• 제목/요약/키워드: High Temperature Strength Structure Test

검색결과 125건 처리시간 0.024초

Behaviors of UHPC-filled Q960 high strength steel tubes under low-temperature compression

  • Yan, Jia-Bao;Hu, Shunnian;Luo, Yan-Li;Lin, Xuchuan;Luo, Yun-Biao;Zhang, Lingxin
    • Steel and Composite Structures
    • /
    • 제43권2호
    • /
    • pp.201-219
    • /
    • 2022
  • This paper firstly proposed high performance composite columns for cold-region infrastructures using ultra-high performance concrete (UHPC) and ultra-high strength steel (UHSS) Q960E. Then, 24 square UHPC-filled UHSS tubes (UHSTCs) at low temperatures of -80, -60, -30, and 30℃ were performed under axial loads. The key influencing parameters on axial compression performance of UHSS were studied, i.e., temperature level and UHSS-tube wall thickness (t). In addition, mechanical properties of Q960E at low temperatures were also studied. Test results revealed low temperatures improved the yield/ultimate strength of Q960E. Axial compression tests on UHSTCs revealed that the dropping environmental temperature increased the compression strength and stiffness, but compromised the ductility of UHSTCs; increasing t significantly increased the strength, stiffness, and ductility of UHSTCs. This study developed numerical and theoretical models to reproduce axial compression performances of UHSTCs at low temperatures. Validations against 24 tests proved that both two methods provided reasonable simulations on axial compression performance of UHSTCs. Finally, simplified theoretical models (STMs) and modified prediction equations in AISC 360, ACI 318, and Eurocode 4 were developed to estimate the axial load capacity of UHSTCs at low temperatures.

유동화 공법을 적용하여 제조한 고유동 콘크리트의 시공 (Execution of High Fluidity Concrete by Flowing Method)

  • 한민철;손성운;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2001년도 학술논문발표회
    • /
    • pp.28-33
    • /
    • 2001
  • This paper presents the results of mock up test on the manufacturing of high fluidity concrete by applying flowing methods with segregation reducing type superplasticizer(SRS). Three kinds of mock up structure are made such as. conventional concrete(A), high fluidity concrete(B) and high fluidity concrete incorporating 20% of fly ash(C). Physical and mechanical properties, temperature history of structure and nondestructive test are performed. Segregation reducing type superplasticizer is put into base concrete at field, and base concrete is also flowed at field. C mock up structure which requires 0.85% of SRS to flow base concrete shows most desirable performance at fresh state. The highest rising temperature shows the lowest at C structure among the tested structures. Strength variations before and after flowing also show the lowest values at C structures.

  • PDF

고조파 평가를 통한 콘크리트의 고온 열화 평가 (Evaluation of Deterioration of Concrete due to High Temperature through Harmonics)

  • 황의철;김규용;손민재;편수정;;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.146-147
    • /
    • 2021
  • In this study, the deterioration of concrete subjected to high temperature was evaluated using harmonics. When concrete is exposed to high temperatures, its mechanical properties deteriorate. In order to evaluate this deterioration, a method of analyzing the waveform of elastic waves was applied. As the heating temperature increased, the fundamental wave of the 50 kHz elastic wave passing through the concrete decreased. In addition, harmonics were generated at each temperature, and the higher the heating temperature, the greater the ratio of harmonics. The higher the compressive strength, the greater the amplitude of the fundamental wave, and this phenomenon is thought to be due to the internal structure of concrete.

  • PDF

일정축력하에 고온을 받는 고강도 콘크리트 충전강관 기둥의 구조적 거동에 관한 연구 (Experimental Evaluation of Fire Behavior of High-Strength CFT Column with Constant Axial Load)

  • 정경수;최인락;김도환;김진호
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.71-80
    • /
    • 2013
  • 구조, 시공 및 내화측면에서 우수한 콘크리트충전강관(CFT)부재에 대해서 구성재료의 강도가 높은 경우 즉, 콘크리트 압축강도가 100MPa 이상이면서 강관의 항복강도가 650MPa 이상인 경우에 대한 내화성능 평가실험 및 해석적 연구는 미비한 실정이다. 본 연구에서는 이러한 부재에 대해서 내화성능 거동을 파악하고자 ${\Box}-400{\times}400{\times}15$, 부재길이 3,000mm인 실물대 중심재하 내화실험을 행하였다. 실험변수는 중심축력을 5,000kN과 2,500kN로 하였다. 실험결과, 고강도 콘크리트의 폭렬 및 콘크리트 내부 균열에 의하여 축하중이 클수록 조기에 내력을 상실하였다. 또한, 유한차분법과 변형률적합조건을 이용한 비정상온도해석 및 응력해석을 수행하였으며, 고강도 재료모델은 Eurocode모델을 이용하였다. 해석모델은 시간-축변위 관계를 합리적으로 예측할 수 있었다.

High-Temperature Fracture Strength of a CVD-SiC Coating Layer for TRISO Nuclear Fuel Particles by a Micro-Tensile Test

  • Lee, Hyun Min;Park, Kwi-Il;Park, Ji-Yeon;Kim, Weon-Ju;Kim, Do Kyung
    • 한국세라믹학회지
    • /
    • 제52권6호
    • /
    • pp.441-448
    • /
    • 2015
  • Silicon carbide (SiC) coatings for tri-isotropic (TRISO) nuclear fuel particles were fabricated using a chemical vapor deposition (CVD) process onto graphite. A micro-tensile-testing system was developed for the mechanical characterization of SiC coatings at high temperatures. The fracture strength of the SiC coatings was characterized by the developed micro-tensile test in the range of $25^{\circ}C$ to $1000^{\circ}C$. Two types of CVD-SiC films were prepared for the micro-tensile test. SiC-A exhibited a large grain size (0.4 ~ 0.6 m) and the [111] preferred orientation, while SiC-B had a small grain size (0.2 ~ 0.3 mm) and the [220] preferred orientation. Free silicon (Si) was co-deposited onto SiC-B, and stacking faults also existed in the SiC-B structure. The fracture strengths of the CVD-SiC coatings, as measured by the high-temperature micro-tensile test, decreased with the testing temperature. The high-temperature fracture strengths of CVD-SiC coatings were related to the microstructure and defects of the CVD-SiC coatings.

