• Title/Summary/Keyword: High Temperature Structural Test

Search Result 251, Processing Time 0.028 seconds

Failure Analysis and Accelerated Life Test of MoxW1-xSi2 Haters Fabricated by SHS process (SHS 공정으로 제조된 MoxW1-xSi2 발열체의 가속수명시험과 고장분석)

  • Lee, Dong-Won;Lee, Sang-Hun;Kim, Yong-Nam;Lee, Heesoo;Lee, Sung-Chul;Koo, Sang-Mo;Oh, Jong-Min
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.252-255
    • /
    • 2017
  • $Mo_xW_{1-x}Si_2$ heaters were fabricated by self-propagating high-temperature synthesis (SHS) process and post sintering process. To validate the reliability of the $Mo_xW_{1-x}Si_2$ heaters, the accelerated life test (ALT) was conducted, and then lifetime to $Mo_xW_{1-x}Si_2$ heaters was estimated by using Minitab programs. Also, the failure analysis of $Mo_xW_{1-x}Si_2$ heaters after ALT was performed through electrical and structural properties. As the results, it was confirmed that the dominant failure mode of $Mo_xW_{1-x}Si_2$ heaters is the crack formation in heaters and the delamination of protective $SiO_2$ layers.

The Development of KOGAS Membrane for LNG Storage Tank (LNG 저장탱크용 KOGAS 멤브레인 개발)

  • Oh, Byoung-Taek;Kim, Young-Kyun;Yoon, Ihn-Soo;Seo, Heung-Seok;Hong, Seong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1203-1208
    • /
    • 2002
  • LNG demand has been rapidly increasing in Korea for a variety of reasons including stable supply, non-polluting, and high combustion efficiency characteristics. As a result the construction and expansion of LNG storage facilities have been continuing at a vigorous pace. Korea Gas Corp. (KOGAS) has developed the design technology of the LNG storage tank. One of the most important structural core element of the LNG storage tank is the membrane, made by stainless steel. The membrane to be applied inside of LNG storage tank is provided with corrugations to absorb thermal contraction and expansion caused by LNG temperature. Analytical results have been performed to investigate the strength of the membrane and the reaction farce at the anchor point. Experimental studies are performed to investigate the deformation and strength of the membrane which is designed by Kogas. All experiments are conducted on the basis of RPIS, and we found the results are fully satisfied with the RPIS.

The Study of Kogas Membrane Performance Test for LNG Storage Tank (Kogas 멤브레인 성능평가에 관한 연구)

  • Kim Y.K.;Hong S.H.;Yoon I.S.;Oh B.T.;Seo H.S.
    • 한국가스학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.16-22
    • /
    • 2001
  • LNG demand has been rapidly increasing in Korea for a variety of reaso including stable supply, non- polluting, and high combustion efficiency characteris As a result the construction and expansion of LNG storage facilities have b continuing at a vigorous pace. One of the most important structural core elemen the LNG storage tank is the membrane, consisting of stainless steel. The memb to be applied inside of LNG storage tank is provided with corrugations to abs thermal contraction and expansion caused by LNG temperature. From the viewp of strength design, however. it is essential to confirm that the membrane undergo a stable deformation and has a sufficient fatigue strength Experim studies are presented to investigate the deformation and strength of the memb which is designed by Kogas. All experiments are conducted on the basis of RP and we found the results is fully satisfied with the RPIS.

  • PDF

Evaluation Techniques for Residual Structural Performance of a Reinforced Concrete slab under Fire Damage (화재 피해를 입은 철근콘크리트 슬래브의 잔존 구조성능 평가기법)

  • Choi, Kwang-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.588-594
    • /
    • 2020
  • This study proposes non-destructive rebound-hardness and ultrasonic testing methods to more accurately evaluate the residual structural performance of reinforced concrete structures in a fire. Techniques are also proposed to assess the stiffness used in the deflection calculation with natural frequencies obtained by vibration tests. In the compressive strength evaluation using rebound hardness, the residual compressive strength of thick specimens and a larger water/cement (W/C) ratio were shown to be large. The homogeneity of concrete at high temperature compared to ambient temperature conditions was assessed by the velocity of ultrasonic waves that penetrate the concrete, and it followed W/C or thickness of slab makes little different results. To assess the stiffness of fire-damaged slabs and increase in deflection, the natural frequency was measured by vibration tests and incorporated into the equation of the stiffness. The application of this technique to the slab experiment showed that it can be a very reasonable evaluation technique. In addition, to evaluate the residual strength of a member after fire, a test of the strength of a component was carried out during and after heating.

