• 제목/요약/키워드: High Temperature Filter System

검색결과 141건 처리시간 0.031초

Filler metal을 이용한 Stainless steel필터의 제조 및 통기도 (Fabrication and Permeability of Stainless Steel Filter by using Filler Metal)

  • 배승열;안인섭;성택경;최주호
    • 한국분말재료학회지
    • /
    • 제11권4호
    • /
    • pp.288-293
    • /
    • 2004
  • The application concept of using a fail safety filter on the filtering system is to prevent the particle leakage when the main filter element is broken at high temperature. In this study, the metal filters were fabricated by pressureless sintering method. The mixture of stainless steel powders and filler metal binder solved in the water solutions of 5% PVA was compacted to form the cylindrical filter without pressure. The compacted filter were sintered in the vacuum sintering furnace at 120$0^{\circ}C$ for 1 hour. The metal filter(produced with powder of 640-840 ${\mu}m$ size) having more than above 50% porosity, 500${\mu}m$ pore size, and permeability of 7.3${\times}$10$^{-11}$m$^{2}$ plugged within 2.5 minute to prevent the leakage of maximum slip particle size of less than 3${\mu}m$.

대형디젤엔진 배출가스 저감을 위한 DPF의 재생특성 연구 (A Study on Characteristics of DPF for Heavy-duty Diesel Engine on Pollutant Emission Reduction)

  • 엄동섭;이승호;오상기
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.34-39
    • /
    • 2008
  • The combustion purpose of diesel engine is to reduce the emission of green gas and to produce high output. Generally, the regulation matter of emission gas is largely diveded by 'THC', 'NOx', 'CO' and 'PM'. Among those matters, the most problem is to disgorge into 'PM', the character of diesel combustion. Diesel PM can be controlled using Diesel Particulate Filter, which can effectively reduce the level of soot emissions to ambient background levels. $NO_2$ generated by the DOC is used to combust the carbon collected in the DPF at low temperature. To certificate DPF device that is suitable to domestic circumstances, it is necessary to exactly evaluate the DPF devices according to the regulation of DPF certificate test procedure fur retrofit. To do carry out the above-mentioned description the understanding of that regulation like the standard of PM reduction is needed. In this study the test procedure including test cycle and BPT test condition was examined, and also the test result for specific DPF was analyzed. In every test like field test, PM reduction efficiency test and Seoul-10 mode test, no defect was showed.

  • PDF

한방용 용적맥파 시스템 (Volume Pulse Wave Detection System for Oriental Medicine)

  • 김형태;한순천;최태종;김정국;허웅;박영배
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.77-80
    • /
    • 2001
  • In this paper, we devised volume pulse detection system which can quantitatively represent a artery elasticity for oriental clinic. Volume pulse wave detecter system consist of transducer which has IRLED-photodiode detecter, temperature sensor and filter and preprocessing circuits, data conversion and serial communication parts, and computer system. The high-pass filter are detect volume pulse wave and lowpass filter detect tissue thickness. The detected volume pulse wave are normalized by tissue thickness value with a division process. As the result of experiment, we can detect normalized volume pulse wave with effectively.

  • PDF

인듐안티모나이드(InSb) 소자를 이용한 적외선 방사온도 계측시스템의 개발연구 (Development of Radiation Thermometer using InSb Photo-detector)

  • 황병옥;이원식;장경영
    • 한국정밀공학회지
    • /
    • 제12권7호
    • /
    • pp.46-52
    • /
    • 1995
  • This paper proposes methodologies for the development of radiation thermometer using InSb photo-detector of which spectral sensitivity is excellent over the wave length range of 2 .mu. m .approx. 5 .mu. m. The proposed radiation thermometer has broad measurement range from normal to high, up to more than 1000 .deg. C, with high accuracy, and can measure temperature on the material surface or heat emission noncontactely with high speed. Optical system was consisted of two convex lens with foruslength of 15.2mm for infrared lay focusing, Ge filter to cut the short wave length components and sapphire filter to cut the long wave length components. The cold shielded was installed in the whole surface of the light-absorbing element to remove the error- mometer, calibration using black body furnace which has temperature range of 90 .deg. C .approx. 1100 .deg. C was carried out, and temperature calaibration curve was obtained by exponential function curvefitting. The result shows maximum error less than 0.24%(640K .+-. 1.6K) over the measurement range of 90 .deg. C .approx. 700 .deg. C, and from this result the usefulness of the developed thermometer has been confirmed.

