• 제목/요약/키워드: High Voltage Generator

검색결과 575건 처리시간 0.026초

IGBT 스택을 이용한 Marx Generator 구현 (Marx Generator Implementation Using IGBT Stack)

  • 김종현;민병덕;김종수;임근희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.507-510
    • /
    • 2005
  • High voltage pulse power supply using Marx generator and solid-state switches is proposed in this study. The Marx generator is composed of 12 stages and each stage is made of IGBT stack, two diode stacks, and capacitor. To charge the capacitors of each stage in parallel, inductive charging method is used and this method results in high efficiency and high repetition rates. It can generate the pulse voltage with the following parameters: Voltage: up to 120kv Rising time: sub ${\mu}S$ Pulse width: up to $10{\mu}S$, Pulse repetition rate: 1000pps The proposed pulsed power generator uses IGBT stack with a simple driver and has modular design. So this system structure gives compactness and easiness to implement total system. Some experimental results are included to verify the system performances in this paper.

  • PDF

회전자 형상에 따른 유도발전기 전압강하에 대한 연구 (A Study on the Voltage Drop of Induction Generator along the Rotor Shape)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제64권2호
    • /
    • pp.62-66
    • /
    • 2015
  • Induction generator is easy to durability and maintenance than the synchronous generator. So, recently Induction generator has been widely applied to small-scale hydroelectric power plant. When the rotor is operating faster than synchronous speed, induction machine can generate electric power. Induction generator has a large inrush currents, such as the starting current of the induction motor. Induction motor has been designed a variety of rotor shape in order to reduce starting current. Since the occurrence of high inrush current cause a voltage drop to the system, it will need to reduce possible. Because the starting current of the squirrel-cage induction motor varies in accordance with the rotor shape, it is necessary to analyze the magnitude of inrush current in order to apply to the generator. In this study, we analyzed the inrush current and the voltage drop caused in accordance with the rotor shape of 1500kw induction generator.

유도전압합성기를 이용한 고전압 펄스발생기 설계 (Induction Voltage Adder for High Power Pulse Generator)

  • 양종원;신진우;류한용;허훈;이우상;김창구;남상훈;소준호
    • 한국군사과학기술학회지
    • /
    • 제16권5호
    • /
    • pp.703-711
    • /
    • 2013
  • In this paper, we have proposed high power generator with Induction Voltage Adder of three cells. IVA which has n cells can generate n-th times high power pulse, is a more stable system than Marx generator in the view of breakdown. We applied amorphous metal magnetic cores as an energy storing material for IVA rather than ferrite cores because of their higher magnetic flux swing to make it more compact system and the loss of it was also considered in the design. For driving the IVA, we design Blumlein pulse generators which are filled with pure water for high dielectric constant and high breakdown field strength, and triggered by single Marx generator. We have presented the PSPICE simulation and its test result.

동기발전기 여자시스템용 고주파 PWM 컨버터 설계 (Design of a High Frequency PWM Converter for Synchronous Generator Excitation System)

  • 장수진;류동균;원충연;이진국;배기훈;김수석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.515-518
    • /
    • 2002
  • A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the output voltage constant under normal operating conditions at various levels. The output voltage of Synchronous Generator is regulated constantly by field voltage control in excitation system. High frequency PWM converter (Buck converter) type excitation system for synchronous generator that can sustain prefer output voltage level even at the fault condition happened. The proper operation of the proposed excitation system was verified through the simulations and the experiments.

  • PDF

고주파 공진형 방식 X-선 발생장치에 관한 연구 (A Study on High Frequency Resonant Type X-ray Generator)

  • 유동욱;하성운;백주원;김종수;김학성;원충연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.209-211
    • /
    • 1995
  • This paper is concerned with High Frequency, High Voltage Generator for X-ray using zero-voltage soft-switching PWM DC-DC high-power converter by Resonant method, which makes the most of the parastic LC parameters of high-voltage transformer link, for diagnostic X-ray power generator. The converter circuit basically utilizes phase-shift pulse width modulated series Resonant full-bridge PWM DC-DC high-power converter operating at a constant frequency;25kHz. The converter output regulation is digitally controlled using DSP (Digital Signal Processor) for obtaining a fast rising time and adjust output voltage within a wide load range.

