• Title/Summary/Keyword: High Rise

Search Result 4,455, Processing Time 0.031 seconds

An equivalent model for the seismic analysis of high-rise shear wall apartments (고층 벽식 아파트의 지진해석을 위한 등가모델)

  • Kim, Tae-Wan;Park, Yong-Koo;Kim, Hyun-Jung;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.5
    • /
    • pp.11-21
    • /
    • 2007
  • Currently in the country, the necessity of seismic analyses is increasing due to the increase of demand and interest in seismic design. Especially, shear wall apartments are constructed mostly for a residental building so seismic analyses for the apartment are actively executed. For the seismic analysis of the shear wall apartment, it may be not efficient in time and effort to model the entire structure by a finite element mesh. Therefore, an equivalent model is needed to simulate the dynamic behavior of the structure by decreasing the number of degrees of freedom. In this study, a method to form an equivalent model that is simple and easy to use was proposed utilizing effective mass coefficient that is highly correlated to mode shape of the structure. This equivalent model was obtained by replacing a shear wall structure with an equivalent frame structure having beams and columns. This model can be used very effectively when excessive seismic analyses are necessary in a short period because it can be operated in any commercial program and reduce the analysis time. Also, it can model floor slabs so it can represent the actual behavior of shear wall apartments. Furthermore, it is very excellent since it can represent the asymmetry of the structure.

The study on the effect of fracture zone and its orientation on the behavior of shield TBM cable tunnel (단층파쇄대 규모 및 조우 조건에 따른 전력구 쉴드 TBM 터널의 거동 특성 분석)

  • Cho, Won-Sub;Song, Ki-Il;Kim, Kyoung-Yul
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.4
    • /
    • pp.403-415
    • /
    • 2014
  • Recently, the temperature rise in the summer due to climate change, power usage is increasing rapidly. As a result, power generation facilities have been newly completed and the need for ultra-high-voltage transmission line for power transmission of electricity to the urban area has increased. The mechanized tunnelling method using a shield TBM have an advantage that it can minimize vibrations transmitted to the ground and ground subsidence as compared with the conventional tunnelling method. Despite the popularity of shield TBM for cable tunnel construction, study on the mechanical behavior of cable tunnel driven by shield TBM is insufficient. Thus, in this study, the effect of fractured zone ahead of tunnel face on the mechanical behavior of the shield TBM cable tunnel is investigated. In addition, it is intended to compare the behavior characteristics of the fractured zone with continuous model and applying the interface elements. Tunnelling with shield TBM is simulated using 3D FEM. According to the change of the direction and magnitude of the fractured zone, Sectional forces such as axial force, shear force and bending moment are monitored and vertical displacement at the ground surface is measured. Based on the stability analysis with the results obtained from the numerical analysis, it is possible to predict fractured zone ahead of the shield TBM and ensure the stability of the tunnel structure.

Pile and adjacent ground behaviors depending on horizontal offset between pile and tunnel subjected to horizontally loaded single pile (수평하중을 받는 단일 말뚝 하부 터널굴착 시 말뚝-터널 수평이격거리에 따른 말뚝 및 인접 지반 거동)

  • Ahn, Ho-Yeon;Oh, Dong-Wook;Lee, Yong-Joo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.5
    • /
    • pp.685-703
    • /
    • 2017
  • Recently, as the number of high-rise building and earthquake occurrence are increasing, it is more important to consider horizontal load such as wind and seismic loads, earth pressure, for the pile foundation. Also, development of underground space in urban areas is more demanded to meet various problem induced by growing population. Many studies on pile subjected to horizontal load have been conducted by many researchers. However, research regarding interactive behavior on pile subjected to horizontal load with tunnel are rare, so far. In this study, therefore, study on the behaviors of ground and horizontal and vertical loads applied to single pile was carried out using laboratory model test and numerical analysis. The pile axial force and ground deformation were investigated according to offset between pile and tunnel (0.0D, 1.0D, 2.0D: D = tunnel diameter). At the same time, close range photogrammetry was used to measure displacement of underground due to tunnelling during laboratory model test. The results from numerical analysis were compared to that from laboratory model test.