  • PDF

NO 환원반응을 위한 $V_2O_5/TiO_2$계 촉매필터의 $MnO_2$ 조촉매 효과 (The Effect of $MnO_2$ Addition on the $V_2O_5/TiO_2$ Catalytic Filters for NO Reduction)

  • 신해중;최재호;송영환;이주영;장성철;최주홍
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.363-368
    • /
    • 2008
  • Nitrogen oxides (NO, $NO_2$ and $N_2O$) have been controlled effectively by the SCR catalysts coated on monolith or honeycomb in commercial sites with ammonia as reductant at high temperature range $300{\sim}400^{\circ}C$. However, the catalytic filter has much merit on the point of controlling the particles and nitrogen oxides simultaneously. It will be more advanced-system if the catalytic working temperature is reduced to the normal filtration temperature of under $200^{\circ}C$. This study has focus on the development of the catalytic filter working at the low temperature. So the additive effect of the components such as Pt and Mn (which are known the catalytic component of $V_2O_5/TiO_2$ was investigated. The $V_2O_5-WO_3$ catalytic filter exhibited high activity and selectivity at $250{\sim}320^{\circ}C$ showing more than 95% NO conversion for the treatment of 600 ppm NO at face velocity 2 cm/s. The Pt-$V_2O_5-WO_3$ catalytic filter shifted the optimum working temperature towards the lower temperature ($170{\sim}200^{\circ}C$). And NO conversion was 100% and higher than that of $V_2O_5-WO_3$ catalyst at $250{\sim}320^{\circ}C$. The $MnO_X-V_2O_5-WO_3$ catalytic filter showed the wide temperature range of $220{\sim}330^{\circ}C$ for more than 95% NO conversion. This is a remarkable advantage when considered the $MnO_X$ catalytic filter presents the maximum activity at $150{\sim}250^{\circ}C$ and $V_2O_5-WO_3$ catalytic filter shows the maximum activity at $250{\sim}320^{\circ}C$.

  • PDF

The treatment of coolant wastewater of rolling plate process by High Gradient Magnetic Separation

  • Kim, Tae-Hyung;Ha, Dong-Woo;Kwon, Jun-Mo;Sohn, Myung-Hwan;Baik, Seung-Kyu;Oh, Sang-Soo;Ko, Rock-Kil;Kim, Ho-Sup;Kim, Young-Hun;Park, Seong-Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권4호
    • /
    • pp.8-11
    • /
    • 2009
  • This study introduced wastewater treatment method by High Gradient Magnetic Separation (HGMS). HGMS treatment was high efficient method for various industrial wastewaters. The system is currently research state, but we have surveyed commercialize the technology for industry. In rolling plate process, coolant wastewater was recycled by sedimentation and sand filter system. It needs several large reservoirs and long time to remove suspended solid (SS) like metal fines and iron oxide in hot rolling plate making process. If removing rate of suspended solid in rolling coolant wastewater is improved by using HGMS system, the productivity of working process can be increased and the area of reservoir can be reduced. We manufactured high temperature superconducting HGMS system that had a purpose to treatment of coolant wastewater in rolling plate process. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel 430 mesh, which is a core component in the magnetic separation system, In our basic preliminary experiment using HGMS system, it has been clear that the fine paramagnetic particles in the coolant wastewater obtained from rolling plate process of POSCO can be separated with high efficiency.

