distribution for each event day was clasified into four types: (1) Type 1 had the high volume concentration for supermicron particles from 2.3 to $6.0{\mu}m$ and maximum average volume concentration was $160.7{\mu}m^3cm^{-3}$ at $3.5{\mu}m$. (2) Type 2 represented the high volume concentration in the both size range of submicron ($0.7-1.0{\mu}m$) and supermicron particles ($2.1-4.1{\mu}m^3cm^{-3}$ and $136.2{\mu}m^3cm^{-3}$ were found at 0.8 and $3.3{\mu}m$ respectively. (3) Type 3 showed the high volume concentration in the size range of $0.5-3.5{\mu}m$ and highest volume concentration of $201.1{\mu}m^3cm^{-3}$ at the particle size bin of $0.8{\mu}m$. (4) Type 4 was characterized by the high volume concentration for the fine particles less than $1.2{\mu}m$ and very high concentration of $446.8{\mu}m^3cm^{-3}$. ${\AA}ngstr\ddot{o}m$ exponent, concentration of gaseous ($NO_X$ and $SO_2$), and particle (BC) pollutants suggested that Type 1 was a typical volume size distribution for the Asian dust and Type 3 provided transportation of air pollutants. The distribution in Type 2 found to have both characteristics of the Asian dust and air pollutants, and Type 4 was took place during the foggy atmosphere containing high density of local pollutants. Based on the properties of volume size distribution, we can identify the three major events contributing the increase of $PM_{10}$ mass concentration, and hope to provide a guideline for discriminating the Asian dust from high $PM_{10}$ events. More case studies and longeto advance this determination method.

Trading Volume and Overpricing of Lottery-type Stocks (거래량이 복권특성 종목의 기대수익률에 미치는 영향)

  • Yong-Ho Cheon
    • Asia-Pacific Journal of Business
    • /
    • v.14 no.1
    • /
    • pp.113-129
    • /
    • 2023
  • Purpose - The purpose of this study is to examine whether trading volume amplifies the extent to which lottery-type stocks are overpriced, and whether economic sentiment index explains time-variation in the magnitude of the volume amplification effect. Design/methodology/approach - We examine monthly returns on 5x5 monthly bivariate portfolios formed by lottery characteristics (measured by maximum daily return) and trading volume. In addition, we perform time-series regression tests to examine how the volume amplification effect changes in high and low economic sentiment periods, after controlling for Fama-French three factors. Findings - Our bivariate portfolio analysis shows that the overpricing of lottery-type stocks are mostly pronounced among high trading volume stocks. In contrast, for low trading volume stocks, overpricing of lottery-type stocks appears to vanish. Furthermore, the amplification effect of trading volume on overpricing of lottery-type stock is concentrated in high economic sentiment periods. Research implications or Originality - This study is the first attempt to examine whether trading volume drives lottery-type stocks' overpricing in the Korean stock market. Furthermore, our analysis unveils the time-varying nature of volume amplification effect. The results suggest that trading volume might play a important hidden role in asset pricing, opening a new line of researches in the future.

A Study on the Properties of High Volume FlyAsh Concrete (High Volume 플라이애쉬 콘크리트의 내구적 특성 연구)

  • 이진용;손해원;최수홍;정은경;조현수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.203-206
    • /
    • 1999
  • An experimental study is carried out to investigate the characteristics of concrete containing high volume fly ash. The compressive and tensile strength of fly ash concrete is slightly lower than those of ordinary concrete between 7and 28 days, however, the long-term compressive strength is significantly higher at 180 days. In durability, the high volume fly ash concretes are generally higher resistance of freeze and thaw and lowe chloride penetration, however, the depth of carbonation is increased with increasing fly ash content.

  • PDF

The Association of Hospital Volume of Percutaneous Coronary Intervention with Cardiac Mortality

  • Kim, Jae-Hyun;Kim, Jang-Mook;Park, Eun-Cheol
    • Health Policy and Management
    • /
    • v.28 no.2
    • /
    • pp.168-177
    • /
    • 2018
  • Background: This study investigates the potential volume and outcome association of coronary heart disease (CHD) patients who have undergone percutaneous coronary intervention (PCI) using a large and representative sample. Methods: We used a National Health Insurance Service-Cohort Sample Database from 2002 to 2013 released by the Korean National Health Insurance Service. A total of 8,908 subjects were analyzed. The primary analysis was based on Cox proportional hazards models to examine our hypothesis. Results: After adjusting for confounders, the hazard ratio of thirty-day and 1-year mortality in hospitals with a low volume of CHD patients with PCI was 2.8 and 2.2 times higher (p=0.00) compared to hospitals with a high volume of CHD patients with PCI, respectively. Thirty-day and 1-year mortality of CHD patients with PCI in low-volume hospitals admitted through the emergency room were 3.101 (p=0.00) and 2.8 times higher (p=0.01) than those in high-volume hospitals, respectively. Only 30-day mortality in low-volume hospitals of angina pectoris and myocardial infarction patients with PCI was 5.3 and 2.4 times those in high-volume hospitals with PCI, respectively. Conclusion: Mortality was significantly lower when PCI was performed in a high-volume hospital than in a low-volume hospital. Among patients admitted through the emergency room and diagnosed with angina pectoris, total PCI volume (low vs. high) was associated with significantly greater cardiac mortality risk of CHD patients. Thus, There is a need for better strategic approaches from both clinical and health policy standpoints for treatment of CHD patients.

Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

The Experimental Study on the Influence of Relation between Cement Paste and Aggregate Volume to Effect the High Folwing and Engineering Properties of High Flowing Concrete (고유동콘크리트의 유동특성 및 공학적 특성에 미치는 시멘트페이스트용적 및 골재용적과의 관계에 관한 실험적 연구)

  • 김규용;최희용;강희관;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1996.10a
    • /
    • pp.301-307
    • /
    • 1996
  • High flowing concrete has been made using a combination of much amount cementitious materials and addition of SP agents, so that it makes possible to high flowing properties of fresh concrete. In the fluid mechanical and rheological point of view, high flowing concrete is affected on the relation between cement paste and aggregate of volume. In this experimental study, it is measured high flowing concrete of slump-flow about 65$\pm$5cm according to 0.54~0.80 of volume ratio and to analysed the properties of high flowing concrete in fresh and hardened concrete. It is the aim of this study to consider the affection of high flowing properties accoring to cement paste to aggregate ratio of volume on the combination of concrete.

  • PDF

Effect of the Coarse Aggregate Volume by High Temperature Mechanical Properties of Ultra High Strength Concrete (굵은골재의 용적이 초고강도 콘크리트의 고온역학적특성에 미치는 영향)

  • Hwang, Eui-Chul;Kim, Gyu-Yong;Choe, Gyeong-Cheol;Yoon, Min-Ho;Lee, Bo-Kyeong;Kim, Jung-Hyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.67-68
    • /
    • 2015
  • Recently, usage of ultra-high strengh concrete(UHSC) have been increased. Concrete has been recognized as a material which is resistant to high temperatures, but chemicophysical property of concrete is changed by the high temperature. So, mechanical properties of concrete may be reduced. Therefore, this study evaluated effect of the coarse Aggregate volume by high temperature mechanical properties of UHSC. Residual mechanical properties are evaluated under fine aggregate ratio 40,60% and 500℃ temperature on UHSC of W/B 15, 20%. As result, residual mechanical properties of UHSC are high by lower coarse aggregate volume.

  • PDF