Behavior of braced wall due to distance between tunnel and wall in excavation of braced wall nearby tunnel (터널에 인접한 흙막이굴착 시 터널 이격거리에 따른 거동특성)

  • Ahn, Sung Joo;Lee, Sang Duk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.4
    • /
    • pp.657-669
    • /
    • 2018
  • In recent years, the development of complex urban areas has become saturated and much attention has been focused on the development of underground space, and deep excavation is frequently performed in order to increase the utilization of underground space due to the enlargement of buildings and the high rise of buildings. Therefore, in this study, we tried to understand the behavior of the braced wall and the behavior of the tunnel adjacent to the wall according to the stiffness of the wall and the distance between the tunnel and wall. As a result of the study, the deformation of the braced wall tended to decrease with increasing the stiffness of the wall, and the axial force acting on the struts was also different according to the stiffness of braced wall. When the stiffness of the braced wall is small (2 mm), the point at which the axial force of the braces maximizes is near 0.3H of the wall. When the stiffness of the braced wall is large (5 mm), the axial force is maximum at around 0.7H of the wall. Also, the tunnel convergence occurred more clearly when the separation distance from the braced wall was closer, the stiffness of the wall was smaller, and the tunnel convergence was concentrated to the lower right part. The ground settlement due to the excavation of the ground tended to decrease as the distance between tunnel and braced wall was closer to that of the tunnel, which is considered to be influenced by the stiffness of the tunnel.

Study on Generator Control for a Small X-Ray Tube (X-선 튜브의 고전압 발생장치 제어에 관한 연구)

  • Lee, Soonhyouk;Ji, Yun-Seo;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to develope a control system for a small X-ray tube generator and investigate control methods for the X-ray generator. The small X-ray tube was developed for electronic brachytherapy, and thus, the new control method should be investigated, if the small X-ray tube is used for the imaging system. The Axxent S700 X-ray tube and the XF060NZZ485 high voltage generator were used to compose a X-ray imaging system and control board was developed by using AT90CAN128 MCU. The two control methods were investigated after tube voltage was set to 50 kV, one was filament current control method and the other was beam current control method. The former was subdivided into two methods according to the filament heating time, the 5 and the 10 seconds respectively. In the filament current method, the beam current did not rise up to the desired value, if the filament current had not been maintained for at least 10 seconds. The onset filament currents to generate beam current were varied from 1,300 to 1,350 mA and over 5 seconds were needed in order to reach the desired tube current value after beam current was generated. However, in the tube current control method, the beam current reached to the desired value without any time delay with the filament current of 1,500 mA. In this study, we found that the beam current control method was appropriate for the use of small X-ray tube developed for brachytherapy in the X-ray imaging system.

Thermal Analysis of Vegetable Insulation Oil for Hermetically Sealed Wind Turbine Transformer (풍력발전기용 밀폐형 변압기의 식물성 절연유에 대한 열적특성 연구)

  • Lee, Sung-Won;Lee, Joon-Yeob;Kim, Jun-Su;Woo, Jae-Hi;Kim, Dong-Hae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.1
    • /
    • pp.97-102
    • /
    • 2012
  • A hermetically sealed oil transformer is designed by applying expanding function of the tank due to the volume changes of the insulation oil according to the temperature rises. When the insulation oil expands, an increase in the volume of the corrugated fin prevents a pressure rise of the transformer. For a wind turbine transformer, a vegetable-oil-immersed transformer has the advantages of excellent biodegradation and fire-resistant properties like an exceptionally high fire point. When vegetable oil is substituted for mineral oil, however, the maximum winding temperature rises because of the decrease in the internal circulation flow rate resulting from the variations of the oil's physical characteristics, such as density and viscosity. The purpose of this study is to develop a hermetically sealed vegetable oil transformer that can be applied in a wind turbine and to analyze the thermal stability of the active part of the transformer to deal with pressure variations due to the temperature changes. In addition, thermal tests for the vegetable oil transformer have been performed, and the measured values are compared with the analysis results.

Quaternary Depositional Environments in the Central Yellow Sea Interpreted from Chirp Seismic Data (고해상 탄성파 자료를 이용한 황해 중부 해역에서의 제4기 퇴적환경)

  • 허식;천종화;한상준;신동혁;이희일;김성렬;최동림;이용국;정백훈;석봉출
    • Journal of the Korean Geophysical Society
    • /
    • v.2 no.3
    • /
    • pp.191-200
    • /
    • 1999
  • Analysis of chirp high-resolution seismic profiles from the central Yellow Sea reveals that depositional environments in this area can be divided into three distinctive zones from west to east: (1) subaqueous delta system near the Shandong Peninsula, (2) erosional zone in the central Yellow Sea, and (3) tidal sand ridges and sand waves near the Korean Peninsula. The Shandong subaqueous delta, extending southward from the Shandong Peninsula, changes gradually into prodelta southeastward. The sediments originated from the Yellow River are transported southward along the Chinese coastal area. The erosional zone in the central Yellow Sea contains numerous paleochannels and shows linear erosional features trending northwest-southeast. The erosional zone would be dominated by non-depositional or erosional processes during the Holocene. Tidal sand ridges and sand waves are well developed along the western coast of Korea. The residual sands, which were originally fluvial sediments at the sea-level lowstand, are interpreted as the result of winnowing process during the sea-level rise. Modern sand ridges generally migrates in a northeast-southwestern direction, which coincide with dominant tidal current direction.