회전 라만 신호를 이용한 낮 시간 온도측정 라이다 (Daytime Temperature Measuring LIDAR System by Using Rotational Raman Signal)

  • 윤문상;김덕현;박선호;신명재;김용기;정해두
    • 한국광학회지
    • /
    • 제23권4호
    • /
    • pp.159-166
    • /
    • 2012
  • 본 연구에서는 질소와 산소의 회전 라만 신호를 측정하여 낮 시간 온도 측정이 가능한 라이다 시스템을 자체 개발하였다. 태양광에 의한 배경신호를 줄이기 위하여 파장의 폭이 좁고(0.5 nm) 제거율이 높은($10^{-6}$) 회절판과 간섭필터를 이용하였다. 개발된 장치의 성능을 검증하기 위하여 라이다를 수평방향으로 조사하여 온도 특성을 얻고 기상청에서 주어지는 값과 비교하여 상관관계가 일치함을 알 수 있었다. 그리고 수직온도분포로 얻기 위하여 수평으로 얻은 검정 값을 사용하였다. 또한 수직방향으로 조사하여 미국 표준 데이터와 비교하였으며, 존데 데이터와 검정을 통한 본 연구의 결과를 비교하였다.

용융 Si 침윤방법에 의한 반응소결 탄화규소 고온가스 필터의 제조 및 특성 (Fabrication and Properties of Reaction Bonded SiC Hot Gas Filter Using Si Melt Infiltration Method)

  • 황성식;김태우
    • 한국세라믹학회지
    • /
    • 제40권9호
    • /
    • pp.891-896
    • /
    • 2003
  • IGCC 발전 시스템에 사용되는 고온 가스 필터에 대하여 용융 Si 침윤공정 방법을 사용한 고강도 반응소결 탄화규소 고온 가스 필터 제조 공정이 개발되었다. 용융 Si 침윤 반응으로 제조된 반응소결 탄화규소의 상온 및 고온 파괴강도는 약 50-123, 60-66 MPa이었으며, 반응소결 탄화규소 다공체의 평균기공크기 및 기공율의 범위는 각각 60- 70 $\mu\textrm{m}$ 및 약 34 vol%이었다. 용융 Si 침윤 방법으로 제조된 반응 소결 탄화 규소 다공체에서는 SiC 입자 사이에 SiC/Si으로 이루어진 기지 상이 형성되어 고온 파괴 강도가 점토 결합 탄화 규소 다공체보다 우수하였다. 소결된 지지층 위에 Si 분말이 첨가되지 않은 slurry를 사용하여 여과층을 제조하였다. 여과층에 사용된 Sic 입자의 크기가 10$\mu\textrm{m}$에서 34 $\mu\textrm{m}$로 증가됨에 따라 SiC 입자 사이에 형성된 기지상의 두께가 증가하였다. 분진이 포함된 유체의 face velocity 변화에 따른 압손의 관계는 US filter사 Schumacher type 20 filter의 기체 유동 특성과 비슷하게 나타났으며, 분진여과 측정시 4분 내에 누출 분진의 크기가 1 $\mu\textrm{m}$ 크기 이하로 감소되었다.

디젤엔진 배기가스의 PM저감용 세라믹필터 집진장치 여과특성에 관한 연구 (Analysis of Filtration Characters Ceramic filter Collectors for PM removal of Diesel Engine exhaust gas)

  • 이광식;김기호;오정원;이영필
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.151-152
    • /
    • 2012
  • Collectors connected to diesel engine exhaust pipe for application of PM reduction facilities which was used to reduce PM from the exhaust gas produced from ship, Filtration performance of PM was tested. In this system, it was confirmed that the bag house can remove over 90 percent of PM from a lot of high temperature and high pressure gases produced in diesel engine. The results obtained from performance test show the potential possibility for commercialization of ceramic filter collectors which is applied to reduction facilities of flue gas produced from a diesel engine on the ship.

  • PDF

사이클론-카트리지필터 일체형 가우징 집진기의 유동해석 (Flow Analysis of Cyclone-Cartridge Filter Gausing Collector)

  • 장성철;정대영;조정식
    • 한국산업융합학회 논문집
    • /
    • 제21권3호
    • /
    • pp.133-139
    • /
    • 2018
  • Precipitator is the most widespread device used to separate dust particles from the exhaust gas. In the shipyard, welding umbrellas, spark protection covers, and ventilators are not purchased and used for the work place to capture the flames and high temperature metal dust generated during the gardening process. In particular, a thorough analysis of design factors, such as capture rate, collection capacity calculation, filter speed, and materials selection, is required since spatial constraints are followed by structures, etc. In this study, conceived to address problems such as this cyclone and filtration filter system that combines all-in-one gausing collector prototype. Assessed through interpretation through the validity of the design and reliability.