A Study On The Thermal Movement Of The Reactor Coolant System For PWR (가압 경수로의 냉각재 계통 열팽창 거동에 관한 연구)

  • Yoon, Ki-Seok;Park, Taek sang;Kim, Tae-Wan;Jeon, Jang-Hwan
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.393-402
    • /
    • 1995
  • The structural analysis of the reactor coolant system mainly consist of too fields. The one is the static analysis considering the impact of pressure and temperature built up during normal operation. The other is the dynamic analysis to estimate the impact of postulated events such as the seismic loads or postulated branch line pipe breaks event. Since the most important goal of the RCS structural analysis is to prove the safety of the RCS during normal operation or postulated events, a widely proven theory having enough conservatism is adopted. The load occurring on the RCS during normal operation is considered as the basic design loading condition throughout whole plant life time. The most typical characteristic of the RCS during normal operation is the thermal expansion of the RCS caused by reactor coolant with high temperature and pressure. Therefore, the exact estimation on the thermal movement of the RCS is needed to get more clear understanding on the thermal movement behavior of the RCS. In this study, the general structural analysis concept and modeling method to evaluate the thermal movement of the RCS under the normal plant operation condition are presented. To discuss the validation of the suggested analysis, analysis results are compared with the measured data which ore referred from the standardized 1000 MWe PWR plant under construction.

  • PDF

Experimental Study for Structural Behavior of Embed Plate into Concrete Subjected to Welding Heat Input (매입강판 용접열에 의한 고강도 콘크리트 접합부 구조성능 영향평가에 관한 실험적 연구)

  • Chung, Kyung Soo;Kim, Ki Myon;Kim, Do Hwan;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.25 no.5
    • /
    • pp.569-578
    • /
    • 2013
  • In a super-tall building construction, thick and large-sized embed plates are usually used to connect mega structural steel members to RC core wall or columns by welding a gusset plate on the face of the embed plate with T-shape. A large amount of heat input accumulated by weld passes causes the plates to expand or deform. In addition, the temperature of concrete around the plates also could be increased. Consequently, cracks and spalls occur on the concrete surface. In this study, the effect of weld heat on embed plates and 80MPa high strength concrete is investigated by considering weld position (2G and 3G position), edge distance, concrete curing time, etc. Measured temperature of the embed plates was compared with the transient thermal analysis results. Finally, push-out tests were performed to verify and compare the shear studs capacity of the embed plate with design requirement. Test result shows that the shear capacity of the plate is reduced by 14%-19% due to the weld heat effect and increased as the concrete curing time is longer.

Investigation of Properties of Structural Foam with Different Conformation and via Thermal Aging Condition (구조용 폼의 조성 및 열 노화에 따른 변형특성 관찰)

  • Choe, Jin-Yeong;Kwon, Il-Jun;Park, Sung-Min;Kwon, Dong-Jun
    • Composites Research
    • /
    • v.31 no.4
    • /
    • pp.122-127
    • /
    • 2018
  • Sandwich composites of carbon fiber reinforced plastic(CFRP) and polymer foam will be used to automobile and aerospace industry according to increasing importance of light weight. In this study, mechanical and heat resistance properties of sandwich composites were compared with type of polymer foam (polyethylene terephthalate(PET), polyvinylchloride(PVC), epoxy and polyurethane). All types of polymer foams were degraded to 30, 60, 120, 180 minutes in $180^{\circ}C$. After heat degradation, the polymer foams were observed using optical microscope and compressive test was performed using universal testing machine(UTM). Epoxy foam had the highest compressive property to 2.6 MPa and after thermal degradation, the mechanical property and structure of foam were less changed than others. Epoxy foam had better mechanical properties than other polymer foams under high temperature. Because the epoxy foam was post cured under high temperature. As the results, Epoxy foam was optimal materials to apply to structures that thermal energy was loaded constantly.

Development of Assessment Methodology on Creep-Fatigue Crack Behavior for a Grade 91 Steel Structure (Mod.9Cr-1Mo 강 구조의 크리프-피로 균열 거동 평가법 개발)

  • Lee, Hyeong-Yeon;Lee, Jae-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.1
    • /
    • pp.103-110
    • /
    • 2010
  • In this study, an assessment method on creep-fatigue crack initiation and crack growth for a Mod.9Cr-1Mo steel (ASME Grade 91) structure has been developed with an extension of the French RCC-MR A16 procedure. The current A16 guide provides defect assessment procedure for a creep-fatigue crack initiation and crack growth for an austenitic stainless steel, but no guideline is available yet for a Mod.9Cr-1Mo steel which is now widely being adopted for structural materials of future nuclear reactor system as well as ultra super critical (USC) thermal plant. In the present study an assessment method on creep-fatigue crack initiation and crack growth is provided for the FMS (Ferritic-Martensitic Steel) and assessment on the creep-fatigue crack behavior for a structure has been carried out. The assessment results were compared with the observed images from a structural test.

A Study on Hot Straining Embrittlement of Coarse Grained HAZ in Steel Weldments (강 용접열영향부 조립역의 열변형취화에 관한 연구)

  • 정세희;김태영;임재규
    • Journal of Welding and Joining
    • /
    • v.3 no.1
    • /
    • pp.22-31
    • /
    • 1985
  • Hot straining embrittlement is one of the most important factors which cause the brittle fracture initiation even in the service temperature in the case of mild steel and high tensile steel. Therefore it is necessary to analyze thoroughly the hot straining embrittlement occurred in weld HAZ of the structural steels. The behaviors of plastic deformation and fracture toughness at the notch tip of the hot strained weld HAZ in structural steels (SB 41 KS, SA 588-Grade A ASTM) have been studied by the recrystallization technique and crack opening displacement (COD) test method. The obtained results are summarized as follows; 1. The plastic zone is formed at the notch tip of weld HAZ owing to nomotonic and cyclic hot stran, and the maximum plastic strain increases with the accumulated hot straining amounts. 2. The distribution of the effective strain at the plastic deformed zone in HAZ can be determined as follows; (.epsilon. over bar $_{p}$ )$_{\chi}$=.epsilon. over bar $_{cr}$ ( $R_{/chi}$/.chi.)$^{m}$ where, .epsilon. over bar $_{cr}$ : (SB 41; .epsilon. over bar $_{cr}$ = 0.2, SA 588; .epsilon. over bar $_{cr}$ = 0.1) 3. The embrittlement of weld HAZ in SB 41 and SA 588 is influenced by hot strain, and the degree of embrittlement becomes deeper with hot straining amounts. 4. The embrittlement of weld HAZ of SB 41 is not influenced by the hot straining amounts until .epsilon. over bar $_{max}$ = 0.36, $R_{\chi}$ = 0.065mm, however the embrittlement of structure in SA 588 is considerably influenced even by a small quantity of the hot straining amounts.s.

  • PDF

Heat of Hydration and Thermal Crack Control for Floating Concrete Mass Foundation (부상식 매스콘크리트 기초의 수화열 관리 및 온도균열 제어)

  • Rhee, In-Kyu;Kim, Kwang-Don;Kim, Tae-Ook;Lee, Jun-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.1
    • /
    • pp.156-164
    • /
    • 2010
  • A total of 6 stepwise constructions were made for building the floating mass concrete foundation. The optimal curing strategies and specialized construction guidelines were adoptively extracted from the 1.5m cube mock-up test prior to the main concrete work. Two different thermal crack index(TCI) calculations from current construction manual exhibit relatively low values as comparing the measured temperature data. This implies that the hydration-induced cracking could be developed in parts of concrete mass. However, the controversial phenomenons in reality were observed. No significant surface cracks are detected at the successive construction stages. Thereby, this paper raises the question regarding on the existence of characteristic length with varying size and shape of a target specimen which are missing in the current construction manual. The isothermal core area and high thermal gradient area in the edge volume should be identified and be introduced to TCI calculation for the purpose of an accuracy.