• 제목/요약/키워드: High Viscosity Fluid

검색결과 193건 처리시간 0.026초

수평채널 내 고 점성유체의 볼텍스 유동에 관한 3차원 수치해석(1) (Three-Dimensional Numerical Study on the Vortex Flow in a Horizontal Channels with High Viscous Fluid)

  • 박일용;김정수;배대석
    • 동력기계공학회지
    • /
    • 제18권3호
    • /
    • pp.79-86
    • /
    • 2014
  • Mixed convective vortex flow in the three-dimensional rectangular channel filled with high viscous fluid(Pr=909) is investigated computationally under various operating conditions. The Reynolds number is varied from 0 to $5{\times}10^{-1}$, the Rayleigh number from $10^3$ to $5{\times}10^4$. The three-dimensional governing equations are discretized using the finite volume method. The effects of Reynolds number and Rayleigh number are presented and discussed. From a parametric study, it is found that vortex flow pattern of mixed convection in rectangular channels can be classified into three flow patterns basically, but the new vortex flow structures containing wave rolls are found, which are affected by Rayleigh number and Reynolds number. From this results, we can draw a flow regime map to delineate various vortex flow patterns in the high viscosity fluid mixed convective flow.

오리피스와 방향제어밸브를 이용한 미세유량 분사제어시스템 (Infinitesimal Fluid Injection Control System by using an Orifice and a Directional Control Valve)

  • 정은석;오인호;이일영
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.67-68
    • /
    • 2006
  • This study suggests a precision flow control system that enables fluid injection of a few grams at a time in a few ms time duration. The fluid injection system suggested here consists of a high pressure fluid pump, a 3 way 3 position directional control valve, an injector and an orifice. The orifice is located between the directional control valve and the injector. By supplying current signal to the directional control valve, the prescribed small amount of fluid can be supplied to a plant through the injector. The control robustness of the suggested system against the disturbances like the pressure change in a plant and the viscosity variation of the injected fluid is secured easily by using an orifice with very small inside diameter and setting the supply pressure with comparatively high value. The control performances of the suggested system are verified by numerical simulations and experiments. The outcomes of this research could be applied to the common rail injection control of lubrication oil for large size marine diesel engines, and other industrial plants.

  • PDF

마이크로 원형 모세관에서 계면 이동 현상의 측정 (Measurements of Flow Meniscus Movement in a Micro Capillary Tube)

  • 이석종;성재용;이명호
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.15-21
    • /
    • 2013
  • In this paper, a high-speed imaging and an image processing technique have been applied to detect the position of a meniscus as a function of time in the micro capillary flows. Two fluids with low and high viscosities, ethylene glycol and glycerin, were dropped into the entrance well of a circular capillary tube. The filling times of the meniscus in both cases of ethylene glycol and glycerin were compared with the theoretical models - Washburn model and its modified model based on Newman's dynamic contact angle equation. To evaluate the model coefficients of Newman's dynamic contact angle, time-varying contact angles under the capillary flows were measured using an image processing technique. By considering the dynamic contact angle, the estimated filling time from the modified Washburn model agrees well with the experimental data. Especially, for the lower-viscosity fluid, the consideration of dynamic contact angle is more significant than for the higher-viscosity fluid.

Numerical simulation of a single bubble suspension in polyol resin

  • Dongjin Seo;Lim, Yun-Mee;Youn, Jae-Ryoun
    • 한국섬유공학회:학술대회논문집
    • /
    • 한국섬유공학회 2003년도 The Korea-Japan Joint Symposium
    • /
    • pp.47-48
    • /
    • 2003
  • Dilute bubble suspensions are prepared by introducing carbon dioxide bubbles into polyol resin. The apparent shear viscosity is measured with a wide gap parallel plate rheometer. A numerical simulation for deformation of a single bubble suspended in a Newtonian fluid is conducted by using a finite volume method (FVM) where multigrid algorithms are incorporated. Transient and steady results of bubble deformation were obtained and were in good agreement with experimental results. At high capillary number, viscosity of the suspension increases as the volume fraction increases, while at low capillary number, the viscosity decreases as the volume fraction increases.

  • PDF

무습수 평판인쇄의 온도 의존성에 관한 연구 (A Study on the Temperature Dependence of Waterless Lithography)

  • 신춘범;강상훈;이상남
    • 한국인쇄학회지
    • /
    • 제19권1호
    • /
    • pp.42-54
    • /
    • 2001
  • The combination of a silicone surfaced plate and high viscosity ink produced a waterless printing system that worked well, but had limitation. The limitation was that this system was restricted to relatively short run lengths. In the waterless printing process, the press tended to heat up rapidly. Heat in turn, broke down the resins in the inks, causing them to become more fluid. When the ink is heated, the viscosity will drop, the ink will become too liquid and the plate will no longer be able to resist it. The ink will adhere to the non-print portions of the plate, and will print as a very fine mist or speckle pattern in the non-image area. On the other hand, when the ink gets too cold, viscosity will increase until ink transfer is impeded. This study carried otu to investigate the effect of temperature variations of the inks on the print quality in waterless lithography and to examine the adaptability of waterless lithography to conventional offset press without cooling system.