  • PDF

OPTIMIZATION OF OPERATION PARAMETERS OF 80-KEV ELECTRON GUN

  • Kim, Jeong Dong;Lee, Yongdeok;Kang, Heung Sik
    • Nuclear Engineering and Technology
    • /
    • 제46권3호
    • /
    • pp.387-394
    • /
    • 2014
  • A Slowing Down Time Spectrometer (SDTS) system is a highly efficient technique for isotopic nuclear material content analysis. SDTS technology has been used to analyze spent nuclear fuel and the pyro-processing of spent fuel. SDTS requires an external neutron source to induce the isotopic fissile fission. A high intensity neutron source is required to ensure a high for a good fissile fission. The electron linear accelerator system was selected to generate proper source neutrons efficiently. As a first step, the electron generator of an 80-keV electron gun was manufactured. In order to produce the high beam power from electron linear accelerator, a proper beam current is required form the electron generator. In this study, the beam current was measured by evaluating the performance of the electron generator. The beam current was determined by five parameters: high voltage at the electron gun, cathode voltage, pulse width, pulse amplitude, and bias voltage at the grid. From the experimental results under optimal conditions, the high voltage was determined to be 80 kV, the pulse width was 500 ns, and the cathode voltage was from 4.2 V to 4.6 V. The beam current was measured as 1.9 A at maximum. These results satisfy the beam current required for the operation of an electron linear accelerator.

전류제어형 PWM컨버터를 이용한 동기발전기용 여자시스템에 관한연구 (A Study on Excitation System for Synchronous Generator using Current Mode Controlled PWM Converter)

  • 장수진;류동균;서민성;김준호;원충연;배기훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.151-156
    • /
    • 2002
  • The output voltage of Synchronous Generator is regulated constantly by field current control in excitation system. A synchronous generator is equipped with an automatic voltage regulator(AVR), which is responsible for keeping the constant output voltage under normal operating conditions about various levels. High frequency PWM converter (Current Mode Control Buck converter) type excitation system for synchronous generator is able to sustain output voltage level properly when the fault condition happened. This paper deals with the design and evaluation of the excitation system controller for a synchronous generator to improve the steady state and transient stability. The simulation and experimental results show that the proposed excitation system is improve the respons time by the AVR(automatic voltage regulator) of 50kW synchronous generator that is applied the current mode control excitation system.

  • PDF

진단 X-선용 40kW 고주파 고압 전원 시스템 (High Frequency High Voltage 40kW Power System for Diagnosis X-ray)

  • 김학성;박영국;오준용;성기봉
    • 전력전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.192-198
    • /
    • 2003
  • 본 논문에서는 의료 진단용 40kw(125kV, 80mA)급 X-선 전원 장치에 대하여 연구하였다. 의료 X-선용 고전압 발생 장치의 구성과 X-선 관전압과 관전류 그리고 피폭량 제어에 대하여 기존 제어 방식과 비교 설명하였고 제어기 설계시 고려할 사항에 대하여 언급하였다. 또한, 본 시스템의 핵심이라 할 수 있는 고주파 고전압 변압기의 등가회로를 통한 기생 성분에 대하여 기술하였으며 본 연구에서 제작된 의료 X-선용 HFG 시스템의 출력특성의 우수성을 X-전관 부하 변동에 따른 X-선 관전류와 관전압 파형을 통하여 입증하였다.

Design Considerations for Low Voltage Claw Pole Type Integrated Starter Generator (ISG) Systems

  • Lee, Geun-Ho;Choi, Geo-Seung;Choi, Woong-Chul
    • Journal of Power Electronics
    • /
    • 제11권4호
    • /
    • pp.527-532
    • /
    • 2011
  • Due to the need for improved fuel consumption and the trend towards increasing the electrical content in automobiles, integrated starter generator (ISG) systems are being considered by the automotive industry. In this paper, in order to change the conventional generator of a vehicle, a belt driven integrated starter generator is considered. The overall ISG system, the design considerations for the claw pole type AC electric machine and a low voltage very high current power stage implementation are discussed. Test data on the low voltage claw pole type machine is presented, and a large current voltage source DC/AC inverter suitable for low voltage integrated starter generator operation is also presented. A metal based PCB (Printed Circuit Board) power unit to attach the 4-parallel MOS-FETs is used to achieve extremely high current capability. Furthermore, issues related to the torque assistance during vehicle acceleration and the generation/regeneration characteristics are discussed. A prototype with the capability of up to 1000 A and 27 V is designed and built to validate the kilo-amp inverter.

Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성 (A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method)

  • 정종한;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF