• Title/Summary/Keyword: High Rate Data Acquisition System

Search Result 52, Processing Time 0.032 seconds

Optimization of Data Acquisition System with Parallel Collection for PET

  • Yoshida, Eiji;Shimizu, Keiji;Murayama, Hideo
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.311-313
    • /
    • 2002
  • We are under development of a 3D PET scanner with depth of interaction (DOI) capable of high sensitivity and high resolution. In this scanner, a maximum data transfer rate of coincidence pair's event information is 10 Mcps and one event is a 64-bit data format. This maximum data transfer rate corresponds by 10 times a conventional PET scanner. A data acquisition system, which fulfills the specification of this scanner, is considered for parallel collection with banks including several coincidence units. Data transfer rate is improved by optimizing parameters of a message size, and so on.

  • PDF

Development of a distributed high-speed data acquisition and monitoring system based on a special data packet format for HUST RF negative ion source

  • Li, Dong;Yin, Ling;Wang, Sai;Zuo, Chen;Chen, Dezhi
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3587-3594
    • /
    • 2022
  • A distributed high-speed data acquisition and monitoring system for the RF negative ion source at Huazhong University of Science and Technology (HUST) is developed, which consists of data acquisition, data forwarding and data processing. Firstly, the data acquisition modules sample physical signals at high speed and upload the sampling data with corresponding absolute-time labels over UDP, which builds the time correlation among different signals. And a special data packet format is proposed for the data upload, which is convenient for packing or parsing a fixed-length packet, especially when the span of the time labels in a packet crosses an absolute second. The data forwarding modules then receive the UDP messages and distribute their data packets to the real-time display module and the data storage modules by PUB/SUB-pattern message queue of ZeroMQ. As for the data storage, a scheme combining the file server and MySQL database is adopted to increase the storage rate and facilitate the data query. The test results show that the loss rate of the data packets is within the range of 0-5% and the storage rate is higher than 20 Mbps, both acceptable for the HUST RF negative ion source.

Development of simultaneous multi-channel data acquisition system for large-area Compton camera (LACC)

  • Junyoung Lee;Youngmo Ku;Sehoon Choi;Goeun Lee ;Taehyeon Eom ;Hyun Su Lee ;Jae Hyeon Kim ;Chan Hyeong Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3822-3830
    • /
    • 2023
  • The large-area Compton camera (LACC), featuring significantly high detection sensitivity, was developed for high-speed localization of gamma-ray sources. Due to the high gamma-ray interaction event rate induced by the high sensitivity, however, the multiplexer-based data acquisition system (DAQ) rapidly saturated, leading to deteriorated energy and imaging resolution at event rates higher than 4.7 × 103 s-1. In the present study, a new simultaneous multi-channel DAQ was developed to improve the energy and imaging resolution of the LACC even under high event rate conditions (104-106 s-1). The performance of the DAQ was evaluated with several point sources under different event rate conditions. The results indicated that the new DAQ offers significantly better performance than the existing DAQ over the entire energy and event rate ranges. Especially, the new DAQ showed high energy resolution under very high event rate conditions, i.e., 6.9% and 8.6% (for 662 keV) at 1.3 × 105 and 1.2 × 106 s-1, respectively. Furthermore, the new DAQ successfully acquired Compton images under those event rates, i.e., imaging resolutions of 13.8° and 19.3° at 8.7 × 104 and 106 s-1, which correspond to 1.8 and 73 μSv/hr or about 18 and 730 times the background level, respectively.

Feed Rate Control for the Head-Feed Thresher (자동탈곡기(自動脱穀機)의 공급율(供給率) 제어(制御)(I) -공급율(供給率)에 따른 부하(負荷) 특성(特性)-)

  • Chung, C.J.;Ryu, K.H.;Choi, Y.S.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.3
    • /
    • pp.20-31
    • /
    • 1988
  • This study was undertaken to investigate the load characteristics of the head-feed thresher, which may be affected by various factors such as physical properties of grain, thresher design parameters and its operational condition. The study was conducted at an initial step toward developing an automatic feed-rate control system of the head-feed thresher. A microcomputer-based data acquisition system for the load-speed characteristic of the thresher-shaft and the rail-deflection of the feeding device in accordance with a varied feeding thickness was developed. The sensors being developed and used for sensing the torque and speed of the cylinder and the power-input-shaft and the feeding thickness showed a high accuracy. A microcomputer-based data acquisition system developed in this study was assessed as adequate for a rapid acquisition and analysis of data. The effect of the feed-rate on the torque and speed of the thresher shaft, when fed intermittently by bundles, affected not by the rice varieties but by the dryness of threshing material tested. When fed by the continuous constant thickness, the torque and speed of the cylinder due to the increase of the feed-rate or feeding thickness were given by the relation by the second order parabola.