  • PDF

DEVELOPMENT OF PASSENGER SAFETY BOARD FOR RAILWAY VEHICLE USE

  • Mun Hyung-Suk;Eum Ki-Young;Koo Dong-Hoe
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.287-294
    • /
    • 2003
  • There are a lot of curved subway stations in Seoul metropolitan area. These must be straightly constructed as many as possible. But some of stations are roundly designed and built in order to avoid pre-existed underground obstacle such as basement of high rise building, underground gas or water pipe line and subway stations from another line. As shown fig 1, one of the biggest problem occurring curved subway station is considered large gap between platform and vehicle when vehicle completely stop at the station. The gap potentially is in existence to subway passenger as very dangerous factors in rush hours. If passenger accidentally drop their food or leg between this gap when they get on the train and train leaves station, the passenger will be seriously injured by vehicle. In this paper, various design and instruments are introduced and best solution for this matter will be presented. In order to eliminate any possibility of accident happened gap between platform and vehicle, KRRI(Korea Railroad Research Institute) have been developed new safety instrument. These technologies were applied for patent by KRRI. These mechanisms will provide confidence as well as safety to Korean subway passenger

  • PDF

A Study for Safety Environment around School Facilities. - Focused on School Routes - (학교시설 외부 안전환경 현황 조사연구 - 학교 주변 통학로를 중심으로 -)

  • Maeng, Jun-Ho;Kim, Kwan-Yeong;Kim, Sung-Joong;Park, Young-Bin;Shin, Soyoung;Kim, Hyosun
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.19 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • Despite the legal and institutional measures that have been enacted for the safety management of school facilities, the number of school accidents has continued to rise, particularly in regards to the number of accidents related to schools. However, school facilities have had a difficult time creating safe school environments for the school administration and local governments. This is due to the fact that the Office of Education and the Ministry of Education, not the school or educational offices, have insufficient institutional devices such as standards and systems for the promotion of safe school environments. This study attempted to confirm the direction of the improvement of the safety of school facilities. To this end, four safety assessment topics (separation of pedestrians, pedestrian path management, pedestrian visibility, and surrounding risk factors) were derived based on the surveyed data for the safety of the external environment of domestic and international school facilities. 179 school facilities nationwide (kindergartens, elementary schools, middle schools, high schools, and special schools) were analyzed for current cases of accidents that occurred mainly on school roads. Roughly 50% of the analyzed evaluation scores showed that it is necessary to improve the external environment of school facilities.

Glycemic Index Recognition and Practice of Low-Glycemic-Index Diet by Adults with Chronic Diseases in Some Rural Areas (일부 농촌 지역 당뇨병, 고혈압, 고지혈증을 가진 성인들의 당지수에 대한 인식도)

  • Shin, Sae-Ron;Han, A Lum
    • Journal of agricultural medicine and community health
    • /
    • v.39 no.2
    • /
    • pp.104-115
    • /
    • 2014
  • Background: The glycemic index (GI) indicates the rise in blood glucose caused by carbohydrate-containing foods. In Korea, there have been few studies on the understanding adults have of GI. Thus, this study investigated differences GI knowledge among the korean adults. Methods: A questionnaire on the perspective of GI and experience in GI education, participational intent to learn, general knowledge level, and dietary practice was conducted among those living in agricultural areas. Respondents were visitors to the health promotion center of a university hospital. Results: When asked about the GI familiarity, the standard of education, the relationships between diseases and GI, the diabetes group was better able to answer correctly than the other groups. However, the diabetes group showed either no difference or less correct responses for general knowledge of GI. With respect to their usual consideration and low GI dietary practice, the diabetes group provided higher responses than the other groups. On the whole, the diabetes group was better than the other groups for GI relative factor but none of the groups showed high levels for perspective, education, dietary practice of GI. Conclusions: The groups other than the diabetes group had a low perspective of GI, a lack of correct knowledge of GI, and did not follow a proper diet without considering GI. Even in the diabetes group the perspective, knowledge, and proper dietary practices were not adequate. Accordingly, further education of GI is necessary for diabetic patients, patients with chronic diseases and also people without diseases.