  • PDF

Rheological behavior of dilute bubble suspensions in polyol

  • Lim, Yun-Mee;Dongjin Seo;Youn, Jae-Ryoun
    • Korea-Australia Rheology Journal
    • /
    • 제16권1호
    • /
    • pp.47-54
    • /
    • 2004
  • Low Reynolds number, dilute, and surfactant-free bubble suspensions are prepared by mechanical mixing after introducing carbon dioxide bubbles into a Newtonian liquid, polyol. The apparent shear viscosity is measured with a wide-gap parallel plate rheometer by imposing a simple shear flow of capillary numbers(Ca) of the order of $10^{-2}$ ~ $10^{-1}$ and for various gas volume fractions ($\phi$). Effects of capillary numbers and gas volume fractions on the viscosity of polyol foam are investigated. At high capillary number, viscosity of the suspension increases as the gas volume fraction increases, while at low capillary number, the viscosity decreases as the gas volume fraction increases. An empirical constitutive equation that is similar to the Frankel and Acrivos equation is proposed by fitting experimental data. A numerical simulation for deformation of a single bubble suspended in a Newtonian fluid is conducted by using a newly developed two-dimensional numerical code using a finite volume method (FVM). Although the bubble is treated by a circular cylinder in the two dimensional analysis, numerical results are in good agreement with experimental results.

유동저항 감소유체를 운반유체로 한 파라핀 슬러리의 대류 열전달에 관한 연구 (Convective Heat Transfer of a Paraffin Slurry in a Drag Reducing Carrier Fluid)

  • 정동주;최은수
    • 설비공학논문집
    • /
    • 제13권12호
    • /
    • pp.1275-1281
    • /
    • 2001
  • Aqueous polymer solutions are known to have small pressure reduction. Paraffin slurries are known to have high thermal capacity. Paraffin particles are mixed into an aqueous polymer solution to make a new heat transfer fluid having high thermal capacity but low pressure reduction. The heat transfer characteristics of the new slurry was tested in a circular tube having a constant heat transfer boundary condition. The new slurry was found to have high Nusselt numbers as well as high thermal capacity and low pressure reduction in the laminar flow. The trends of the Nusselt numbers along the heating test section were studied for various heating conditions.

  • PDF

MR유체를 이용한 유량제어 밸브 (Development of Flow Control Valve Using MR Fluid)

  • 이형돈;배형섭;이육형;박명관
    • 제어로봇시스템학회논문지
    • /
    • 제17권9호
    • /
    • pp.888-891
    • /
    • 2011
  • This paper presents development of flow control valve using MR fluid. Generally, since the apparent viscosity of MR fluids is adjusted by applying magnetic fields, the MR valves can control high level fluid power without any mechanical moving parts. In this paper, flow control valve using MR fluid on the behavior of the magnetic field influence on the numerical analysis of more accurate electromagnetic parameters were obtained, even if when magnetic field apply inside of surrounding MR fluid from electromagnet, more realistic designing way analysis of characteristic of whole magnetic field distribution is suggested by surrounding magnetic material. Also, comparison of flow rate inlet and outlet, behavior of MR fluid in experiments proposed. A new type of flow control valve using MR fluid is proposed by analysis of behavior of MR fluid in experiments.

자기 유변 유체를 이용한 각도 제한 회전 감쇠기 설계 및 응용 (Constrained rotary MR damper design and its application)

  • 김상화;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.191-194
    • /
    • 1997
  • Passive, semi-active and active dampers have been used to dissipate energy in mechanical systems. Semi-active dampers have higher performance than passive dampers and require lower power to operate than active dampers. Its damping characteristics can be changed appropriately for varying conditions. In this paper, we developed a semi-active damper based on Magnetorheological(MR) fluid. MR fluid has a variable damping characteristics proportional for the magnetic field intensity. It has several advantages such as high strength, low viscosity, robustness in impurities and wide temperature range of operational stability. We designed a constrained rotary MR damper base on valve mode which can dissipate more energy per unit volume. The system with Bingham characteristics is obtained and proved by the experiment.

  • PDF

MR 밸브의 전자기적 설계와 성능 평가 (Electromagnetic Design and Performance Evaluation of an MR valve)

  • 김기한;남윤주;박명관
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.968-973
    • /
    • 2007
  • This paper presents an electromagnetic design for the magneto-rheological fluid valve. The MR valve can control high-level fluid power without moving parts, due to the apparent viscosity controllability of the MR fluid in magnetic fields. In order to improve the static characteristic of the MR valve, the length of the flux path is decreased by removing the unnecessary bulk of the yoke. Then, in order to improve the dynamic and hysteretic characteristics, the magnetic reluctance of the ferromagnetic material is increased by minimizing the cross sectional area through which the flux passes. Two MR valves, one is a conventional type valve and the other is the proposed one, were fabricated and performance evaluation is experimentally achieved through the comparison study using by-pass damper system.

  • PDF