  • PDF

Study on an On-line Measurement System of Corrosion Rate by Linear Polarization Resistance (분극저항에 의한 온라인 부식속도 측정 시스템에 관한 연구)

  • Moon, Jeon Soo;Lee, Jae Kun;Lee, Jae Bong;Park, Pyl Yang
    • Corrosion Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.135-140
    • /
    • 2012
  • The linear polarization resistance method is one of the widely used techniques for the corrosion rate monitoring in the water circulating systems of plants. The measurement is simple and rapid, so that a continuous on-line monitoring is possible without any shutdown of plants. A 2-electrode polarization corrosion rate measurement system was installed in a laboratory using a data acquisition board and PC. The signal processing parameters were optimized for the accurate corrosion rate measurement, and the polarization resistance was compensated with the solution resistance measured by the high frequency sine wave signal of an output channel. The precision of corrosion rate data was greatly improved by removing the initial noise signals on measuring the polarization resistance.

The Development of Rugged Embedded Measurement System by Using PXI Bus

  • Yu, Jae-Taeg;Kim, Dae-Won;Goo, Sang-Haw;Lee, Jang-Myung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.53.1-53
    • /
    • 2001
  • We have used many Instrumentations to acquire the performance data of vehicles for many years. but these could not satisfied with environment specifications (vibration, shock, temperature) and data processing speed to applicate the performance test for armored military vehicles because of having developed as a common vehicles/fixed installation equipments. So new rugged embedded measurement system required to do large data acquisition and high processing speed (Maximum sample rate : 1.25MHz/ch) with rugged environment specifications. We have developed embedded measurement system by using PXI(PCI eXtension for Instrumentation)bus interface which were composed of stand alone controller and versatile data acquisition boards(analog, digital, vision ...

  • PDF

Development of a Measurement System for High-Speed Spindle Displacement (고속 스핀들의 변위측정 시스템 개발)

  • Kim, H.G.;Chung, W.J.;Ju, J.H.;Cho, Y.D.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.6
    • /
    • pp.8-13
    • /
    • 2008
  • At present many research projects on high-speed spindles are being conducted. These projects require a measurement technique which includes heat expansion, vibration and displacement measurement according to angular velocity. This paper presents the development of a measurement system for high-speed spindle displacement. The measurement system is based on $LabView^{(R)}$ and features the following sensors: optical sensor which reacts to the position of a marker on the spindle and enables two Laser Displacement Sensors(LDS). These Laser Displacement Sensors send their data to a DAQ(Data Acquisition Device). It is important that the delay time caused by the response times of the sensors as well as the sampling rate of the DAQ is considered because the spindle revolves at very high speeds.

Microprocessor Based Laser Induced Fluorometry I. Development of System and Application to Liquid Chromatography

  • Kim, Ha-Suck;Park, Chan-Seung;Hwang, Eui-Jin;Chol, Q.-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.6
    • /
    • pp.253-259
    • /
    • 1984
  • An analytical applicability of the fluorescence detection with an optical multichannel analyzer to organic dyes was studied in this work. Continuous acquisition of spectra was possible with the use of a microcomputer. The maximum acquisition rate of a spetrum with 70-point average was about 3 seconds. Floppy discs were used to store data for later use in processing. Laser induced fluorescence detector in High Performance Liquid Chromatography was chosen for an application. Fluorescein below $10^{-15}g$ was detected satisfactorily using this system. With the help of microcomputer, three dimensional chromatograms of time-wavelength-intensity were obtained.

A characteristics on the generating Power of a 3-Phase Photovoltaic Power system for grid-connection (3상 계통연계형 태양광 발전시스템의 출력특성)

  • Ahn, Kyo-Sang;Lim, Hee-Chun;Hwang, In-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1171-1173
    • /
    • 2000
  • This paper was analyzed the high-frequency harmonics, power conversion rate, results of the system's monitor, and measuring data of the system power output of a 3-phase photovoltaic power system for grid-connection. The photovoltaic power system consists of a 3-phase inverter array, and data acquisition system. The result of an analyzing data of the 50 kW class grid-connected photovoltaic system showed the stable behavior in utility-interactive operation.

  • PDF