Ni 기 초합금 급냉응고 리본의 미세구조와 고온 인장특성에 관한 연구 (A Study on the Microstructures and High Temperature Tensile Properties of Ni-base Superalloy Melt-Spun Ribbons)

  • 한창석
    • 열처리공학회지
    • /
    • 제27권4호
    • /
    • pp.180-184
    • /
    • 2014
  • In order to make clear relationship between high temperature tensile properties and fine microstructure of rapidly solidified cast-type Ni-base superalloys without heat treatment required for consolidation process, tensile test was carried out by changing strain rate from $5{\times}10^{-5}s^{-1}$ to $2{\times}10^{-2}s^{-1}$ and test temperature from $900^{\circ}C$ to $1050^{\circ}C$ using IN738LC and Rene'80 melt-spinning ribbons by twin roll process which were superior to ribbons by single roll process from the viewpoint of structure homogeneity. The dependence of tensile strength on strain rate and test temperature was studied and strain rate sensitivity, m, were estimated from tensile test results. From this study, it was found that tensile strength was influenced by ${\gamma}^{\prime}$ particle diameter, test temperature and strain rate, and m of ribbons exhibited above 0.3 over $950^{\circ}C$.

GFRP 표면매립공법으로 보강된 RC보의 고온노출 후 휨 성능 (Flexural Performance of RC Beams Strengthened with NSM-GFRP Exposed to High Temperature)

  • 김희승;이혜학;최경규
    • 대한건축학회논문집:구조계
    • /
    • 제34권4호
    • /
    • pp.35-42
    • /
    • 2018
  • This study evaluated the fire resisting capacity and post-fire serviceability of the concrete beams retrofitted by near surface mounted method(NSM) using GFRP plates. Main parameters in the test are grout materials and fire exposure. For the test, two types of grout materials between concrete substrate and GFRP plate were used; flame resisting epoxy and filling mortar. Four RC beam specimens were made and two of them were exposed to fire according to real scale fire curve proposed KS F 2257. After the fire exposure test, flexural test were performed to investigate the flexural performance of concrete beams including strength and deformation. From the test results, it was found that the beam retrofitted by NSM-GFRP presented higher flexural strength than that of the beam without retrofit, which indicates NSM-GFRP retrofit technologies is effective to maintain flexural strength even after fire exposure. In addition, the specimens grouted by epoxy showed good performance in strength but bad performance in ductility.

EVA Powder 개질 고강도 콘크리트의 초기강도 및 수밀특성 (Early Strength and Properties of EVA Powder Modified High Strength Concrete)

  • 김영익;성찬용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.123-127
    • /
    • 2005
  • EVA Powder modified high strength concretes were prepared by varying polymer/binder mass ratio with a constant water/binder mass ratio of 0.3. The effect of EVA powder on the slump, hydration heat, compressive and flexural strength, toughness and water absorption ratio was studied. In hydration heat test, temperature of hydration reaction displayed almost fixed level regardless of containing rate of EVA powder, but peak time of hydration reaction displayed late inclination as containing rate of powder increases. With the same water/binder mass ratio, the compressive strength and water absorption of EVA powder modified concretes decreased slightly when EVA powder was added and the flexural strength of EVA powder modified concretes rised slightly when EVA powder was added. Also, the toughness of the modified concretes can be improved markedly. The interpenetrating structure between the polymeric phase and cement hydrates formed at a $2{\sim}6%$(containing rate of EVA powder). The properties of the polymer modified concretes were influenced by the polymer film, cement hydrates and the combined structure between the organic and inorganic phases.

  • PDF

산화된 탄화규소재료의 기계적 특성에 대한 연구 (A Study on Mechanical Properties of Oxygenated SiC Material)

  • 이상필;곽재환;이진경
    • 한국산업융합학회 논문집
    • /
    • 제27권2_2호
    • /
    • pp.397-402
    • /
    • 2024
  • Silicon carbide materials undergo an oxidation reaction in a high-temperature oxidizing environment and show different characteristics depending on the test temperature and time. In particular, the added oxides form a secondary phase within the sintering process and exhibit different oxidation characteristics depending on the added sintering materials. Therefore, to evaluate the oxidation characteristics, the weight of the test piece and the thickness of the oxidation layer were observed, and the structure and oxidation characteristics of the material were analyzed using SEM. SEM observation showed that an oxide layer was formed on the surface of the liquid sintered silicon carbide material after it was oxidized at 1200 ℃, 1300 ℃, and 1400 ℃ for 10 hours, respectively. Then, a bending test was performed at each temperature on the test piece with the oxidation layer formed to evaluate the change in flexural strength. The strength was 466.6 MPa at 1200 ℃, 363.1 MPa at 1300 ℃, and 350.8 MPa at 1400 ℃. Al2O3-SiO2 oxidized at 1200 ℃ for 10 hours showed an increase in strength of about 21.0 MPa compared to the data before the oxidation test.

초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구 (A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete)

  • 백영운;육태원;박동수;김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF